A Review on Changes in Spatial Formation of the Sangrojun Area in Tongdo Temple (통도사 상로전 영역의 공간구성 변화 고찰)

  • Hong, Jae-Dong
    • Journal of architectural history
    • /
    • v.10 no.3 s.27
    • /
    • pp.45-60
    • /
    • 2001
  • The Tongdo temple have been transformed continuously since its first establishment about 1300 years ago. Nevertheless three critical elements specified by 'Jajangyulsa', founder of the temple have not varied over the times but rather strengthened and strongly combined. All elements and doctrines of the religion coexist and form a harmony within the whole of the temple. This researcher examined what changes, or combinations, in spatial formation were sought for such unique structures of the Tongue temple by focusing mainly on the Sangrojun area of the temple to obtain the following findings. First. unlike a work by a Japanese researcher 'Sekino Tadashi', the east yard of the main building was found located on the section line which corresponded to the separation line of Yungkuncheokdo(營建尺度=measure running) from the edge of the Keumkangkyedan(金剛戒壇 =Buddhist platform) embankment to the corner column of the Kamrodang. This was confirmed as a result of the review of photos shown in [Chosun Kojukdobo]. Second, the number of stairs used for the Keumkangkyedan was thought to become three when the temple was firstly restored in 1379 as a result that this researcher reviewed Chinese literature 'DoSun' and [Kyedandokyung(戒壇圖經)], records by 'Lee saek' and 'Jung Shihan', studies of Yungkun measure and actual changes in the temple. Then the temple was forth restored in 1705 when the second of the stairs was changed in area and height and at the same time grounded hard for a space for a Buddhist service. Third, the roof of the main building was probably changed in shape during the Koryo period when the plane structure, furnish arrangement, emphasized front, stone lanterns of the building and political factors of that time were all considered. Fourth, the main building was Initially designed to provide a Buddhist sermon service which was assumedly followed by a similar service at a Keumkangkyedan. Thus the main building had a small window on the northern side which might be opened up to look out or otherwise go outside like a door. However, the window was probably locked up like a surrounding wall since the main building was entirely repaired after the end of Japanese invasion of Korea in 1592.

  • PDF

An Analysis of the Appropriate Number of People Per Apartment Household According to NFPA 101 (NFPA 101에 의한 아파트 한 세대당 적정 수용인원 분석)

  • Cho, Ji-Eun;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.331-337
    • /
    • 2020
  • The study analyzes the appropriate number of people per a household by applying an evacuation simulation to a 27-floor apartment in accordance with the NFPA 101 standard. The results of the analysis are as follows. First, if there are three people residing in each household, there would be 156 households in total, of which 85.25% were evacuated within 5 minutes. Second, 208 households with 4 residents were evacuated within 5 minutes. Third, if there are five people residing in each household, there would be a total of 260 households and 71.92% of residents were evacuated within 5 minutes. Lastly, 62.82% of the 312 households, each consisting of 6 people, were evacuated within 5 minutes. Measures to reduce evacuation time include determining the width of the stairs according to the number of people indoors, the number of floors in the building, the slope of stairs, and the users' characteristics, the design reflecting the ventilation conditions of the stairs, the installment of outdoor evacuation stairs, two-way stairs, evacuation lift, and the installation of an evacuation safety zone for people to evacuate outside of the building in the middle floors. In addition, measures, such as the mandatory installation of automatic emergency door open-close device to the rooftop, are required to facilitate rooftop evacuation.

Vibration Isolation Method of Walking Space in the Multiplex Cinema (Multiplex 영화관의 보행면 진동방지 대책)

  • Lee, Sung-Ho;Jung, Gab-Cheol
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.913-920
    • /
    • 2000
  • The hall and the projection room of the multiplex cinema being constructed on the sixth and seventh floors at Jeonpo-dong market, Pusan, is composed of structural beams and decks considering the structures self weight problem, and the following problems are expected: - Vibration and noise generated on the floors by moving audiences may annoy the audiences in the other hall - Vibration and noise generate on the floor of the nearby hall as the audiences walk through the alley near the projection room - Vibration and noise generate on the floor of the hall nearby the projection room as the film drops This study measured and reviewed the vibration amount of the seven representative transferring routes that were selected for the halls and the alley near the projection room. Based on the analysis, the model hall was constructed and the vibration in the hall was estimated after cutting the deck. Also, this study constructed the steel stairs and investigated the vibration transferring characteristics to decide whether to construct the steel stairs in the building. Finally, the results were evaluated by actually using the stairs and reviewed the appropriateness of the measurement.

  • PDF

The Gender Difference in the Occupational Hazards and Injuries of Cleaning Workers and Janitors

  • Choi, Chang Lyul
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.5
    • /
    • pp.411-420
    • /
    • 2017
  • Objective: The purpose of this study is to analyze the accident characteristics according to the gender of the injured workers in building cleaning and to reflect them in the Industrial Accident Prevention Policy. Background: An analysis of industrial accidents is an essential process for establishing systematic industrial accident prevention measures. In order to establish industrial accident prevention measures for workers effectively, it is necessary to analyze accident characteristics by job type for workers who do the same work. Method: In this study, we analyzed the accident characteristics of 1,645 janitors who were approved of work-related injuries in 2015. We also analyzed the characteristics according to gender by dividing them into worker-related factors and accident-related factors. Results: The accidents caused to the janitors showed different characteristics according to gender, age, work experience, agency of accident, and distribution of original cause materials. In other words, 70.2% occurred to workers over 60 years old and 56.2% occurred to unskilled workers with less than a year of work experience. In the case of accident pattern, 79.1% occurred in tripping (slip) hazards, and 68.2% of accidents occurred on the floor (including the ground) and the stairs, indicating that the accident occurred most frequently during cleaning work on the floor or stairs. Conclusion and Application: The results of the study on the accident characteristics of the janitors can be used as basic data for systematic preventive measures against accidents occurring to the elderly female workers in the service industry.

Risk Analysis According to the Installation of Fire Doors on Direct Stairs in the Event of a Fire in an Old Apartment (노후 아파트 화재 시 직통계단의 방화문 설치 여부에 따른 위험성 분석)

  • Lee, Sang Im;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.869-878
    • /
    • 2021
  • This study is a study on 11-story apartments that increase the event of fires in old apartments where building-related laws and regulations are not retroactively applied. As a result of analyzing the risk of installing fire doors in Improvement Scenario 2-4, assuming that fire doors are installed as basic scenario 1 in the existing situation where fire doors are not installed at the entrance of direct stairs. In basic scenario 1, the visible distance to the entrance of the direct staircase due to the spread of smoke was 260 seconds. Improvement scenarios 3 to 4 with fire doors installed open 300 seconds after the fire was recognized, and when the fire doors were installed at the entrance of the direct stairs, the visibility to the entrance of the statistics team was less than 600 seconds. In this case, the visibility was 600 seconds at the time of installation of the fire door, and scenarios 3 to 4 increased 56.6% compared to scenario 1, lowering the risk of evacuation by more than 50%. In order to eliminate the risk of non-installation of direct statistical groups that increase the risk of smoke spread, building-related laws such as the Fire Fighting Act shall be retroactively applied when installing a direct stairway entrance or balcony folding evacuation system. The improvement caused by the installation of fire doors has numerically proven the necessity of fire doors during evacuation, and the importance of maintaining fire doors can be grasped.

A Study on the Design Criteria of Pedestrian Facility (Stairs) by Motion Analysis of Walking Parameters in the Elderly (고령자 보행변수 실측을 통한 보행시설물 설계기준 정립 1: 고령자 보행특성을 고려한 계단 챌면 높이 연구)

  • ROH, Chang-Gyun;PARK, Bum Jin
    • Journal of Korean Society of Transportation
    • /
    • v.35 no.5
    • /
    • pp.396-408
    • /
    • 2017
  • In Korea, the number of elderly has been increasing rapidly. So it is also expected that the economic activity and the trip frequency of the elderly will increase. On the other hand, elderly related accidents such as falls during walking are steadily increasing and the satisfaction about pedestrian environment of elderly is very low. In this paper, we found one of the reasons for these dissatisfaction in pedestrian facility, which is not considering the walking ability (about 75% of non-elderly person) of the elderly. So, we analyze the kinematic walking characteristics of the elderly with the motion analysis system, when the elderly use stairs. As a result of analysis of various walking variables, the current standard for stairway height in Korean law (18cm) requires excessive force to elderly so it was difficult for elderly to keep the balance of the body in ascending and descending walk of stairs. In this paper, we propose the stair design criteria through the cluster analysis of walking parameters reflecting the gait characteristics of the elderly. This change is not a big for non-elderly person, but it can promote more socioeconomic activities for the elderly.

A study on measures for the mitigation of fire damage in Korea super high-rise building through the improvement of domestic·foreign standards (국·내외 기준개선을 통한 국내 초고층 건축물의 화재피해경감 대책에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.2
    • /
    • pp.233-248
    • /
    • 2017
  • Uniform laws and regulations and reasonable design is necessary for the prevention of possible fire in super high-rise building. To this end, this study focused on super high-rise and massive building-related architectural review performance-based design (PBD) evaluation disaster impact assessment (DIA), and provided fire engineering measures for improving fire prevention on the basis of performance-based design by analyzing the buildings subject to these systems and problems in terms of contents. Above all, in the aspect of law and standard improvement, first, with regard to dual parts of two statutes though significant portion of them has the same contents in performance-based design (PBD) evaluation and disaster impact assessment (DIA), it is necessary to operate the systems after making them conform with each other and consolidating or abolishing them. Second, if it is impossible to consolidate or abolish performance-based design (PBD) evaluation and disaster impact assessment (DIA), the areas of contents of performance-based design (PBD) evaluation and disaster impact assessment (DIA) should be precisely classified and established. Next, engineering improvement measures against fire hazard in super high-rise building are as follows. First, it is necessary to revise the provisions of straight-run stairs in special escape stairs. And in case of installing a mechanical smoke exhaust system instead of smoke vent, sandwich pressurization used in the United Stated should be permitted. Second, with regard to smoke control system for special escape stairs, it was shown that there was necessity for revising the standards in order to enable air to be supplied according to section in case of fire, carrying out performance-based design, and the like from the early design stages to the completion stages. In the future, it is expected that an epoch-making contribution will be made to a decrease in casualties and property damage due to fire in case of super high-rise building where the results can be reflected after carrying out a study on maintenance and carrying out an additional study on other considerations of super high-rise building together with reflecting the improvement measures provided in the above-mentioned study.

Analysis of Evacuation Time According to Variation of Evacuation Stairs' Width in Large-Scale Goshiwons (대규모 고시원의 피난계단 폭의 변화에 따른 피난소요시간 분석)

  • Oh, Su-cheol;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.5
    • /
    • pp.641-651
    • /
    • 2022
  • This research compares and analyzes evacuation time depending on the change in stair width in case of fire at Goshiwons. For this, a simulation has been conducted based on possible evacuation time according to the calculation method for the number of people admittable to a specific target for fire fighting equipped with accommodation. Currently, Gosiwon, which is classified as an accommodation facility (a total floor area of 500 m2 or more), uses blind spots prescribed by the Fire Services Act, Building Act, and Parking Act to build a high-rise building on a small area of land, and most Gosiwon is transformed into a modified accommodation. This is in line with the owner's operating profit, so it is expected to show a continuous increase. Securing the golden time of Gosiwon evacuation time is the last bastion of Gosiwon residents who belong to the economically disadvantaged in our society, and we hope this study will serve as a starting point for discussions on revising related laws and regulations to establish a social safety net As a result of the evacuation simulation analysis, the evacuation time was the least when the width of the group and the evacuation stairs were expanded to 200cm, and the evacuation time of the existing building was reduced by up to 166.3 seconds by comparing 648.4 seconds and scenario 6. This analysis can be meaningful, in that the width of the evacuation stairs revision of related laws and regulations for the safety of multiplex available premises.

The Analysis on the Present Condition of Noise of the Residents Subjective Responses in One-Room Type Multi-Family Housing around Campus (대학주변 원룸형 다가구주택에 있어서 거주자 평가에 의한 소음실태분석)

  • Choi Yoon-Jung
    • Journal of the Korean Home Economics Association
    • /
    • v.41 no.10 s.188
    • /
    • pp.1-13
    • /
    • 2003
  • The purpose of this study is to make clear the present condition and the reason of noise in one-room ape multi-family housing around the campus by residents' subjective responses. The respondents are 104 residents living in one-room ape multi-family housing around the campus. The results are as follows. 1) The residents show relatively non-positive responses at evening and night on the present condition of noise in outdoor and indoor of building or indoor of house unit. 2) The types of outdoor noise of building are checked frequently are 'talking loudness' and 'traffic noise'. 'Walking and talking sounds in stairs and corridors' among the types of indoor noise of building shows highest percentage. They answer 'living equipment noise' and 'water hammer' as major types of indoor noise of house unit.

An Evaluation of Stairs and Handrails on Building

  • Dae-Sig Kim;Tae-Woo Lee
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.19 no.39
    • /
    • pp.171-175
    • /
    • 1996
  • 본 연구는 건축에서 발생할 수 있는 미끄럼 사고와 추락 사고에 대한 예방과 계단 및 계단의 손잡이의 설계를 평가하고자 한다. 본 연구를 위하여 두 개의 추수가 다른 계단과 계단의 손잡이를 선택하였고, 계단과 계단 손잡이의 설계에 있어서 인체 측정치를 변수로 선정하였다. 실증을 위하여 설문을 분석, 결론을 도출하였다.

  • PDF