• Title/Summary/Keyword: building code

Search Result 977, Processing Time 0.031 seconds

A Study on the Prescriptions of American Codes for Straw Bale Structures and the Legislation Direction of Korean Straw Bale Code (미국 짚단벽구조 법규 분석 및 국내의 법제화 방향 연구)

  • Kim, Jeong-Gyu
    • KIEAE Journal
    • /
    • v.9 no.2
    • /
    • pp.91-98
    • /
    • 2009
  • The purpose of this study is analyzing the prescriptions of American codes for straw bale structures and proposing the legislation direction of Korean building code. The process of this study is as follows: (1) To set up the legislation direction of straw bale code of Korea, this study investigated the current state and features of straw bale houses in Korea, and looked into the worldwide status of straw bale codes and permitting. (2) To provide basic data for the legislation of Korean straw bale code or guideline, this study analyzed American codes for straw bale structures like the Tucson/Pima County Arizona Building Code Appendix Chapter 72 - Straw-Bale Structures, California State Guidelines for Straw-Bale Structures, New Mexico Standards for Non-load Bearing Baled Straw Construction, Oregon State Residential Code Appendix M - Straw-Bale Structures and so on. The analysis items are the scope of rule application, material specifications, requirements for straw bale walls/foundations and construction requirements. (3) On the base of analysis of American straw bale codes, this study proposed the legislation process and direction of Korean straw bale code and guideline.

Realization of Smart Greenhouse Cost Using Greenhouse Structural Code and Greenhouse Construction Estimate (온실구조기준 및 온실공사 품셈을 활용한 스마트 온실 단가 현실화 연구)

  • Lee, Chul-sung;Kim, Hyuk;Shin, Seung-wook;Park, Mi-lan
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.24 no.2
    • /
    • pp.29-36
    • /
    • 2022
  • This study analyzed the effects of building and greenhouse structural code on the structural design and the greenhouse construction cost. The over-design possibility of greenhouse was analyzed when building structural code was applied using standard smart greenhouse drawings. The possibility of decrease in greenhouse construction cost was investigated if the currently applied building structural code was replaced with greenhouse structural code. As a result of comparing the member sizes with the standard drawings, building structural code was designed with 13%~74% more steel than greenhouse structural code. When building construction estimate was replaced with greenhouse construction estimate, it was possible to reduce the total construction cost of the glass greenhouse by 17% and that of the vinyl greenhouse by 14%. Since there is no standard construction estimate suitable for greenhouses, the wage unit price is set excessively, and the construction cost of the smart greenhouse is increasing. In conclusion, it is necessary to establish greenhouse structural code and greenhouse construction estimate to lower the greenhouse construction cost.

A Study on Sunshine Environment with Different Distance between Buildings (인동간격에 따른 일조환경에 대한 연구)

  • 최용석;최지혜;김용식
    • Journal of the Korean housing association
    • /
    • v.15 no.2
    • /
    • pp.55-62
    • /
    • 2004
  • Apartment design in residential Area is restricted by building distance limit code. Building distance limit decreases gradually to the 0.8H(height), and residential area has 250% site area ratio by building code, so site using has become efficient. In this study, examine the relationship between present building distance limit and right of daylighting environment by computer simulation. As well, high-rise residential officetel and multipurpose residential building becomes increase in commercial non-residential area. In the domestic, residential type multipurpose building made at the business area or central business area has 400∼800% site area ratio by building code. However, at a dweller's point of view, there are much lacks of environmental consideration to provide suitable daylighting environment. And, POE: Post Occupancy Evaluation is not completed yet. In this study, however, progress architectural environment prediction, basis by right of daylighting, and examine the possibility of daylighting by architectural distance limit code in residental area and by high-rise, high-density residential building in non-residental downtown area.

On the Chinese Code on fire safety design of steel building structures

  • Li, G.Q.;Guo, S.X.;Jiang, S.C.
    • Steel and Composite Structures
    • /
    • v.5 no.5
    • /
    • pp.395-405
    • /
    • 2005
  • This work introduces to the international scientific community the Chinese Code on fire safety design of steel building structures. The aim of the Code is to prevent the structure of a steel building subjected to fire from collapsing, ensure safe evacuation of building occupants, and reduce the cost for repairing the damages of the structure caused by fire. The main contents of the Code is presented in this paper, including the fire duration requirements of structural components, fundamental requirements on fire safety design of steel components, temperature increasing of atmosphere and components in fire, loading effect and capacity of various components in fire, and procedure for fire-resistant design of steel components. The analytical approach is employed in the Code and the effectiveness of the Code is validated through experiments.

Application of Classification of Object-property Represented in Korea Building Act Sentences for BIM-enabled Automated Code Compliance Checking (BIM기반 설계 품질검토 자동화를 위한 건축 관련 법규문장의 객체 및 속성 표현에 대한 체계화 접근방법)

  • Shin, Jaeyoung;Lee, Jin-Kook
    • Korean Journal of Computational Design and Engineering
    • /
    • v.21 no.3
    • /
    • pp.325-333
    • /
    • 2016
  • This paper aims to classify objects and their properties represented in Korea Building Act sentences for applying to BIM-enabled automated code compliance checking task. In order to conduct automated code compliance checking, it is necessary to develop translation process of converting the building act sentences into computer-executable forms. However, since Korea building act sentences are written in natural language, some of requirements are ambiguous to translate explicitly. In this regard, the building act sentences regarding building permit requirements are analyzed focusing on the regulation-specific objects and related properties representation from noun phrases within the scope of this paper. From 1977 building act sentences and attached reference regulations, 1200 regulation-specific objects and about 220 related properties are extracted and classified. In the application for the classification, object-property database is implemented and some of application using the database and the regulation-specific classification is suggested to support to generate rule set written in computable codes.

Reviewing the Expandability of KBimCode based on the Comparison between Korean and Chinese Building Act - Centered around the Egress and Fire Safety Related Regulations - (한.중 건축법규 비교분석을 통한 KBimCode의 확대 적용가능성 고찰 - 피난 및 방화와 관련된 법규항목을 중심으로 -)

  • Huang, JinHua;Park, SeoKyung;Lee, Jin-Kook
    • Design Convergence Study
    • /
    • v.15 no.6
    • /
    • pp.73-92
    • /
    • 2016
  • As one of empirical research and developments on BIM applications to improve design quality and productivity of building, efforts have been devoted to automated compliance checking of building design for building permit. KBimLogic is a mechanism that translate Korean Buidling Act to the computational language called KBimCode. KBimCode aims to standardized and neutral language that can be applied to various design rules. This paper focuses on testing expandability of KBimCode by appling it on Chinese Building Act. We analyzed Chinese national regulation on fire protection and evacuation, based on 1) Object·property, 2) function for predicate processing, 3) relationship of sentences. As a result, Chinese Building Act were successfully translated to KBimCode with some important implications for further application. Based on the finding of the paper, KBimCode is expected to be applicable to kinds of design rules.

Overview of Seismic Loads and Application of Local Code Provisions for Tall Buildings in Baku, Azerbaijan

  • Choi, Hi Sun;Sze, James;Ihtiyar, Onur;Joseph, Leonard
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.1
    • /
    • pp.65-71
    • /
    • 2014
  • Baku, the capital of Azerbaijan, has seen a boom in construction in recent years. The old Baku city has been rapidly transforming into a new hub of high-rise buildings and lively cultural centers hosting the Euro Vision Song Contest in 2012 and European Games in 2015. A major population shift to Baku from its suburbs and the countryside has resulted in the doubling of Baku's population in the 4 years between 2009 and 2013. As of January 2013, Baku's population reached four million people, 43% of the citizens in Azerbaijan according to The State Statistical Committee of Azerbaijan. With this trend, the city needs more high-rise buildings to accommodate rapidly increasing demands for more housing and business space. Until the Azerbaijan Seismic Building Code was published in 2010 and became effective, many different seismic criteria, in terms of building codes and seismic intensities, were used for all new high-rise projects in Baku. Some designers used the SNIP (Russian) code with seismic level 9 or level 8 with 1 point penalty. Others used the Turkish code with Seismic Zone 1, UBC 97 with Zone 2 through 4, or IBC with Sa = 0.75 g through 1.0 g. The seismic intensity is now clarified with the Azerbaijan Seismic Building Code. However, the Azerbaijan Seismic Building Code is appropriate for low-rise buildings applications but may be inappropriate for high-rise project applications. This is because the code-defined response spectrum yields unrealistically conservative seismic forces for high-rise buildings with long periods, as compared to those determined by other internationally accepted building codes. This paper provides observations and recommendations for code-based seismic load assessment of high-rise buildings in the Baku area.

KBC Seismic Design Force for Nonstructural Element (KBC 비구조요소 내진설계 하중)

  • Kim, Dae-Kon
    • Journal of Korean Association for Spatial Structures
    • /
    • v.14 no.1
    • /
    • pp.77-84
    • /
    • 2014
  • Simple 3, 10, and 30-story buildings with a nonstructural element which is located at roof or near the middle of the building height are selected. Based on 2009 Korean Building Code, the seismic design force applied at the nonstructural element is evaluated. Response spectrum analysis is conducted with the design response acceleration spectrum of 2009 Korean Building Code and the analytical response is compared with the seismic design force from the Code. Furthermore, an artificial earthquake based on Korean design response acceleration spectrum and the 50% intensity of El Centro earthquake, which can be considered as the maximum future earthquake possibly occurring in Korea, are selected to conduct time history analysis. When the period of the nonstructural element is shorter than 0.06 second or longer than that of the 1st period of each building, the Code equations of seismic design force for nonstructural element seems to be appropriate. However, the period of the nonstructural element is close to the one of the building's higher mode periods including the 1st period, seismic force of the nonstructural element might exceed the Code specified seismic design force.

Estimation of the Fundamental Period for Residential Buildings with Shear-Wall System

  • Chun, Young-Soo;Chang, Kug-Kwan;Lee, Li-Hyung
    • KCI Concrete Journal
    • /
    • v.12 no.1
    • /
    • pp.121-130
    • /
    • 2000
  • This study focused on evaluating the reliability of code formulas such as those of the current Korean Building Code(KBC 1988). UBC 1997, NBCC 1995. and BSLJ 1994 for estimating the fundamental period of RC apartment buildings with shear-wall dominant systems, representative of typical residential buildings in Korea. For this purpose, full-scale measurements were carried out on fifty RC apartment buildings, and these results were compared to those obtained by code formulas and also by dynamic analysis. Although these code formulas are based on the measured periods of buildings during various earthquakes and building period varies with the amplitude of structural deflection or strain level, ambient surveys should provide an effective tool for experimentally verifying the design period to the completed building. This comparison shows that comparatively large errors are likely to occure when the code formula of KBC 1988 is used, and all the other code formulas are not sufficient to estimate the fundamental period of apartment buildings with shear-wall dominant systems. An improved formula is proposed by regression analysis on the basis of the measured period data. The proposal is for the servicebility stress level, but it can also be applied for seismic code in the regions of low seismicity similar to Korea.

  • PDF

A study on the Building Use code and Use change (건축물 용도분류와 용도변경 기준에 관한 연구)

  • Shim, Jae-Heon;Lee, Won-Geun;Lee, Jae-Kook
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.3 no.2
    • /
    • pp.39-46
    • /
    • 2003
  • Now we using purpose area rule of city planning code in city planning areas for efficient, economical use of land and increasement of common welfare. Architectural code restrict building purpose after each division of area and this aimed for making more comfortable and convenient living atmosphere in city environment. Through this research we extracted conclusion about purpose area distinction system and restriction of building purpose after examined changes and tendencies of these rules. And the conclusion is the changes of purpose area distinction system issued from 32 kinds of distinctions in 1978, 28, 30, 32 kinds of distinctions in 1992 to 21kinds of distinctions in 1999 are caused by demand of enabling different purposes of programs can exist within one building possible.

  • PDF