• Title/Summary/Keyword: breast implants

Search Result 102, Processing Time 0.029 seconds

Single-Port Transaxillary Robot-Assisted Latissimus Dorsi Muscle Flap Reconstruction for Poland Syndrome: Concomitant Application of Robotic System to Contralateral Augmentation Mammoplasty

  • Hwang, Yong-Jae;Chung, Jae-Ho;Lee, Hyung-Chul;Park, Seung-Ha;Yoon, Eul-Sik
    • Archives of Plastic Surgery
    • /
    • v.49 no.3
    • /
    • pp.373-377
    • /
    • 2022
  • Currently, robot-assisted latissimus dorsi muscle flap (RLDF) surgery is used in treating patients with Poland syndrome and for breast reconstruction. However, conventional RLDF surgery has several inherent issues. We resolved the existing problems of the conventional system by introducing the da Vinci single-port system in patients with Poland syndrome. Overall, three patients underwent RLDF surgery using the da Vinci single-port system with gas insufflation. In the female patient, after performing RLDF with silicone implant, augmentation mammoplasty was also performed on the contralateral side. Both surgeries were performed as single-port robotic-assisted surgery through the transaxillary approach. The mean operating time was 449 (335-480) minutes; 8.67 (4-14) minutes were required for docking and 59 (52-67) minutes for robotic dissection and LD harvesting. No patients had perioperative complication and postoperative problems related to gas inflation. The single-port robot-assisted surgical system overcomes the drawbacks of previous robotic surgery in patients with Poland syndrome, significantly shortens the procedure time of robotic surgery, has superior cosmetic outcomes in a surgical scar, and improves the operator's convenience. Furthermore, concurrent application to another surgery demonstrates the possibility in the broad application of the robotic single-port surgical system.

A Study on the Image Change Using Twinkle Artifact Images and Phantom according to Calcification-Inducing Environment in Breast Ultrasonography (유방 초음파 검사에서 석회화 유발 환경에 따른 반짝 허상과 팸텀을 활용한 영상 변화에 관한 연구)

  • Cheol-Min Jeon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.751-759
    • /
    • 2023
  • Breast ultrasonography is difficult to image in fatty breasts and to find micro-calcification, but the discovery of micro-calcification is very important for breast cancer screening. Among the color Doppler artifact of ultrasound, twinkle artifact mainly occur on strong reflectors such as stones or calcification in images, and evaluation methods using them are clinically being used. In this study, we are conducting experiments on the color Doppler settings of ultrasound equipment, such as repetition frequency, ensemble, persist, wall filtering, smoothing, linear density, and dissociation value, by producing a breast simulation phantom using the largest amount of calcium phosphate among breast implants. The purpose of this study was to improve the contrast of twinkle artifact in breast ultrasound examinations and to maximize their use in clinical practice. As a result, the pulse repetition frequency occurred in the range of 3.6 kHz to 7.2 kHz, and did not occur above 10.5 kHz. For ensembles, twinkle artifact occurred in all sizes of calcification under low conditions, and in threshold settings, the twinkle artifact increased slightly only under 80 to 100 conditions, and did not occur in 1 mm size calcification. Persist, wall filter, smoothing, and line density settings did not have much meaning in the setting variable because conditions did not increase by condition, and pulse repetition frequency, ensemble, and thresholds had the greatest impact on the twinkling artifact image. This study is expected to help examiners select optimal conditions to effectively increase twinkle artifact by adjusting color Doppler settings.

The management of breast implant-associated anaplastic large cell lymphoma in the setting of pregnancy: seeking for clinical practice guidelines

  • Elia, Rossella;Maruccia, Michele;De Pascale, Aurelia;Di Napoli, Arianna;Ingravallo, Giuseppe;Giudice, Giuseppe
    • Archives of Plastic Surgery
    • /
    • v.48 no.4
    • /
    • pp.373-377
    • /
    • 2021
  • Breast implant-associated anaplastic large cell lymphoma (BIA-ALCL) is a recently described form of T-cell non-Hodgkin lymphoma now formally recognized by the World Health Organization classification of lymphoid neoplasms. The aim of this paper is to report the first case of BIA-ALCL diagnosed in a pregnant patient. It is well known that BIA-ALCL appears as an indolent lymphoma with a good prognosis when diag-nosed at early stages and clinical guidelines for its management have been clearly published. Nevertheless, they lack a standardized approach for BIA-ALCL during pregnancy. With limited experience in our case, treatment has been safely postponed after term without affecting patient's overall prognosis and without fetal complication. The fact that the disease was diagnosed at an early stage (stage I) undoubtedly influenced the course of treatment. A multidisciplinary approach weighing the risks and benefits of treatment is of paramount importance in order to ensure the best possible outcome for both the mother and her child and clinical update guidelines should be issued.

Surgical Treatment of Postpneumonectomy Syndrome with Tissue Expanders in Children

  • Jung, Hee Suk;Suh, Jee Won;Kim, Tae Hoon;Lee, Chang Young;Chung, Kyung Young
    • Journal of Chest Surgery
    • /
    • v.48 no.3
    • /
    • pp.217-219
    • /
    • 2015
  • Postpneumonectomy syndrome (PPS) is a rare late complication of pneumonectomy. It occurs more often in children than in adults, and is characterized by respiratory failure resulting from bronchial compression caused by severe mediastinal shift. Various methods have been used to treat PPS, including aortopexy and the insertion of plastic balls, silastic implants, and saline-filled breast prostheses. We describe two cases of PPS corrected with tissue expanders after right pneumonectomy in patients with esophageal atresia.

Postmastectomy Breast Reconstruction is Safe in Patients on Chronic Anticoagulation

  • Yan, Maria;Kuruoglu, Doga;Boughey, Judy C.;Manrique, Oscar J.;Tran, Nho V.;Harless, Christin A.;Martinez-Jorge, Jorys;Nguyen, Minh-Doan T.
    • Archives of Plastic Surgery
    • /
    • v.49 no.3
    • /
    • pp.346-351
    • /
    • 2022
  • Background Postmastectomy breast reconstruction (PMR) increases patient satisfaction, quality of life, and psychosocial well-being. There is scarce data regarding the safety of PMR in chronic anticoagulated patients. Perioperative complications can reduce patient satisfaction; therefore, it is important to elucidate the safety of PMR in these patients. Methods A retrospective case-control study of patients who underwent PMR with implants and were on chronic anticoagulation was performed at our institution. Inclusion criteria were women ≥ 18 years old. Exclusion criteria included autologous reconstructions, lumpectomy, and oncoplastic procedures. Two controls for every one patient on anticoagulation were matched by age, body mass index, radiotherapy, smoking history, type of reconstruction, time of reconstruction, and laterality. Results From 2009 to 2020, 37 breasts (20 patients) underwent PMR with implant-based reconstruction and were on chronic anticoagulation. A total of 74 breasts (40 patients) who had similar demographic characteristics to the cases were defined as the control group. Mean age for the case group was 53.6 years (standard deviation [SD] = 16.1), mean body mass index was 28.6 kg/m2 (SD = 5.1), and 2.7% of breasts had radiotherapy before reconstruction and 5.4% after reconstruction. Nine patients were on long-term warfarin, six on apixaban, three on rivaroxaban, one on low-molecular-weight heparin, and one on dabigatran. The indications for anticoagulation were prior thromboembolic events in 50%. Anticoagulated patients had a higher risk of capsular contracture (10.8% vs. 0%, p = 0.005). There were no differences regarding incidence of hematoma (2.7% vs. 1.4%, p = 0.63), thromboembolism (5% vs. 0%, p = 0.16), reconstructive-related complications, or length of hospitalization (1.6 days [SD = 24.2] vs. 1.4 days [SD = 24.2], p = 0.85). Conclusion Postmastectomy implant-based breast reconstruction can be safely performed in patients on chronic anticoagulation with appropriate perioperative management of anticoagulation. This information can be useful for preoperative counseling on these patients.

Fifty Years of Innovation in Plastic Surgery

  • Kwasnicki, Richard M;Hughes-Hallett, Archie;Marcus, Hani J;Yang, Guang-Zhong;Darzi, Ara;Hettiaratchy, Shehan
    • Archives of Plastic Surgery
    • /
    • v.43 no.2
    • /
    • pp.145-152
    • /
    • 2016
  • Background Innovation has molded the current landscape of plastic surgery. However, documentation of this process only exists scattered throughout the literature as individual articles. The few attempts made to profile innovation in plastic surgery have been narrative, and therefore qualitative and inherently biased. Through the implementation of a novel innovation metric, this work aims to identify and characterise the most prevalent innovations in plastic surgery over the last 50 years. Methods Patents and publications related to plastic surgery (1960 to 2010) were retrieved from patent and MEDLINE databases, respectively. The most active patent codes were identified and grouped into technology areas, which were subsequently plotted graphically against publication data. Expert-derived technologies outside of the top performing patents areas were additionally explored. Results Between 1960 and 2010, 4,651 patents and 43,118 publications related to plastic surgery were identified. The most active patent codes were grouped under reconstructive prostheses, implants, instruments, non-invasive techniques, and tissue engineering. Of these areas and other expert-derived technologies, those currently undergoing growth include surgical instruments, implants, non-invasive practices, transplantation and breast surgery. Innovations related to microvascular surgery, liposuction, tissue engineering, lasers and prostheses have all plateaued. Conclusions The application of a novel metric for evaluating innovation quantitatively outlines the natural history of technologies fundamental to the evolution of plastic surgery. Analysis of current innovation trends provides some insight into which technology domains are the most active.

Impact of the human body in wireless propagation of medical implants for tumor detection

  • Morocho-Cayamcela, Manuel Eugenio;Kim, Myung-Sik;Lim, Wansu
    • Journal of Internet Computing and Services
    • /
    • v.21 no.2
    • /
    • pp.19-26
    • /
    • 2020
  • This paper analyses the feasibility of using implantable antennas to detect and monitor tumors. We analyze this setting according to the wireless propagation loss and signal fading produced by human bodies and their environment in an indoor scenario. The study is based on the ITU-R propagation recommendations and prediction models for the planning of indoor radio communication systems and radio local area networks in the frequency range of 300 MHz to 100 GHz. We conduct primary estimations on 915 MHz and 2.4 GHz operating frequencies. The path loss presented in most short-range wireless implant devices does not take into account the human body as a channel itself, which causes additional losses to wireless designs. In this paper, we examine the propagation through the human body, including losses taken from bones, muscles, fat, and clothes, which results in a more accurate characterization and estimation of the channel. The results obtained from our simulation indicates a variation of the return loss of the spiral antenna when a tumor is located near the implant. This knowledge can be applied in medical detection, and monitoring of early tumors, by analyzing the electromagnetic field behavior of the implant. The tumor was modeled under CST Microwave Studio, using Wisconsin Diagnosis Breast Cancer Dataset. Features like the radius, texture, perimeter, area, and smoothness of the tumor are included along with their label data to determine whether the external shape has malignant or benign physiognomies. An explanation of the feasibility of the system deployment and technical recommendations to avoid interference is also described.

Immediate breast reconstruction following nipple-sparing mastectomy in an Asian population: Aesthetic outcomes and mitigating nipple-areolar complex necrosis

  • Pek, Wan-Sze;Tan, Bien-Keem;Ng, Yvonne Ying Ru;Tan, Veronique Kiak Mien;Rasheed, Mohamed Zulfikar;Tan, Benita Kiat Tee;Ong, Kong Wee;Ong, Yee Siang
    • Archives of Plastic Surgery
    • /
    • v.45 no.3
    • /
    • pp.229-238
    • /
    • 2018
  • Background Nipple-sparing mastectomies (NSMs) are increasingly performed to obtain the best aesthetic and psychological outcomes in breast cancer treatment. However, merely preserving the nipple-areolar complex (NAC) does not guarantee a good outcome. Darkly pigmented NACs and a tendency for poor scarring outcomes are particular challenges when treating Asian patients. Herein, we review the reconstructive outcomes following NSM at Singapore General Hospital. Methods All breasts reconstructed following NSM over an 11-year period from 2005 to 2015 were reviewed. Information was collected from the patients' records on mastectomy indications, operative details, and complications. Patient satisfaction, breast sensation, and aesthetic outcomes were evaluated in 15 patients. Sensation was quantified using the Semmes-Weinstein monofilament test. Results A total of 142 NSMs were performed in 133 patients for breast cancer (n=122, 85.9%) or risk reduction (n=20, 14.1%). Of the procedures, 114 (80.2%) were autologous reconstructions, while 27 (19.0%) were reconstructions with implants. Complications occurred in 28 breasts (19.7%), with the most common complication being NAC necrosis, which occurred in 17 breasts (12.0%). Four breasts (2.8%) had total NAC necrosis. The overall mean patient satisfaction score was 3.0 (good). The sensation scores were significantly diminished in the skin envelope, areola, and nipple of breasts that had undergone NSM compared to non-operated breasts (P<0.05). Half of the subset of 15 patients in whom aesthetic outcomes were evaluated had reduced nipple projection. Conclusions Immediate reconstruction after NSM was performed with a low complication rate in this series, predominantly through autologous reconstruction. Patients should be informed of potential drawbacks, including NAC necrosis, reduced nipple projection, and diminished sensation.

The efficacy of ultrasound-guided erector spinae plane block after mastectomy and immediate breast reconstruction with a tissue expander: a randomized clinical trial

  • Park, Sukhee;Park, Joohyun;Choi, Ji Won;Bang, Yu Jeong;Oh, Eun Jung;Park, Jiyeon;Hong, Kwan Young;Sim, Woo Seog
    • The Korean Journal of Pain
    • /
    • v.34 no.1
    • /
    • pp.106-113
    • /
    • 2021
  • Background: We aimed to investigate the analgesic efficacy of an erector spinae plane block (ESPB) in immediate breast reconstruction (IBR) with a tissue expander. Methods: Adult women undergoing IBR with a tissue expander after mastectomy were randomly assigned to either intravenous patient-controlled analgesia (IV-PCA) alone (group P) or IV-PCA plus ESPB (group E). The primary outcome was the total amount of opioid consumption during 24 hours postoperatively between the two groups. Secondary outcomes were patient satisfaction, pain score at rest and on shoulder movement using numerical rating scale, incidences of postoperative nausea and vomiting (PONV), and a short form of the brief pain inventory (BPI-SF) at 3 and 6 months after surgery between the groups. Results: Fifty eight patients completed the study. At 24 hours postoperatively, total opioid consumption was significantly less in group E than in group P (285.0 ± 92.0, 95% confidence interval [CI]: 250.1 to 320.0 vs. 223.2 ± 83.4, 95% CI: 191.5 to 254.9, P = 0.005). Intraoperative and cumulative PCA fentanyl consumption at 3, 6, 9, and 24 hours were also less in group E than in group P (P = 0.004, P = 0.048, P = 0.020, P = 0.036, and P < 0.001, respectively). Patient satisfaction was higher in group E (6.9 ± 1.8 vs. 7.8 ± 1.4, P = 0.042). The incidences of PONV was similar. Conclusions: The ESPB decreased postoperative opioid consumption and increased patient satisfaction without significant complications after IBR with a tissue expander after mastectomy.

Simultaneous Nuss Operation and Mammoplasty in an Adult Patient with Pectus Excavatum - A case report - (성인 여자 오목가슴 환자에서 유방 확대술과 동시에 시행한 너스 수술 - 1예 보고 -)

  • Kim, Kyung-Soo;Cho, Deog-Gon;Cho, Kyu-Do;Jo, Min-Seop;Kang, Chul-Ung
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.523-526
    • /
    • 2008
  • Minimally Invasive repair of pectus excavatum using a metal bar, as advocated by Nuss, has been broadly accepted recently for its aesthetic aspect. There are and various treatment methods, as welt. Pectus excavatum may be accompaniedso many modified repair methods have been developed and performed. We report a case of a 33-year-old woman with pectus excavatum and breast hypoplasia, which were simultaneously corrected using a substernal steel bar and mammoplasty.