• 제목/요약/키워드: building fire safety

검색결과 650건 처리시간 0.037초

물류창고의 배연설비 기준 개선을 위한 국내·외 배연설비의 설계 방법에 따른 연기하강시간 예측에 관한 연구 (A Study on the Prediction of Descending Smoke Time according to the Design Method of Domestic and Foreign Smoke Facilities for the Improvement of Smoke Facilities Standards in Logistics Warehouse)

  • 허예림;김윤성;진승현;구인혁;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.141-142
    • /
    • 2022
  • Recently, fires in logistics warehouses in Korea are continuously increasing. In addition, the need for fire safety in logistics warehouses is emerging. So, it is believed that it is necessary to establish standards for vent facilities under effective smoke control for the evacuation safety of residents in logistics warehouses. Therefore, this paper compares the standards related to combustion facilities in Korea, the United States, and Japan, and applies the design method to logistics warehouses of domestic materials to predict smoke drop time and use it as a basic data for improving domestic smoke facilities standards.

  • PDF

탄소중립 확보를 위한 친환경 동절기 대체 열원 성능 검증 (Performance Verification of Curing Method in Cold-Weather with Using Energy Saving Electronic Heater for achieving Korean Carbon Neutra)

  • 조만기;김상균;홍성민;박종훈
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.192-193
    • /
    • 2021
  • Recently, the need to strengthen the Air Environment Conservation Act and secure alternative heat sources during the winter by carbon neutrality policies has been raised. Accordingly, winter construction, which has safety and quality measures, is emerging as an essential factor. It is believed that eco-friendly tropical type electric hot air heaters will be able to solve most of the problems of winter construction at construction sites, especially prevention of suffocation and fire accidents. In addition, as a result of on-site performance verification, it has secured more than the same performance as the existing curing method, and the curing technology can create an eco-friendly and pleasant working environment while considering safety and construction.

  • PDF

고양종합터미널화재 시 소방시설의 작동실태 분석 (Analysis of the Working Conditions of Fire Protection Systems in the Goyang Bus Terminal Building Fire)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제32권3호
    • /
    • pp.95-107
    • /
    • 2018
  • 화재조사 결과를 토대로 고양종합터미널 건물 화재 시 소방시설 작동 실태를 분석하였다. 분석결과를 요약하면 다음과 같다. 첫째, 천장 우레탄폼에 불이 붙은 직후에 옥내소화전을 이용하여 진화할 수 있음에도 시도하지 않았다. 둘째, 지하1층 대수선공사 공간은 스프링클러 알람밸브를 잠가놓아 작동하지 않았지만, 지하2층과 지상1층, 지상2층, 지상3층은 스프링클러가 작동하여 지하1층 대수선공사 공간 이외의 층으로의 화재확산을 저지하였다. 셋째, 피난유도등은 정상 작동하였지만, 터미널 2층 대합실에서 승차장 쪽으로 통하는 출구(비상구)에 피난구유도등이 설치되어 있지 않아 터미널 2층에서 다수의 사상자가 발생하게 하는데 영향을 미쳤다. 넷째, 화재수신기에서 제연설비 배기 팬 제어반에 전기신호를 보냈지만 배기 팬의 제어반에서 수동으로 취급하여 터미널 2층 제연설비 배기 팬이 작동하지 않았다.

주택성능등급표시제도의 활성화를 위한 가변성 성능범주의 현황 및 개선방안연구 (A Study on Improvement of Flexibility for the Activation of the "Housing Performance Grading Indication System")

  • 이성옥;김수암
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2008년 추계학술발표대회 논문집
    • /
    • pp.479-482
    • /
    • 2008
  • The purpose of this study is a proposal about the flexibility of the performance category to revitalize the "Housing Performance Grading Indication System". This system consists of 5 main performance parts, 14 performance categories and 20 detailed performance lists. 5 main performance parts are Noise and Acoustics(Light-weight impact sound control, heavy-weight impact sound control, sound control of toilet, sound control of party wall), Long-life(flexibility, remodeling & maintenance, durability), Landscape & Indoor Environment(landscape, formaldehyde control& ventilation, daylighting, thermal environment), Welfare & Barrier-free(playground and community center, welfare space, barrier-free design), Fire Safety(fire safety, safe place, fire-resisting quality). The flexibility of the performance category is conformed to Long-life housing related grading and can realize the Long-life housing in response to resident needs about the space rearrangement. Now, The flexibility of the performance category is limited to the evaluation of the private space, that is, the Skeleton evaluation. This study would suggest alternatives to improve uppermost limits through analyzing 60 examples from January 9th 2009 to October 30th 2008. The flexibility of the performance category is possible to estimate not only the Skeleton evaluation but also the Infill evaluation in response to social changes.

  • PDF

밀폐공간내 화재에 의해 생성된 연소가스 분석 및 유동에 관한 연구 (A study on the Analysis of Combustion Gas and its Flow Induced by Fire in an Enclosure)

  • 추병길;조성곤
    • 한국안전학회지
    • /
    • 제12권1호
    • /
    • pp.77-93
    • /
    • 1997
  • The natural convection and combined heat transfer induced by fire in a rectangular enclosure is numerically studied. The model for this numerical analysis is partially opened, it is divided by a vertical baffle projecting from ceiling. The solution procedure Includes the standard k- $\varepsilon$ model for turbulent flow and the discrete ordinates method (DOM ) is used for the calculation of radiative heat transfer equation. In this study, numerical simulation on the combined naturnal convection and radiation is carried out in a partial enclosure filled with absorbed-emitted gray media, but is not considered scattering problem. The velocity vectors, streamlines, and isothermal lines are compared the results of pure convection with those of the combined convection-radiation, the combined heat transfer. Comparing the results of pure convection with those of the combined convection-radiation, the combined heat transfer analysis shows the stronger circulation than those of the pure convection. Three different locations of heat source are considered to observe the effect of heat source location on the heat transfer phenomena. As the results, the circulation and the heat transfer In the left region from heating block are much more influenced than those in the right region. It is also founded that the radiation effect cannot be neglected in analyzing the building in fire.

  • PDF

건축물 화재에 따른 군중 피난 시뮬레이션 시스템 개발 (Development of Crowd Evacuation Simulation System for Building Fire)

  • 이동호;박종승;조준성;김정엽
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.304-309
    • /
    • 2008
  • 본 논문은 기존 기발된 재실자의 탈출 계획 및 예측 프로그램 개발에 대해 길 찾기를 위한 알고리즘으로는 Dijkstra 알고리즘, Best-First Search 알고리즘, Johnson 알고리즘 등이 있으며 가장 안정적으로 알고리즘 구현이 가능한 A*알고리즘을 적용하였다. 따라서, 본 개발 프로그램은 재실자가 대피 목적지를 향한 최적의 길 찾기를 이용하여 가장 가까운 거리에 있는 탈출구를 효율적으로 찾을 수가 있으며 재실자의 사실감 있는 대피 이동 동선의 구현을 위해 기존의 경직된 경로를 매끄럽게 구현하였다. 탈출구는 흐름율과 정체 반경을 적용하여 재실자가 탈출구에 밀집하였을 경우 병목 현상이 발생하도록 하여 대피현상이 실제 상황과 유사하도록 프로그램을 구축하였다. 본 대피프로그램은 실제 건물의 CAD도면을 import 가능하도록 구축함으로서 대피평가시간을 절약할 수 있도록 하였다.

  • PDF

지하연계복합건축물의 선큰 재실자밀도 분석 (The Occupant Load Density of Sunken Area in Multiple Occupancy Building with Underground Facility)

  • 김운형;김종성;이용재
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2013년도 춘계학술대회 초록집
    • /
    • pp.80-81
    • /
    • 2013
  • 최근 제정 시행되고 있는 지하연계 복합건축물에 대한 다양한 연구가 진행되고 있다. 그러나 화재위험성이 높은 지하 공간의 경우, 아직까지 관련 규정의 근거가 미약하여 현실적인 피난안전 설계에 어려움을 가지고 있다. 본 연구에서는 피난 계획을 위한 로우 데이터를 확보하고자 현재 사용 중인 선큰을 대상으로 실제 유동인구를 측정하여 재실자 밀도를 분석하였다. 선큰으로 연결되는 출입구들의 유동인구와 함께 유동계수를 측정하였으며 선큰내의 재실자 밀도 산정을 통하여 선큰의 대피기능을 위한 연구 진행의 토대를 마련하였다.

  • PDF

Smoke density chamber를 적용한 건축물 마감재의 연소가스 독성 평가 (A Study on the Toxicity of Closing material of building with chamber)

  • 이인구;조남욱;이봉재;이동호
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 춘계학술논문발표회 논문집
    • /
    • pp.248-251
    • /
    • 2011
  • 연소가스분석을 통한 건축물 마감재료의 연소독성평가를 위해 독성지수 계산법(NES 713)을 활용하여 독성평가를 수행하였다. 가연성 건축재료(우레탄, 고무바닥재)를 대상으로 독성가스를 측정하기 위해 ISO19702에서 규정하는 FT-IR(퓨리에변환적외선분광분석기)을 이용하였으며, 화재 모델은 ISO5659의 Smoke Density Chamber를 사용하였다. 독성지수를 산정하기 위해 Cf(사람이 30분간 노출시에 사망할 수 있는 가스의 농도)를 기준으로 하였다. 본 연구를 통해 연소가스 독성지수 연구의 기초연구자료로 활용하고자 한다.

  • PDF

U-건물 화재안전 교육 시스템 구축에 관한 연구 (A Study on the construction for the U-building fire safety education system)

  • 김경식;노삼규;함은구;김동철;김현주
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 추계학술논문발표회 논문집
    • /
    • pp.23-26
    • /
    • 2011
  • U-러닝은 유비쿼터스러닝(Ubiquitous Learning)의 약자로 개방적 학습자원을 학습자의 필요에 따른 선택에 의해 활용하는 통합적 학습체제 의미한다. 국내에서의 소방교육은 다양한 소방교육 컨텐츠부족 및 시간적 공간적 제약으로 인해 소방안전에 대한 교육이 원활히 이루어지지 못하고 있는 실정이다. U-Learning 구성하여 다양한 컨텐츠를 거주자, 근무자, 방화관리자에게 제공하여 자기주도적인 학습을 통해 평상시 거주자 및 근무자에게 소방시설의 이해 및 사용방법을 교육하고, 방화관리자에게는 소방시설의 관리 및 점검방법을 교육함으로써 화재 및 재난으로 인한 피해를 최소화 할 수 있다.

  • PDF

HOT-SMOKE TESTS IN TWO UNDERGROUND RAILWAY STATIONS WITH MOVING TRAINS

  • Allan, Hugh
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.472-476
    • /
    • 1997
  • Hot-smoke testing in Australia has progressed to the stage where there is an Australian Standard for these tests. The purpose of such tests is twofold: firstly they can validate computer modeling predictions for smoke movement, and secondly they can demonstrate that the smoke control systems and associated fire safety systems function satisfactorily. Hot-smoke tests were carried out in March 1997 at two of Sydney's underground railway stations, namely St James and Museum. The purpose of the tests was to demonstrate that the smoke control systems performed their functions as intended. Tests were carried out in the concourses and on the platforms, and trains ran during the tests so that the effect of moving trains on smoke movement could be observed. A total of five tests were carried out and video recordings were taken of each. This is the first time that hot-smoke tests have been carried out in an underground station with trains running. The paper discusses some of the interesting observations and the problems identified by the tests.

  • PDF