• 제목/요약/키워드: built-up compression member

검색결과 8건 처리시간 0.025초

Experimental testing of cold-formed built-up members in pure compression

  • Biggs, Kenneth A.;Ramseyer, Chris;Ree, Suhyun;Kang, Thomas H.-K.
    • Steel and Composite Structures
    • /
    • 제18권6호
    • /
    • pp.1331-1351
    • /
    • 2015
  • Cold-formed built-up members are compression members that are common in multiple areas of steel construction, which include cold-formed steel joints and stud walls. These members are vulnerable to unique buckling behaviors; however, limited experimental research has been done in this area. Give this gap, experimental testing of 71 built-up members was conducted in this study. The variations of the test specimens include multiple lengths, intermediate welds, orientations, and thicknesses. The experimental testing was devised to observe the different buckling modes of the built-up C-channels and the effects of the geometrical properties; to check for applicability of multiple intermediate welding patterns; and to evaluate both the 2001 and 2007 editions of the American Iron and Steel Institute (AISI) Specification for built-up members in pure compression. The AISI-2001 and AISI-2007 were found to give inconsistent results that at times were un-conservative or overly conservative in terms of axial strength. It was also found that orientation of the member has an important impact on the maximum failure load on the member.

비대칭 연결재를 갖는 조립식 압축부재의 좌굴 거동에 관한 실험 연구 II - 연결재 종류의 영향 - (An Experimental Study of Buckling Behavior in Built-up Compression Member with Unsymmetric Connectors II - Effect of Type of Connection Members -)

  • 강상훈;한만엽;조병두
    • 대한토목학회논문집
    • /
    • 제32권4A호
    • /
    • pp.217-225
    • /
    • 2012
  • 본 연구에서는 비대칭 연결재를 갖는 조립식 압축부재의 연결재 종류에 따른 좌굴 거동을 알아보기 위한 실 대형 실험을 실시하였다. 압축부재인 H-300 형강 10 m 부재 3개를 볼트 연결하여 총 길이 30 m가 되도록 2 m 간격으로 2열 배치한 후 연결재 종류가 띠판, ㄷ형강, 복 ㄷ형강인 경우에 대하여 압축 실험을 실시하였다. 본 논문에서는 연결재 종류에 따른 실험 좌굴 하중을 평가하고 이를 유한요소해석 결과인 좌굴하중과 Timoshenko 식에 의한 좌굴하중과 비교 분석 하였으며, 연결재 종류에 따른 조립식 압축부재의 좌굴 거동으로 인한 종방향 변위, 횡방향 변위, 변형률 등을 분석하였다. 실험 결과 비대칭 연결재를 갖는 조립식 압축부재의 연결재가 띠판일 때 보다 복 ㄷ형강일 때의 좌굴 하중은 4.2%, ㄷ형강일 때는 36.6% 감소하는 것으로 나타났다.

비대칭 연결재를 갖는 조립식 압축부재의 좌굴 거동에 관한 실험 연구 I - 연결재 간격의 영향 - (An Experimental study of Buckling Behavior in Built-up Compression Member with Unsymmetric Connectors I - Effect of Distance of Connecting Members -)

  • 강상훈;한만엽;조병두
    • 대한토목학회논문집
    • /
    • 제32권4A호
    • /
    • pp.207-215
    • /
    • 2012
  • 본 연구에서는 비대칭 연결재를 갖는 조립식 압축부재의 연결재 간격에 따른 좌굴 거동을 알아보기 위한 실 대형 실험을 실시하였다. 압축부재인 H-300 형강 10 m 부재 3개를 볼트 연결하여 총 길이 30 m가 되도록 2 m 간격으로 2열 배치한 후 연결재 간격이 4 m, 5 m, 6 m인 경우에 대하여 압축 실험을 실시하였다. 본 논문에서는 연결재 간격에 따른 실험 좌굴하중을 평가하고 이를 유한요소해석 좌굴하중 및 Timoshenko 식에 의한 좌굴하중과 비교 분석 하였으며, 연결재 간격의 증가에 따른 조립식 압축부재의 좌굴 거동으로 인한 종방향 변위, 횡방향 변위, 변형률 등을 분석하였다. 실험 결과 연결재 간격이 증가함에 따라 조립식 압축부재의 좌굴 하중은 비선형적으로 급격히 감소함을 알 수 있었다. 그리고 연결재 간격이 증가함에 따라 실험 좌굴 하중과 이론 좌굴 하중의 차이 및 실험 좌굴 하중과 유한요소해석 결과의 차이도 증가되는 것으로 나타났다.

Out-of-plane buckling and bracing requirement in double-angle trusses

  • Chen, Shaofan;Su, Mingzhou
    • Steel and Composite Structures
    • /
    • 제3권4호
    • /
    • pp.261-275
    • /
    • 2003
  • Truss members built-up with double angles back-to-back have monosymmetric cross-section and twisting always accompanies flexion upon the onset of buckling about the axis of symmetry. Approximate formulae for calculating the buckling capacity are presented in this paper for routine design purpose. For a member susceptible only to flexural buckling, its optimal cross-section should consist of slender plate elements so as to get larger radius of gyration. But, occurrence of twisting changes the situation owing to the weakness of thin plates in resisting torsion. Criteria for limiting the leg slenderness are discussed herein. Truss web members in compression are usually considered as hinged at both ends for out-of-plane buckling. In case one (or both) end of member is not supported laterally by bracing member, its adjoining members have to provide an elastic support of adequate stiffness in order not to underdesign the member. The stiffness provided by either compression or tension chords in different cases is analyzed, and the effect of initial crookedness of compression chord is taken into account. Formulae are presented to compute the required stiffness of chord member and to determine the effective length factor for inadequately constrained compressive diagonals.

잔류응력의 영향을 고려한 조립 H-형강 부재의 좌굴하중 및 설계압축강도 평가 (Evaluation of Buckling Load and Specified Compression Strength of Welded Built-up H-section Compression Members with Residual Stresses)

  • 이수권;양재근;강지석
    • 한국강구조학회 논문집
    • /
    • 제29권1호
    • /
    • pp.81-88
    • /
    • 2017
  • 확장단부판 접합부는 강구조물의 보-기둥 접합부 혹은 변단면 부재로 구성된 PEB 구조시스템에 적용되는 접합부의 한 형태이다. 확장단부판 접합부는 접합부를 구성하는 단부판의 두께, 고장력볼트의 게이지 거리, 고장력볼트 축부의 직경, 고장력볼트의 개수 등의 영향으로 상이한 거동특성을 나타낸다. 확장단부판 접합부는 미국 및 유럽 등지에서는 다양한 형태로 강구조물의 기둥-보 접합부에 적용되고 있으나 우리나라에서는 널리 적용되고 있지 않다. 이러한 이유로는 확장단부판 접합부에 대한 설계강도식 제안, 접합부상세 제안, 내진성능 평가, 제작 및 시공지침서 개발 등이 적절히 이루어지지 못하고 있기 때문이다. 따라서 이 연구는 비보강 확장단부판 접합부의 국내 적용을 위한 기초자료를 제공하기 위하여 진행하였다. 이를 위하여 두께 12mm의 비보강 확장단부판에 대한 비선형 유한요소해석 및 실험을 수행하였다.

강재 조립 기둥의 좌굴 거동에 대한 매개변수 해석 (Parameter Study of Buckling Behavior of Steel Built-up Column)

  • 김진용;김성보
    • 대한토목학회논문집
    • /
    • 제31권2A호
    • /
    • pp.79-87
    • /
    • 2011
  • 이 연구에서는 압축력을 받는 강재 조립 기둥의 좌굴 거동에 대한 매개변수 해석을 수행하였다. 압축력을 받는 조립기둥에서 기둥 전체 길이에 설치되는 H-형강 단면의 주 부재와 H-형강의 상 하 플랜지를 연결하는 배튼의 휨 및 전단력에 의한 전단변형효과를 고려한 좌굴하중 식을 제시하였다. 조립기둥의 길이, H-형강 주부재의 간격, 배튼의 개수, 배튼 작용을 하는 상 하 덮개판의 설치 여부에 따른 좌굴하중의 변화를 분석하였다. 일반 볼트 및 고장력 볼트가 사용된 조립 기둥의 설계에 사용되는 AISC 설계식이 배튼 및 주 부재의 간격이 큰 조립 기둥에도 활용할 수 있는지에 대한 적용성을 검토하였다. 이 연구에서 제시한 엄밀해 그리고 보요소 및 판요소를 사용한 유한요소해석 그리고 AISC의 설계식에 의한 결과를 비교 분석하여 강재 조립기둥의 좌굴거동에 대한 매개변수 해석을 수행하였다.

조립형 프리캐스트 콘크리트 보강재를 가지는 비좌굴가새의 이력특성 (Hysteresis Characteristics of Buckling Restrained Brace with Precast RC Restraining Elements)

  • 신승훈;오상훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권1호
    • /
    • pp.72-84
    • /
    • 2016
  • 종래 브레이스시스템은 횡력저항 및 층변위제어에 효율적이며 골조물량 감소에 따른 경제성이 향상되어 일반적인 강구조 횡력저항시스템으로 적용되고 있다. 그러나 압축측에서 항복응력에 도달하기 전 가새의 좌굴이 발생하여 충분한 내력을 발휘하지 못하고, 내력열화형의 이력거동으로 불안정상태가 된다. 좌굴에 의한 내력저하 개선시스템으로 중심재를 구속하여 좌굴방지가 가능한 비좌굴가새는 심재의 항복 이후에도 안정적인 이력특성을 나타내어 종래 브레이스에 비하여 에너지흡수능력이 우수하다. 최근 10년간 미국, 일본 및 대만에서 매우 다양한 형상의 비좌굴가새가 제안되었으나, 기존의 실험연구에서는 그 형상이 매우 제한적인 경향을 보이고 있다. 본 연구에서는 조립형 Precast RC 보강재를 가지는 비좌굴가새를 제작하고 이력특성을 평가하기 위한 부재실험을 수행하였다. 또한 실험결과를 AISC(2005)의 요구조항과 비교하였다.

개량수평스티프너를 보강한 고강도강(HSA800) 접합부 내진성능평가 (Seismic Performance of High Strength Steel(HSA800) Beam-to-Column Connections with Improved Horizontal Stiffener)

  • 오상훈;박해용
    • 한국강구조학회 논문집
    • /
    • 제26권4호
    • /
    • pp.361-373
    • /
    • 2014
  • 건설시장이 보다 고층화 장스팬화되어감에 따라 건설재료 또한 고성능화되어가고 있다. 이러한 추세에 따라 국내에서도 건축용 인장강도 800MPa급 강이 개발되었다. 현재 고강도강을 대상으로 한 휨재, 압축재, 접합부의 적용실험이 지속적으로 이루어지고 있으나 아직까지 고강도강 적용에 대한 설계지침이 마련되어 있지 않은 실정이다. 이 중 고강도강 기둥-보 접합부의 경우 고강도강의 특성이라고 할 수 있는 높은 항복비에 의해 연성접합부 구현에 대한 평가가 비관적이며 연구자료 또한 미비하다. 따라서 본 연구에서는 고강도강 기둥-보 접합부의 변형능력 향상을 위하여 접합상세를 변수로 하고 연성접합부 구현을 위한 연구를 수행하였다. 접합상세로는 논스캘럽 공법과 개량 수평스티프너 공법을 적용하였다. 적용한 접합상세를 가지는 접합부 모델들을 대상으로 실물대 반복재하실험과 비선형 유한요소해석을 실시하였다. 연구결과, 제시한 접합상세를 가지는 고강도강 기둥-보 접합부의 구조성능은 KBC기준의 특수모멘트골조의 요구성능을 만족하는 것으로 나타났다.