• Title/Summary/Keyword: bronchial tube

Search Result 25, Processing Time 0.025 seconds

Left Bronchial Rupture Following Endobronchial Intubation - One case report - (기관 삽관후 발생한 좌측 주기관지 파열 - 1례 보고 -)

  • 김건일;지현근;김형수;이희성;이원용
    • Journal of Chest Surgery
    • /
    • v.31 no.10
    • /
    • pp.1014-1016
    • /
    • 1998
  • Rupture of the bronchus following endotracheal intubation with a double-lumen tube is extremely rare in all complications of endotracheal intubation. We experienced a case of left main bronchial rupture following endotracheal intubation. This 58-year old female patient was diagnosed of well-differentiated adenocarcinoma of right lower lobe, stage IIB, preoperatively. She was intubated with Robertshaw double-lumen tube(35 Fr.) for Rt. lower lobectomy. Intraoperatively, Lt. main bronchial rupture was suspected because of pneumomediastinum and ventilation insufficiency and immediately repaired with monofilament absorbable sutures(PDS) through left thoracotomy. Postoperative course was uneventful.

  • PDF

Complete Transsection of Right Main Bronchus by Blunt Trauma -A Case Report- (둔상에 의한 우측 주기관지 완전 절단 치험 1례)

  • 조원민
    • Journal of Chest Surgery
    • /
    • v.28 no.10
    • /
    • pp.924-927
    • /
    • 1995
  • Main bronchial injury after blunt trauma is very rare in all bronchial injuries and the pathogenesis is variable and not well known in everycases. We report a case of complete transsection of right main bronchus by blunt trauma. This 24-year old patient was transferred from a local hospital with a chest tube. Because of the severe subcutaneous emphysema and tension pneumothorax, we inserted one more chest tube resulting no obvious interval change. With the impression of bronchial injury, we performed an exploratory thoracotomy. We couldn't proceed bronchoscopy in the operation room because of his unstable vital sign. After opening of the chest wall, we could identify completely transsected right main bronchus. We anastomosed the bronchus with 4~0 Vicryl interruptedly. After operation, the patient was recovered without any complication.

  • PDF

Interventional radiology of Bronchial artery embolization due to massive hemoptysis (대량객혈로 인한 기관지 동맥 색전의 중재적 방사선시술)

  • Min, Byoung-Yun;Lee, Sang-Bock
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.4
    • /
    • pp.17-24
    • /
    • 2010
  • Hemoptysis which is comparatively common symptom in respiratory disease patients is a clinical symptom which has high risk of death in spite of many curative means. Bronchial tube embolization is a very useful medical procedure when hemoptysis does not stop for treatment of internal medicine or surgery and in addition to the purpose of instant hemostasis, for patients for whom surgical operation is impossible or for the purpose of gaining time to improve the state of the patient before surgical operation. In relation to this, this study is to know of the usefulness of bronchial tube artery embolization. The objects were 60 persons for whom bronchial tube artery embolizations are conducted because of large hemoptysis occurred from March 2007 to December 2009 in J hospital. They had large hemoptysis of 400ml or more per day and 200ml or more at a time or though the quantity of hemoptysis was less than 400ml they did not respond to the treatment of internal medicine for 10 days or longer. The average age was 60.5 years and cause diseases were tuberculosis, bronchiectasis, and pneumonia and lung cancer. Embolus parts were Rt bronchial artery 19 examples, Lt bronchial artery, both bronchial artery, Rt Intercostobronchial artery, and they were the case where embolization for many blood vessels were simultaneously carried out. As embolus materials, PVA (conteour) and microcoil were used. In 76.6% of 60 persons of patients hemorrhage stopped with the lapse of time after the procedure and in 4 examples (6.6) re-embolization was carried out due to re-bleeding after the procedure. Bronchial tube artery embolization has high early success rate and effectively controls hemoptysis in the treatment of hemoptysis and is an effective emergency remedy for hemorrhage due to large hemoptysis and will be a good medical procedure which reduces death rate. In addition, primarily if it is conducted together with the treatment of internal medicine it will be, as an effective curative means for hemorrhage due to large hemoptysis, a good mediate radial rays medical procedure which reduces death rate.

Fractured Tracheostomy Tube as Bronchial Foreign Body in Child (부서진 기관튜브로 발생한 소아 기관지 이물)

  • Han, Min-Seck;Kwon, Seong-Keun
    • Korean Journal of Bronchoesophagology
    • /
    • v.16 no.1
    • /
    • pp.47-50
    • /
    • 2010
  • Fracture of tracheostomy tube with subsequent migration into the tracheobronchial tree is rare, but tracheobronchial foreign body in child carries the potentially fatal risk of respiratory obstruction, We report a case of a 5-year-old girl who had aspirated a fractured tracheostomy tube which was removed under rigid bronchoscope.

  • PDF

PIV measurement of oscillatory flow in a micro-channel as a bronchiole model

  • LEE Won-je;KAWAHASHI Massaki;HIRAHARA Hiroyuki
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.125-134
    • /
    • 2004
  • The improvement of artificial respiration method has brought about the decrease in mortality of pulmonary diseases patients. Various respiratory curative methods, inclusive of HFOV (High Frequency Oscillatory Ventilation), have been developed for more effectual and less harmful management of acute respiratory failure. However, the mechanism of gas transfer and diffusion in a bronchiole has not yet been clarified in detail. As a first approach to the problem, we measured oscillatory flows in a Y-shaped micro-channels as bronchiole model by micro Particle Image Velocimetry(micro PIV). In order to establish the fundamental technique of PIV measurements on oscillatory air flow in a micro-channel, we used about 500-nm-diameter incense smoke particles, a diode laser, a high speed camera including an objective lens, and a HFOV, which is effective technique for medical care of pulmonary disease patients, especially, infants. The bronchiole model size is that parent tube is $500\{mu}m$ width and $500\{mu}m$ depth, and daughter tubes are $450\{mu}m$ width and $500\{mu}m$ depth. From this study made on the phenomenon of fluid in micro size bronchus branch of a lung, we succeeded to get time series velocity distribution in a micro scale bronchial mode. The experimental results of velocity distribution changing with time obtained by micro PIV can give fundamental knowledge on oscillatory airflow in micro-channel.

  • PDF

Clinical Analysis of Pulmonary Resection Using Staplers (자동 조직 봉합기를 사용한 폐절제술의 임상적 고찰)

  • 맹대현;곽영태
    • Journal of Chest Surgery
    • /
    • v.29 no.8
    • /
    • pp.905-909
    • /
    • 1996
  • From 1991 to 1994, We performed 75 cases of pulmonary resection. These were divided into two groups according to the method of bronchial stump closure : 51 cases automatic staplers were a plied in 49 patients (Group 1), 24 patients were closed with manual interrupted suture (Group II). Disease entities of the patients were malignant tumor in 33 patients(Group I: Group II, 22· II, bronchiectasis in 23(18:5), benign tumor in 5(3:2), aspergilloma in 5(2:3), tuberculosis(2:1) in 3, bronchogenic cyst in 2 (0 : 2) and so on. Surgical Procedure% for these Patients were 21 Pneumonectomies(18:3), 13 bilobectomies(11:2), 26 lobectomles (14:12), 11 segmentectomies (6:5) and 4 lobectomy with segmentectomies (4:0). In conclusion, the Amount of tube drainage was smaller and the removal of chest tube after surgery was shorter than manual bronchial closure group by means of statistical significance (p=0.047, p=0.005). Although there were no statistical significance, the duration of air leakage was reduced and incidence of bronchopleural rstula was reduced in the stapler used group compared with manual bronchial closure.

  • PDF

Re-expansion Pulmonary Edema -2 Cases Report- (재팽창 폐부종 치험 2례 보고)

  • 강경민
    • Journal of Chest Surgery
    • /
    • v.28 no.1
    • /
    • pp.81-84
    • /
    • 1995
  • Re-expansion pulmonary edema following pneumothorax or hemothorax is clinically uncommon but occasionally life threatening. Clinical details are given of two patients.Ipsilateral pulmonary edema were developed after chest tube insertion due to spontaneous pneumothorax in case I and after evacuation of postoperative hemothorax in case II. The patients were treated with frequent bronchial toilet.The administration of colloid solution and diuretics was effective. The possible mechanisms underlying the edema are discussed.Both increased time of collapse and suction tended to correlate with reexpansion edema.The present two cases provided evidence for longstanding lung collapse and immediate application of suction.

  • PDF

Treatment of Massive Hemoptysis Occurred from Destroyed Lung: Prevention of Contralateral Aspiration Using Endobronchial Blocker Followed by Pneumonectomy (파괴폐에서 발생한 대량객혈의 치료: Endobronchial Blocker를 이용하여 반대측 폐로의 흡인을 방지한 후 시행한 전폐절제술)

  • Kim, Seul-Ki;Lee, Eun-Jung;Park, Ji-Young;Kim, Eun-Young;Kang, Kyung-Hwan;Chung, Hoe-Hoon;Choi, Cheon-Woong;Kim, Yee-Hyung;Yoo, Jee-Hong;Kwak, Young-Tae;Cho, Sang-Ho;Chung, Jun-Young;Kim, Dae-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.72 no.1
    • /
    • pp.68-71
    • /
    • 2012
  • Untreated massive hemoptysis, especially in patients with tuberculous-destroyed lung, is a serious complication resulting in considerable morbidity and mortality. We report a case of a patient who had active tuberculosis and a destroyed left lung with massive bleeding. He was transferred to our clinic with intubation of a right-sided Robertshaw double lumen tube and right upper lobe collapse likely due to tube malposition that was presented on chest X-ray. Because hemoptysis had persisted after bronchial arterial embolizaton, we replaced the double lumen tube with a conventional endotracheal tube and inserted an endobronchial blocker into the left main bronchus through an endotracheal tube guided by bronchoscopy to prevent aspiration of blood into the right lung. Left pneumonectomy was performed and hemotpysis was ceased. We suggest that the use of an endobronchial blocker followed by surgery may be a safe and effective modality of treatment in patients with persistent bleeding after bronchial arterial embolization.

A Case of Decannulation Difficulty (Decannulation Difficulty의 치험례)

  • 안회영;차창일;박경유
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1983.05a
    • /
    • pp.14.1-14
    • /
    • 1983
  • The most common cause of the decannulation difficulty is the trauma. This may be accidental, iatrogenic such as prolonged intubation, high tracheostomy, secondary infection, formation of granulation tissue, improper use of cannula and wide resection of anterior tracheal wall. Another common cause is psychologic dependency. Treatments may be categorized into dilatation with or without injection of steroid, dilatation and prolonged stent, luminal augmentation and resection of the stenosis with primary reanastomosis. Recently authors experienced a case of the decannulation difficulty in a 2 - year - old which was developed after tracheostomy for the removal of bronchial foreign body and was treated with a silicon T -tube stent with good result.

  • PDF

Airway foreign body occurs unintentionally during anesthetic management of patient with asthma

  • Cho, Woo Jin;Yun, So Hui;Choi, Yun Suk;Lee, Bang Won;Kim, Mi Ok;Park, Jong Cook
    • Journal of Medicine and Life Science
    • /
    • v.16 no.2
    • /
    • pp.43-45
    • /
    • 2019
  • Intraoperative delivery of salbutamol (${\beta}_2$ agonist) through a breathing circuit may be performed in asthma patient. A 28-year-old woman with a history of asthma was diagnosed with chronic sinusitis and bilateral nasal polyps, and an endoscopic sinus surgery was performed. The patient was recommended salbutamol nebulization every 4 hours during the perioperative period because of the risk of asthma attack. At the end of the operation, when salbutamol was sprayed through the tube before extubation and the connector tip went inside the tube during injection. The patient was immediately referred to the pulmonary medicine department for bronchoscopy, where the foreign body was removed safely without any complications. When general anesthesia is performed on a patient who usually uses an inhaler for asthma, caution is required because the tip that connects the inhaler and the breathing circuit can aspirate into the endotracheal tube and enter the lungs when applying the inhaler before waking up the patient.