• Title/Summary/Keyword: building fire safety

Search Result 642, Processing Time 0.029 seconds

Public Safety & Security Unmanned Aerial Vehicle Heat resistance Environmental Test used in case of Building Fire (건축물 화재발생시 사용되는 재난치안용 무인기의 내열성 환경시험)

  • Kim, Da-Kyung;Bang, Hong-Soon;Kim, Ok-Kyue
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.119-120
    • /
    • 2020
  • Recently, a building fire has occurred due to various influences. Accordingly, we are developing an public safety & security unmanned aerial vehicle for fire prevention and initial response to fire. The public safety & security unmanned aerial vehicle is used to grasp the traffic route to enter the fire engine in the event of a fire in a dense structure and to determine the scale of the fire and the area of danger of collapse around the fire site. In this study, an environmental test of the public safety & security unmanned aerial vehicle's heat resistance was performed in an environment simulating a fire scene.

  • PDF

A Study on Evaluation Plan of Fire Safety Performance for Public Building (공동주택의 화재안전성능 평가방안에 관한 연구)

  • Ku, Jae-Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.4
    • /
    • pp.25-32
    • /
    • 2019
  • From the viewpoint of fire-fighting activities, public building have structural and management problems in fire, so evacuation disturbance and risk of expanding combustion are high. As a result of analyzing various fire fragile factors of public building, The evaluation areas were derived from safety systems, fire-fighting facility, structure safety, general safety and the evaluation factors were presented. Also, the characteristics of domestic and foreign certification systems were analyzed by comparing and analyzing the status of fire safety performance certification system for 6 domestic and overseas apartment houses. In conclusion, the 5 convergence directions of certification system and 22 evaluation items by 4 evaluation fields were derived, and based on this, we have established 3 convergence introduction plans of fire safety performance certification system of public building.

Extension of IFC information Modeling for Fire Safety based on WBS (작업분류체계 기반 소방 객체 IFC 정보 모델링 확장 방안 연구)

  • Won, Junghye;Kim, Taehoon;Choo, Seoungyeon
    • Journal of KIBIM
    • /
    • v.13 no.2
    • /
    • pp.37-46
    • /
    • 2023
  • The main objective of this study is to propose a method to enhance building safety using the Industry Foundation Classes (IFC) schema in Building Information Modeling (BIM). To achieve this goal, a fire object relationship diagram is created by using the Model View Definition (MVD) and Property Set (Pset) methodology, as well as the Work Breakdown Structure (WBS) based object relationship analysis. The proposed method illustrates how to represent objects and tasks related to fire prevention and human safety during a building fire, including variables that are relevant to these aspects. Furthermore, the proposed method offers the advantage of considering both the IFC object hierarchy and the project work hierarchy when creating new objects, thereby expanding the attribute information for fire safety and maintenance. However, upon confirmation via an IFC viewer after development, a problem with the accuracy of mapping between attributes and objects arises due to the issue of proxy representation of related object information and newly added object information in standard IFC. Therefore, in future research, a mapping method for fire safety objects will be developed to ensure accurate representation, and the scope of utilization of the fire safety object diagram will be expanded. Furthermore, efforts will be made to enhance the accuracy of object and task representation. This research is expected to contribute significantly to the technological development of building safety and fire facility design in the future.

BIM and Fire Safety Engineering - Overview of State of The Art

  • Davidson, Anne;Gales, John
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.4
    • /
    • pp.251-263
    • /
    • 2021
  • Fire safety engineering is a critical specialization to include in the design of a tall building yet is often excluded from the Building Information Model (BIM) and integrated design process. The design of fire safety systems is interdependent with building/structural geometry, HVAC, mechanical, and electrical systems. A BIM is a 3D visual representation that stores data on these kinds of systems. The compatibility between BIM and fire safety design seems obvious yet has received a dearth of attention in structural (fire) engineering literature. The authors herein have reviewed over 40 recent papers on utilizing BIM for fire safety engineering, focusing on contemporary literature to obtain a more up-to-date review of the state-of-the-art. The resulting trends, technologies, research gaps, and methodologies are presented in this paper. Adoption of BIM in fire safety engineering is slow and behind other disciplines which may be improved if research involved more industry partners. For BIM technology to reach its potential, industry manufacturers need to provide high LOD fire BIM objects, fire engineers and researchers need to collaborate on future advancements, and building owners/management need to be educated on how to use the benefits provided.

High-rise buildings in the general direction of the Fire Safety Management Study (초고층 건축물 소방안전관리의 기본방향에 관한 연구)

  • Choe, Man-Cheol;Kim, Byeong-Seok
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.04a
    • /
    • pp.79-93
    • /
    • 2011
  • Unlike a general building high-rise buildings itself has a kind of risk. In this study, the risk of a number of high-rise buildings have fire safety management of the particular risks associated with looking for ways to minimize focused. Theoretical Study of the United States since the collapse of the WTC buildings, and be the center of the authentic country was. outside of the high-rise building fire safety and related issues, and measures were based on the theory of reference. Issues include voluntary arson. disaster management, building codes and fire regulations of the discrepancies, such as fire safety aspects are explained in terms of three kinds, and for it to take steps in the direction suggested an alternative for high-rise buildings. Although differences of opinion between departments will not be easy to fire and building regulations regarding conflicts of laws among other things, require immediate resolution, and high-rise buildings to create a standard for effective crisis management manual countermeasures will also be ensured.

  • PDF

A Study on Fire Spread between Office Room and Atrium in the Atrium Building

  • Lee, Su-Kyung;Kim, Jong-Hoon;Ko, Han-Mog
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.345-352
    • /
    • 1997
  • We could analyse the fire behavior using the developed software for fire safety assessment in a large space such as atrium. But Korean building law hasn't admitted the result of fire risk assessment in atrium. In the legislation fire resistant wall or shutter must be required between atrium and office rooms, That has obstructed development of building design and fire protection technique in Korea. From this point of view, we made scenarios of fire spread between atrium and office rooms, and then computed fire spread and fire phenomena using FASTLite and Breakl. In this study, we can decide that fire compartmentalization between atrium and office rooms doesn't require in Atrium building if the material and fire protection system were reliable. Consequently, Korean Fire Protection Regulations have to consider in direction of increasing freedom of building.

  • PDF

Improvement of fire protection equipment the opening of according to narrow the distance between buildings (건물 간 이격거리 협소에 따른 개구부 방화설비의 개선방안)

  • Oh, Taek-Hum;Park, Chan-Seok
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.1
    • /
    • pp.61-68
    • /
    • 2013
  • In the case of the fire to the exterior of the building through openings, the openings of the adjacent building are exposed to the risk of combustion expanding and factors that affect the combustion in the radiant heat and direct flame. Recent five years, fire of the adjacent building indicated that incidence of the 5,134(2.27%) among total 225,934 cases occurred The damage scale of fire expanded was lower than in a single building but casualties(5.46%) and property(25.0%) damage were higher. Therefore, this study provides to analyze the operating status for fire protection equipment of fire-preventing area in the Seoul and to apply measures to improve fire protection equipment according to narrow the distance between the building openings studied.

A Study on the Fire Safety of High-rise Office Buildings in Respect of Architectural Design (고층 사무소건축의 화재안전에 관한 건축계획적 연구)

  • 이강훈
    • Fire Science and Engineering
    • /
    • v.8 no.2
    • /
    • pp.3-15
    • /
    • 1994
  • The purpose of this paper is to present refernce data to be considered in designing for the fire safety of high-rise office buildings. This paper deals with the characteristics of high-rise office buildings in the fire safety aspects, the basic principles for the fire safety of high-rise office building design, and this study is focused particularly on the location of the escape route of core plan for fire safety in high-rise office buildings.

  • PDF

A Study on the Evacuation Safety Design laws based on the Fire Risk (화재리스크에 기초한 피난안전설계법에 관한 연구)

  • Huh, Ye-rim;Kim, Hye-Won;Lee, Byeong-Heun;Jin, Seung-Hyeon;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.51-52
    • /
    • 2019
  • Currently in domestic, it is difficult to the evacuation in fire due to the building is higher. Therefore it is necessary to evacuation safety design of building. To conduct the evacuation fire design of building, it should be done the Evacuation Safety Verification. But it is not sufficient the Study about Evacuation Safety Verification in currently domestic. Therefore in this study, we conducted the evacuation safety verification using people who they can't the evacuation themselves. The method of verification, we suggest the comparative that people who they can't the evacuation themselves and available safety evacuation time. Available safety evacuation time is determined by determined method from disaster statistics of casualties or equivalence with current standard requirement. it is doing to objectively judge of evacuation safety design validity in building.

  • PDF

Safety Performance Assessment for a Aged Building (노후 건축물의 안전성능 평가항목)

  • Kwon Dong-Chan;Lee Yong-Jae;Lee Chan-Sik
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2004.11a
    • /
    • pp.296-300
    • /
    • 2004
  • As a building aged, overall performance considering structural safety, equipment safety and fire safety is lowering gradually. Since the building performance and the overall value of the building change as time elapse, exact safety performance of the building should be evaluated not only maintaining the building efficiently and also preventing disputes between buyer and seller of the building. We suggest major elements for assessing building's safety performance through surveying literatures, interviewing experts, reviewing existing assessment models, The assessment elements proposed here ate comprised of structural safety, equipment safety, fire safety, fire protection and fire escape, etc. This study helps to make a safety performance assessment criteria for a building.

  • PDF