• Title/Summary/Keyword: building fire safety

Search Result 642, Processing Time 0.025 seconds

The Method of Force of Fire in High-Rise Building by Guide to the Fire Safety Concepts Tree: Focusing on Manually Fire Suppression Strategy (화재안전트리 이론에 따른 초고층건축물의 소방력 공급방안: 수동화재진압 전략을 중심으로)

  • Oh, Seong-Ju;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.79-88
    • /
    • 2020
  • This study analyzes the issue of the supply of force of fire in the high-rise buildings, and proposes an efficient method to do so. The results are as follows. First, in terms of Detect fire, it is necessary to shorten force of fire supply time by diversifying fire alarms such as alarms, vibrations, and voices from outside, clarification of fire occurrence points, and marking of fire. Second, with regard to communication signals, strengthening the installation target of wireless communication auxiliary facilities, supplementing the installation of repeaters, and constructing a multicommunications network were proposed. Third, in terms of Decide action, it is necessary to supply firefighter and firefighting equipment with the method of crossing of a river in adjacent buildings. Fourth, in terms of Respond to site, helicopters and emergency elevators are used to assist in the supply of firefighting equipment using drones. Easy-to-break glass windows and identification marks are required in every floor. Finally, in terms of applying fire suppressants, water can be supplied by means of a helicopter adjacent to the structure.

Distribution of Heat and Smoke Related to Openings in Hise-Rise Apartment Building Fires (고층 공동주택의 개구특성에 따른 화재시 열.연기유동에 관한 연구)

  • 이지희
    • Fire Science and Engineering
    • /
    • v.15 no.2
    • /
    • pp.59-79
    • /
    • 2001
  • The paper proposes alternatives for fire safety in architectural planning through heat-smoke distribution related to openings so that we decrease casualty and property loss by fire and lay a great emphasis on building high-rise apartments with consideration of fire safety in Korea. An analysis program(HFA-Heat Fluid Analysis) is built to perform simultaneously numerical analysis and experimental analysis on rooms, units and buildings. In consequence, on the first, fire prevention methods are required to be set up related to openings for design rooms since the flow of heat and smoke is influenced by the type of openings in high-rise apartments. Second, the numerical analysis showed that different planning types cause to show differences in the spreading time of heat and smoke to design the units of high-rise apartments. On the third, each unit building showed different fire behavior depending on openings by numerical analysis and small scaled experiment on heat and smoke flow.

  • PDF

A Study on the Burning Characteristics of Interior Boards and Louvers (내장용 판재 및 루버의 연소발열특성 연구)

  • Nam, Dong-Gun;Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.34-39
    • /
    • 2014
  • It is necessary to enhance its availability and reliability of performance based fire design of building with various type of database such as experiments, survey and fire properties and so on. In order to utilize to the performance based fire design, the present study has been performed a series of experiments to investigate the burning characteristics of building materials for two types of interior board and three types of interior louver. The burning test has been also conducted for different thickness because it may show different characteristics of burning behavior such as flame spread rate and flame propagation time. The result shows that the effective heat release per unit mass of interior materials were almost constant with 15.3~16.9 MJ/kg regardless of its thickness while the peak heat release rate and maximum $CO_2$ concentration was varied with thickness.

Comparison of Two Different Smoke Extraction Schemes of Transversely Ventilated Tunnel Fire

  • Rie, Dong-Ho;Kim, Hyung-Taek;Yoo, Ji-Oh;Shin, Hyun-Jun;Yoon, Sung-Wook
    • International Journal of Safety
    • /
    • v.4 no.2
    • /
    • pp.30-35
    • /
    • 2005
  • In case of tunnel fire, one of the most effective facilities to save lives is the smoke control system. In this study, two different smoke extraction schemes of transversely ventilated tunnel were compared. One is the smoke extraction using the fixed exhaust ports on the false ceiling to achieve the uniform and distributed smoke extraction (uniform exhaust). The other is that using the remote controlled smoke extraction where only vents close to the fire is opened whereas the others are closed to enhance the limitation of the smoke spread (localized exhaust). A number of numerical simulations were performed to find out the optimal smoke extraction rate at each smoke extraction scheme to allow the tunnel users to escape to the safe area without endangering their lives by smoke.

Strength Characteristic and Phenomenon of Heated Concrete by High Temperature (고온가열 콘크리트의 강도 특성과 현상)

  • 태순호;이병곤
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.3
    • /
    • pp.132-138
    • /
    • 1997
  • For many years concrete has been the major building material for most construction. It is of primary importance that fire fighters or fire investigators have a full understanding of the properties of concrete so that better control of the fire scene is achieved. This, in turn, not only help to ensure a safer fire-fighting job but also a more successful fire investigation. So far as the fire scene investigation in concerned, knowledge about the thermal behaviour of concrete can help the investigators to determine the highest temperature that a particular spot of a fire scene has ever reached thereby providing data which may be of value in reconstructing the course of the fire.

  • PDF

A Case Study of the Sungnyemun Fire for Identification (숭례문 화재의 감식 사례 연구)

  • Choi, S.B.;Lee, J.J.;Lee, T.Y.;Lee, C.J.;Choi, D.M.
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2009.04a
    • /
    • pp.1-6
    • /
    • 2009
  • The fire of Sungnyemun, National Treasure of No.1, gave to the Korean people and fire investigators big pains. The aim of this study are the identification of combustion traces and fire patterns of wooden building fire, burned with an accelerator, after spraying flammable materials on the wooden floor through the field study observation. Also, in the case of the similar fire, these results will be as good references to fire investigators for accurate investigations.

  • PDF

A State-of-art of Experimental Research and Calculated Models of Dowel-type Timber Connections in Fire

  • Luo, Jing;He, Minjuan;Li, Zheng
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.4
    • /
    • pp.285-297
    • /
    • 2021
  • Fire safety is one of the most significant issues for the design of mid-rise and high-rise timber structures. A large number of experimental tests were conducted during the last three decades to investigate the fire performance of the dowel-type timber connections. Many influenced parameters (e.g. the thickness of the side timber, the load ratio, the fasteners type etc.) were considered in those experiments. Relevant calculated models were proposed by previous researchers to estimate the fire resistance of the connections. In this study, a series of experimental programs of dowel-type connections in fire are collected. Then, empirical formulas proposed by EN 1995-1-2, Fire safety in timber buildings, and previous researchers are presented and analyzed. The accuracy of those formulas is checked by comparisons between the experimental data and estimated results. The collected experimental research and empirical formulas can be used as the reference for the fire design of dowel-type timber connections in the future.

Statistics and Management Systems of Unwanted Domestic and Foreign Fire Alarms (국내·외 비화재보의 통계 및 관리체계에 관한 연구)

  • Hwang, Euy-Hong;Lee, Sung-Eun;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.30-40
    • /
    • 2020
  • In the event of a fire and a disaster, prompt and accurate alarms inside and outside the building are directly related to the minimization of damage and the success of life evacuation. However, due to unwanted fire alarms in automated fire detection systems, the number of dispatches by misunderstanding in the 119 service is increasing. This causes the insensitivity to the safety of building managers and the waste of the fire-fighting power. Therefore, in this study, the statistical databases and literature on unwanted fire alarms in Korea and abroad (USA, UK) were identified and the management systems for unwanted fire alarms were compared and analyzed to identify problems of statistics in the management systems for unwanted fire alarms.

Safety Assessment of Burned Building using Numerical Calculation of Unsteady Heat Conduction Equation (비정상 열전도 방정식의 수치 해석을 이용한 화재 건물의 안전성 평가)

  • 태순호;이병곤
    • Fire Science and Engineering
    • /
    • v.11 no.2
    • /
    • pp.19-24
    • /
    • 1997
  • numerical simulation of unsteady heat conduction equation were carried out by finite control volume method using the gas temperature derived from fire model as a boundary value. The reduction of compressive and flexural by heating were calculated from the temperature and the given reduction rate. It is shown that this method could be well applied to assess the safety of concrete column or beam of the burned building.

  • PDF

A Study on the Historical Comparative of Smoke Control for Fire Safety Law and Building Law (국내의 연기제어 관련 소방법과 건축법의 변천과정에 관한 연구)

  • Kim, Hye-Won;Jin, Seung-Hyun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.97-98
    • /
    • 2017
  • These days the buildings are getting higher, bigger, and in a deep. According to that, it was the Large-Scale casuality by smoke from Daeyeongak Hotel fire in 1971 to Uijeongbu apartment fire in 2015, and the law of smoke control has consistently changed. but the analysis for improving the law isn't working. Therefore on this study, it conducts the analysis of historical comparative about smoke control and it will present the basic data for improving the law of smoke control and in-depth analysis.

  • PDF