• Title/Summary/Keyword: building fire safety

Search Result 644, Processing Time 0.029 seconds

A Investigation Study on the Recommendation for the Evacuation Plan using Evacuation Elevator of AIJ (I) (일본건축학회의 화재 시 피난 엘리베이터를 이용한 피난계획 지침안(案)에 대한 조사 (I))

  • Kwon, Young-Jin;Yun, Yoo-Hyuk
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.3-6
    • /
    • 2008
  • Most elevators worldwide do not have smoke protection, fire protection, and other features necessary for them to be considered as a means of fire evacuation. It is the aim of this study to investigate and analyze the recommendation for the evacuation plan using evacuation elevator of AIJ the aim of this study is to introduce AIJ method for the safety plan using evacuation elevator of high rise building written by working group fire resistant.

  • PDF

Analysis of Causes of Casualties in Jecheon Sports Center Fire - Focus on Structural Factors of Building and Equipment - (제천 스포츠센터 화재의 다수 사상자 발생원인 분석 - 건물과 설비의 구조적인 요인을 중심으로 -)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.86-94
    • /
    • 2018
  • A sports center fire in Jecheon caused 29 deaths and 40 injuries. This study focused only on the structural factors of the building and equipment to investigate the causes of casualties based on the fire investigation results at the sports center. The structural factors of the building and equipment were a piloti-type parking lot, lack of a fire compartment between the piloti-type parking lot and lobby, lack of an installed sprinkler system, lack of an installed fire door in the main stairs on the $1^{st}$ floor, lack of an installed fire water tank on the rooftop, an installed pocket fire door in the main entrance on the $2^{nd}$ floor, poor fire compartments in an EPS space and a pipe pit and on each floor, a leak in the joint of a drain pipe, plywood installed in the hoistway of the freight elevator and interior wall, illegal remodeling of a closed rooftop structure, which cannot discharge smoke and heat, installed styrofoam insulation in the inside of the parking lot ceiling, an installed tempered glass window, which cannot be opened in the ladies bathroom on the $2^{nd}$ floor, and a finished dryvit exterior wall.

A Study on Development way of Fire fighting 119 angers of Jeju Islander (제주도민의 119화를 위한 소방의 발전방안)

  • Koh, Jae-Moon;Kim, Tae-Min;Kim, Hyo-Sik
    • The Korean Journal of Emergency Medical Services
    • /
    • v.7 no.1
    • /
    • pp.147-178
    • /
    • 2003
  • In terms of reinforcing the functions and services of rescue 119 and emergency corps, we must review the following considerations : Building up security system along with operational expansion, building up a system for emergency medical treatment, buliding up a comprehensive information management system for rescue and emergency, constructing a provincial safety museum and so forth. For the ways to better the works of rescue 119, we can review the following considerations : Improving the education for fire fighting trainging corps under Jeju Provicial Fire and disaster management department, providing rescue members with more opportunity for clinical practices, enhancing the morale of rescue members, installing a comprehensive briefing room for emergency rescue members, building up medical networks along with reasonable policies for information service, operating the consulting system for rescue 119 and so on. Provide little more superior quality high fire fighting service to jeju islander, and need long-term and elaborate research to correspond in rising fire fighting man-power demand newly and investment. Construction of well-matched disaster administration system is assignment that must hurry in international free city. That jejudo receives time factor about that is received for another thing area's number of persons or equipment when regional special quality large scale or disaster happens is that of course the support receives limitation immediately. Jeju fire fighting services is one story reform, specialization taking into account particular situation of jeju area to grow as sightseeing and center of culture intending international free city, should be upgraded. So, it may do big contribution naturally in jeju international free city phase that coincide jeju islander's social welfare promotion and safety desire.

  • PDF

The inspection and seismic design method of electrical facility instated in the building (건축물에 시설되는 수변전설비 내진설계 및 검사 방법에 관한 연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Kang, Min-Hee;Bae, Suk-Myong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.332-335
    • /
    • 2009
  • Incase of not considered seismic design at transformer vault which is made of many informant electrical facility, facility is damaged, electrical fire breaks out and second damage is able to break out at generating earthquake. But seismic design yet is not applied to at transformer vault in the country. Regard to seismic design method of electrical facility installed in the building internal, we present the seismic design of electrical facility using "Building construction design standard" in internal and "Manual of seismic design and construction for Building Electrical facility" in japan. This paper will be used detail seismic design of pipe and facility. reliability inspection plan for seismic design and construction of electrical facility

  • PDF

A Study on the Building Plan of Chemical Management System in Laboratory Using FGI Method (FGI 기법을 이용한 연구실에서의 화학물질관리시스템 구축 방안에 관한 연구)

  • Kim, Sang-Chul;Song, Young-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.18-25
    • /
    • 2017
  • Each country tries to prevent major industrial accidents at industrial sites, such as fire and explosion as well as poisoning incidents, and regulation of the management of chemicals is being enhanced in all sectors. In particular, in the case of laboratories, a variety of chemicals have been developed and handled in accordance with the development of science and technology. On the other hand, the accident probability at laboratories is higher than at industrial sites, because many different kinds of chemicals are handled in the laboratory but in very small amounts and chemical, physical, and biological studies have been carried out in limited spaces. Recently, the accident probability at laboratories was found to be higher as convergence/integration studies were carried out beyond the academic arena. Therefore, in this study, a survey of chemical management was conducted to prevent accidents due to chemicals targeting the laboratory safety coordinator using the FGI (focus group interview) method. The building plan of a chemical management system was suggested based on the results of the survey.

Analysis on Emergency Power Supplies in Buildings and a Model for Safe Operation of the Emergency Power System (건축물의 비상전원 적용실태 및 자가발전설비의 안전 운전 모델에 관한 연구)

  • Lee, Won-Kang;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.49-56
    • /
    • 2012
  • The purpose of this paper is to present a model for operating an emergency power system(EPS) that can secure a sufficient power supply used in case of a fire by analyzing the status of power supplies for emergency and firefighting operations. Investigations on the one of the causes of the operational failure of firefighting systems show evidence of EPS. Generally, when power to a building is interrupted, EPS supplies the emergency load(excepted firefighting load) first. When a power outage and a fire occur simultaneously, the EPS must be able to supply both the emergency load and the firefighting load, especially the firefighting load to the end. However, in order to save construction costs, emergency power generators in apartment, commercial, and business buildings can satisfy only one of the required loads. In cases like this, when a power outage and a fire occur simultaneously, there is a danger of firefighting equipment not operating due to insufficient power supply from the emergency generator. Therefore, an EPS must have a reserved firefighting power that can supply both the firefighting and the emergency load. Such EPS, when faced with a danger of an overload, will shut down the supply to all or part of the emergency load, thus securing a continuous power supply to the firefighting equipment. The generator power system with reserved firefighting power (RFP) will also have an indicator to show that the selective control is being used. General power generation systems for emergency load and firefighting load were found to have a demand factor of 50-60% with a lump. However, when installing an EPS, the builders must choose the higher demand factor suggested according to the official approval demand factor of the building.

Enhancing the Fire Performance of Concrete-Filled Steel Columns through System-Level Analysis

  • Fike, R.S.;Kodur, V.K.R.
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.1
    • /
    • pp.11-21
    • /
    • 2013
  • The use of concrete filling offers a practical alternative for achieving the required stability of steel Hollow Structural Section (HSS) columns under fire conditions. However, current methods for evaluating fire resistance of Concrete Filled Hollow Structural Steel (CFHSS) columns are highly conservative as they are based on an elemental approach without due consideration to structural interactions that occur in framed structural systems. To overcome this limitation, a system level fire resistance analysis was carried out by treating CFHSS columns as part of an overall structural frame. In this analysis, an eight story steel-framed building was modeled under a range of standard and performance-based fire scenarios (including multi-story progressive burn-out fires) to evaluate the contribution of various structural members/assemblies to overall fire resistance. One of the primary factors considered was the use of concrete filling in HSS columns as an alternative to standard W-shape columns. Results from the analysis indicate that the use of CFHSS columns, in place of W-shape columns, in a performance-based environment can fully eliminate the need for applied fire protection to columns, while providing the required level of structural fire resistance.

A Study on the Effective Method of Fire Extinguisher Maintenance In the Underground Parking Lot of the Apartment (아파트 지하주차장 소화기의 유지관리 효율화 방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.3
    • /
    • pp.1-8
    • /
    • 2016
  • The definition of an apartment is a building more than 5 stories high and which is the standard law. Currently, the number of apartments is increasing much faster than detached houses. Owning an apartment is a normal trend these days. However, the increasing number of apartments has been increasing the number of apartment fires which also has been making social problems. Therefore, this study was conducted for the fire extinguisher among other fire facilities because it is important for initial fire suppression. The research subject is on the fire extinguisher that is in the underground parking lot of 40 apartment complexes which are more than 10 stories. Survey and analysis were conducted for 80 fire extinguishers. There are two fire extinguishers for each apartment. The result of this study is that all installed fire extinguishers are ABC dry chemical type, 92% of them is 3.3kg and that meet the legal height(less than 1.5m). However, the condition such as appearance, inspection, manufactured year, appearance of signs, material of signs, size of signs, etc. was insufficiency. So improvement of law and system that are fire facility construction, maintenance implementation and additional designation of type approval about sign will be needed in my opinion.

A Study of Comparative Evaluation for High-rise Building Fire Risk by the Use of FREM (FREM을 적용한 고층건물의 화재위험도 비교평가연구)

  • 김동일;손기상;이수경
    • Fire Science and Engineering
    • /
    • v.16 no.1
    • /
    • pp.45-50
    • /
    • 2002
  • This study set its bases needed for building fire risk analysis by examining general concept and definitions of fire risk analysis, and its access methods. Upon this basis, by using a computer program FREM, we brought the type of hazards out of the fire risk assessment applied to the typical 100 high-rise buildings in and out of this country. In this process, we also sorted out the programs arising from the application of a foreign born tool to domestic conditions. the credibility of fire separations and automatic fire protection system in a building would be the two most important things in an attempt to evaluate fire risk in high-rise buildings. In addition, it is vital for the purpose of securing fire safety in high-rise buildings that the systems should be properly installed and carefully maintained. When we try hard to study the evaluation standards to the above systems and, someday in the future, to employ them in evaluating fire risks in high-rise buildings, we can measure the risks much more precisely with less expenses than that we needed today.

Study of the Fire Risk of Occupants During Pilotis Space Fires (필로티 공간의 화재 시 재실자의 위험성에 관한 연구)

  • Choi, Seung-Bok;Choi, Doo-Chan;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.144-150
    • /
    • 2016
  • An apartment house with a pilotis that raises the architectural volume and provides a space for circulation is becoming popular. With the popularity of pilotis in apartment houses, people also have a keen interest in the potential fire risk at the pilotis. As residents can only access their apartment house through the pilotis, there is a risk to the occupants if there is fire there. Therefore, this study evaluated the pilotis fire cases of urban multifamily housing to conduct a Fire Dynamics Simulator (FDS) and Fire Evacuation Simulation (FES). Through these two simulation methods, it is possible to validate the riskiness of fire at an apartment with a pilotis. The study identified that the toxic gases and flame spread out to the pilotis within hundred seconds after ignition. In addition, the toxic gases and flame also reach the second floor within three seconds and the entire building within 735 seconds if the entrance doors at the pilotis are opened. On the other hand, the FES simulation results showed that it also takes about approximately 609 seconds to excavate from the apartment house with a pilotis. Therefore, this research shows that an apartment house with a pilotis can ensure the building occupants' lives and their safety if there is fire.