The study of short-circuit breaking characteristics of high-voltage alternating current switch-fuse combinations (교류 스위치-퓨우즈 조합기기의 차단특성에 관한 고찰)

  • Roh Chang-il;La Dae-Ryeol;Kim Sun-Koo;Jung Heung-Soo;Kim Won-Man;Lee Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.836-838
    • /
    • 2004
  • Alternating current switch-fuse combinations shall be designed so as to protect for load circuit of distribution line. this switch system shall be test on making and breaking at short-circuit current. the test dutys were performed to prove correct coordination between the switch and fuses in applied test conditions This paper describes characteristics and test method for prove to performance of alternating current switch-fuse combinations.

  • PDF

Manufacturing and Characteristics Analysis of a Testing Device for the Evaluation of a Distribution Board Management System (분전반 관리시스템 평가를 위한 시험 장치의 제작 및 특성 분석)

  • Ko, Wan Su;Lee, Byung Seol;Choi, Chung Seog
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.31-36
    • /
    • 2019
  • This study made a testing device to evaluate the distribution board management system. Power was supplied to the testing device using a loading-back method and the voltage applied to it was 440 V at the same turn ratio. When the human body electric shock current is 30 mA, the breaking time is set to be less than 240 ms while 30~45 mA current is flowing. The test result shows that in the case of the R-phase it was measured to be 5.19 Hz (193 ms). And the S-phase and T-phase were perfectly cut off at 5.39 Hz (186 ms) and 5.71 Hz (175 ms), respectively. When the human body electric shock current is 60mA, the breaking time is set to be less than 120 ms while 45~75 mA current is flowing. The test result shows that the R-phase, S-phase, and T-phase were accurately cut off at 8.39 Hz (11 ms), 8.87Hz (113 ms) and 9.69 Hz (103 ms), respectively. When the human body electric shock current is 90 mA, the breaking time is set to be less than 48 ms while 75 mA current is flowing. The test result shows that the R-phase, S-phase, and T-phase were accurately cut off at 19.8 Hz (50.4 ms), 16.9 Hz (59.2 ms), and 17.9 Hz (56.0 ms), respectively. That is, the developed testing device satisfied all the requirements of the distribution board evaluation criteria, and it becomes available for the performance evaluation of the distribution board management system.

Evaluation of Fluid Forces Acting on Offshore Structures Placed in the Vicinity of Underwater Shoal (수중 천퇴 인근에 설치된 해양구조물에 작용하는 유체력 결정에 대한 고찰)

  • Chun, In-Sik;Min, In-Ki;Sim, Jae-Seol
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.2
    • /
    • pp.136-145
    • /
    • 2007
  • When waves propagating over an underwater shoal break at the top of the shoal, wave heights are drastically decreased in the downstream breaking zone, but a secondary current shooting downstream with strong velocity can be induced by the breaking waves themselves. In the case that an offshore structure is placed in the breaking zone, the estimation of wave farce purely based on the visible wave height may cause an under-design of the structure. Thus, for the safe design of the structure, the breaking wave induced current should be necessarily considered in the comprehensive estimation of design load. In the present study, Boussinesq equation model to calculate the wave height distribution and breaking wave induced current was set up and applied to the scheme of a hydraulic model test previously undertaken. Based on the results of the Boussinesq model, fluid forces acting on the model structure were calculated and compared with the experimental results. The importance of the breaking wave induced current was quantitatively assessed by comparing fluid forces with or without current.

Multiple Fault Detection in Combinational Logic Networks (조합논리회로의 다중결함검출)

  • 고경식;김흥수
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.12 no.4
    • /
    • pp.21-27
    • /
    • 1975
  • In this paper, a procedure for deriving of multiple fault detection test sets is presented for fan-out reconvergent combinational logic networks. A fan-out network is decomposed into a set of fan-out free subnetworks by breaking the internal fan-out points, and the minimal detecting test sets for each subnetwork are found separately. And then, the compatible tests amonng each test set are combined maximally into composite tests to generate primary input binary vectors. The technique for generating minimal test experiments which cover all the possible faults is illustrated in detail by examples.

  • PDF

Desmutagenic Activity of Heated Mountain Herb Juices (산채류(山菜類) 가열즙(加熱汁)의 돌연변이 억제 작용에 관(關)한 연구(硏究))

  • Ham, Seung-Shi
    • Applied Biological Chemistry
    • /
    • v.31 no.1
    • /
    • pp.38-45
    • /
    • 1988
  • Potential mutagenicity of ten heated edible mountain herbs were examined with spore recassay, Ames test and DNA breaking test. Samples of edible mountain herbs were prepared with water extraction at $100^{\circ}C$ for 20 minutes. With the rec-assay, no significant mutagengic activity could be obtained from all of the samples, but among the eight of metal ions added to sample solution, $Pb^{2+}$ to R. crispus heated juice, $Zn^{2+}$ to L. fischeri and S. bracycarpa heated juice increased mutagenic activity of the samples. With the Ames test and DNA breaking test, all of the samples did not show mutagenicity. However, breaking action was activated on heated L. fischeri, P. japonicus. A. triphylla and A. tataricus juices in the presence of 25mM $Cu^{2+}$. But heated A. elata, H. aurantiaca, A. triphylla, S. bracycarpa and A. scaber juices were inactivated in the presence of 25mM $Fe^{2+}$. Desmutagenic activities against benzo$({\alpha})$pyrene significantly increased as increasing concentration of the heated edible mountain herb juices.

  • PDF

The Study on a sensitive current limiting breaking device using RF Sputtering (RF Sputtering을 이용한 전류 민감성 차단 디바이스에 관한 연구)

  • Lee, S.H.;Jeong, K.H.;Park, D.K.;Kim, Y.L.;Lee, J.C.;Koo, K.W.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1088-1092
    • /
    • 1995
  • In this paper, we evaluated the sputter-deposited Cr/Cu thin film fuses on $Al_2O_3$ substrates by the adhesive, breaking and repetitive over-current test as a function of temperature on them. Each Cr and Cu was deposited $1700{\pm}300{\AA},\;3700{\pm}300{\AA}$ using RF sputtering unit. The electroplated Cu of $25{\mu}m$ thickness was added in order to make sensitive thin film fuse of the normal current 15[A]. The adhesive strength and the number of repetition were Increasing and then decreasing with the temperature. The maximum adhesive strength of over $9kgf/9mm^2$ was obtained at $400^{\circ}C$. In the breaking test, the post-arc time characteristic was better than any other factor.

  • PDF

Failure Analysis of a Ball in the Nuclear Fuel Exchanger

  • Kim, H.P.;Kim, D.J.;Hwang, S.S.;Joung, M.K.;Lim, Y.S.;Kim, J.S.
    • Corrosion Science and Technology
    • /
    • v.4 no.5
    • /
    • pp.211-216
    • /
    • 2005
  • Failure analysis of the latch ram ball and the C-ram ball with the trade name AFBMA Gr. 50 Colmonoy No. 6, has been performed to identify the root cause of the failure. The study required the extraction of the both failed and normal balls from the nuclear fuel exchanger. Microstructures of both balls were examined after polishing and etching. Breaking tests of both the ball revealed similarity in cleavage surfaces. Fracture surfaces of both failed ball and normal ball after breaking test were examined with SEM and EDX. Microstructure of the ball revealed an austenite phase with coarse Cr rich precipitate. Indented marks observed on the surface of the failed ball are believed to be produced by overloading. In the light of the afore mentioned observations and studies, the failure mechanism of the ball in nuclear fuel exchanger seem to be caused by impact or mechanical overloading on ball.

Optimum Formulation of Starch and Non-muscle Protein for Alkali Surimi Gel from Jack Mackerel (전갱이의 알칼리 수리미 겔 제조를 위한 전분 및 비근육 단백질의 최적화)

  • 최종덕;최영준
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.32 no.7
    • /
    • pp.1032-1038
    • /
    • 2003
  • The two-level full factorial and mixture design were used to screen ingredient type and to investigate the effects of ingredients on properties of surimi gel from jack mackerel using measurements of breaking forces, deformation values and color. The addition of starch decreased breaking force significantly (p<0.05), but did not affect deformation. The bovine plasma protein (BPP) among non-muscle proteins increased a breaking force and deformation value. However, the dried egg white increased slightly a breaking force, and decreased greatly a deformation value. The breaking force of gel was increased, but deformation value did not change significantly (p<0.05) with adding BPP. The whiteness of gel was slightly improved with the addition of corn starch and BPP. At 78% moisture, the optimum ratios of ingredients were 89.5∼90.0% for alkali surimi, 4.6∼6.0% for corn starch and 4.3∼5.4% for BPP to obtain above 110g for a breaking force, 4.2 mm for a deformation, and 22.5 for a whiteness.

Mechanical Properties and Cross-sectional Surface Evaluation of Dental Ceramic Abutment (치과용 세라믹 임플란트 지대주의 기계적 특성 및 절단면 평가)

  • Hwang, Jun Ho;Kwon, Sung-Min;Choi, Sung Gi;Sung, Mi Ae;Lee, Kyu-Bok
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.5
    • /
    • pp.309-315
    • /
    • 2018
  • The purpose of this study is to assess the mechanical properties of the ceramic abutment with washer. In this study, ceramic abutment were used, tested with $30^{\circ}$ compression load, shear fatigue, adaptation accuracy test(rotation angle, contact interval), removal torque force test, torsional breaking force test. The $30^{\circ}$ compression load was 729 N, the shear fatigue load was 275 N, adaptation accuracy test of rotation angle was within $3^{\circ}$, contact interval within $10{\mu}m$, and removal torque force test value is $18.88N{\cdot}cm$, torsional breaking force test value is $35.52N{\cdot}cm$. Ceramic abutment with a washer fitted have sufficient mechanical strength and may be substituted for titanium abutment.

Chip breaker mechanism with double step grooves (이단홈형 칩브레이커의 메카니즘)

  • 이우영;신효철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.6
    • /
    • pp.1005-1013
    • /
    • 1987
  • For the factory automation and unmanned machine operation, it is very important to manufacture highly reliable and efficient chip breakers for optimal chip control. In this research, using the CALMA CAD/CAM SYSTEM, the manufacturing process of 3-dimensional chip breakers is established. Using the results of the cutting test of the selected chip breakers with double-step grooves, the chip breaking mechanism is schematically analysed. An expression for the chip breaking relation is derived which considers chip material behavior following LUDWIK's stress-strain curve, chip breaking criterion and the shape of chip breakers. This contains the thickness of chip, the radius of chip curl, and the mechanical properties of chip materials. It is found that the expression agrees very closely with the experimental results.