• Title/Summary/Keyword: bubbles

Search Result 884, Processing Time 0.038 seconds

Reynolds and froude number effect on the flow past an interface-piercing circular cylinder

  • Koo, Bonguk;Yang, Jianming;Yeon, Seong Mo;Stern, Frederick
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.3
    • /
    • pp.529-561
    • /
    • 2014
  • The two-phase turbulent flow past an interface-piercing circular cylinder is studied using a high-fidelity orthogonal curvilinear grid solver with a Lagrangian dynamic subgrid-scale model for large-eddy simulation and a coupled level set and volume of fluid method for air-water interface tracking. The simulations cover the sub-critical and critical and post critical regimes of the Reynolds and sub and super-critical Froude numbers in order to investigate the effect of both dimensionless parameters on the flow. Significant changes in flow features near the air-water interface were observed as the Reynolds number was increased from the sub-critical to the critical regime. The interface makes the separation point near the interface much delayed for all Reynolds numbers. The separation region at intermediate depths is remarkably reduced for the critical Reynolds number regime. The deep flow resembles the single-phase turbulent flow past a circular cylinder, but includes the effect of the free-surface and the limited span length for sub-critical Reynolds numbers. At different Froude numbers, the air-water interface exhibits significantly changed structures, including breaking bow waves with splashes and bubbles at high Froude numbers. Instantaneous and mean flow features such as interface structures, vortex shedding, Reynolds stresses, and vorticity transport are also analyzed. The results are compared with reference experimental data available in the literature. The deep flow is also compared with the single-phase turbulent flow past a circular cylinder in the similar ranges of Reynolds numbers. Discussion is provided concerning the limitations of the current simulations and available experimental data along with future research.

The comparison research of the setting expansion and surface condition by using method of dental stone (치과용 경석고의 사용방법에 따른 경화팽창과 표면상태 비교연구)

  • Park, Soo-chul;Nam, Sang-young;Jung, In-ho
    • Journal of Technologic Dentistry
    • /
    • v.38 no.4
    • /
    • pp.263-272
    • /
    • 2016
  • Purpose: The purpose of this study is to measure and compare a degree of setting expansion of dental stone by time depending on the mixing methods and mixing ratios of dental stone, to compare the surface state of each specimen with the use of an optical camera with microscope, and thereby to provide a fundamental material for making dental prostheses. Methods: The test on setting expansion of dental stone is based on ISO 6873. With two different mixing ratios and three kinds of stone mixing methods, test groups were created, and a total of six types of specimens (N=30) were made. Based on the specimens, the setting expansion rate of each one was measured in each time slot of 24 hours, and the surface of the set stone was measured. Results: According to the analysis on setting expansion rate of stone, the setting expansion of the specimen that was created in the way of vacuum mixing at normal mixing ratio was 0.1944% at 120 minutes; the setting expansion of the specimen that was created in the way of vacuum mixing at the mixing ratio which was 40% higher than normal mixing ratio was 0.195% at 120 minutes; the setting expansion of the specimen that was created in the way of mixing with hands at normal mixing ratio and then removing bubbles in vacuum mixer was 0.196% at 120 minutes. Conclusion: The setting expansion rate of each dental stone specimen was significantly different with the lapse of time up to 24 hours(p<.001).

Effect of Alumina Content on the Hot Corrosion of SiC by NaCl and Na2SO4 (NaCl과 Na₂SO₄에 의한 SiC 고온 부식에 미치는 Alumina 첨가량의 영향)

  • 이수영
    • Journal of the Korean Ceramic Society
    • /
    • v.28 no.8
    • /
    • pp.625-625
    • /
    • 1991
  • The specimens for the corrosion test were made by hot-pressing of SiC power with 2 wt% Nl2O3 and 10wt% Al2O3 additions at 2000℃ and 2050℃. The specimens were corroded in 37 mole% NaCl and 63 mole% Na2SO4 salt mixture at 1000℃ up to 60 min. SiO2 layer was formed on SiC and then this oxide layer was dissolved by Na2O ion in the salt mixture. The rate of corrosion of the specimen containing 10 wt% Al2O3 was slower than that of the specimen containing 2 wt% Al2O3. This is due to the presence of continuous grain boundary phase in the specimen containing 10 wt% Al2O3. The oxidation of SiC produced gas bubbles at the SiC-SiO2 interface. The rate of corrosion follows a linear rate law up to 50 min. and then was accelerated. This acceleration is due to the disruption oxide layer by the gas evolution at SiC-SiO2 interface. Pitting corrosion has found at open pores and grain boundaries.

Microstructural Characterization of MOCVD RuOx Thin Films and Effects of Annealing Gas Ambient (MOCVD RuOx 박막의 미세구조 특성평가와 열처리 가스환경 영향)

  • Kim, Gyeong-Won;Kim, Nam-Su;Choe, Il-Sang;Kim, Ho-Jeong;Park, Ju-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.9
    • /
    • pp.423-429
    • /
    • 2002
  • RuOx thin films were fabricated by the method of liquid delivery MOCVD using Ru(C$_{8}$ $H_{13}$ $O_2$)$_3$ as the precursor and their thermal effects and conductivity were investigated. Ru films deposited at 25$0^{\circ}C$ were annealed at $650^{\circ}C$ for 1min with Ar, $N_2$ or N $H_3$ ambient. The changes of the micro-structure, the surface morphology and the electrical resistivity of the Ru films after annealing were studied. Ar gas was more effective than $N_2$ and N $H_3$ gases as an ambient gas for the post annealing of the Ru films, because of smaller resistivity and denser grains. The X-ray diffraction and X-ray photoelectron spectroscopy results indicate that the Ru $O_2$ phase and the silicidation are not observed regardless of the ambient gases. The minimum resistivity of the Ru film is found to have the value of 26.35 $\mu$Ω-cm in Ar ambient. Voids were formed at Ru/TiN interface of the Ru layer after annea1ing in $N_2$ ambient. The $N_2$ gas generated due to the oxidation of the TiN layer accumulated at the Ru/TiN interface, forming bubbles; consequently, the stacked film may peel off the Ru/TiN interface.e.

The Effects of Driving Waveform of Piezoelectric Industrial Inkjet Head for Fime Patterns (산업용 압전 잉크젯 헤드의 구동신호에 따른 특성)

  • Kim, Young-Jae;Yoo, Young-Seuck;Sim, Won-Chul;Park, Chang-Sung;Joung, Jae-Woo;Oh, Yong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1621-1622
    • /
    • 2006
  • This paper presents the effect of driving waveform for piezoelectric bend mode inkjet printhead with optimized mechanical design. Experimental and theoretical studies on the applied driving waveform versus jetting characteristic s were performed. The inkjet head has been designed to maximize the droplet velocity, minimize voltage response of the actuator and optimize the firing frequency to eject ink droplet. The head design was carried out by using mechanical simulation. The printhead has been fabricated with Si(100) and SOI wafers by MEMS process and silicon direct bonding method. To investigate how performance of the piezoelectric ceramic actuator influences on droplet diameter and droplet velocity, the method of stroboscopy was used. Also we observed the movement characteristics of PZT actuator with LDV(Laser Doppler Vibrometer) system, oscilloscope and dynamic signal analyzer. Missing nozzles caused by bubbles in chamber were monitored by their resonance frequency. Using the water based ink of viscosity of 4.8 cps and surface tension of 0.025N/m, it is possible to eject stable droplets up to 20kHz, 4.4m/s and above 8pL at the different applied driving waveforms.

  • PDF

A Study on the Mechanical Properties of SM490A by FCAW Welding Attitude (SM490A의 FCAW 용접 자세별 형상에 관한 기계적 특성 연구)

  • Lim, Kwang Mook;Lee, Sung Ill
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.6
    • /
    • pp.7-12
    • /
    • 2019
  • Flux Cored Arc Welding (FCAW), which has been widely used in many industries, was developed in the 1950s to supplement shortcomings of the Shielded Metal Arc Welding (SMAW). FCAW has an advantage in that it can weld regardless of postures and give good quality results in the filed with many different working conditions. In this study, SM490A (rolled steel for welding structural purpose) with different thicknesses (L:25T+R:30T) were welded using FCAW. Then the mechanical properties (tension test, bending test, hardness test, impact test and macro test) were analyzed and the following conclusions were drawn. In the tensile test, it exceeds the KS standard tensile strength range (400~510) in all welding positions, which means there is a problem in the tensile force transmission performance. In the bending test, it was found that most of the specimens did not exhibit surface rupture or other defects during bending test and they exhibit sufficient toughness even after plastic deformation. In the hardness test, all the results were lower than the standard value of 350 Hv of KS B 0893, which means they have good hardness. In the impact test, all results were larger than the KS reference value of 27J. In the macro test, they showed uniform structure state by the shape of the weld, and there was risk of lamination because no internal defects, bubbles, or impurities were found on the surface of the weld.

Visualization of Flow Characteristics on Thermosyphon with Immiscible Binary Working Fluid (비 혼합 2유체 열사이폰의 유동 특성에 관한 가시적 연구)

  • Do, Sun Yub;Kang, Hawn Kook;Park, Seung Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3022-3029
    • /
    • 2015
  • This study presents experiments to visualize the internal flow and heat transfer characteristics of thermosyphon with immiscible of water-FC40 adopted as binary working fluid. Three different regimes depending on the amount of heat flux applied to the thermosyphon were observed: natural convection, pulse boiling, and continuous boiling. Boiling incipience took place in water, which has lower vapor pressure than FC40. During natural convection water was vaporized in liquid pool while liquid film flows were formed. On the other hand, meanwhile bubbles were generated in the liquid pool during pulse and continuous boiling, the binary working fluid of water-FC40 was observed as the mixture throughout a whole range of the thermosyphon.

Comparison of Viable Rates of Chick Embryos by Different Eggshell Window Positioning (닭 배자 조작을 위한 난각 주입부위별 생존율 비교)

  • J. Y. Han;D. S. Seo;Y. H. Hong;D. K. Jeong;Y. S. Shin
    • Korean Journal of Poultry Science
    • /
    • v.23 no.1
    • /
    • pp.9-17
    • /
    • 1996
  • This study was conducted to compare the survival rate of chick embryos among different eggshell window positions and to search for the most appropriate injection position. The eggshells were punctured at blunt-end, sharp-end and side-up with a sterilized fine forceps, respectively. The survival rate of sharp-end window was higher than the other window positions. Injection of Dulbecco’s modified eagle’s medium (DMEM) through blunt-end window (BE1) was impossible because inner cell membrane was obscure. The 2 ${\mu}$L DMEM was injected into 2.5 d-old embryo blood vessel through sharp end window. To prevent hemorrhages at the point of injection, the air bubbles were injected into the embryo blood vessel. The survival rate of chicks embryo in sharp end window was about 17.0%. Therefore, this sharp-end window system will be helpful for the production of germline chimera or transgenic chicken using primordial germ cells ( PGCs ).

  • PDF

Development of High Performance Bubble Jet Loop Heat Pipe for Hot Water Floor Heating System (온수 가열 바닥 난방 시스템용 고성능 버블젯 루프 히트파이프 개발)

  • Kim, Jong-Soo;Kwon, Yong-Ha;Kim, Jeong-Woong
    • Journal of Power System Engineering
    • /
    • v.18 no.4
    • /
    • pp.23-28
    • /
    • 2014
  • In order to increase the performance of conventional hot water floor heating system, the bubble jet loop heat pipe for the system was developed. This experiment was conducted under next conditions : Working fluid was R-134a, charging ratio was 50%. A temperature of hot water, room temperature and flow rate were $60^{\circ}C$, $15^{\circ}C$ and 0.5~1.5 kg/min, respectively. The experimental results, show that bubble jet loop heat pipe had a high effective thermal conductivity of $4714kW/m^{\circ}C$ and a sufficient heat flux of $73W/m^2$ to heat the floor to $35^{\circ}C$ in case of the 1.5 kg/min of flow rate. So the bubble jet loop heat pipe has a possibility for appling of the floor heating system. Additionally, the visualization of bubble jet loop heat pipe was performed to understand the operating principle. Bubbles made by the narrow gap between inner tube and outer tube of evaporating part generate pulsation at liquid surface of working fluid. The pulsation had slug flow and wavy flow. So working fluid circulates in the bubble jet loop heat pipe as two phase flow pattern. And large amount of heat is transferred by the latent heat from evaporating part to condensing part.

Ultrasonographic Findings of Pneumatosis Intestinalis in a Dog (개에서 장 기종의 초음파적 특징 1례)

  • Song, Yu-Mi;Lee, Jeong-Yang;Lee, Jung-Woo;Jeung, Woo-Chang;Lee, Young-Won;Choi, Ho-Jung
    • Journal of Veterinary Clinics
    • /
    • v.30 no.2
    • /
    • pp.138-141
    • /
    • 2013
  • A 4-month-old, intact male mongrel dog was presented with trauma (hit by car), astasia, stupor and abdominal pain. Radiographic findings were peritoneal effusion, intestinal dilation, right iliac fracture, and microcardia. Abdominal ultrasonography revealed severely, dilated small intestine containing anechoic fluid in lumen and intramural gas within the wall. The sonographic finding suggested pnematosis intestinalis (PI), and vascular compromise of bowel loop by trauma was strongly suspected. After the dog was dead, postmortem examination revealed discolored and necrotized small intestine strangulated by sublumbar muscle. The detection of echogenic gas bubbles in the wall of bowel using ultrasound may be helpful in detecting PI.