• Title/Summary/Keyword: breast examination

Search Result 425, Processing Time 0.022 seconds

Disseminated Postnatal Cytomegalovirus Infection in a Preterm Neonate: Autopsy Case Report

  • Kim, Ka-Young;Kim, Ee-Kyung;Park, Sung-Hye;Kim, Yoo Jinie;Shin, Seung-Han;Kim, Han-Suk
    • Neonatal Medicine
    • /
    • v.28 no.2
    • /
    • pp.83-88
    • /
    • 2021
  • Treatment guidelines for postnatal cytomegalovirus (pCMV) infection in preterm have not been established yet. Neutropenia, thrombocytopenia, hepatitis, colitis, and sepsis-like disease are among the clinical manifestations, which range from moderate to serious. We present a case of autopsy diagnosed as pCMV infection in a premature infant delivered at gestational age of 24 weeks and 5 days. On the 7th and 14th days of birth, urinary CMV polymerase chain reaction samples were negative, ruling out congenital CMV infection. However, autopsy examination revealed that the patient had disseminated pCMV infection. CMV inclusion bodies were found in the majority of tissues, including the lung, liver, pancreas, breast, kidney, and adrenal gland, but not the placenta. The thymus exhibited significant cortical atrophy and T-cell immunodeficiency, possibly induced by dexamethasone treatment for bronchopulmonary dysplasia or by pCMV infection itself. If dexamethasone treatment is extended or high doses are considered, it may be beneficial to test the CMV infection status to prevent aggravation of infection. This case demonstrates that, despite the low prevalence, pCMV infection should be considered a differential diagnosis in preterm if other conditions or etiology cannot justify clinical deterioration.

Correlation Analysis of Diffusion Metrics (FA and ADC) Values Derived from Diffusion Tensor Magnetic Resonance Imaging in Breast Cancer (유방암의 확산텐서 자기공명 영상에서 유도된 확산 지표(FA, ADC) 값의 연관성 분석)

  • Lee, Jae-Heun;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.755-762
    • /
    • 2018
  • The purpose of this study was to compare the FA(faractional anisotropy) and ADC(apparent diffusion coefficient) values, which were derived from diffusion tensor imaging in breast cancer patients. The diffusion gradient used in this study was derived from quantitative diffusion indices using 20 directions(b-value, 0 and $1,000s/mm^2$). Quantitative analysis was analyzed using Pearson's correction and qualitative analysis using for correction coefficients. As a result, $FA_{min}$, $FA_{mean}$ and $FA_{max}$ were $0.098{\pm}0.065$, $0.302{\pm}0.142$ and $0.634{\pm}0.236$, respectively(p > 0.05). The $ADC_{min}$, $ADC_{mean}$ and $ADC_{max}$ were $0.741{\pm}0.403$, $1.095{\pm}0.394$ and $1.530{\pm}0.447$, respectively(p > 0.05). The $FA_{min}$, $FA_{mean}$, and $FA_{max}$ mean values were $0.132{\pm}0.050$, $0.418{\pm}0.094$, and $0.770{\pm}0.164$ for Category 6 and Kinetic Curve Pattern III, respectively. $ADC_{min}$, $ADC_{mean}$, and $ADC_{max}$ were $0.753{\pm}0.189$, $1.120{\pm}0.236$, and $1.615{\pm}0.372$, respectively. Quantitative analysis showed negative correlation between $ADC_{mean}-FA_{mean}$ and $ADC_{max}-FA_{max}$(p = 0.001, 0.003). The qalitative analysis showed ADC 0.628(p = 0.001), FA 0.620(p = 0.001) in the internal evaluations, ADC 0.677(p = 0.001), FA 0.695(p = 0.001) in external evaluations. In conclusion, based on the morphological examination, time to signal intensity graph is the form of wash-out(pattern III) in the dynamic contrast enhance examination, As a result, the $ADC_{mean}$ $1.120{\pm}0.236$ and $FA_{mean}$ values were $0.032{\pm}0.142$ with a negative correlation (Y=1.44-1.12X). Therefore, If we understand the shape of time to signal intensity graph and the relationship between ADC and FA, It will be a criterion for distinguishing malignant diseases in breast cancer.

Analysis of Dietary and Health Characteristics and Disease Correlation of Adult Men Aged 40 in Areas with High Levels of Fine Dust Pollution based on the 2013-2017 Korea National Health and Nutrition Examination Survey Data (2013-2017 국민건강영양조사 자료에 근거한 미세먼지 오염도가 높은 지역의 40세 이상 성인남성의 식생활과 건강관련 특성 및 질환 상관성 분석)

  • Yu, Da-Som;Kang, Nam E;Lim, Hee-Jung;Jang, Se-Eun;Oh, Yoon Sin
    • Journal of the Korean Society of Food Culture
    • /
    • v.35 no.4
    • /
    • pp.363-370
    • /
    • 2020
  • This study analyzed the health characteristics and comorbidity of adult men aged 40 years by dividing them into a control group of those without any disease related to fine dust and a patient group with one or more diseases related to fine dust in areas with high levels of fine dust pollution using the sixth and seventh Korea National Health and Nutrition Examination Survey (2013-2017). Among the general characteristics, the mean age of the patient group was significantly older than that of the control group (p<0.001), and in terms of the health-related characteristics, the frequency of breakfast consumption in the patient group was higher than in the control group (p<0.043). The body measurements were similar in the patient and control groups. Regarding the prevalence of comorbidity, the patient group showed a higher prevalence of hypertension, dyslipidemia, stroke, myocardial infarction, heart failure, and diabetes than the control group, but the differences were not statistically significant. On the other hand, the prevalence of other cancers (except stomach cancer, liver cancer, colorectal cancer, breast cancer, and cervical cancer) in the patient group was higher than in the control group (p<0.05). In terms of the clinical characteristics, the glycated hemoglobin levels in the patient group were significantly higher than in the control group (p<0.048). Information on nutrition and health in areas with frequent occurrences of fine dust was obtained through the study results, which can be used as basic data for measures of health and diet management against diseases that will increase in relation to fine dust.

Comparative study between an intensive small group teaching and a 1-year clinical practice on OSCE

  • Kim, Sinjae;Park, Minhwan;Seo, Ji-Hyun;Woo, Hyang-Ok;Youn, Hee-Shang;Park, Jung Je;Jeon, Sea-Yuoug;Hwa, Jung Seok;Mullan, Patricia;Gruppen, Larry D.
    • Kosin Medical Journal
    • /
    • v.33 no.2
    • /
    • pp.181-190
    • /
    • 2018
  • Objectives: Our school introduced a new curriculum based on faculty-directed, intensive, small-group teaching of clinical skills in the third-year medical students. To examine its effects, we compared the mean scores on an OSCE between the third- and fourth-year medical students. Methods: Third- and fourth-year students did rotations at the same five OSCE stations. They then completed a brief self-reporting questionnaire survey to examine the degree of satisfaction with new curriculum in the third-year students and clinical practice in the fourth-year students, as well as their perception of confidence and preparedness. We analyzed the OSCE data obtained from 158 students, 133 of whom also completed the questionnaire. Results: Mean OSCE scores on the breast examination and wet smear stations were significantly higher in the third-year group (P < 0.001). But mean OSCE scores of motor-sensory examination and lumbar puncture were significantly higher in the fourth-year group (P < 0.05). The mean OSCE scores had no significant correlation with satisfaction. In addition, the self-ratings of confidence had a high degree of correlation with satisfaction with new curriculum (r = 0.673) and clinical practice (r = 0.692). Furthermore, there was a moderate degree of correlation between satisfaction and preparedness in both groups (r = 0.403 and 0.449). Conclusions: There is no significant difference in the effect on the degree of clinical performance and confidence between an intensive-small group teaching and a 1-year clinical practice. If combined, intensive small group teaching and clinical practice would be useful to improve the degree of ability and confidence in medical students.

Usefulness of $^{18}F$-FDG Fusion PET for Diagnosing an Early Stage Cancer (조기 암 진단을 위한 $^{18}F$-FDG Fusion PET의 유용성)

  • Jeon, Jae-Hwan;Kim, Byeong-Jin;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.145-149
    • /
    • 2010
  • Purpose: Recently, $^{18}F$-FDG Fusion PET which has a high sensitivity for diagnosing cancer is being used for purpose of health examination. This study is to demonstrate that $^{18}F$-FDG fusion PET study is useful for diagnosing an early stage cancer. Materials and Methods: This research has been conducted with 2790 patients visited Seoul National University Hospital Healthcare System (SNUHHS) for $^{18}F$-FDG fusion PET study for a health examination from February, 2004 to December 2008. PET/CT images were acquired from skull base to femur after 1 hour from injecting $^{18}F$-FDG 0.14 mCi/kg to the patients. GEMINI GS (Philips, Netherlands) was used for scanning. Results: From February 2004 to December 2008, $^{18}F$-FDG Fusion PET study was performed for 99,009 patients among all patients who visited SNUHHS and 2,790 patients was performed. Diagnostic rate for malignant cancer was 0.95% for the patients who were not examined by $^{18}F$-FDG Fusion PET study. 1.94% was for the patients who were. The rate of malignant tumor was showed 10% and benign tumor was 90% among 542 patients who showed abnormality in the PET/CT images. Types and rates of malignant tumor showed thyroid cancer: 31.5%, lung cancer: 14.8%, stomach cancer: 9.3%, rectum cancer: 3.7%, breast cancer: 3.7%, metastasis cancer: 16.7%. Nonspecific lymph node in the mediastinum, physiologic uptake in the colon, diffuse mild hypermetabolism in bilateral thyroid gland were shown as a benign tumor. Conclusion: The diagnostic rate of malignant tumor with $^{18}F$-FDG Fusion PET for a purpose of health examination was relatively higher than general medical examination. Consequently, it is superior and useful for applying $^{18}F$-FDG Fusion PET study for health examination.

  • PDF

The study of Breast Specific Gamma Imaging Protocol using Self-development Phantom (자체 제작된 팬텀을 적용한 Breast Specific Gamma Imaging 검사 프로토콜에 대한 고찰)

  • Lee, Hae-Jung;Lee, Juyoung;Lim, Kuen-Kyo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.39-47
    • /
    • 2014
  • Purpose As breast cancer patients continue to increase every year, cases of BSGI are on the rise with a heavier reliance on it. However, BSGI protocol in hospitals was not studied enough despite it was covered by hospital's condition and recommendation of manufacturers. The objective of the study was an examination of methods to be applicable to BSGI protocols, putting the self-development phantom to use in quality assessment of the images. Materials and Methods Dilon 6800 (Dilon Technologies Inc, Newport News, USA) was used in the study and five different sizes of sphere were distinctively produced in the phantom. The study used $^{99m}TcO_4$. The cases were classified in to three categories that background radioactivity to region of interest as ratio of 2: 4: 8, They were acquired images for 5, 7, 10mins. The acquired image was set region of interest according to the size of sphere, and We analyzed quantitative and qualitative analysis. The acquired data statistically analyzed with SPSS ver.18.0. Results As the result of quantitative and qualitative analysis, count rate of each sphere in accordance with difference of injection dose showed that higher count rate as injection dose and sphere size increased (P<0.005). Count rate of each sphere in accordance with difference of acquisition time showed that higher count rate as acquisition time and sphere size increased (P<0.005). Contrast noise ratio of each sphere in accordance with difference of injection dose showed that higher contrast noise ratio as injection dose increased. Particularly, Contrast noise ratio of eight times ratio images was the highest among. Contrast noise ratio of each sphere in accordance with difference of acquisition time showed that higher contrast noise ratio as acquisition time increased. And, Contrast noise ratio of seven minute image was the highest among (P<0.005). Conclusion There was significant change of Contrast noise ratio through quantitative and qualitative analysis. Moreover, We found usefulness of phantom. If Institutions identified image through the phantom study and they made BSGI protocol, We expected to help the improvement of diagnostic value of the images.

  • PDF

Arm Morbidity after Breast Cancer Treatments and Analysis of Related Factors (유방암 환자의 상지 부작용과 관련 요인)

  • Chun Mi Son;Moon Seong Mi;Lee hye Jin;Lee Eun-Hyun;Song Yeoung Suk;Chung Yong Sik;Park Hee Bung;Kang Seung Hee
    • Radiation Oncology Journal
    • /
    • v.23 no.1
    • /
    • pp.32-42
    • /
    • 2005
  • Purpose : To evaluate the incidence of arm morbidity following breast cancer surgery including axillary dissection and to identify related factors. Materials and Methods : One hundred and fifty nine patients were studied using a self-report questionnaire and a clinical examination. Lymphedema, reduction of range of motion in shoulder joint and subjective symptoms (pain, impaired arm movement, numbness, stiffness) were evaluated. As related factors, demographic, oncologic characteristics and types of treatment were analysed. Results : The incidence of lymphedema ($\geqq$2 cm difference comparing to unaffected arm) was $6.3\%$, $10.7\%$, $22.5\%$ and $23.3\%$ at each 10 cm, 20 cm, 30 cm, and 40 cm from wrist. Reduction of range of motion in shoulder joint ($\geqq$ 20 degree difference comparing to unaffected arm) was noted In more than 1/3 patients for flexion, abduction and internal rotation. Especially the reduction of range of motion in internal rotation was severe ($>50\%$ reduction) in 1/3 patients. Approximately 50 to $60\%$ of patients complained impaired arm movement, numbness, stiffness and pain. Body mass index (BMI) was the significant risk factor for lymphedema. Conclusion : Lymphedema was present in 1/3 of patients and the common sites of edema were 30 cm 40 cm proximal from the wrist. Also most severe reduction of range of motion in shoulder joint was with internal rotation. There needs weight control for lymphedema because BMI was the significant risk factor for lymphedema. Also rehabilitation program for range of motion especially internal rotation In shoulder joint should be developed.

Effects of Change in Patient Position on Radiation Dose to Surrounding Organs During Chest Lateral Radiography with Auto Exposure Control Mode (자동노출제어장치를 적용한 흉부 측면 방사선검사 시 환자 위치 변화가 주변 장기의 선량에 미치는 영향)

  • Seung-Uk Kim;Cheong-Hwan Lim;Young-Cheol Joo;Sin-Young Yu
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.903-909
    • /
    • 2023
  • The purpose of this study is to compare and analyze the effect of changes in the patient's central position on the exposure dose and image quality of surrounding organs during a chest lateral examination using an Auto Exposure Control(AEC). The experiment was conducted on a human body phantom. A needle was attached to the lower part of the center of the coronal plane of the phantom, and a lead ruler was attached to the lower part of the detector so that the 50 cm point was located at the lower center of the AEC ion chamber. The exposure conditions were 125 kVp, 320 mA, the distance between the source and the image receptor was 180 cm, and the exposure field size was 14 × 17 inches. Only one AEC ion chamber was used at the bottom center, and the density was set to '0' and sensitivity to 'Middle', and the central X-ray was incident vertically toward the 6th thoracic vertebra. With AEC mode applied, the 50 cm point of the needle and lead ruler were aligned and the phantom was moved 5 cm toward the stomach (F5) and 5 cm toward the back (B5), and the dose factor was analyzed by measuring ESD. The ESD of the thyroid gland according to the change in patient center position was 232.60±2.20 μGy for Center, 231.22±1.53 μGy for F5, and 184.37±1.19 μGy for B5, and the ESD of the breast was 288.54±3.03 μGy for Center, F5 was 260.97±1.93 μGy, B5 was 229.80±1.62 μGy, and the ESD of the center of the lung was 337.02±3.25 μGy for Center, F5 was 336.09±2.29 μGy, and B5 was 261.76±1.68 μGy. As a result of comparing the average values of dose factors between each group, the difference in average values was statistically significant (p<0.01), and each group appeared to be independent. As a result of the study, there was no significant difference in the dose to the thyroid, breast, and center of the lung according to the change in the patient's central position, except for the breast (10%) when the patient moved forward about 5 cm. However, movement of about 5 cm posteriorly resulted in an average dose reduction of 23.7%. Additionally, when the patient's central position was moved to the rear, image quality deteriorated.

The Usability Evaluation of the Usefulness of Bismuth Shields in PET/CT Examination (PET/CT 검사에서 비스무스(bismuth) 차폐체의 적용에 따른 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Ji-Hyeon;Nam, Kun-Sik;Lyu, Kwang-Yeul;Lee, Tae Soo
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.49-56
    • /
    • 2014
  • Recently with CT developed, various studies for reduction of exposure dose is underway. Study of bismuth shields in these studies is actively underway, and has already been applied in the clinical. However, the application of the PET/CT examination was not activated. Therefore, through this study, depending on the application of bismuth shields in the PET/CT examination, we identify the quality of the image and the impact on the Standard Uptake Value (SUV). In this study, to apply to the shielding of the breast, by using the bismuth shields that contains 0.06 mm Pb ingredients, was applied to the PET/CT GEMINI TF 64 (Philips Healthcare, Cleveland, USA). Phantom experiments using the NEMA IEC Body Phantom, images were acquired according to the presence or absence of bismuth shields apply. Also, When applying, images were obtained by varying the spacing 0, 1, 2 cm each image set to the interest range in the depth of the phantom by using EBW-NM ver.1.0. When image of the PET Emission acquires, the SUV was in increased depending on the use of bismuth shields, difference in the depth to the surface from deep in the phantom increasingly SUV increased (P<0.005). Also, when using shields, as the more gab decreased, SUV is more increased (P<0.005). Through this study, PET/CT examination by using of bismuth shields which is used as purpose of reduction dose. When using shields, the difference of SUV resulting from the application of bismuth shields exist and that difference when gab is decrease and surface is wider. Therefore, setting spacing of shield should be considered, if considering the reduction of the variation of SUV and image quality, disease of deep organs should be a priority rather than superficial organ disease. Use of bismuth shielding factor considering the standard clinical examination, decrease unnecessary exposure can be expected to be considered.

The Usability Evaluation According to the Application of Bismuth Shields in PET/CT Examination (PET/CT 검사에서 비스무스(bismuth) 차폐체의 적용에 따른 유용성 평가)

  • Nam-Kung, Sik;Kim, Ji Hyeon;Lee, Ju young;Park, Hoon Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.36-42
    • /
    • 2013
  • Purpose: Recently with CT developed, various studies for reduction of exposure dose is underway. Study of bismuth shields in these studies is actively underway, and has already been applied in the clinical. However, the application of the PET/CT examination was not activated. Therefore, through this study, depending on the application of bismuth shields in the PET/CT examination, we want to identify the quality of the image and the impact on the SUV. Materials and Methods: In this study, to apply to the shielding of the breast, by using the bismuth shields that contains 0.06 mmPb ingredients, was applied to the PET/CT GEMINI TF 64 (Philips Healthcare, Cleveland, USA). Phantom experiments using the NEMA IEC Body Phantom, images were acquired according to the presence or absence of bismuth shields apply. Also, When applying, images were obtained by varying the spacing 0, 1, 2 cm each image set to the interest range in the depth of the phantom by using EBW-NM ver.1.0. Results: When image of the PET Emission acquires, the SUV was in increased depending on the use of bismuth shields, difference in the depth to the surface from deep in the phantom increasingly SUV increased (P<0.005). Also, when using shields, as the more gab decreased, SUV is more increased (P<0.005). Conclusion: Through this study, PET/CT examination by using of bismuth shields which is used as purpose of reduction dose be considered. When using shields, the difference of SUV resulting from the application of bismuth shields exist and that difference is more decreased as gab of shields and surface is wider. Therefore, setting spacing of shield should be considered, if considering the reduction of the variation of SUV and image quality, disease of deep or other organs should be a priority rather than superficial disease. Through this study, when applying identified to clinical examination, the reduction of unnecessary exposure is considered.

  • PDF