• Title/Summary/Keyword: building control

Search Result 3,221, Processing Time 0.03 seconds

Community-acquired Legionnaires' Disease in a Newly Constructed Apartment Building

  • Ryu, Sukhyun;Yang, Kyungho;Chun, Byung Chul
    • Journal of Preventive Medicine and Public Health
    • /
    • v.50 no.4
    • /
    • pp.274-277
    • /
    • 2017
  • Objectives: Legionnaires' disease (LD) is a severe type of pneumonia caused by inhalation of aerosols contaminated with Legionella. On September 22, 2016, a single case of LD was reported from a newly built apartment building in Gyeonggi province. This article describes an epidemiologic investigation of LD and identification of the possible source of infection. Methods: To identify the source of LD, we interviewed the patient's husband using a questionnaire based on the Legionella management guidelines from the Korea Centers for Disease Control and Prevention. Water samples from the site were collected and analyzed. An epidemiological investigation of the residents and visitors in the apartment building was conducted for 14 days before the index patient's symptoms first appeared to 14 days after the implementation of environmental control measures. Results: Legionella pneumophila serogroup 1 was isolated from the heated-water samples from the patient's residence and the basement of the apartment complex. Thirty-two suspected cases were reported from the apartment building during the surveillance period, yet all were confirmed negative based on urinary antigen tests. Conclusions: The likely source of infection was the building's potable water, particularly heated water. Further study of effective monitoring systems in heated potable water should be considered.

Influence Factors and Management based on Phase of Building Construction for the Improvement of Post Occupancy Indoor Air Quality

  • Lim, Hyoung-Chul
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.6
    • /
    • pp.576-586
    • /
    • 2011
  • In recent years, pollution in residential spaces has been a significant area of concern. In particular, the indoor air quality (IAQ) of an apartment building before occupancy, which is related to the interior material, is a serious problem. Unlike previous research, which has mainly focused on pollution control after construction, this study has derived influencing factors and priority of management with a controlling schedule for IAQ. The objectives of this research are 1) control of schedule or improvement of management for IAQ, 2) distribution of responsibility to the parties concerned (factory, material company, construction company, design and engineering, occupancy). The results show the relative priority of the four major items in wall?based apartment buildings and in column?based apartment buildings. An analysis of the parties responsible for improvement based on the IAQ results shows more efforts to improve IAQ are needed in material factories and engineering/design companies.

System Identification of the Three Story Building Structure with a Controller (제어기가 설치된 3층 건물의 시스템 식별)

  • 주석준
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.203-211
    • /
    • 1999
  • Threr are several methods in protecting the building structures from dynamic loads such as an earthquake and a wind. Among them applying a control force to the building structure is one of the methods to decrease the vibration. The most important and difficult problem in the active control is to obtain the mathematical model of the building structure with a controller. the effective active controller can be designed from the exact model of the system In this paper the three story test building with an active mass driver is identified experimentally. the system matrices corresponding to the experimental building are found and verified with the experimentally-obtained transfer functions and responses efficiently.

  • PDF

A Study on Map Building of Mobile Robot Using RFID Technology and Ultrasonic Sensor (초음파센서와 RFID 시스템을 이용한 이동로봇의 맵 빌딩에 관한 연구)

  • Lee, Do-Kyoung;Im, Jae-Sung;Kim, Sang-Bong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.3
    • /
    • pp.239-244
    • /
    • 2010
  • This paper is to present map building of mobile robot using RFID (Radio Frequency Identification) technology and ultrasonic sensor. For mobile robot to perform map building, the mobile robot needs its localization and accurate driving in space. In this reason, firstly, kinematic modeling of mobile robot under non-holonomic constrains is introduced. Secondly, based on this modeling, a tracking controller is designed for tracking a given path based on backstepping method using Lyapunov function. The Lyapunov function is also introduced for proving the stability of the designed tracking controller. Thirdly, 2D map building is performed by RFID system, mobile robot system and ultrasonic sensors. The RFID mobile robot system is composed of DC motor, encoder, ultra sonic sensor, digital compass, RFID receiver and RFID antenna. Finally, the path tracking simulation results and map building experimental results are presented to show the effectiveness of the designed controller.

A Simulation Study on Effect Analysis of EMS Combined Control of Central Cooling and Heating System (중앙냉난방시스템의 EMS 복합제어 효과 분석에 관한 시뮬레이션 연구)

  • Jae-Yeob Song;Byung-Cheon Ahn
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.18 no.4
    • /
    • pp.33-44
    • /
    • 2022
  • In this study, we analyze the existing heating and cooling operation method for an office-type complex building with a central heating and cooling system, and examine the effects of applying various EMS that can be applied according to the load size to save energy in the building. For this purpose, simulation analysis was performed. As a control method, reset control of chilled water, hot water, cooling water and supply air temperatures, optimal start/stop of heat source, and number of heat source control were applied according to the load size, and energy consumption was analyzed accordingly. In addition, when all of these control methods were applied, the overlapping energy saving effect was finally confirmed. As a result, it was possible to confirm the energy saving effect when EMS for reset control and heat source control were applied compared to the existing control method of the heating and cooling system, and the effect for the case of using all these control methods in combination was also confirmed.

The Improvement Plan of Organization Management Through the Survey of Actual Condition in Construction Work (건설공사(建設工事) 실무분석(實務分析)을 통한 조직관리(組織管理) 개선방안(改善方案))

  • Choi, Byung-Ju;Cui, Xian;Choi, Suk-Woo;Kim, Ok-Kyue
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.2
    • /
    • pp.121-129
    • /
    • 2008
  • Domestic exoteric construction market by opening of world construction market with recent FTA of rapidly change. On these time, need quality increase of construction to possess government official and international competitiveness of customer satisfaction by offering consumer building of good quality. Therefore, must establish direction to inspects and must advance forward formation government official's present actual conditions for building company's QI. This study is as following if summarize studying result of formation government official to improve quality in construction spot. First, formation's CEO will for QI need side improvement the formation government official enemy by important thing. Second, at checking activity and systematic action that participate of responsible persons cooperation enterprise space-time by complete charge department organization should be achieved. Third, complete charge department for quality control operation large size construction firm substantially formation Organizational well operate, but heavy hydrogen building company was construed by greatly unprepared misgovernment. AHP analysis result complete charge department is serious necessity, and the CEO under direct control organizational structure was construed by thing which can bring excellent effect in operation management side of quality business side and formation. Therefore, heavy hydrogen building company should does to occupy competitive power high position with tissue at active quality complete charge deputy.

Numerical Study on Ventilation Method for Temperature Control of HRSG Building (HRSG건물 온도제어를 위한 환기방안에 관한 수치적 연구)

  • Kim, Chul Hwan;Lee, Jong Wook;Choi, Hoon Ki;Yoo, Geun Jong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.3
    • /
    • pp.240-249
    • /
    • 2009
  • HRSG(Heat Recovery Steam Generator) building is large enclosed structure included various heat sources. This building needs to appropriately keep internal air temperature for worker's safety and operability of control devices. In this study, ventilation analysis is performed to find proper ventilation method for temperature control. Ventilation analysis is applied to entire internal space of the building with standard $k-{\varepsilon}$ model and enhanced wall treatment because of large size of the structure. And the ventilation method is considered natural and forced convection with two louver structures which has damper or not. Louver structure affect directly air circulation in near HRSG and lower region of the building. Forced ventilation provides strong inertial force which cause upward airflow. From the analysis, it is found that design requirement for internal air temperature can be satisfied by forced ventilation method with louver structure without damper.

Aerodynamic modification of setback distance at half height of the tall building to minimize the wind effect

  • Bairagi, Amlan Kumar;Dalui, Sujit Kumar
    • Wind and Structures
    • /
    • v.35 no.3
    • /
    • pp.193-211
    • /
    • 2022
  • The present study focuses on aerodynamic parameters behaviors and control on the single and double side setback building models at the buildings mid-height. The study is conducted by computational fluid dynamics (CFD) simulation. This study estimates the face wise pressure coefficient on single side setback buildings with a setback range of 20%-50% and double side setback buildings with setbacks ranging from 10%-25%. The polynomial fitted graphs from CFD data predict the Cp on different setback model faces within permissible limit ±13% error. The efficient model obtained according to the minimum drag, lift, and moment consideration for along and across wind conditions. The study guides the building tributary area doesn't control the drag, lift, and moment on setback type buildings. The setback distance takes a crucial role in that. The 20% double side setback model is highly efficient to regulate the moment for both along and across wind conditions. It reduces 17.5% compared to the 20% single side setback and 14% moment compared to the 10% double side setback models. The double side setback building is more efficient to control 4.2% moment than the single side setback building

Power Consumption Management Algorithm Based on OpenADR (OpenADR 기반의 전력사용량 관리 알고리즘)

  • Kim, Jeong-Uk
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.12
    • /
    • pp.991-994
    • /
    • 2016
  • This paper presents a load management method based on OpenADR of smart grid. Previous demand side algorithm is restricted on reducing peak power. But, in this paper we suggest a method of performing the energy-saving control according to the power price utilizing building automatic control system installed on the customer side in the case of hourly differential pricing signal is transmitted to the open automated demand response system. And, we showed the integrated demand management software for 3 buildings.

Geometrical Building Analysis for Outdoor Environment Understanding of Autonomous Navigation Robot (자율주행 로봇의 외부환경 이해를 위한 기하학적인 빌딩 분석)

  • Kim, Dae-Nyeon;Trinh, Hoang-Hon;Jo, Kang-Hyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.3
    • /
    • pp.277-285
    • /
    • 2010
  • This paper describes an approach to analyze geometrical information of building images for understanding outdoor environment of autonomous navigation robot. Line segments and color information are used to classily a building with the other objects such as sky, trees, and roads. The line segments and their two neighboring regions are extracted from detected edges in image. The model of line segment (MLS) consists of color information of neighbor regions. This model rules out the line segments of non-building face. A building face converges into dominant vanishing points (DVPs) which include one vertical point and one of five horizontal points in maximum. The intersection of vertical and horizontal lines creates a facet of building. The geometrical characteristics such as the center coordinates, area, aspect ratio and aligned coexistence are used for extracting the windows in the building facet. In experiments, 150 building faces and 1607 windows were detected from the database of outdoor environment. We found that this result shows 94.46% detection rate. These experimental images were all taken in Ulsan metropolitan city in Korea under difference of viewpoints, daytime, camera system and weather condition.