• Title/Summary/Keyword: break-down voltage

Search Result 74, Processing Time 0.029 seconds

Implementation of Dynamic Resistance Database for Weld Quality Improvement of Spot Welder (스폿용접기의 용접품질 향상을 위한 동저항 데이터 베이스 구축)

  • 조승진;김재문;원충연;최규하;김규식;목형수
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.143-148
    • /
    • 1998
  • A dynamic electrical parameter monitoring device was designed to simultaneously record the instantaneous value of voltage, current, power, and resistance during spot welding. The data obtained using this technique have been analyzed in term of the relationships of these parameters to the phenomena occuring during the formation(surface break-down, nugget formation and mechanical collapse) of spot weld. Finally, a database implementation is undertaken to develop techniques for improving weld quality of the resistance spot welder.

  • PDF

Behaviors of Decomposition products and Electrical treeing in XLPE According to Drying condition (XLPE의 가열건조에 따른 분해잔사와 전기 Tree 특성)

  • 한기만;김동욱;김영성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.05a
    • /
    • pp.108-110
    • /
    • 1994
  • Decomposition products by crosslinking reaction of PE using Dicumylperoxide(DCP) should influence on the electrical properties in XLPE. This paper studies on Behaviors of Decomposition products and Electrical Treeing ding to Drying condition. We used the Gas Chromatography for Decomposition Gases analysis FT-IR for investigating the behaviors of Decomposition products remained in XLPE Break Down Voltage Tester for Electrical Treeing measurement.

  • PDF

Electrical and mechanical properties of elastomer epoxy by addition of liquid elastomer (엘라스토머 첨가량에 의한 탄성에폭시의 기계 및 전기적 특성)

  • Kim, Eung-Kwon;Yoon, Byeong-Don;Kang, Chun-Gi;Park, Dae-Hee;Song, Joon-Tae;Lee, Kwan-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.259-260
    • /
    • 2008
  • In this paper, we fabricated elastomer epoxy specimens by added liquid elastomer to improve the mechanical and electrical properties instead of previous high-voltage epoxy materials. As increased additive contents, glass transient temperature (Tg) was continually decreased in DSC (differential scanning calorimetry). Among specimens, 15 phr sample showed the mechanical and electrical properties similar of high-voltage epoxy in modulus, break-down and arc test. From the optimized condition of elastic epoxy, we confirmed a chance of application for high-voltage materials and power electrical instruments.

  • PDF

Reduction of Heat Generation from Junction Box in 3 kW Photovoltaic Power Generation System

  • Yun, Jung-Hyun;Sun, Ki-Ju;Cheon, Min-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.1
    • /
    • pp.21-24
    • /
    • 2016
  • A junction box used in a 3 kW photovoltaic power generation system plays a role in collecting and supplying the direct current voltage produced by photovoltaic modules to an inverter. It is also used for facilitating maintenance checks and protecting the module and inverter by keeping the voltage constant. As for the junction box, using it in a parallel connection creates a difference between the setup modules. In order to compensate, an inverse voltage diode is used. But the high-power created through the solar generator can be delivered to the inverter through the inverter regularly. Therefore, a component can break down due to excess heat. And consequently short circuits and electric leakage occurs. In this study, using a junction box that enabled the bypass of high electric power, it was possible to reduce heat generation by approximately 35℃ when compared to a standard junction box.

A Study on Three Parallel Operation Control Algorithm of Thyristor Dual Converter System for Urban Railway Substation (도시 철도용 사이리스터 듀얼 컨버터 시스템의 3병렬 운전 제어 기법에 관한 연구)

  • Kim, Sung-An;Han, Sung-Woo;Cho, Yun-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.2
    • /
    • pp.459-467
    • /
    • 2017
  • An urban railway power substation consists of three thyristor dual converters. Two converters are connected to up and down trolley line to supply the electric energy or feed the regenerative energy back to the distribution. When the two converters break down, the remaining converter is used in an emergency. One thyristor dual converter system (TDCS) manages the energy of two or three railway stations. If the TDCS fails, the trains stop operating. To solve the problem, this paper proposes the three parallel operation control algorithm of thyristor dual converter system using the emergency converter. The broken TDCS can be replaced by the emergency converter in other TDCS. The effectiveness of this proposed control is verified by simulation.

Dynamic Characteristics Improvement of a Step-Down Chopper Using Load Current Feed-Forward Compensator (부하전류 전향보상기를 이용한 강압쵸퍼의 동특성 항상)

  • Chun, Ji-Young;Jeon, Kee-Young;Chung, Chun-Byung;Han, Kyung-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.29-35
    • /
    • 2008
  • In this paper, The author present a load current feed-forward compensator by method that improve voltage controller of Step-down Chopper to get stable output voltage to sudden change of load current. To confirm the characteristics of a presented load current feed-forward compensator compared each transfer function of whole system that load current feed-forward compensator is added with transfer function of whole system that existent voltage controller is included using Mason gains formula in Root locus and Bode diagram. As a result the pole of system is improved, extreme point of the wave and system improves, and size of peak value and phase margin of break frequency in resonance frequency confirmed that is good. Therefore, presented control technique could confirm that reduce influence by perturbation and improves stationary state and dynamic characteristics in output of Step-down Chopper.

A Study on the cause and permanent measures on trouble of the GCB for the Main Tr. of Voltage, 154kV (154kV 주변압기용 가스차단기(GCB) 소손에 따른 원인규명과 항구대책 분석)

  • Jeon, Kyu-Nam;Chang, Moon-Soung;Ock, Gwang-Seok;NamGoong, Hyuk;Ahn, Joo-Hoon;Jeong, Jae-Won
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.285-286
    • /
    • 2008
  • The Gas Circuit Breaker for the Main Transformer of voltage, 154kV at the ist Hapcheon hydraulic power station, break down by the falling of a thunderbolt from now, let's improve the efficiency on the maintenance of generating equipment by studying about the cause and the method for this problem.

  • PDF

Electrical Properties according to Moisture Absorption of Elastomer Epoxy Resin (탄성형 에폭시의 흡습에 따른 전기적인 특성)

  • Park, Jae-Yeol;Park, Sung-Hee;Lee, Kang-Won;Kang, Seong-Hwa;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1155-1158
    • /
    • 2003
  • In this paper, we studied on the electrical characteristics of insulation material of elastomer epoxy. As the results of test, properties of epoxy represent differently according to elastomer contents. Also, its permittivity, tan ${\delta}$ and BDV(Break-Down Voltage) strength show big difference when those compare before moisture absorption test and after moisture absorption test. From this test we find results that mush elastomer contents can cause insulation properties to degrade.

  • PDF

A Study on Railway Electric Traction Protection System (전철용 보호계전기 시스템에 관한 연구)

  • Lee, Hee-Yong;Kim, Wang-Gon;Lee, Jong-Woo
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1390-1395
    • /
    • 2004
  • Recently, the load increasement and new regenerative systems of electrified railway system make it a difficult to distinguish between the load current and fault current. The failure of traction system perhaps causes over-current to flow. The high current can collapse other railway systems. If failures of the traction system takes place, the failures are detected and protected lest it should provoke high current flow. The over current from such a traction system failure permit to charge high tension voltage and produces high temperature arc, voltage instability, current cutting, and break down railway systems. The traction system failures detect and the system has to immediately cut off from over-current flow. To isolate the failure, the system can distinguish failure current from current flows. It forces us to adapt such as a new intelligent protection system. The protective system in traction system play a role of detecting and isolating failure points. In this paper, we proposed intelligent algorithm for discriminating normal and abnormal situation instead of the system being operated abnormally.

  • PDF