• Title/Summary/Keyword: building fire safety

Search Result 642, Processing Time 0.027 seconds

A Study on the Necessary Spaces and Area Standards of Integration Facility for Early Childhood Education and Care (영유아 교육·보육 통합시설의 필요 공간과 면적기준에 관한 연구)

  • Cho, Jin Il;Choi, Hyeong Ju
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.17 no.2
    • /
    • pp.22-37
    • /
    • 2018
  • This study suggests desirable disaster safety education curriculum through analyzing the operational status of the school disaster safety management training course and demand survey of school staff. First, the problem of the disaster safety training course of the school is not connected with the lack of law and system and the school disaster safety job. Second, improvement of law and system and variety of training should be made to acquire professional knowledge. Third, it is necessary to divide curriculum into the following four categories, according to educational needs of public officials ; Educational administration officers course focused on facility safety, maintenance and disaster countermeasure. Educational officials in technical post course addressing approval and permission of school facility projects, seismic reinforcement of school building, etc. Educational supervisors course covering roles and responsibilities of the school safety supervisors in the event of disaster. Teaching staffs course focused on safety instructions for students. Fourth, it is found that lectures and experiential learning methods are the most desirable methods of teaching and learning, and the major ranks are earthquake disaster, fire, gas, typhoon, school road, and electrical safety.

Comparison of Evacuation Efficiency for Stair Width and Code for Occupant Load Calculation in High-rise Buildings (고층의 주상복합건축물 계단폭과 수용인원 산정기준에 따른 피난효율의 비교)

  • Lee, Yang-Ju;Ko, Kyoung-Chan;Park, Woe-Chul
    • Fire Science and Engineering
    • /
    • v.25 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • An evacuation simulation was carried out to confirm evacuation efficiency for stair width and problems in calculation of occupant load for high-rise buildings. The evacuation time and number of evacuated persons from a 39 story condominium-mercantile building were calculated by using Simulex for stair widths of 1.2 m, 1.5 m, and 1.8 m. The total occupant load based on the Korean code was higher than the number of actual residents by 2.3 times, and that based on the NFPA 101 Life Safety Code by 2.6 times, respectively. For the occupant load based on the Korean code, smaller stair width resulted in lower evacuation efficiencies due to bottlenecks in egress. For the actual residents and NFPA code-based occupant load, a high evacuation efficiency and negligible effects of the stair width on evacuation efficiency were confirmed. It was shown that there was a bottleneck even at the stair width of 1.8 m for the Korean code-based occupants, while the stair width of 1.2 m provided safe egress to the actual residents or NFPA code-based occupants. This recommended further studies on possibility of lowering the level of the Korean code in calculation of the occupant load.

Floor Impact Sound Pressure Level Characteristics by the Change of Reverberation Time in Mock-up Test Rooms (수음실 잔향시간 변화에 따른 중량 충격음 레벨 특성 - 실험실 환경을 중심으로 -)

  • Jeong, Jeong Ho;Lee, Byung Kwon;Yeon, Jun Oh;Jeon, Jin Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.4
    • /
    • pp.339-347
    • /
    • 2014
  • Floor impact sound in high-rise apartment building became one of social problems. A lot of civil complaints on floor impact sound occur continuously and the number of disputes between neighbors in small and aged apartment buildings is increasing. Interests on heavy-weight impact sound pressure level measurement and evaluation method is increased. Previous study reported that heavy-weight impact sound level was changed by the sound field condition of receiving reverberation chamber. In this study, heavy-weight impact sound pressure level change by the receiving sound field condition was measured in standard test facility and mock-up test room. These two experimental conditions were designed to simulate averaged living room of common apartment units. By the change of sound absorption power in receiving room, heavy-weight impact sound pressure level in most of frequency bands were changed in standard test facility and mock-up room. Normalized maximum sound pressure level regulated in ISO 16032 showed wider range of heavy/soft impact sound pressure level. Heavy/soft impact sound pressure level change was became smaller by the application of standardized maximum sound pressure level and ISO/CD 10140-3 Amd 2 method. In the case of standardized maximum sound pressure level, absolute sound pressure level changed. From these results, receiving sound field correction method regulated in ISO/CD 10140-3 Amd 2 is needed for the precision measurement and evaluation of heavy-weight impact sound.

An Experimental Study on the Pressure Change in the Type of Elevator Hoistways (엘리베이터 승강로 형식별 압력변동에 관한 실험 연구)

  • Kim, Hak-Joong;Kim, Boem-Gyu;Park, Yong-Hwan;Lim, Chae-Hyun
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.139-144
    • /
    • 2010
  • Recently, evacuation safety of building resident become the major concern, as the building has been higher and more complicated. Many high-rise multi use buildings are under construction in Korea. Required evacuation time using stairway is longer in high-rise buildings, moreover it is impossible for the disabled to evacuate by using stairway. For this reason the study on the effectiveness of using elevator for evacuation is progressing. This study shows the pressure change in various types of hoistway when elevator is moving. Experiments were performed in 4 different types of hoistway, and showed big difference in pressure change between the type of hoistway. The pressure change in single hoistway that have one car is bigger than that in multi hoistway that have multi cars. The results of this study can be used for the study of elevator piston effect as basic data.

A Study on the Assessment of Hazardous Properties of the Oxidizing Solids (산화성고체의 위험성평가에 관한 연구)

  • Lee, Bong-Woo;Park, Chul-Woo;Song, Haak
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.9-16
    • /
    • 2009
  • Chemical products have had an favorable influence on our everyday life, and contributed very much to the development of human culture. According to the rapid change of industry and the development of scientific technique the using chemical products are increasing more and more. Chemical products can have any hazardous property such as flammability or explosiveness. There are occurring many accidents in the international trade due to the different classification and labelling of chemicals produced in various countries. The main purpose of this work is the development of global standard test methods for the chemicals, and the classification and labelling in building block approach by means of the basic technical data. Oxidizing solids, combustible solids, spontaneously combustible materials, water-prohibitive materials, flammable liquids, self-reactive materials and oxidizing liquids have been classification The first Experiment have tested Oxidizing solids of third five. The results have been classified according to the hazard material safety regulation and the UN regulation, and summarized in a data-base.

The Counterflow Speed and Density of a Fire fighter in Corridor (복도에서 소방관에 의한 카운터플로우 발생 시 밀도와 속도 측정)

  • Kim, Woon-Hyung;Kim, Heung-Youl;Joung, Woo-In;Kim, Jong-Hoon
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.1
    • /
    • pp.76-83
    • /
    • 2019
  • Purpose: The purpose of this study is to present data of density and speed through the experiment of the counterflow by firefighter in corridor. Method: Experimental setup including a corridor in building was prepared for measuring data with 1.5m and 2m width. Normal flow and counterflow were created for each. Data were measured using camera and acquired by video image analysis. Results: The counterflow in corridor resulted in increasing average density of about $0.55P/m^2$ and decreasing average movement speed of about 0.61 m/s. These data measured during the time when the counterflow occurred. Conclusion: It was found that counterflow by firefighter in corridor momentary increasing the density and decreasing walking speed of evacuee. Further experiments of the counterflow effect in the total evacuation time are needed.

A Study on the Procedure of Quantitative Risk Assessment for High Pressure Natural Gas Pipeline (도시가스 고압배관의 정량적 위험평가 절차에 관한 연구)

  • Lee, Kyung-Sik;Jo, Young-Do;Ryou, Young-Don;Ko, Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.25-31
    • /
    • 2008
  • Recently risk management based on a quantitative assessment is considered to improve the level of safety in Korea. This paper focuses on the procedure of the quantitative risk assessment for natural gas pipelines. For that purpose, the methods to estimate failure frequency based on failure causes from European Gas Pipeline Incident Data Group and BG Transco, to analyze consequence caused by fire, and to calculate individual risk and societal risk have been proposed systematically in this paper. Risk criteria of individual risk and societal risk have been proposed by considering the environment of pipeline route in Korea. The proposed procedure of quantitative risk assessment may be useful for risk management during the planning and building stages of a new pipeline, and modification of buried pipeline.

  • PDF

A Suitability Analysis on the legal standards of the Rural Housing Standard Plans (농촌주택 표준설계도의 관련 법적 기준에의 적합성 분석 연구)

  • Jeon, Young-Hoon;Shin, Doo-Sik
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.15 no.4
    • /
    • pp.1-8
    • /
    • 2013
  • The Rural Housing Standard Plans for improving the quality of life and housing stability in rural areas has been developed 87 types from 1994 to 2012. However, some types of Plans do not satisfy the current legal standard in accordance with social and legal changes. Standard plans has the same effect as a building permit, and replace it, so legal suitability of Plans is an important. Therefore, it is required the suitability analysis on the legal standards of Rural Housing Standard Plans. The Purpose of this study is to derive improper types and items of the Rural Housing Standard Plans on the legal standards. In this study, we analyzed its suitability on the legal standards(law on fire-fighting system installation and safety management, energy saving design criteria for buildings, structural checklist for small buildings, the types of drawing for building permit) in accordance with "rules for the operation of standard plans". And we analyzed the utilization of the Rural Housing Standard Plans through downloads from welchon portal.

Constructability of a Waterproofing Sheet Joint Combining an Aluminum Thin-film and Viscosity Layer Using a High-frequency Inductive Heating Apparatus (고주파 유도가열 장치를 이용한 알루미늄 박판 점착 복합방수시트 조인트부의 시공성)

  • Chang, Sang Mook;Kim, Yun Ho;Choi, Sung Min
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.2
    • /
    • pp.163-169
    • /
    • 2014
  • Engineers in the construction field have been using bonded waterproofing sheets in an attempt to resolve the imbalance in the quality, the risk of fire, safety of workers, and environmental pollution, as well as to eliminate separate use of organic adhesives on the surface of concrete. Recently, self-laminated waterproofing sheets have been developed. The purpose of this research is to find an appropriate processing speed according to the changes in physical properties, and visual observation of the waterproofing sheets laminated by the aluminum thin-film and viscosity layer that can be attached through self-adhesiveness on the surface of concrete and waterproofing sheets. Therefore, this research is conducted using a physical performance test. Based on the result of the test, when the high-frequency inductive heating apparatus was used, an improved adhesion and bonding stability effect were confirmed after the anti-hydrostatic pressure and bond strength in the temperature condition, and the surface observation in the processing speed condition.

A Study on Improvement of Evacuation Safety at Daycare Center (어린이집 피난안전 향상에 관한 연구)

  • Jin, Seung-Hee
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.63-73
    • /
    • 2017
  • As more and more the number of a couple working together for living has increased and an interest in early education has risen, daycare centers have made an effort to provide effective and good service beyond 'nursery care'. The most important thing in building in the event of disasters is safe evacuation of occupants. Having 'safe evacuation route' is required to reduce damage caused by disasters, It is necessary to give continuous and repeated training for right evacuation to infant and children so that they can evacuation successfully. This study examined problems that need improvement so that evacuation instrument installed in daycare centers can be used better by analyzing a survey of evacuation related facilities on daycare centers. This study found that laws and regulations on safety should be improved, evacuation facilities prepared against should be maintained regularly by relevant authorities, training for coping with disasters should be provied and evacuation instruments which are suitable for children.