• 제목/요약/키워드: bridge load rating

검색결과 66건 처리시간 0.027초

보조회로도 영전압영전류스위칭하는 DC-DC 변환기 (A Fully Soft Switched Full Bridge DC-DC converter)

  • 전성즙;조규형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2512-2514
    • /
    • 1999
  • A new zero voltage and zero current switching(ZVZCS) full bridge DC-DC converter with transformer isolation is proposed for arc welding machines. The proposed DC-DC converter uses an auxiliary transformer to obtain ZCS for leading leg, which provides load current control capability even in short circuit condition. The auxiliary circuit also operates in ZVZCS mode. The power rating of the auxiliary transformer is about 10% of the main transformer. The operation is verified by experiments for 12[KW] prototype.

  • PDF

Assessment of a concrete arch bridge using static and dynamic load tests

  • Caglayan, B. Ozden;Ozakgul, Kadir;Tezer, Ovunc
    • Structural Engineering and Mechanics
    • /
    • 제41권1호
    • /
    • pp.83-94
    • /
    • 2012
  • Assessment of a monumental concrete arch bridge with a total length of 210 meters having three major spans of 30 meters and a height of 65 meters, which is located in an earthquake-prone region in southern part of the country is presented in this study. Three-dimensional finite element model of the bridge was generated using a commercially available general finite element analysis software and based on the outcomes of a series of in-depth acceleration measurements that were conducted on-site, the model was refined. By using the structural parameters obtained from the dynamic and the static tests, calibrated model of the bridge structure was obtained and this model was used for necessary calculations regarding structural assessment and evaluation.

Design and Control of the Phase Shift Full Bridge Converter for the On-board Battery Charger of Electric Forklifts

  • Kim, Tae-Hoon;Lee, Seung-Jun;Choi, Woo-Jin
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.113-119
    • /
    • 2012
  • This paper describes the design and control of a phase shift full bridge converter with a current doubler, which can be used for the on-board charger for the lead-acid battery of electric forklifts. Unlike the common resistance load, the battery has a large capacitance element and it absorbs the entire converter output ripple current, thereby shortening the battery life and degrading the system efficiency. In this paper a phase shift full bridge converter with a current doubler has been adopted to decrease the output ripple current and the transformer rating of the charger. The charge controller is designed by using the small signal model of the converter, taking into consideration the internal impedance of the battery. The stability and performance of the battery charger is then verified by constant current (CC) and constant voltage (CV) charge experiments using a lead-acid battery bank for an electric forklift.

GFRP 슬래브 교량의 장기성능 평가 (Long-Term Performance Evaluation of a GFRP Slab Bridge)

  • 지효선
    • 한국강구조학회 논문집
    • /
    • 제24권3호
    • /
    • pp.349-360
    • /
    • 2012
  • 본 논문은 GFRP 슬래브 교량 상부구조에 대한 장기성능, 내하력, 사용성 및 구조적 안전성의 상세한 평가를 기술하고 있다. 국내 최초로 완전 GFRP 슬래브 교량이 2002년 5월에 가설되었다. GFRP 슬래브 교량은 단순지지로 지간 10.0 m, 폭 8.0 m 인 2차선으로 설계되었다. 본 GFRP 슬래브교량은 콜루게이트(corrugate) 심재를 갖는 샌드위치 구조로서 유리섬유와 비닐 에스테르를 사용하여 수적층으로 제작되었다. GFRP 슬래브 교량의 장기성능 평가는 2002년 수행되었던 동일한 현장재하시험으로 2004, 2011년에 실시되었다. GFRP 슬래브교량은 예상되었던 대로 공용 중에서 구조적 문제점이 없이 성능이 잘 발휘되고 있었음을 평가를 통하여 나타내고 있다. 본 평가 자료는 GFRP 슬래브 교량의 내하력 평가에 대한 기초자료와 완전 GFRP 슬래브교량 상부구조의 장기성능의 일부자료로서 제공될 수 있을 것이다.

쳬계신뢰성에 기초한 사장교의 안전도 및 내하력 평가 (System Reliability-Based Safety and Capacity Evaluation of Cable-Stayed Bridges)

  • 조효남;이승재;임종권;김보헌
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.105-112
    • /
    • 1996
  • A practical approach for the assessment of system reliability-based safety and load carring capacity under vehicle traffics is proposed for the realistic evaluation of safety and rating of cable-stayed bridges. A partial event tree analysis model incorporating major critical failure paths is suggested as a practical tool for the system reliability analysis and system reliability-based capacity rating. The proposed approach for the system reliability analysis and system reliability-based rating is applied to the safety assessment of the Jindo Bridge which is one of two existing cable-stayed bridges in Korea. The results of analyses at the system level based on the system reliability are compared with those at the element level.

  • PDF

외부 긴장재로 보강된 강합성보의 내하율 산정식을 이용한 초기 긴장력 결정 (Determination of the Initial Tendon Force using Rating Factor Equation in Composite Girders Strengthened with External Tendons)

  • 최동호;정상환;유동민
    • 한국강구조학회 논문집
    • /
    • 제17권5호통권78호
    • /
    • pp.527-536
    • /
    • 2005
  • 외부 긴장재를 이용한 보강공법은 효과적인 보강기술의 하나로써 연구되고 있으며 그 적용사례가 증가하고 있다. 본 논문에서는 기존 강합성 교량의 내하력 향상을 위해 외부 긴장재의 초기 긴장력 결정 방법을 제안하였다. 긴장재의 배치 형상과 재하되는 활하중의 종류에 따른 증가 프리스트레스력 계산식을 구하여 강합성보의 보강효과를 수치적으로 분석하였다. 증가 프리스트레스력을 고려한 내하율 산정 방법을 제안하여 긴장재 개수와 초기 긴장력의 계산 방법을 제시하였다. 제안된 방법을 실교량에 적용하여 합리성을 보였다.

아크 용접에 적합하며 1차 측 보조회로를 사용하는 영전압-영전류 직류-직류 컨버터 (A Primary-Side-Assisted Zero-Voltage and Zero-Current Switching Full Bridge DC-DC Converter with Transformer Isolation for Arc Welding)

  • 전성집;조규형
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권10호
    • /
    • pp.683-692
    • /
    • 2000
  • A new primary-side-assisted zero-voltage and zero-current switching full bridge DC-DC converter with transformer isolation is proposed. The auxiliary circuit adopted to assist ZCS for the leading leg is composed of only one small transformer and two diodes. It has a simple and robust structure, and load current control capability even in short circuit conditions. Possibility of magnetic saturation due to asymmetricity of circuits or transient phenomena is greatly reduced, which is a very attractive feature in DC/DC converters with transformer isolation. The power rating of the auxiliary transformer is about 10% of that of the main transformer. Operation of a 12.5KW prototype designed for welding application was verified by experiments.

  • PDF

실측자료에 기초한 공용년수 증가에 따른 교량 내하력 분석 (Analysis of Load Carrying Capacity of Bridges Based on Field Data with Serviced Time)

  • 경갑수;이영일;이성진
    • 대한토목학회논문집
    • /
    • 제35권1호
    • /
    • pp.31-38
    • /
    • 2015
  • 본 논문에서는 한국시설안전공단에서 수행한 정밀안전진단자료를 수집 분석하여 공용년수의 증가에 따른 내하력 변화 양상을 조사하였다. 연구결과, 공용내하율이 평가자의 주관 등 여러 가지 조건으로 공용기간에 따라 큰 편차를 보이는 것을 알 수 있었다. 따라서, 기존의 내하력 평가에 관한 다양한 문제점을 분석하여 편차를 보정할 수 있는 개선된 방안을 제시하였으며, 이 방법은 공용중인 교량의 보강 주기와 우선순위의 결정, 공용수명의 추정 등 효율적인 유지관리에 활용될 수 있을 것으로 기대된다.

내하율을 이용한 강합성보의 외부 프리텐션과 포스트텐션 보강 설계 (Strengthening Design by External Pre-tensioning and Post-tensioning Methods for Steel-concrete Composite Girders using Rating Factor)

  • 최동호;유동민;정구상;박경부
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제11권5호
    • /
    • pp.123-134
    • /
    • 2007
  • 본 논문은 기존 강합성 교량의 내하력 향상을 목적으로 외부 긴장재의 초기 긴장력 결정 방법을 제시하였다, 외부 긴장력은 콘크리트 슬래브 재시공 전과 후에 각각 적용하였다. 활하중에 의하여 발생하는 증가 프리스트레스력을 고려한 내하율식을 제안하여 긴장재 개수와 초기 긴장력의 결정 과정을 제시하였다. 기존 강합성 교량의 내하율 향상에 적용하여 그 타당성을 입증하였다.

직선배치된 외부 긴장재로 보강된 2경간 강합성교의 증가 프리스트레스력을 고려한 내하율 산정식을 이용한 보강설계 (Strengthening Design Using Rating Factor Considering Increment of Tendon Force for Two-Span Steel-concrete Composite Bridges Strengthened by Straight External Tendons)

  • 최동호;유훈;김용식;김성원
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제13권2호통권54호
    • /
    • pp.153-164
    • /
    • 2009
  • 본 논문에서는 2경간 강합성교량의 내하력을 향상시키기 위해, 외부 긴장재로 보강하는 방법을 제시하였다. 긴장재를 직선 배치하였을 경우, 외부하중으로 인한 증가 프리스트레스력을 가상일의 원리로 구하였고, 증가 프리스트레스를 고려한 내하율 산정식을 제시하였다. 제안된 내하율 산정식으로부터, 긴장재 개수와 초기 긴장력의 계산방법을 제시하였다. 본 방법을 2경간 강합성교량에 적용하여, 산정식의 타당성과 합리성을 검증하였다.