• Title/Summary/Keyword: buried continuous pipeline

Search Result 18, Processing Time 0.022 seconds

Fragility Curve of Continuous Buried Pipeline subjected to Transverse Permanent Ground Deformation due to Liquefaction (액상화.횡방향 영구지반변형을 받는 연속된 지중매설관로의 구조적 손상도곡선 도출)

  • Kim, Tae-Wook;Lim, Yun-Mook
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.358-365
    • /
    • 2006
  • In this study, fragility curves of continuous buried pipelines subjected to transverse PGD (permanent ground deformation) due to liquefaction are proposed. For the waterworks system, continuos buried pipelines made of ductile iron, poly ethylene, and poly vinyl chloride are analyzed and fragility curves are drawn. Fragility curves are based on the repetitive analyses results and formulated with the dominant factors of behaviour of buried pipeline. With the use of fragility curves, engineers can estimate the status of damage of buried pipeline without overall knowledge of relevant features. Especially, fragility curves proposed in this study will act as a major module of earthquake loss estimation method. Moreover, critical value of magnitude and width of transverse PGD (by which the full damage status of buried pipelines are induced) are estimated. With the use of regression curves of these values, pre evaluation of seismic safety of buried pipelines located within liquefaction hazardous region will be possible.

  • PDF

Numerical Analysis using Direct Shear Test Model for the Behavior of Buried Pipeline by the Fault Motion (단층활동시 매설 파이프라인의 거동에 대한 직접진단 시험모델 수치해석)

  • 장신남
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.6
    • /
    • pp.64-74
    • /
    • 1999
  • The frequency of earthquake occurrence tends to increase in Korea. Therefore, the stability of pipeline, such as watersupply pipe, gas pipe, and oil pipe etc. across fault zones in Gyoung-sang landmass is very important, expecially , in metropolitan area. There were some examples of the construction of buried pipeline across fault zones in Korea. the interactiion between the buried pipeline across fault zones and the ground is considered. As well, in the interfaces of them, the direct shear numerical analysis model including elasto-plastic joint element is assumed that the retained dilatancy theory in them, otherwise. Also, the other elements are modeled the ground is nonlinear elastic coutinuaus beam, respectively. In this study, the maximum shear force point exist inside retaine zone(anchored zone) during shwar (as fault sliding), and the distribution of pipeline's behavior is all alike them of pipeline buried in ladnsliding grounds. Since the pipeline is not continuous beam but jointed by steel-pipe segments , practically, on acting of a large bending moment or a shear force, then, those are may be unstable. The reaearch on this point may be new approach.

  • PDF

Beam models for continuous pipelines passing through liquefiable regions

  • Adil Yigit
    • Geomechanics and Engineering
    • /
    • v.37 no.2
    • /
    • pp.189-195
    • /
    • 2024
  • Buried pipelines can be classified as continuous and segmented pipelines. These infrastructures can be damaged either by ground movement or by seismic wave propagation during an earthquake. Permanent ground deformations (PGD) include surface faulting, liquefaction-induced lateral spreading and landslide. Liquefaction is a major problem for both superstructures and infrastructures. Buyukcekmece lake zone, which is the studied region in this paper, is a liquefaction prone area located near the North Anatolian Fault Line. It is an active fault line in Turkey and a major earthquake with a magnitude of around 7.5 is expected in this investigated region in Istanbul. It is planned to be constructed a new 12" steel natural gas pipeline from one side of the lake to the other side. In this study, this case has been examined in terms of two different support conditions. Firstly, it has been defined as a beam in liquefied soil and has built-in supports at both ends. In the other approach, this case has been modeled as a beam in liquefied soil and has vertical elastic pinned supports at both ends. These models have been examined and some solution proposals have been produced according to the obtained results. In this study, based on this sample, it is aimed to determine the behaviors of buried continuous pipelines subject to liquefaction effects in terms of buoyancy.

Response of steel pipeline crossing strike-slip fault in clayey soils by nonlinear analysis method

  • Hadi Khanbabazadeh;Ahmet Can Mert
    • Geomechanics and Engineering
    • /
    • v.34 no.4
    • /
    • pp.409-424
    • /
    • 2023
  • Response of the pipeline crossing fault is considered as the large strain problem. Proper estimation of the pipeline response plays important role in mitigation studies. In this study, an advanced continuum modeling including material non-linearity in large strain deformations, hardening/softening soil behavior and soil-pipeline interaction is applied. Through the application of a fully nonlinear analysis based on an explicit finite difference method, the mechanics of the pipeline behavior and its interaction with soil under large strains is presented in more detail. To make the results useful in oil and gas engineering works, a continuous pipeline of two steel grades buried in two clayey soil types with four different crossing angles of 30°, 45°, 70° and 90° with respect to the pipeline axis have been considered. The results are presented as the fault movement corresponding to different damage limit states. It was seen that the maximum affected pipeline length is about 20 meters for the studied conditions. Also, the affected length around the fault cutting plane is asymmetric with about 35% and 65% at the fault moving and stationary block, respectively. Local buckling is the dominant damage state for greater crossing angle of 90° with the fault displacement varying from 0.4 m to 0.55 m. While the tensile strain limit is the main damage state at the crossing angles of 70° and 45°, the cross-sectional flattening limit becomes the main damage state at the smaller 30° crossing angles. Compared to the stiff clayey soil, the fault movement resulting 3% tensile strain limit reach up to 40% in soft clayey soil. Also, it was seen that the effect of the pipeline internal pressure reaches up to about 40% compared to non-pressurized condition for some cases.

Analysis of the induced voltage on the GAS pipelines buried in parallel with 22.9kV distribution line (22.9kV 배전선로와 병행하는 가스배관의 유도성 유도전압 해석)

  • Lee, H.G.;Ha, T.H.;Bae, J.H.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.130-132
    • /
    • 2002
  • Because of the continuous growth of energy consumption and also the tendency to site power lines and pipelines along the same route, the close proximity of power lines and buried metallic pipelines has become more and more frequent. Therefore there has been and still is a slowing concern about possible hazards resulting from the influence of power lines on metallic pipelines. Underground pipelines that run parallel to or in close proximity to power lines are subjected to induced voltages caused by the time-varying magnetic fields produced by the power line currents. The induced electro- motive force cause currents circulation in the pipeline and voltages between the pipeline and surrounding earth. This paper analyzes the induced voltage on the gas pipelines buried in parallel with 22.9kV distribution lines. Their magnitude depends on the length of parallelism and on the distance between distribution lines and pipeline.

  • PDF

Response Analysis of Buried Pipeline Subjected to Longitudinal Permanent Ground Deformation (종방향 영구지반변형에 대한 지중 매설관로의 거동특성 해석)

  • 김문겸;임윤묵;김태욱;박종헌
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.2
    • /
    • pp.51-61
    • /
    • 2002
  • In this research, a numerical algorithm is developed for the response analysis of burined pipelines considering longitudinal permanent ground deformation(PGD) due to liquefaction induced lateral spreading. Buried pipelines and surrounding soil are modeled as continuous pipelines using the beam elements and a series of elasto-plastic springs represented for equivalent soil stiffness, respectively. Idealized various PGD patterns based on the observation of PGD are used as a loading configuration and the length of the lateral spread zone is considered as loading parameter. Numerical results are verified with other research results and efficient applicability of developed procedure is shown. Analyses are performed by varying different parameters such as PGD pattern, pipe diameter and pipe thickness. Through these procedures, relative influences of various parameters on the response of buried pipeline subject to longitudinal PGD are investigated.

A Fault Effect to Induced Voltage of Gas Pipeline in Transmission Systems (송전계통에서 고장에 따른 Gas Pipeline 유도전압 분석)

  • Kim, Hyun-Soo;Rhee, Sang-Bong;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1720-1725
    • /
    • 2008
  • Because of the continuous increasing of energy consumption, metallic pipelines are widely used to supply services to customers such as gas, oil, water, etc. Most common metallic pipelines are underground and are now frequently being installed in nearby electric power lines. In recent years, buried gas pipeline close to power lines can be subjected to hazardous induction effects, especially during single line to ground faults. because it can cause corrosion and it poses a threat to the safety of workers responsible for maintenance. Accordingly, it is necessary to take into consideration for analysis of induced voltage on gas pipelines in transmission lines. This paper analyzed the induced voltage on the gas pipelines due to the 154kV transmission lines in normal case and in different faulty case conditions using EMTP (Electro-Magnetic Transients Program).

The Study on the AC Interference of High Power Cable on Underground Gas Pipeline (전력케이블과 가스배관의 병행구간에 대한 교류부식 영향 검토 연구)

  • Bae, J.H.;Kim, D.K.;Ha, T.H.;Lee, H.G.;Kwak, B.M.;Lim, C.J.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.470-473
    • /
    • 2000
  • Because of the continuous growth of energy consumption, and also the tendency to site power lines and pipelines along the same routes, the close proximity of high voltage structures and metallic pipelines has become more and more frequent. Moreover, normal steady state and fault currents become higher as electric networks increase in size and power. Therefore, there has been and still is a growing concern (safety of people marking contact with pipeline, risk of damage to the pipeline coating, the metal and equipment connected to pipeline. especially cathodic protection system) about possible hazards resulting from the influence of high voltage power system on metallic structures(gas pipeline, oil pipeline and water pipeline etc.). Therefore, we analyze the interference problems when the gas pipeline is buried with power cable in the same submarine tunnel. This paper present the results of the study about interference mechanism, AC corrosion, limitation of safety voltage and analysis of indiction voltage.

  • PDF

A Study on the Safety Improvement of Buried Pipeline Using Scoring Model (Scoring Model을 이용한 매설배관 안전성 개선에 관한 연구)

  • Son, Myoung-Duck;Kim, Sung-Keun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.175-185
    • /
    • 2017
  • As the gas is manufactured, handled and used more often due to the continuous increase of gas, the related facility gets expanded and more complex causing small and big accident which causes economic loss including damage for humans and materials. The gas pipeline, the most common gas facility, has the biggest risk of accidents. Especially in the urban area and densely populated areas, the accident due to the high pressure pipeline may cause even more serious damages. To prevent the accident caused by the buried pipeline, it is required for the relevant authorities to evaluate the damage and risk of the whole pipeline system effectively. A risk is usually defined as a possibility or probability of an undesired event happening, and there is always a risk even when the probability of failure is set low once the pipeline is installed or under operation. It is reported that the accident caused by the failure of the pipeline rarely happens, however, it is important to minimize the rate of accidents by analyzing the reason of failure as it could cause a huge damage of humans and property. Therefore, the paper rated the risk of pipelines with quantitative numbers using the qualitative risk analysis method of the Scoring Model. It is assumed that the result could be effectively used for practical maintenance and management of pipelines securing the safety of the pipes.

Simplified modelling of continous buried pipelines subject to earthquake fault rupture

  • Paolucci, Roberto;Griffini, Stefano;Mariani, Stefano
    • Earthquakes and Structures
    • /
    • v.1 no.3
    • /
    • pp.253-267
    • /
    • 2010
  • A novel simple approach is presented for the seismic analysis of continuous buried pipelines subject to fault ruptures. The method is based on the minimization of the total dissipated energy during faulting, taking into account the basic factors that affect the problem, namely: a) the pipe yielding under axial and bending load, through the formation of plastic hinges and axial slip; b) the longitudinal friction across the pipe-soil interface; c) the lateral resistance of soil. The advantages and drawbacks of the proposed method are highlighted through a comparison with previous approaches, as well as with finite element calculations accounting for the 3D kinematics of the pipe-soil-fault systems under large deformations. Parametric analyses are also provided to assess the relative influence of the various parameters affecting the problem.