• 제목/요약/키워드: building modelling

검색결과 288건 처리시간 0.026초

Micro modelling of masonry walls by plane bar elements for detecting elastic behavior

  • Doven, Mahmud Sami;Kafkas, Ugur
    • Structural Engineering and Mechanics
    • /
    • 제62권5호
    • /
    • pp.643-649
    • /
    • 2017
  • Masonry walls are amongst the oldest building systems. A large portion of the research on these structures focuses on the load-bearing walls. Numerical methods have been generally used in modelling load-bearing walls during recent years. In this context, macro and micro modelling techniques emerge as widely accepted techniques. Micro modelling is used to investigate the local behaviour of load-bearing walls in detail whereas macro modelling is used to investigate the general behaviour of masonry buildings. The main objective of this study is to investigate the elastic behaviour of the load- bearing walls in masonry buildings by using micro modelling technique. In order to do this the brick and mortar units of the masonry walls are modelled by the combination of plane truss elements and plane frame elements with no shear deformations. The model used in this study has fewer unknowns then the models encountered in the references. In this study the vertical frame elements have equivalent elasticity modulus and moment of inertia which are calculated by the developed software. Under in-plane static loads the elastic displacements of the masonry walls, which are encountered in literature, are calculated by the developed software, where brick units are modelled by plane frame elements, horizontal joints are modelled by vertical frame elements and vertical joints are modelled by horizontal plane truss elements. The calculated results are compatible with those given in the references.

Investigation of effects of twin excavations effects on stability of a 20-storey building in sand: 3D finite element approach

  • Hemu Karira;Dildar Ali Mangnejo;Aneel Kumar;Tauha Hussain Ali;Syed Naveed Raza Shah
    • Geomechanics and Engineering
    • /
    • 제32권4호
    • /
    • pp.427-443
    • /
    • 2023
  • Across the globe, rapid urbanization demands the construction of basements for car parking and sub way station within the vicinity of high-rise buildings supported on piled raft foundations. As a consequence, ground movements caused by such excavations could interfere with the serviceability of the building and the piled raft as well. Hence, the prediction of the building responses to the adjacent excavations is of utmost importance. This study used three-dimensional numerical modelling to capture the effects of twin excavations (final depth of each excavation, He=24 m) on a 20-storey building resting on (4×4) piled raft. Because the considered structure, pile foundation, and soil deposit are three-dimensional in nature, the adopted three-dimensional numerical modelling can provide a more realistic simulation to capture responses of the system. The hypoplastic constitutive model was used to capture soil behaviour. The concrete damaged plasticity (CDP) model was used to capture the cracking behaviour in the concrete beams, columns and piles. The computed results revealed that the first excavation- induced substantial differential settlement (i.e., tilting) in the adjacent high-rise building while second excavation caused the building tilt back with smaller rate. As a result, the building remains tilted towards the first excavation with final value of tilting of 0.28%. Consequently, the most severe tensile cracking damage at the bottom of two middle columns. At the end of twin excavations, the building load resisted by the raft reduced to half of that the load before the excavations. The reduced load transferred to the piles resulting in increment of the axial load along the entire length of piles.

GIS와 실영상을 이용한 지리 모델링 시스템 (A Geographic Modeling System Using GIS and Real Images)

  • 안현식
    • Spatial Information Research
    • /
    • 제12권2호
    • /
    • pp.137-149
    • /
    • 2004
  • 지금까지 3차원 지리 공간 구성을 위해서는 2D 지리 데이터로부터 수작업으로 건물의 프레임을 만들고 단면 영상을 붙여서 건물을 모델링하였다. 본 논문에서는 지도 데이터의 표준으로 사용되고 있는 수치지도와 임의의 위치에서 입력된 건물의 영상을 이용하여 3D 지리공간을 자동으로 구성하는 지리 모델링 시스템을 제안한다. 먼저 OpenGL을 이용하여 가상공간에 지형을 TIN과 DEM 방법으로 형상화한다. 건물을 모델링하기 위해 임의의 위치에서 카메라로 입력한 건물 영상으로부터 건물의 단면 영상을 추출하고, 검출된 수직선으로부터 카메라의 위치를 자동으로 추정하고, 건물의 높이를 계산하고, 얻어진 단면영상과 texture 맵핑을 하여 실제 공간에 가까운 3D 지리공간을 자동적으로 구성한다. 제안한 방법을 실제 지역에 적용하여 제안한 지리 모델링 시스템의 효율성을 보인다.

  • PDF

Modelling of reinforced concrete flat slab-column connections for system-scale seismic analyses of high-rise buildings

  • T.Y. Yang;O. AlHarras;L. Tobber;O. Sargazi
    • Computers and Concrete
    • /
    • 제31권1호
    • /
    • pp.23-32
    • /
    • 2023
  • Reinforced concrete flat slab (RCFS) with columns is a standard gravity floor system for tall buildings in North America. Typically, RCFS-column connections are designed to resist gravity loads, and their contribution to resisting seismic forces is ignored. However, past experimental research has shown that RCFS-column connections have some strength and ductility, which may not be ignored. Advanced numerical models have been developed in the past to determine the nonlinear cyclic behavior of RCFS-column connections. However, these models are either too complicated for nonlinear dynamic analysis of an entire building or not developed to model the behavior of modern RCFS-column connections. This paper proposes a new nonlinear model suitable for modern RCFS-column connections. The numerical model is verified using experimental data of specimens with various material and reinforcement properties. A 40-story RC shear wall building was designed and analyzed to investigate the influence of RCFS on the global response of tall concrete buildings. The seismic responses of the building with and without the RCFS were modelled and compared. The results show that the modelling of RCFS has a significant impact on the inter-story drifts and force demands on both the seismic force-resisting and gravity elements.

잔골재율 변화에 따른 콘크리트 건조수축 모델링에 관한 연구 (A Study on Modelling for Prediction of Concrete Drying Shrinkage according to Aggregate Ratio of Concrete)

  • 박도경;윤여완;김광서
    • 한국건축시공학회지
    • /
    • 제4권4호
    • /
    • pp.71-77
    • /
    • 2004
  • Drying Shrinkage has much complexity as it has relations with both internal elements of concrete and external factors. Therefore, experiments on Concrete Drying Shrinkage are carried out in this study under simplified circumstances applying temperature & Humidity test chamber which enables constant temperature and humidity. Comparative analyses have been made respectively according to the consequences aiming at modelling for prediction of Concrete Drying Shrinkage and making out measures to reduce it. Strain Rate of Drying Shrinkage of concrete under the condition of dry air appears to rise by about 20%-30% in proportion as the temperature rises $5^{\circ}C$ when the humidity was held below 10% compared under the condition of dry temperature & Humidity test chamber. Strain Rate of Drying Shrinkage in pit sand concrete increased 20% higher than measured when in river sand under the condition of 90-day material age. A general formula with two variables is derived as follow ${\varepsilon}={\alpha}_1+{\beta}_1x_1+{\beta}_2x_2+{\beta}_3x_1^2+{\beta}_5x_2^2$. and also graphed in 3 dimensions, enabling to apply to actual design and predict Strain Rate of Drying Shrinkage in concrete. The results of prediction of Rate of Drying Shrinkage by Response Surface Analysis are as follows. The coefficient of correlation of Drying Shrinkage in Concrete was over 90%.

Robust finite element model updating of a large-scale benchmark building structure

  • Matta, E.;De Stefano, A.
    • Structural Engineering and Mechanics
    • /
    • 제43권3호
    • /
    • pp.371-394
    • /
    • 2012
  • Accurate finite element (FE) models are needed in many applications of Civil Engineering such as health monitoring, damage detection, structural control, structural evaluation and assessment. Model accuracy depends on both the model structure (the form of the equations) and the model parameters (the coefficients of the equations), and can be generally improved through that process of experimental reconciliation known as model updating. However, modelling errors, including (i) errors in the model structure and (ii) errors in parameters excluded from adjustment, may bias the solution, leading to an updated model which replicates measurements but lacks physical meaning. In this paper, an application of ambient-vibration-based model updating to a large-scale benchmark prototype of a building structure is reported in which both types of error are met. The error in the model structure, originating from unmodelled secondary structural elements unexpectedly working as resonant appendages, is faced through a reduction of the experimental modal model. The error in the model parameters, due to the inevitable constraints imposed on parameters to avoid ill-conditioning and under-determinacy, is faced through a multi-model parameterization approach consisting in the generation and solution of a multitude of models, each characterized by a different set of updating parameters. Results show that modelling errors may significantly impair updating even in the case of seemingly simple systems and that multi-model reasoning, supported by physical insight, may effectively improve the accuracy and robustness of calibration.

잔골재 특성에 따른 콘크리트 건조수축 모델링에 관한 연구 (A Study on Modelling for Prediction of Concrete Drying Shrinkage according to Properties of Aggregate)

  • 박도경;양극영
    • 한국건축시공학회지
    • /
    • 제6권1호
    • /
    • pp.73-77
    • /
    • 2006
  • Drying Shrinkage has much complexity as it has relations with both internal elements of concrete and external factors. Therefore, experiments on Concrete Drying Shrinkage are carried out in this study under simplified circumstances applying temperature & Humidity test chamber which enables constant temperature and humidify. Comparative analyses have been made respectively according to the consequences aiming at modelling for prediction of Concrete Drying Shrinkage and making out measures to reduce it. As a result Strain Rate of Drying Shrinkage of concrete was measured to increase by average $10{\times}10^{-5}$ in proportion to additional 4% increase in fine aggregate ratio, when water/cement ratio constant. Strain Rate of Drying Shrinkage in pit sand concrete increased 20% higher than measured when in river sand under the condition of 90-day material age. 6. Strain Rate of Drying Shrinkage in sea sand concrete increased $10%{\sim}15%$ higher than measured when in river sand. The results of prediction of Rate of Drying Shrinkage by Response Surface Analysis are as fellows. The coefficient of correlation of Drying Shrinkage in concrete was over 90%.

철근 콘크리트 벽식 구조물의 비선형 해석모델 (Nonlinear Analysis Model of RC Shear Wall Building)

  • 정일영;이영욱
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1993년도 봄 학술발표회논문집
    • /
    • pp.141-148
    • /
    • 1993
  • In this paper, TVLEM is selected for the shear wall model which was proposed by Kabeyasawa and the characteristics of spring models composing TVLEM was studied. In axial stiffness spring model, the horizontal displacements when Kabeyasawa model and simple axial stiffness hysteresis model were used, were closely similar. When the large shear-displacement was occured, stiffness degrading model was more adquate to the shear wall modelling than OOHM. Also for the purpose of modelling the horizontally continuous wall, the seperational method for TVLEM was used. The results of nonlinear analysis by this method were closely similar to experimental results .

  • PDF

Scaling methods for wind tunnel modelling of building internal pressures induced through openings

  • Sharma, Rajnish N.;Mason, Simon;Driver, Philip
    • Wind and Structures
    • /
    • 제13권4호
    • /
    • pp.363-374
    • /
    • 2010
  • Appropriate scaling methods for wind tunnel modelling of building internal pressures induced through a dominant opening were investigated. In particular, model cavity volume distortion and geometric scaling of the opening details were studied. It was found that while model volume distortion may be used to scale down buildings for wind tunnel studies on internal pressure, the implementation of the added volume must be done with care so as not to create two cavity resonance systems. Incorrect scaling of opening details was also found to generate incorrect internal pressure characteristics. Furthermore, the effective air slug or jet was found to be longer when the opening was near a floor or sidewall as evidenced by somewhat lower Helmholtz frequencies. It is also shown that tangential flow excitation of Helmholtz resonance for off-centre openings in normal flow is also possible.

Pedestrian level wind speeds in downtown Auckland

  • Richards, P.J.;Mallinson, G.D.;McMillan, D.;Li, Y.F.
    • Wind and Structures
    • /
    • 제5권2_3_4호
    • /
    • pp.151-164
    • /
    • 2002
  • Predictions of the pedestrian level wind speeds for the downtown area of Auckland that have been obtained by wind tunnel and computational fluid dynamic (CFD) modelling are presented. The wind tunnel method involves the observation of erosion patterns as the wind speed is progressively increased. The computational solutions are mean flow calculations, which were obtained by using the finite volume code PHOENICS and the $k-{\varepsilon}$ turbulence model. The results for a variety of wind directions are compared, and it is observed that while the patterns are similar there are noticeable differences. A possible explanation for these differences arises because the tunnel prediction technique is sensitivity to gust wind speeds while the CFD method predicts mean wind speeds. It is shown that in many cases the computational model indicates high mean wind speeds near the corner of a building while the erosion patterns are consistent with eddies being shed from the edge of the building and swept downstream.