• Title/Summary/Keyword: bubbling

Search Result 220, Processing Time 0.022 seconds

Visualization and Analysis of Bubbling Phenomenon in the Injector of LPDi Engine (LPDi기관의 인젝터내 기포발생현상의 가시화 및 해석)

  • Noh, Ki-Chol;Lee, Jong-Tai
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.454-459
    • /
    • 2003
  • The one of the most important subject to develop a LPDi engine is to suppress the generation of bubble inside LPG direct injector. For the purpose of this, in this study, the analogy visualization injector to visualize the generation and behavior of bubble, is manufactured and the bubbling phenomenon and behaviors are visualized and studied. The bubble inside the injector is generated at injection hole and after rising by buoyancy, it disappear around the top of a nozzle. The number of bubble generated is little changed regardless of the lapse of time but it is increased remarkably as the temperature around the injector is increased. With injection, the temperature around the injector at which the bubble is generated in_cylinder is much lower than that without injection because the transient pressure drop of fuel by injection.

  • PDF

Biomass Combustion Performance and Ash Characteristics (바이오매스의 연소 성능과 회재 특성)

  • Moon, Jihong;Kim, Kwangsoo;Jeong, Jaeyong;Park, Minsun;Park, Uenhyae;Yoon, Jeongjun;Hwang, Jungho;Lee, Uendo
    • 한국연소학회:학술대회논문집
    • /
    • 2012.04a
    • /
    • pp.227-229
    • /
    • 2012
  • Diversification of combustion fuel is the demands of the times and biomass is the most attractive option since it can contribute to the prevention of global warming at the same time. Due to the national renewable obligation, generally called Renewable Portfolio Standard (RPS), many power companies are considering direct combustion of biomass or co-firing with coal. In order to use biomass as a fuel, informations of its combustion characteristics and ash related problems should be investigated. In this study, combustion performance of biomass was assessed in a bubbling fluidized bed combustor, and ash characteristics of various biomass fuels were studied with standard test method.

  • PDF

Mass Transfer of Sulfur Dioxide in Flue Gas Desulfurization Process Utilizing a Jet Bubbling Scrubber (기포분사반응기를 사용한 배연탈황공정의 아황산가스 물질전달)

  • 동종인;나진균;홍지형
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.8 no.4
    • /
    • pp.262-268
    • /
    • 1992
  • The trend of international concerns on environmental conservation and domestic demand of ambient air quality improvement, specially on sulfur dioxide level has resulted in the establishment of mid-term strategy of environmental improvement and stepwise strengthening of emission regulations in this decade in Korea. Development of flue gas desulfurization(FGD) process is becoming an essential task to be accomplished especially for the power plants and large industrial facilities. This study is an initial stage researc focusing on the mass transfer principles in wet type FGD process and the effects of operating variables of a jet bubbling scrubber utilizing limestone slurry on sulfur dioxide removal efficiency. Experimental results showed this type of scrubbing system has some advantages in terms of mass transfer mechanism and removal efficiency. More rigorous research is needed for the reaction system and the comparison with existing FGD processess for the possible development of a process which is compatative in view of installation cost and treatment of by-products.

  • PDF

Process Design and Selection of Operating Conditions for SMART System (SMART 시스템의 공정설계 및 조업조건 선정)

  • Ryu, Ho-Jung
    • Journal of Hydrogen and New Energy
    • /
    • v.18 no.1
    • /
    • pp.1-11
    • /
    • 2007
  • To check feasibility of SMART(Steam Methane Advanced Reforming Technology) system, conceptual design and sensitivity analysis of operating variables have been performed based on the design program of two-interconnected fluidized beds. Among three configurations of two-interconnected fluidized beds systems, the bubbling-bubbling system was selected as the best configuration. Process design results indicate that the SMART system is compact and feasible. Based on the selected operating conditions, the effects of variables such as process capacity, pressure, and weight percent of $CO_2$ absorbable component have been investigated as well.

A Study on the Age Degradation Kinetics of Pole Transformer Oil (주상변압기 절연유의 경년열화반응 속도론에 관한 연구)

  • 남영우
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.1
    • /
    • pp.99-105
    • /
    • 1997
  • In the paper, aging of insulating oil in pole transformer has been studied by performing accelerated thermal aging test. Dissolved gases were extracted by air bubbling method. Concentration of dissolved gases were modified by extraction ratio of each gases in insulating oil. Aging of insulating materials were proceeded by thermal degradation and oxidation reaction. Both of the reactions followed zeroch order kinetics. Formation rate equations for hydrocarbons, carbon oxides, and hydrogen were derived. It was conformed by gas analysis and UV-Visible spectrophotometric method that iron core and copper coil in pole transformer act as catalyst during the aging process.

  • PDF

전기집진기술의 현황과 장래전망(I)

  • 고명삼;이달우
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.1
    • /
    • pp.24-33
    • /
    • 1997
  • In this paper, aging of insulating oil in pole transformer has been studied by performing accelerated thermal aging test. Dissolved gases were extracted by air bubbling method. Concentration of dissolved gases were modified by extraction ratio of each gases in insulting oil. Aging of insulting materials were proceeded by thermal degradation and oxidation reaction. Both of the reactions followed zeroth order kinetics. Formation rate equations for hydrocarbons, carbon oxides, and hydrogen were derived. It was conformed by gas analysis and UV-visible spectrophotometric method that iron core and copper coil in pole transformer act as catalyst during the aging process.

  • PDF

Flow Visualization and PIV Measurement of Multiphase Flow in Highty Viscous Liquid (고점성 유체 내부에서의 다상유동장 가시화 및 PIV 측정)

  • Kim, Hyun-Dong;Ryu, Seung-Gyu;Kim, Kyung-Chun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2006.12a
    • /
    • pp.48-54
    • /
    • 2006
  • A visualization study of flow characteristics in a mixer using multi-nozzle bubbling was performed. The mixer is filled with liquid glycerin (dynamic viscosity = $1000mPa{\cdot}$ s at $25^{\circ}C$) and convective mixing is induced by air bubbles generated from 9 orifices installed on the bottom of the mixer. To visualize the flow field, PIV (Particle Image Velocimetry) system consisting of 532nm Nd:YAG laser, $2k\times2k$ CCD camera and synchronizer is adopted. The bubbles generated with uniform size and frequency form bubble stream, and bubble streams rise vertically without interaction between bubble streams. Mixing efficiency is affected by the height of bubbler and the effective height of bubbler is 20mm from the bottom of the mixer.

  • PDF

Preparation of Ferroelectric $\textrm{SrBi}_{2}\textrm{Ta}_{2}\textrm{O}_{9}$ Thin Films Deposited by Plasma-enhanced Metalorganic Chemical Vapor Deposition (플라즈마를 이용한 유기금속 화학증착법에 의한 강 유전체 $\textrm{SrBi}_{2}\textrm{Ta}_{2}\textrm{O}_{9}$ 박막의 제조)

  • Seong, Nak-Jin;Kim, Nam-Gyeong;Yun, Sun-Gil
    • Korean Journal of Materials Research
    • /
    • v.7 no.2
    • /
    • pp.107-113
    • /
    • 1997
  • $SrBi_{2}Ta_{2}O_{9}(SBT)$ thin films wcre prepared on $Pt/Ti/SiO_{2}/Si$ suhsrrate by pL~snia-enhanced chemical vapor deposition. Sr and Ta huhhling temperatures were kept ,it $120^{\circ}C$ Iron1 X- ray tiiffriict!on. n~icrostruc~ure. and composjrional analysis of SH7' films, respectivels Hi I~ut~t~lmg tempcl.arure was varied SR'I' thin tilrns dcpositcd ar i3i buhbling temperature of $130^{\circ}C$ have dielccrric constanr of 150 anti dissipation factor of 0 02 at IOOkFic. I .eakagc wrrent density of films was ahour $1.0{\times}10^{-8}A/cm^2$ at 20kV/cm. 1.eakage current i11amcrc1istic.s of Sli'l' films nras c.ontrolled by I'oole Frcnkel emission Kenianent polariziit~on and mercivc field oi SR\ulcorner' films annealed at $550^{\circ}C$ were $9{\mu}C/cm^2$ and 70kV/cm, respectively.

  • PDF

Measurement of Carbon Nanotube Agglomerates Size and Shape in Dilute Phase of a Fluidized Bed (유동층 반응기 희박상 내 탄소나노튜브 응집체의 크기 및 형상 측정)

  • Kim, Sung Won
    • Korean Chemical Engineering Research
    • /
    • v.55 no.5
    • /
    • pp.646-651
    • /
    • 2017
  • Size and shape of carbon nanotube (CNT) agglomerates in the dilute phase of a bubbling fluidized bed ($0.15m\;i.d{\times}2.6m\;high$) have been determined by the laser sheet technique. Axial solid holdup distribution of the CNT particles showed S curve with dense phase and dilute phase in bubbling fluidization regime. Heywood diameter and Feret diameter of the CNT agglomerates in the dilute phase of bubbling fluidized bed increased with increasing gas velocity. The CNT particle number in the agglomerates increased with increasing of gas velocity. Aspect ratio increased and circularity, roundness and solidity decreased with increasing of gas velocity. A possible mechanism of agglomerates formation was proposed based on the obtained information.