• Title/Summary/Keyword: building structural systems

Search Result 671, Processing Time 0.03 seconds

Seismic performance of RC buildings subjected to past earthquakes in Turkey

  • Inel, Mehmet;Meral, Emrah
    • Earthquakes and Structures
    • /
    • v.11 no.3
    • /
    • pp.483-503
    • /
    • 2016
  • This study aims to evaluate seismic performance of existing low and mid-rise reinforced concrete buildings by comparing their displacement capacities and displacement demands under selected ground motions experienced in Turkey as well as demand spectrum provided in 2007 Turkish Earthquake Code for design earthquake with 10% probability of exceedance in 50 years for soil class Z3. It should be noted that typical residential buildings are designed according to demand spectrum of 10% probability of exceedance in 50 years. Three RC building sets as 2-, 4- and 7-story, are selected to represent reference low-and mid-rise buildings located in the high seismicity region of Turkey. The selected buildings are typical beam-column RC frame buildings with no shear walls. The outcomes of detailed field and archive investigation including approximately 500 real residential RC buildings established building models to reflect existing building stock. Total of 72 3-D building models are constructed from the reference buildings to include the effects of some properties such as structural irregularities, concrete strength, seismic codes, structural deficiencies, transverse reinforcement detailing, and number of story on seismic performance of low and mid-rise RC buildings. Capacity curves of building sets are obtained by nonlinear static analyses conducted in two principal directions, resulting in 144 models. The inelastic dynamic characteristics are represented by "equivalent" Single-Degree-of- Freedom (ESDOF) systems using obtained capacity curves of buildings. Nonlinear time history analysis is used to estimate displacement demands of representative building models idealized with (ESDOF) systems subjected to the selected ground motion records from past earthquakes in Turkey. The results show that the significant number of pre-modern code 4- and 7-story buildings exceeds LS performance level while the modern code 4- and 7-story buildings have better performances. The findings obviously indicate the existence of destructive earthquakes especially for 4- and 7-story buildings. Significant improvements in the performance of the buildings per modern code are also obvious in the study. Almost one third of pre-modern code buildings is exceeding LS level during records in the past earthquakes. This observation also supports the building damages experienced in the past earthquake events in Turkey.

Validation of the seismic response of an RC frame building with masonry infill walls - The case of the 2017 Mexico earthquake

  • Albornoz, Tania C.;Massone, Leonardo M.;Carrillo, Julian;Hernandez, Francisco;Alberto, Yolanda
    • Advances in Computational Design
    • /
    • v.7 no.3
    • /
    • pp.229-251
    • /
    • 2022
  • In 2017, an intraplate earthquake of Mw 7.1 occurred 120 km from Mexico City (CDMX). Most collapsed structural buildings stroked by the earthquake were flat slab systems joined to reinforced concrete (RC) columns, unreinforced masonry, confined masonry, and dual systems. This article presents the simulated response of an actual six-story RC frame building with masonry infill walls that did not collapse during the 2017 earthquake. It has a structural system similar to that of many of the collapsed buildings and is located in a high seismic amplification zone. Five 3D numerical models were used in the study to model the seismic response of the building. The building dynamic properties were identified using an ambient vibration test (AVT), enabling validation of the building's finite element models. Several assumptions were made to calibrate the numerical model to the properties identified from the AVT, such as the presence of adjacent buildings, variations in masonry properties, soil-foundation-structure interaction, and the contribution of non-structural elements. The results showed that the infill masonry wall would act as a compression strut and crack along the transverse direction because the shear stresses in the original model (0.85 MPa) exceeded the shear strength (0.38 MPa). In compression, the strut presents lower stresses (3.42 MPa) well below its capacity (6.8 MPa). Although the non-structural elements were not considered to be part of the lateral resistant system, the results showed that these elements could contribute by resisting part of the base shear force, reaching a force of 82 kN.

Design and implementation of a SHM system for a heritage timber building

  • Yang, Qingshan;Wang, Juan;Kim, Sunjoong;Chen, Huihui;Spencer, Billie F. Jr.
    • Smart Structures and Systems
    • /
    • v.29 no.4
    • /
    • pp.561-576
    • /
    • 2022
  • Heritage timber structures represent the history and culture of a nation. These structures have been inherited from previous generations; however, they inevitably exhibit deterioration over time, potentially leading to structural deficiencies. Structural Health Monitoring (SHM) offers the potential to assess operational anomalies, deterioration, and damage through processing and analysis of data collected from transducers and sensors mounted on the structure. This paper reports on the design and implementation of a long-term SHM system on the Feiyun Wooden Pavilion in China, a three-story timber building built more than 500 years ago. The principles and features of the design and implementation of SHM systems for heritage timber buildings are systematically discussed. In total, 104 sensors of 6 different types are deployed on the structure to monitor the environmental effects and structural responses, including air temperature and humidity, wind speed and direction, structural temperatures, strain, inclination, and acceleration. In addition, integrated data acquisition and transmission subsystem using a newly developed software platform are implemented. Selected preliminary statistical and correlation analysis using one year of monitoring data are presented to demonstrate the condition assessment capability of the system based on the monitoring data.

Design of a Linear Mass Excitation System for Simulating Wind-induced Responses of a Building Structure (풍하중 구현 및 내풍특성 평가를 위한 선형질량 가진시스템 설계)

  • Park, Eun-Churn;Lee, Sang-Hyun;Min, Kyung-Won;Kang, Kyung-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.661-668
    • /
    • 2007
  • In this paper, excitation systems using linear mass shaker (LMS) are presented in order to simulate the wind induced responses of a building structure. The actuator force for the excitation systems is calculated by using the inverse transfer function of a target structural response to the actuator. Filter and envelop function are used such that the error between the wind and actuator induced responses is minimized by preventing the actuator from exciting unexpected modal response and initial transient response. The analyses results from a 76-story benchmark building problem in which wind load obtained by wind tunnel test is given, indicate that the excitation system installed at a specific floor can approximately embody the structural responses induced by the wind load applied to each floor of the structure. The excitation system designed by the proposed method can be effectively used for evaluating the wind response characteristics of a practical building structure and for obtaining an accurate analytical model of the building under wind load.

  • PDF

Excitation System for Simulating Wind-induced Responses of a Building Structure using an Active Tuned Mass Damper (ATMD를 이용한 건축 구조물의 풍응답 구현을 위한 가진시스템)

  • Park, Eun-Churn;Lee, Sang-Hyun;Min, Kyung-Won;Kang, Kyung-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.210-215
    • /
    • 2007
  • In this paper, excitation systems using an active tuned mass damper (ATMD) are presented in order to simulate the wind induced responses of a building structure. The actuator force for the excitation systems is calculated by using the inverse transfer function of a target structural response to the actuator. The analyses results from a 76-story benchmark building problem in which wind load obtained by wind tunnel test is given, indicate that the excitation system installed at a specific floor can approximately embody the structural responses induced by the wind load applied to each floor of the structure. The excitation system designed by the proposed method can be effectively used for evaluating the wind response characteristics of a practical building structure and for obtaining an accurate analytical model of the building under wind load.

  • PDF

Diagrid Structural System for High-Rise Buildings: Applications of a Simple Stiffness-based Optimized Design

  • Gerasimidis, Simos;Pantidis, Panos;Knickle, Brendan;Moon, Kyoung Sun
    • International Journal of High-Rise Buildings
    • /
    • v.5 no.4
    • /
    • pp.319-326
    • /
    • 2016
  • The ingenuity of structural engineers in the field of tall and super-tall buildings has led to some of the most remarkable inventions. During this evolution of structural engineering concepts in the last 100 years, the technical challenges that engineers encountered were extraordinary and the advances were unprecedented. However, as the accomplishments of structural engineers are progressing, the desire for taller and safer structures is also increasing. The diagrid structural system is part of this evolving process as it develops a new paradigm for tall building design combining engineering efficiency and new architectural expression. The first appearances of this type of tall buildings have already been constructed and the interest of both engineering and architectural communities is growing mainly due to the many advantages compared to other structural systems. This paper presents a simple approach on optimizing member sizes for the diagonals of steel diagrid tall buildings. The optimizing method is based on minimizing the volume of the diagonal elements of a diagrid structure. The constraints are coming from the stiffness-based design, limiting the tip deflection of the building to widely accepted regulative limits. In addition, the current paper attempts to open the discussion on the important topic of optimization and robustness for tall buildings and also studies the future of the diagrid structural system.

A Study for Transfer Girder Details of the Upper-Wall and Lower-Frame Structures (주상복합구조의 전이보 상세설계기법 연구)

  • 이한선;김상연;고동우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.529-534
    • /
    • 2000
  • Hybrid building structure, which comprise both the residential and commercial spaces in a building, are composed of upper shear-walls and lower frames. In these hybrid structures, the structural analysis and design of transfer systems which link upper-wall and lower-frame are crucial. The available structural design methods for the transfer girder are performed by taking a prototype structure, and the details of transfer girder based on these design methods are presented and compared with regard to the dimensions and amount of reinforcements.

  • PDF

Conceptual design of buildings subjected to wind load by using topology optimization

  • Tang, Jiwu;Xie, Yi Min;Felicetti, Peter
    • Wind and Structures
    • /
    • v.18 no.1
    • /
    • pp.21-35
    • /
    • 2014
  • The latest developments in topology optimization are integrated with Computational Fluid Dynamics (CFD) for the conceptual design of building structures. The wind load on a building is simulated using CFD, and the structural response of the building is obtained from finite element analysis under the wind load obtained. Multiple wind directions are simulated within a single fluid domain by simply expanding the simulation domain. The bi-directional evolutionary structural optimization (BESO) algorithm with a scheme of material interpolation is extended for an automatic building topology optimization considering multiple wind loading cases. The proposed approach is demonstrated by a series of examples of optimum topology design of perimeter bracing systems of high-rise building structures.

Seismic Performance Evaluation of Complex-Shaped Tall Buildings by Lateral Resisting Systems (횡력저항시스템에 따른 비정형 초고층건물 내진성능평가)

  • Youn, Wu-Seok;Lee, Dong-Hun;Cho, Chang-Hee;Kim, Eun-Seong;Lee, Dong-Chul;Kim, Jong-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.6
    • /
    • pp.513-523
    • /
    • 2012
  • The objective of this research is to examine how the lateral resisting system of selected prototypes are affected by seismic zone effect and shape irregularity on its seismic performance. The lateral resisting systems are divided into the three types, diagrid, braced tube, and outrigger system. The prototype models were assumed to be located in LA, a high-seismicity region, and in Boston, a low-seismicity region. The shape irregularity was classified with rotated angle of plane, $0^{\circ}$, $1^{\circ}$, $2^{\circ}$. This study performed two parts of analyses, Linear Response and Non-Linear Response History(NLRH) analysis. The Linear Response analysis was used to check the displacement at the top and natural period of models. NLRH analysis was conducted to invest base shear and story drift ratio of buildings. As results, the displacement of roof and natural period of three structural systems increase as the building stiffness reduces due to the changes in rotation angle of the plane. Also, the base shear is diminished by the same reason. The result of NLRH, the story drift ratio, that was subject to Maximum Considered Earthquake(MCE) satisfied 0.045, a recommended limit according to Tall Building Initiative(TBI).

Reliability-Based Performance Assessment and Prediction of Tendon Corrosion in K-UHPC Bridges (K-UHPC 교량의 긴장재 부식에 관한 신뢰성 기반 성능 평가 및 예측)

  • Kwon, Kihyon;Park, Sung Yong;Cho, Keunhee;Kim, Sung Tae;Park, Jong Beom;Kim, Byung Suk
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.3
    • /
    • pp.75-81
    • /
    • 2016
  • Tendon corrosion reliability in KICT-ultra high performance concrete (K-UHPC) bridges is assessed and predicted considering uncertainties in flexural bending capacity and corrosion occurrence. In post-tensioning bridge systems, corrosion is a one of most critical failure mechanisms due to strength reduction by it. During the entire service life, those bridges may experience lifetime corrosion deterioration initiated and propagated in tendons which are embedded not only in normal concrete but also in K-UHPC. For this reason, the time-variant corrosion performance has to be assessed. In the absence of in-depth researches associated with K-UHPC tendon corrosion, a reliability-based prediction model is developed to evaluate lifetime corrosion performance of tendon in K-UHPC bridges. In 2015, KICT built a K-UHPC pilot bridge at 168/5~168/6 milestone on Yangon-Mandalay Expressway in Myanmar, by using locally produced tendons which post-tensioned in longitudinal and lateral ways of K-UHPC girders. For an illustrative purpose, this K-UHPC bridge is used to identify the time-variant corrosion performance.