• 제목/요약/키워드: breast implants

검색결과 102건 처리시간 0.03초

Comprehensive Evaluation of the Current Knowledge on Breast Implant Associated-Anaplastic Large Cell Lymphoma

  • Yoo, Hyokyung;Park, Ji-Ung;Chang, Hak
    • Archives of Plastic Surgery
    • /
    • 제49권2호
    • /
    • pp.141-149
    • /
    • 2022
  • Breast implant-associated anaplastic large cell lymphoma (BIA-ALCL) is a recently spotlighted T-cell origin non-Hodgkin's lymphoma with an increasing incidence of over 800 cases and 33 deaths reported worldwide. Development of BIA-ALCL is likely a complex process involving many factors, such as the textured implant surface, bacterial biofilm growth, immune response, and patient genetics. As the incidence of BIA-ALCL is expected to increase, it is important for all surgeons and physicians to be aware of this disease entity and acquire thorough knowledge of current evidence-based guidelines and recommendations. Early detection, accurate diagnosis, and appropriate treatment are the foundations of current care.

Late Seroma in Breast Implants: A Coronavirus Disease 2019 Phenomenon?

  • Chan, Stephanie L.S;Mok, James Wan Loong
    • Archives of Plastic Surgery
    • /
    • 제49권5호
    • /
    • pp.611-613
    • /
    • 2022
  • The coronavirus disease 2019 (COVID-19) pandemic has been challenging in all aspects of the medical field with new clinical presentations constantly arising. Plastic surgeons are not immune to this and need to be aware of their implications. There has been a recent report of late periprosthetic seroma (breast implant) as a clinical manifestation of COVID-19 infection. To our knowledge, this phenomenon has not been further reported. We present a 53-year-old immunocompromised lady who developed late seroma after COVID-19 infection. She eventually required explantation of the implant and is awaiting autologous reconstruction. It is likely that we will increasingly continue to see this phenomenon of implant complications as a result of COVID-19 infection and should be watchful, especially regarding potential immunocompromised patients.

유방촬영 시 몬테칼로 전사모사를 이용한 유방 성형 환자의 장기선량 평가 (Assessment of Organ Dose in Mammoplasty Patient by Monte Carlo Simulation during Mammography)

  • 김지수;조용인;김정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권5호
    • /
    • pp.337-341
    • /
    • 2020
  • Although the screening with a mammography has been shown to be economical, simple and effective in detecting breast cancer, it is accompanied by the risk from radiation. Therefore, this study analyzed the glandular dose and organ dose according to the target-filter combination and the presence and absence of implants using Monte Carlo simulation. The results indicate that at a tube voltage of 30 kV and a tube current of 50 mAs, the dose increased in the order of Mo/Mo. Mo/Rh, Rh/Rh and W/Rh in proportion to the atomic number of the target-filter. In addition, in phantom without implant a reduction in dose was seen when compared to the phantom with implant. The organ dose was highest in the lens except for the breast on the examination side regardless of the presence or absence of the implant. These results may contribute to use basic data for the diagnostic reference level of breast plastic surgery patients.

Considerations for patient selection: Prepectoral versus subpectoral implant-based breast reconstruction

  • Yang, Jun Young;Kim, Chan Woo;Lee, Jang Won;Kim, Seung Ki;Lee, Seung Ah;Hwang, Euna
    • Archives of Plastic Surgery
    • /
    • 제46권6호
    • /
    • pp.550-557
    • /
    • 2019
  • Background In recent years, breast implants have been frequently placed in the subcutaneous pocket, in the so-called prepectoral approach. We report our technique of prepectoral implant-based breast reconstruction (IBR), as well as its surgical and aesthetic outcomes, in comparison with subpectoral IBR. We also discuss relevant considerations and pitfalls in prepectoral IBR and suggest an algorithm for the selection of patients for IBR based on our experiences. Methods We performed 79 immediate breast reconstructions with a breast implant and an acellular dermal matrix (ADM) sling, of which 47 were subpectoral IBRs and 32 were prepectoral IBRs. Two-stage IBR was performed in 36 cases (20 subpectoral, 16 prepectoral), and direct-to-implant IBR in 43 cases (27 prepectoral, 16 subpectoral). The ADM sling supplemented the inferolateral side of the breast prosthesis in the subpectoral group and covered the entire anterior surface of the breast prosthesis in the prepectoral group. Results The postoperative pain score was much lower in the prepectoral group than in the subpectoral group (1.78 vs. 7.17). The incidence of seroma was higher in the prepectoral group (31.3% vs. 6.4%). Other postoperative complications, such as surgical site infection, flap necrosis, implant failure, and wound dehiscence, occurred at similar rates in both groups. Animation deformities developed in 8.5% of patients in the subpectoral group and rippling deformities were more common in the prepectoral group (21.9% vs. 12.8%). Conclusions The indications for prepectoral IBR include moderately-sized breasts with a thick well-vascularized mastectomy flap and concomitant bilateral breast reconstruction with prophylactic mastectomy.

A Prospective Analysis of Dynamic Loss of Breast Projection in Tissue Expander-Implant Reconstruction

  • Mioton, Lauren M.;Jordan, Sumanas W.;Kim, John Y.S.
    • Archives of Plastic Surgery
    • /
    • 제42권3호
    • /
    • pp.309-315
    • /
    • 2015
  • Background Breast projection is a critical element of breast reconstruction aesthetics, but little has been published regarding breast projection as the firm expander is changed to a softer implant. Quantitative data representing this loss in projection may enhance patient education and improve our management of patient expectations. Methods Female patients who were undergoing immediate tissue-expander breast reconstruction with the senior author were enrolled in this prospective study. Three-dimensional camera software was used for all patient photographs and data analysis. Projection was calculated as the distance between the chest wall and the point of maximal projection of the breast form. Values were calculated for final tissue expander expansion and at varying intervals 3, 6, and 12 months after implant placement. Results Fourteen breasts from 12 patients were included in the final analysis. Twelve of the 14 breasts had a loss of projection at three months following the implant placement or beyond. The percentage of projection lost in these 12 breasts ranged from 6.30% to 43.4%, with an average loss of projection of 21.05%. Conclusions This study is the first prospective quantitative analysis of temporal changes in breast projection after expander-implant reconstruction. By prospectively capturing projection data with three-dimensional photographic software, we reveal a loss of projection in this population by three months post-implant exchange. These findings will not only aid in managing patient expectations, but our methodology provides a foundation for future objective studies of the breast form.

The Effect of Sterile Acellular Dermal Matrix Use on Complication Rates in Implant-Based Immediate Breast Reconstructions

  • Lee, Jun Ho;Park, Youngsoo;Choi, Kyoung Wook;Chung, Kyu-Jin;Kim, Tae Gon;Kim, Yong-Ha
    • Archives of Plastic Surgery
    • /
    • 제43권6호
    • /
    • pp.523-528
    • /
    • 2016
  • Background The use of acellular dermal matrix (ADM) in implant-based immediate breast reconstruction has been increasing. The current ADMs available for breast reconstruction are offered as aseptic or sterile. No published studies have compared aseptic and sterile ADM in implant-based immediate breast reconstruction. The authors performed a retrospective study to evaluate the outcomes of aseptic versus sterile ADM in implant-based immediate breast reconstruction. Methods Implant-based immediate breast reconstructions with ADM conducted between April 2013 and January 2016 were included. The patients were divided into 2 groups: the aseptic ADM (AlloDerm) group and the sterile ADM (MegaDerm) group. Archived records were reviewed for demographic data and postoperative complication types and frequencies. The complications included were infection, flap necrosis, capsular contracture, seroma, hematoma, and explantation for any cause. Results Twenty patients were reconstructed with aseptic ADM, and 68 patients with sterile ADM. Rates of infection (15.0% vs. 10.3%), flap necrosis (5.0% vs. 7.4%), capsular contracture (20.0% vs. 14.7%), seroma (10.0% vs. 14.7%), hematoma (0% vs. 1.5%), and explantation (10.0% vs. 8.8%) were not significantly different in the 2 groups. Conclusions Sterile ADM did not provide better results regarding infectious complications than aseptic ADM in implant-based immediate breast reconstruction.

코헤시브 실리콘 젤 유방삽입물을 이용한 유방확대술 후 발생한 유방삽입물의 흉강내로의 이탈 및 파열 증례보고 (Rupture and Intrapleural Migration of a Cohesive Silicone Gel Implant after Augmentation Mammoplasty: A Case Report)

  • 이준용;김한구;김우섭;박보영;배태희;최주원
    • Archives of Plastic Surgery
    • /
    • 제38권3호
    • /
    • pp.323-325
    • /
    • 2011
  • Purpose: Breast implant ruptures and displacement are problematic complications after augmentation mammoplasty. The authors report a patient whose cohesive silicone gel implant ruptured and migrated into the pleural cavity after augmentation mammoplasty. Methods: A 23-year-old female had received augmentation mammoplasty at a local clinic a week before visiting our hospital. When the patient's doctor performed a breast massage on the sixth postoperative day, the left breast became flattened. The doctor suspected a breast implant rupture and performed revision surgery. The implant, however, was not found in the submuscular pocket and no definite chest wall defect was found in the operative field. The doctor suspected implant migration into the pleural cavity, and after inserting a new breast implant, the doctor referred the patient to our hospital for further evaluation. The patient's vital signs were stable and she showed no specific symptoms except mild, intermittent pain in the left chest. A CT scan revealed the ruptured implant in the left pleural cavity and passive atelectasis. Results: The intrapleurally migrated ruptured implant was removed by video-assisted thoracic surgery (VATS). There were no adhesions but there was mild inflammation of the pleura. No definite laceration of the pleura was found. The patient was discharged on the first day after the operation without any complications. Conclusion: Surgeons should be aware that breast implants can rupture anytime and the injury to the chest wall, which may displace the breast implant into the pleural cavity, can happen during submuscular pocket dissection and implant insertion.

식염수 보형물을 이용한 즉시 유방 재건술: AlloDerm®을 이용한 대흉근 피복의 확장 (Immediate Breast Reconstruction using saline implant: Extension of pectoralis major muscle coverage with AlloDerm®)

  • 황창헌;김은기;엄진섭;안세현;손병호;김태곤;이택종
    • Archives of Plastic Surgery
    • /
    • 제36권2호
    • /
    • pp.161-166
    • /
    • 2009
  • Purpose: Using the implant for the breast reconstruction still remains the options, despite the breast reconstruction using autologous tissue is an ideal method. In this study, we used AlloDerm$^{(R)}$ to extend subpectoral pocket for covering implants to reduce implant related complications. Met hods : From January 2005 to June 2007, 18 breasts in 16 patients were reconstructed using implant and AlloDerm$^{(R)}$ immediately after mastectomy. Hospital records, database files, and clinical photographs were reviewed. A ten - point scale was used to evaluate the patient's satisfaction, with a range from 2(poor) to 10(excellent). Results: Mean age of the patients was 38.7 years at the time of operation. Mean weight of removed breast tissue was 287g. AlloDerm$^{(R)}$ was used to extend subpectoral coverage. Any systemic complication was not reported. Breast complication was developed in 4 cases. Implant removal or change was not experienced. Conclusion: Immediate breast reconstruction using Implant is useful methods for certain conditions, when donor tissue is insufficient and breast is non ptotic with round shape. In those cases, extension of muscle coverage using AlloDerm$^{(R)}$ could reduce complications and lead more acceptable results.

내시경을 이용한 겨드랑절개 이중평면 유방확대술 (Endoscopic Transaxillary Dual Plane Breast Augmentation)

  • 심형보;위형곤;홍윤기
    • Archives of Plastic Surgery
    • /
    • 제35권5호
    • /
    • pp.545-552
    • /
    • 2008
  • Purpose: The transaxillary approach for breast augmentation has been advocated for patients and surgeons for several decades. However, this blind technique had many disadvantages including, traumatic dissection, difficult hemostasis, displacement of implants, and ill-defined asymmetrical location of inframammary crease. In the present study, the precise endoscopic electrocautery dissection was applied to eliminate the limits of blunt dissection throughout the procedures. Methods: From December 2006 to December 2007, a total of 103 patients with an average age of 29.5 years underwent endoscopic assisted transaxillary dual plane augmentation mammoplasty. The mean implant size was 243 cc with the range between 150 and 350 cc. Through a 4 cm axillary incision, electrocautery dissection for submuscular pockets was carried out under the endoscopic control. The costal origin of pectoralis muscle was completely divided to expose subcutaneous tissue and to make type I dual plane. Results: Using the endoscopic dissection, we achieved good aesthetic results including a short recovery period, less morbidity, and symmetrical well-defined inframammary crease. Type I dual plane procedure could support the consistent inframammary fold shape and be applied to most patients without breast ptosis. Minor complications did not occur, however, four major complications of capsular contracture occurred. Conclusion: In contrast to the era of the blind techniques, endoscopic assisted transaxillary dual plane breast augmentation can now be performed effectively and reproducibly. With Its advantage, the axillary application of endoscopy for augmentation mammaplasty is useful to achieve the optimal cosmetic outcomes.

Treatment of Pseudoangiomatous Stromal Hyperplasia of the Breast: Implant-Based Reconstruction with a Vascularized Dermal Sling

  • Jung, Bok Ki;Nahm, Ji Hae;Lew, Dae Hyun;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • 제42권5호
    • /
    • pp.630-634
    • /
    • 2015
  • Pseudoangiomatous stromal hyperplasia (PASH) of the breast is a benign mesenchymal lesion with incidental histologic findings. Surgical excision is recommended as the treatment of choice for PASH, although the recurrence rates after excision range from 15% to 22%. A 46-year-old-female presented with a six-month history of bilateral breast enlargement and painful sensation mimicking inflammatory carcinoma. Imaging studies demonstrated innumerable enhancing nodules in both breasts. Due to the growth of the lesions and progressive clinical symptoms, bilateral subcutaneous mastectomy was performed. Grossly, the specimens were round and well-circumscribed, and the histologic examination revealed PASH. After mastectomy, we created a pocket with the pectoralis major muscle and a lower skin flap, which was deepithelized. Anatomical mammary implants were inserted, and the nipple areolar complex was transferred to a new position as a free graft. The aesthetic result was satisfactory after twelve months of follow-up.