• Title/Summary/Keyword: breathing

Search Result 1,540, Processing Time 0.032 seconds

Relationship between Depressive Symptoms and Sleep Parameters in Patients with Obstructive Sleep Apnea Syndrome (폐쇄성 수면무호흡증 환자의 우울증상 정도에 따른 수면 양상)

  • Won, Chang-Yeon;Lee, Seung-Hee;So, Min-Ah;Lee, Jin-Sung;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.14 no.2
    • /
    • pp.92-98
    • /
    • 2007
  • Objectives: Obstructive sleep apnea syndrome (OSAS) is the most common form of sleep-disordered breathing and often presents with comorbid depressive symptoms. In this study, we evaluated the relationship between depressive symptoms and sleep parameters as measured by nocturnal polysomnography (NPSG) and simultaneous wrist actigraphy. Methods: Two hundred sixty-four subjects with clinically suspected cases of OSAS underwent one-night polysomnography, while simultaneously wearing a wrist actigraphy device. They also completed two questionnaires;the Epworth Sleepiness Scale-Korean version (ESS-K) and the Beck Depression Inventory (BDI). Of the cases studied, 105 subjects were proven by NSPG to have OSAS without other sleep disorders. NPSG and wrist actigraphy data from the subjects were analyzed. Pearson correlation and paired t-test were used in order to evaluate the relationship between depressive symptoms and sleep-parameters. Results: Mean age of the subjects was $46.1{\pm}13.1$ years. Means of the ESS-K score and BDI scores were $10.9{\pm}4.7$ and $12.8{\pm}8.1$, respectively. NPSG sleep parameters significantly differed from those of wrist actigraphy. There was no correlation found between subjects' respiratory disturbance index (RDI) and BDI scores. When directly comparing sleep parameters between subjects who were more depressed versus subjects who were less depressed, both total sleep time and sleep efficiency were decreased in the more depressed. A correlation between RDI and ESS-K scores was also found in the more depressed group. Conclusions: Although our findings suggest that there is no relationship between RDI and depressive symptoms, there are other significant differences in the sleep parameters between subjects who are more depressed versus those without depression. We recommend that patients with depression should also be evaluated for clinical symptoms of OSAS.

  • PDF

Prediction of Target Motion Using Neural Network for 4-dimensional Radiation Therapy (신경회로망을 이용한 4차원 방사선치료에서의 조사 표적 움직임 예측)

  • Lee, Sang-Kyung;Kim, Yong-Nam;Park, Kyung-Ran;Jeong, Kyeong-Keun;Lee, Chang-Geol;Lee, Ik-Jae;Seong, Jin-Sil;Choi, Won-Hoon;Chung, Yoon-Sun;Park, Sung-Ho
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.132-138
    • /
    • 2009
  • Studies on target motion in 4-dimensional radiotherapy are being world-widely conducted to enhance treatment record and protection of normal organs. Prediction of tumor motion might be very useful and/or essential for especially free-breathing system during radiation delivery such as respiratory gating system and tumor tracking system. Neural network is powerful to express a time series with nonlinearity because its prediction algorithm is not governed by statistic formula but finds a rule of data expression. This study intended to assess applicability of neural network method to predict tumor motion in 4-dimensional radiotherapy. Scaled Conjugate Gradient algorithm was employed as a learning algorithm. Considering reparation data for 10 patients, prediction by the neural network algorithms was compared with the measurement by the real-time position management (RPM) system. The results showed that the neural network algorithm has the excellent accuracy of maximum absolute error smaller than 3 mm, except for the cases in which the maximum amplitude of respiration is over the range of respiration used in the learning process of neural network. It indicates the insufficient learning of the neural network for extrapolation. The problem could be solved by acquiring a full range of respiration before learning procedure. Further works are programmed to verify a feasibility of practical application for 4-dimensional treatment system, including prediction performance according to various system latency and irregular patterns of respiration.

  • PDF

Comparison of Passive Diffusional Organic Vapor Samplers with Charcoal Tubes for the Measurement of Mixed Organic Solvents (확산형 포집기와 활성탄관을 이용한 공기중 혼합 유기용제 측정에 관한 연구)

  • Ahn, Kyu-Dong;Yeon, You-Yong;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.127-136
    • /
    • 1994
  • Diffusional sampling devices offer many advantages for measuring concentration levels of industrial contaminants than the conventional pump and charcoal tubes because they are lightweight, require no power, pump or tubing. This study designed to evaluate and compare the sampling performance of passive sampler to charcoal tube from mixed organic solvent workplace with 181 organic solvent using workers working in different concentration of organic solvents. All study workers kept both devices in their breathing zone simultaneuosly in the workplaces, and the sampling analytical results were compared with those of charcoal tube. The results obtained are as follows: 1. The concentrations of toluene and xylene measured by passive sampler were slightly higher than those of charcoal tube, but there were no significant statistical differences between two methods. 2. The concentrations of MEK and cyclo-hexanone measured by passive sampler in low exposure workplace (below 0.20 of MEK TLV levels and 0.1 of cyclo-hexanone TLV levels) were about 2 times higher than that of charcoal tube sampling. While, absorption efficiency of passive sampler was reduced according to increasing concentration measurements of MEK and cyclo-hexanone in air. 3. The ratios of concentrations of toluene, xylene, MEK and cyc1o-hexanone measured by passive sampler over those measured by charcoal tube were 1.11, 1.07, 1.63 and 3.65 respectively. 4. The percentages of concentration of passive samplers within 0.75 and 1.25 of charcoal tube value as a reference value of 1.0 were 57% in toluene, 74% in xylene, 34% in MEK and 32% in cyclo-hexanone respectively. 5. The correlation coefficients of toluene, xylene, MEK and cyclo-hexanone between passive sampler and charcoal tube sampler were 0.963, 0.957, 0.943 and 0.562 with statistical significance.

  • PDF

An Effect of Time Gating Threshold (TGT) on the Delivered Dose at Internal Organ with Movement due to Respiration (호흡에 의해 내부 움직임을 갖는 장기에 전달되는 선량에서 Time Gating Threshold (TGT)의 효과)

  • Kim Yon Lae;Chung Jin Bum;Chung Won Kyun;Hong Semie;Suh Tae Suk
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.89-96
    • /
    • 2005
  • In this study, we investigated the effect of time gating threshold on the delivered dose at a organ with internal motion by respiration. Generally, the internal organs have minimum motion at exhalation during normal breathing. Therefore to compare the dose distribution time gating threshold, in this paper, was determined as the moving region of target during 1 sec at the initial position of exhalation. The irradiated fields were then delivered under three conditions; 1) non-moving target 2) existence of the moving target in the region of threshold (1sec), 3) existence of the moving target region out of threshold (1.4 sec, 2 sec). And each of conditions was described by the moving phantom system. It was compared with the dose distributions of three conditions using film dosimetry. Although the treatment time increased when the dose distributions was obtained by the internal motion to consider the TGT, it could be obtained more exact dose distribution than in the treatment field that didn't consider the internal motion. And it could be reduced the unnecessary dose at the penumbra region. When we set up 1.4 sec of threshold, to reduce the treatment time, it could not be obtained less effective dose distribution than 1 sec of threshold. Namely, although the treatment time reduce, the much dose was distributed out of the treatment region. Actually when it is treated the moving organ, it would rather measure internal motion and external motion of the moving organ than mathematical method. If it could be analyzed the correlation of the internal and external motion, the treatment scores would be improved.

  • PDF

A Study on the Effects of the Breath Efficiency & Lung Capacity Improvement Using Recorder Playing Focused on Breath Training (리코더 연주를 통한 뇌졸중 노력성 폐활량과 호흡 효율성 향상 연구)

  • Choi, Sung Joo
    • Journal of Music and Human Behavior
    • /
    • v.4 no.1
    • /
    • pp.31-46
    • /
    • 2007
  • The purpose of the study was to improve the efficiency of Breath & Forced Vital Capacity(FVC) of Stroke Patients Using Record Playing Focused on Breath Training. The Training of Forced Vital Capacity(FVC) is focused on trunk muscles reinforce for Breathing. So the study tried to play Recorder for reinforcing FVC. The play included the two parts. One was for solo play, the other was play in concert base on solo play using Korea country song, Arirang. The Recorder play used abdominal breath, Pursed-lip & Paced methods. The course of play included Long Tone, Staccato, Crescendo, Decrescendo and throughout the course we tried to improve the efficiency & Quantity of breathe. Experiment performed at Social welfare institute for the old. They played & checked FVC, $FEV_1$, $FEV_1/FVC$ before & after breathe 19 times for 6 weeks using Spirovit SP-1, Schiller. After experiment we performed statical process(p<0.05) using statical Package software. The findings were as follows: Analysis for Experiment showed the numerical Value of increasing Of FVC, $FEV_1$, $FEV_1/FVC$. Increasing Percentage of Measured/Predicted FVC, $FEV_1$ (or calculated based on theory) ration was 25%, 13% and Quantity of FVC, $FEV_1$ 35%, 40%. Also $FEV_1/FVC$ Ratio(showed efficiency of breathe) raised 13%. And experiment data was confirmed by statical process. The experiment data was valuable under p<0.05. In Conclusion we think the results of experiment showed the efficiency of Music therapy for Breathe(FVC, $FEV_1$, $FEV_1/FVC$) reinforce.

  • PDF

A Study Analyzing Nursing Diagnoses and Nursing Interventions used in a Demonstration Home Care Project (가정간호 시범사업 간호진단 및 간호중재 분석 연구)

  • Suh, Mi-Hae;Lee, Hae-Won;Chun, Choon-Young
    • The Korean Nurse
    • /
    • v.34 no.5
    • /
    • pp.52-67
    • /
    • 1996
  • As home care in developing and becoming part of the health care delivery system in Korea, it is necessary to examine the use of nursing diagnoses and related nursing interventions with a view to increasing the standardization of nursing recording. This study was done to examine the nursing diagnosis and related nursing interventions used in home care. Data were collected using a chart review of the nursing notes written for the home care given to 38 patients who had pulmonary diseases or traumatic brain or spinal cord injuries and who had received home care as part of a demonstration home care project in a college of Nursing in Seoul. Early on in the project discussions as to format and use to nursing diagnosis was done and a tool was developed based on Gordon's eleven functional catergories with the addition of categories to cover family and environment. This tool was used in the data collection. Data included nursing diagnosis, etiologies and interventions. Real numbers and percentages were used in the analysis. The results show that the most frequently used diagnoses were in the category of physical function (75.6%), followed by the category of emotional and social function (21.8%). The least frequently used category was the one for family and environment (2.6%). The order of the frequency of recorded nursing interventions was the same, 82.3% for physical function, 16.2% of emotional and social function and 1.5% for family and environment. Under the category of physical functioning the most frequently used nursing diagnoses were related to mobility (62.2%), nutrition (23.6%) and elimination (11.9%). The frequencies of nursing interventions for these three diagnostic categories were 69.8%, 16.0% and 10.8% respectively. For emotional and social functioning, the most frequently used diagnoses were for cognition-perception (37.1%), self-perception (30.6%) and perception of health (23.7%). The ordering of the frequency of nursing interventions varied slightly. The most frequently used interventions were for the category of self-perception (31.7%) followed by cognition-perception (24.1%) and perception of health (22.9%). Looking at individual diagnoses, it was found that within the categroy of physical functioning, the most frequently used diagnosis was "impaired physical mobility" (29.5%) and this diagnosis involved 43.9% of the interventions. This was followed by "ineffective breathing pattern" (19.4%) with 17.7% of interventions, and "alteration in nutrition, less than body requirements" (11.2%) with 8.1% of the interventions. For the emotional social category, noncompliance was the most frequently used nursing diagnosis (18.2%) with 19.2% of the interventions. This was followed by "anxiety" (13.4%) with 13.6% of the interventions and by "knowledge deficit" (13.4%) but with only 5.5% of the interventions. The other diagnoses and interventions did not follow this pattern of frequency. Although there were a large number of diagnostic and intervention events, the number of actual diagnoses and interventions used were relatively small ranging from six interventions for "knowledge deficit" to 40 interventions for "imparied physical mobility". From this it can be concluded that the results of this study could be used as basic data for the development of standardized charts with respect to nursing diagnosis and interventions for clients with pulmonary disease and clients with traumatic brain or spinal cord injuries. Interventions that were direct care activities (1178) were much more frequent that education (430), and assessment and observation (148). There were also few diagnoses or interventions related to the family and the environment. This suggests two areas that need to be developed in home care and that need to be considered in the development of standardized records for use in home care.

  • PDF

Enhancement of the Deformable Image Registration Accuracy Using Image Modification of MV CBCT (Megavoltage Cone-beam CT 영상의 변환을 이용한 변환 영상 정합의 정확도 향상)

  • Kim, Min-Joo;Chang, Ji-Na;Park, So-Hyun;Kim, Tae-Ho;Kang, Young-Nam;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.28-34
    • /
    • 2011
  • To perform the Adaptive Radiation Therapy (ART), a high degree of deformable registration accuracy is essential. The purpose of this study is to identify whether the change of MV CBCT intensity can improve registration accuracy using predefined modification level and filtering process. To obtain modification level, the cheese phantom images was acquired from both kilovoltage CT (kV CT), megavoltage cone-beam CT (MV CBCT). From the cheese phantom images, the modification level of MV CBCT was defined from the relationship between Hounsfield Units (HUs) of kV CT and MV CBCT images. 'Gaussian smoothing filter' was added to reduce the noise of the MV CBCT images. The intensity of MV CBCT image was changed to the intensity of the kV CT image to make the two images have the same intensity range as if they were obtained from the same modality. The demon deformable registration which was efficient and easy to perform the deformable registration was applied. The deformable lung phantom which was intentionally created in the laboratory to imitate the changes of the breathing period was acquired from kV CT and MV CBCT. And then the deformable lung phantom images were applied to the proposed method. As a result of deformable image registration, the similarity of the correlation coefficient was used for a quantitative evaluation of the result was increased by 6.07% in the cheese phantom, and 18% in the deformable lung phantom. For the additional evaluation of the registration of the deformable lung phantom, the centric coordinates of the mark which was inserted into the inner part of the phantom were measured to calculate the vector difference. The vector differences from the result were 2.23, 1.39 mm with/without modification of intensity of MV CBCT images, respectively. In summary, our method has quantitatively improved the accuracy of deformable registration and could be a useful solution to improve the image registration accuracy. A further study was also suggested in this paper.

How to Determine the Moving Target Exactly Considering Target Size and Respiratory Motion: A Phantom Study (종양의 움직임과 호흡주기에 따른 체적 변화에 대한 연구: 팬텀 Study)

  • Kim, Min-Su;Back, Geum-Mun;Kim, Dae-Sup;Kang, Tae-Yeong;Hong, Dong-Ki;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.145-153
    • /
    • 2010
  • Purpose: To accurately define internal target volume (ITV) for treatment of moving target considering tumor size and respiratory motion, we quantitatively investigated volume of target volume delineated on CT images from helical CT and 4D CT scans. Materials and Methods: CT images for a 1D moving phantom with diameters of 1.5, 3, and 6 cm, acryl spheres were acquired using a LightSpeed $RT^{16}CT$ simulator. To analyze effect of tumor motion on target delineation, the CT image of the phantoms with various moving distances of 1~4 cm, and respiratory periods of 3~6 seconds, were acquired. For investigating the accuracy of the target trajectory, volume ratio of the target volumes delineated on CT images to expected volumes calculated with diameters of spherical phantom and moving distance were compared. Results: Ratio$_{helical}$ for the diameter of 1, 5, 3, and 6 cm targets were $32{\pm}14%$, $45{\pm}14%$, and $58{\pm}13%$, respectively, in the all cases. As to 4DCT, RatioMIP were $98{\pm}8%$, $97{\pm}5%$, and $95{\pm}1%$, respectively. Conclusion: The target volumes delineated on MIP images well represented the target trajectory, in comparison to those from helical CT. Target volume delineation on MIP images might be reasonable especially for treatment of early stage lung cancer, with meticulous attention to small size target, large respiratory motion, and fast breathing.

  • PDF

Assessment of Computed Tomographic Lung Density in Beagle and Shihtzu Dogs : Influence of Position and Positive End Expiratory Pressure (비글과 시츄견에서 호기말 양압에 따른 전산화 단층촬영상의 폐밀도의 평가)

  • Kim, Tae-Hun;Chang, Jin-Hwa;Yun, Seok-Ju;Yoon, Jung-Hee;Chang, Dong-Woo
    • Journal of Veterinary Clinics
    • /
    • v.27 no.3
    • /
    • pp.273-283
    • /
    • 2010
  • The objective of this study was to measure densities in various areas of the normal canine lung with computed tomography (CT) depending on influences of gravity and the degree of lung inflation and to determine optimal positions and positive end expiratory pressure of canine lung for CT scanning. In each eight normal Beagle and Shihtzu dogs, a respiratory breathhold maneuver without spontaenous breathing at different positive end expiratory pressure (PEEP) of 0 mmHg, 10 mmHg and 20 mmHg was applied with the position of right and left lateral recumbency, sternal recumbency, and dorsal recumbency and spiral-CT scans of the total lung were acquired. Slices were selected at three levels through the apex, middle and basal lung at the aortic arch, carina and just above the diaphragm and lung density was measured in the dorsal, ventral, and lateral portions of the peripheral lung field. Lung density in dependent areas was higher than in nondependent areas (p < 0.05) regardless of species, positions, anatomic locations at the PEEP of 0 mmHg and 10 mmHg. However, no significant difference of lung density was found at PEEP of 20 mmHg in both species except the dorsal recumbency in Shihtzu dogs. This density gradient in the dependent areas is strongly influenced by PEEP (p < 0.05). In the four positions on the CT gantry, the lung density at the dependent and nondependent location of the lung was greater at the aortic arch than at the base (p < 0.05). Lung density decreased on identical location according to increase of PEEP (p < 0.05). There was no significant difference between right and left lung density at sternal and dorsal recumbency and no significant difference of the dorsal, ventral, and lateral portions of lung density at the right and left recumbency under identical pressure. It is implied that during chest CT scan with 20 mmHg of positive end expiratory pressure with right or left lateral recumbency, canine lung density do not influenced by gravity or anatomic location.

Change of Prevalence and Clinical Features of Mycoplasma Pneumonia in Infants Younger than 2 Years (2세 미만아에서의 Mycoplasma 폐렴의 발생 비율 변화 및 임상 양상)

  • Kim, Ji Young;Lee, Eun Ho;Park, Ho Jin;Lee, Su Jin;O, Sung Hee;Jung, Ji Young
    • Pediatric Infection and Vaccine
    • /
    • v.12 no.1
    • /
    • pp.86-94
    • /
    • 2005
  • Purpose : Recently, it has been reported that the prevalence of mycoplasam pneumonia in infants is increasing. We studied the change of prevalence and clinical features in infants for recent three years. Methods : We evaluated the clinical records of 206 patients diagnosed as mycoplasma pneumonia during Mar. 2000~Feb. 2003. We retrospectively analyzed epidemiologic, clinical, serologic and radiologic difference between children younger than 24 months and others. Results : Among 206 patients, 111 were boys and 95 were girls. Mean age of onset was $5.12{\pm}2.91$ years and lowered annually(P>0.05). 28 patinets(13.6%) were younger than 24 months and annual prevalence in this group increased(P<0.05). Main clinical features included cough, fever, coarse breathing sound(=sputum), rhinorrhea and dyspnea. There was no clinical difference between children younger than 24 months and others, except for rhinorrhea and dyspnea which more developed frequently in children younger than 24 months (P<0.05). There was also no serologic and radiologic difference for these groups. Conclusion : Annual mean age of onset lowered and annual prevalence of younger than 24 months increased with mycoplasma pneumonia. Therefore, we need careful attention to differentiate Mycoplasma pneumoniae as causal organism of pneumonia in children younger than 24 months.

  • PDF