Determining the Maximum Capacity of a Small Wind Turbine System Considering Live Loads of Buildings (건물의 활하중을 고려한 소형풍력발전시스템의 최대 설비용량 선정기법)

  • Lee, Yeo-Jin;Kim, Sung-Yul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.3
    • /
    • pp.165-170
    • /
    • 2016
  • Due to environmental issues such as global warming, the reduction of greenhouse gas emissions has become an inevitable measure to be taken. Among others, the building sector accounts for 50% of total carbon dioxide emissions, which is significantly high. Therefore, in order to reduce carbon dioxide emissions of the buildings, improving the energy efficiency by utilizing wind power among renewable energy sources is recommended. In case of buildings in the planning stage, it is possible to take the load of wind power generation systems into consideration when determining installed capacity. Already completed buildings, however, should be connected to small wind electric systems according to the live loads of the buildings based on the architectural design criteria. In order to connect to a building that has already been completed, it is necessary to consider the load of the small wind electric system as well as the live load of building. In addition, we need to generate the maximum electricity possible by determining the maximum installed capacity in a small area. In this paper, we propose the method for determining maximum capacity for building integrated small wind electric systems, which takes into account the considerations associated with connecting small wind electric systems to completed buildings. This can be developed into a system linked to solar power, which makes it possible to improve the energy independence of the building. In addition, carbon dioxide reduction by improving energy efficiency is expected.

Wind load estimation of super-tall buildings based on response data

  • Zhi, Lun-hai;Chen, Bo;Fang, Ming-xin
    • Structural Engineering and Mechanics
    • /
    • v.56 no.4
    • /
    • pp.625-648
    • /
    • 2015
  • Modern super-tall buildings are more sensitive to strong winds. The evaluation of wind loads for the design of these buildings is of primary importance. A direct monitoring of wind forces acting on super-tall structures is quite difficult to be realized. Indirect measurements interpreted by inverse techniques are therefore favourable since dynamic response measurements are easier to be carried out. To this end, a Kalman filtering based inverse approach is developed in this study so as to estimate the wind loads on super-tall buildings based on limited structural responses. The optimum solution of Kalman filter gain by solving the Riccati equation is used to update the identification accuracy of external loads. The feasibility of the developed estimation method is investigated through the wind tunnel test of a typical super-tall building by using a Synchronous Multi-Pressure Scanning System. The effects of crucial factors such as the type of wind-induced response, the covariance matrix of noise, errors of structural modal parameters and levels of noise involved in the measurements on the wind load estimations are examined through detailed parametric study. The effects of the number of vibration modes on the identification quality are studied and discussed in detail. The made observations indicate that the proposed inverse approach is an effective tool for predicting the wind loads on super-tall buildings.

Feasibility of using biogas in a micro turbine for supplying heating, cooling and electricity for a small rural building

  • Rajaei, Gh.;Atabi, F.;Ehyaei, M.A.
    • Advances in Energy Research
    • /
    • v.5 no.2
    • /
    • pp.129-145
    • /
    • 2017
  • In this study, the use of a micro gas turbine system using biogas to supply heating, cooling and electricity loads of a rural building located in rural area around Tehran has been studied. Initially, the amount of energy needed by the farmhouse was calculated and then the number of needed microturbines was determined. Accordingly, the amount of substances entering biogas digester as well as tank volume were determined. The results of this study showed that village house loads including electrical, heating and cooling and hot water loads can be supplied by using a microturbine with a nominal power of 30 kW and $33.5m^3/day$ of biogas. Digester tank and reservoir tank volumes are $67m^3$ and $31.2m^3$, respectively. The cost of electricity produced by this system is 0.446 US$/kWh. For rural area in Iran, this system is not compatible with micro gas turbine and IC engine system use urban natural gas due to low price of natural gas in Iran, but it can be compatible by wind turbine, photovoltaic and hybrid system (wind turbine& photovoltaic) systems.

Driving Burj Dubai Core Walls with an Advanced Data Fusion System.

  • Cranenbroeck, Joel Van;Hayes, Douglas McL;Sparks, Ian R
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.465-469
    • /
    • 2006
  • In recent years there has been considerable interest in the construction of super high-rise buildings. From the prior art, various procedures and devices for surveys during and after the phase of erection of a high-rise building are known. High-rise buildings are subject to strong external tilt effects caused, for instance, by wind pressures, unilateral thermal effects by exposure to sunlight, and unilateral loads. Such effects are a particular challenge in the phase of construction of a high-rise building, in as much as the high-rise building under construction is also subject to tilt effects, and will at least temporarily lose its - as a rule exactly vertical - alignment. Yet construction should progress in such a way that the building is aligned as planned, and particularly so in the vertical, when returning into an un-tilted basic state.It is essential that a straight element be constructed that theoretically, even when moving around its design centre point due to varying loads, would have an exactly vertical alignment when all biasing conditions are neutralised. Because of differential raft settlement, differential concrete shortening, and construction tolerances, this ideal situation will rarely be achieved. This paper describes a procedure developed by the authors using GPS observations combined with a network of precision inclination sensor to provide reliable coordinated points at the top of the worldwide highest-rise building under construction in Dubai.

  • PDF

A Study on the Estimation of Temperature, Humidity and Cooling Load (온도, 습도 및 냉방부하 예측에 관한 연구)

  • Yoo, Seong-Yeon;Han, Seung-Ho;Lee, Je-Myo;Han, Kyou-Hyun;Noh, Kwan-Jong
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.80-85
    • /
    • 2006
  • The peak demand of electricity in summer season mainly comes from the day time cooling loads. Ice thermal Storage System (ITSS) uses off-peak electricity at night time to make ice for the day time cooling. In order to maximize the use of cold storage in ITSS, the estimation of day time cooling load for the building is necessary. In this study, we present a method of cooling load estimation using 5 years of normalized outdoor temperature, relative humidity, and the building construction data. We applied the hourly-based estimation to a general hospital building with relatively less sudden heat exchange and the results are compared with the measured cooling load of the building. The results show that the cooling loads estimation depends on the indoor cooling design temperature of the building.

  • PDF

Application of Response Spectrum Method for Analysis of a Floor System Subjected to Dynamic Loads on Multiple Locations (복수 절점에 가진되는 건물 바닥판의 해석을 위한 응답스펙트럼 해석법의 응용)

  • 김태호;이동근
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.1
    • /
    • pp.21-32
    • /
    • 2002
  • In general, the response spectrum analysis method (R.S.A) is widely used for seismic analysis of building structure. But, it is not common to apply R.S.A for the analysis of structural vibration caused by dynamic loads of equipments, machines and moving leads, etc. The time history analysis method(T.H.A) for the vibration analysis, compared with R.S.A, is very complex, difficult and time consuming. So the application of R.S.A, that is convenient to calculate maximum responses for structural vibration, is proposed in this study. At first, the procedure for the application of the R.S.A to calculate of the maximum vibration response induced by dynamic load applied on the single point is described. And then, the process, which can save the time and the memory for calculation of the maximum vibration response induced by dynamic loads on the multi-point is proposed, and the maximum structural response caused by moving loads are obtained. Lastly, the accuracy of the proposed method is verified by comparing the results of R.S.A to T.H.A for some example models.

Assessment of ASCE 7-10 for wind effects on low-rise wood frame buildings with database-assisted design methodology

  • He, Jing;Pan, Fang;Cai, C.S.
    • Wind and Structures
    • /
    • v.27 no.3
    • /
    • pp.163-173
    • /
    • 2018
  • The design wind pressure for low-rise buildings in the ASCE 7-10 is defined by procedures that are categorized into the Main Wind Force-Resisting System (MWFRS) and the Components and Cladding (C&C). Some of these procedures were originally developed based on steel portal frames of industrial buildings, while the residential structures are a completely different structural system, most of which are designed as low-rise light-frame wood constructions. The purpose of this study is to discuss the rationality (or irrationality) of the extension of the wind loads calculated by the ASCE 7-10 to the light-frame wood residential buildings that represent the most vulnerable structures under extreme wind conditions. To serve this purpose, the same approach as used in the development of Chapter 28 of the ASCE 7-10 that envelops peak responses is adopted in the present study. Database-assisted design (DAD) methodology is used by applying the dynamic wind loads from Louisiana State University (LSU) database on a typical residential building model to assess the applicability of the standard by comparing the induced responses. Rather than the postulated critical member demands on the industrial building such as the bending moments at the knee, the maximum values at the critical points for wood frame buildings under wind loads are used as indicators for the comparison. Then, the critical members are identified through these indicators in terms of the displacement or the uplift force at connections and roof envelope. As a result, some situations for each of the ASCE 7 procedures yielding unconservative wind loads on the typical low-rise residential building are identified.

Analysis of Effects of Building Energy Consumption Characteristics on the Optimization Ratio for New and Renewable Energy Systems (건물에너지사용특성이 신재생에너지시스템 최적화 비율에 미치는 영향분석)

  • Lee, Yong-Ho;Hong, Jun-Ho;Kim, Yong-Kyoung;Cho, Young-Hum;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.5
    • /
    • pp.117-126
    • /
    • 2014
  • This study developed a KRESS program designed to find the optimization ratio for new and renewable energy systems and analyze the effects of building energy consumption characteristics on the ratio. In spite of clear differences in predicted energy consumption and energy consumption by the loads among 18 facilities, the current formula for obligatory supply ratios applies a correction coefficient according to the building purposes based on energy consumption per each unit area in medical facilities and thus reflects no energy consumption characteristics according to the building purposes. The optimization ratio for new and renewable energy systems was the same for all facilities when the correction coefficients by the building purposes and new and renewable energy sources were all applied. When the correction coefficients were not applied, however, the optimization ratio varied according to building energy consumption characteristics. The findings raise a need to test the correction coefficients in order to select new and renewable energy systems that take into account energy consumption characteristics by the building purposes and loads and reflect economy, environmental performance, and technology.

Comparison on Heating & Cooling Loads Analysis in Buildings with Modified Bin Method (수정(修正)빈법(法)에 의한 건물(建物)의 기간(期間) 열부하(熱負荷) 해석(解析)에 관한 비교(比較) 연구(硏究))

  • Sohn, J.Y.;Yoon, D.W.;Yee, J.J.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.6
    • /
    • pp.675-685
    • /
    • 1988
  • The purpose of this paper is to present the fundamental information for setting up more accurate and easier heat loads analysis method by examing and comparing Modified Bin Method with Dynamic loads calculation and Extended Degree Day Method. For this comparison, monthly and annual loads calculation are performed in perimeter zones of model office building in Seoul by the above each Method. The results of Modified Bin Method are approximated to those of Dynamic loads calculation Method, and the correlations of the methods are specifically described in this paper.

  • PDF

A Modified Equivalent Frame Model for Flat Plate Slabs Under Combined Lateral and Gravity Loads (조합하중시의 플랫 플레이트 슬래브 시스템에 대한 수정된 등가골조 모델)

  • Oh, Seung-Yong;Park, Young-Mi;Han, Sang-Whan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.369-372
    • /
    • 2006
  • Flat plate slab systems have been commonly used as a gravity force resisting systems, which should be constructed with lateral force resisting systems such as shear walls and moment resisting frame. ACI 318(2005) allows the Direct design method, the equivalent frame method (ACI-EFM) under gravity loads and the finite-element models, effective beam width models and equivalent frame models under lateral loads. ACI-EFM can be used for gravity loads as well as lateral loads analysis. But the method may not predict the behavior of flat plate slabs under lateral loads. Thus Previous study developed a Modified equivalent frame method(Modified-EFM) which could give more precise answer for flat plate slab under lateral loads. This study is to verified the accuracy of a Modified-EFM under combined lateral and gravity loads. The accuracy of this model is verified by comparing the results using the Modified-EFM with the results of finite element analysis. For this purpose, 7 story building is considered. The analysis results of other existing models are included. The analysis results show that Modified-EFM produces comparable drift and slab internal moments with those obtained from finite element analysis.

  • PDF