• Title/Summary/Keyword: brain structure

Search Result 412, Processing Time 0.028 seconds

A.C. Impedance Properties of HA/Ti Compound Layer coated Ti-30Ta-(3~15)Nb Alloys (Ti-30Ta-(3~15)Nb 합금에 HA/Ti 복합 코팅한 표면의 교류임피던스 특성)

  • Jeong, Y.H.;Lee, H.J.;Moong, Y.P;Park, G.H.;Jang, S.H.;Son, M.K.;Choe, H.C.
    • Journal of the Korean institute of surface engineering
    • /
    • v.41 no.5
    • /
    • pp.181-188
    • /
    • 2008
  • A.C. impedance properties of HA/Ti compound layer coated Ti-30Ta-($3{\sim}15$)Nb alloys have been studied by electrochemical method. Ti-30Ta binary alloys contained 3, 7, 10 and 15 wt% Nb were manufactured by the vacuum furnace system. And then specimen was homogenized at $1000^{\circ}C$ for 24 hrs. The sample was cut and polished for corrosion test and coating. It was coated with HA/Ti compound layer by magnetron sputter. The non-coated and coated morphology of Ti alloy were analyzed by X-ray diffractometer (XRD), energy X-ray dispersive spectroscopy (EDX) and filed emission scanning electron microscope (FE-SEM). The corrosion behaviors were investigated using A.C. impedance test (PARSTAT 2273, USA) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. Ti-30Ta-($3{\sim}15\;wt%$)Nb alloys showed the ${\alpha}+{\beta}$ phase, and $\beta$ phase peak was predominantly appeared in the case of increasingly Nb contents. The microstructures of Ti alloy were transformed from needle-like structure to equiaxed structure as Nb content increased. From the analysis of coating surface, HA/Ti composite surface uniformed coating layer with 750 nm thickness. The growth directions of film were (211), (112), (300) and (202) for HA/Ti composite coating on the surface after heat treatment at $550^{\circ}C$, whereas, the growth direction of film was (110) for Ti coating. The polarization resistance ($R_p$) of HA/Ti composite coated Ti-alloys were higher than those of the Ti and HA coated samples in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. Especially, corrosion resistance of Ti-Ta-Nb system increased as Nb content increased.

High-Resolution MRI Study on Mouse Brain Using Micro-Imaging (초고해상도 미세영상 기법을 이용한 Mouse 뇌의 자기공명영상 연구)

  • Han, Doug-Young;Yoon, Moon-Hyun;Choe, Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.142-147
    • /
    • 2008
  • Purpose : By using the micro-imaging unit modified from NMR spectrometer, the high resolution MRI protocols of finer than 100 micron in 5 minutes, is sought for mouse, which plays a central role in animal studies Materials and Methods : C57BL/6 mouse, lighter than 50 gram, is used for the experiments. The superconducting magnet is vertical type with 89 mm inner diameter at 4.9 Tesla. The diameter of rf-coil is 30 mm. Mostly used techniques are the fast spin echo and the gradient echo pulse sequence. Results : For 2D images, proton density and T2 weighted images are obtained and their optimum experimental variables were sought. Minute structure of mouse brain can be recognized and 3D brain image is also obtained additionally. 3D image will be useful particularly for the dynamic contrast study using various contrast agents. Conclusion : Like the case of human and other small animals, the high resolution of mouse brain is enough to recognize the minute structure of it. Recently, similar studies are reported domestically, but it seems only a beginning stage. Due to easiness of breeding/control, mouse MRI study will soon play a vital part in brain study.

  • PDF

A Study of Changes of Inversion Time Effect on Brain Volume of Normal Volunteers (반전 시간의 변화가 정상인의 뇌 체적에 미치는 영향에 대한 고찰)

  • Kim, Ju Ho;Kim, Seong-Hu;Shin, Hwa Seon;Kim, Ji-Eun;Na, Jae Boem;Park, Kisoo;Choi, Dae Seob
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.286-293
    • /
    • 2013
  • Purpose : The objective of this study was to analyze the brain volume according to the brain image of healthy adults in the 20s taken with different inversion time (TI). Materials and Methods: Brain images of healthy adults in the 20 s were acquired using magnetization prepared rapid acquisition gradient echo (MPRAGE) pulse sequence with 1.5 mm thickness of pieces and four inversion times (1100 ms, 1000 ms, 900 ms, 800 ms). The acquired brain images were analyzed to measure the volume of white matter (WM), gray matter (GM), intracranial volume (ICV). The statistical difference according to brain volume and gender was analyzed for each TI. Results: The brain volume calculated using Freesurfer was WM$486.52{\pm}48.64cm^3$ and GM=$646.83{\pm}57.12cm^3$ in mean when adjusted by mean ICV=$1278.94{\pm}154.92cm^3$. Men's brain volume(WM, GM, ICV) was larger than women's brain volume. In the intrarater reliability test, all of the intraclass correlation coefficients were high (0.992 for WM, 0.988 for GM, and 0.997 for ICV). In the repeated measures analysis of variance, GM and ICV did not show a significant difference at each TI (GM p=0.143, ICV p=0.052), but WM showed a significant (p=0.001). In the linear structure relation analysis, all of the Pearson correlation coefficients were high. Conclusion: WM, GM, and ICV indicated high reliability and solid linear structure relations, but WM showed significant differences at each TI. The brain volume of healthy adults in the 20s could be used in comparison with that of patients for reference purposes and to predict the structural change of brain. It would be needed to conduct additional studies to examine the contract, SNR, and lesion detection ability according to variable TI.

Relationship between Alcohol Use Disorders Identification Test Fractional Anisotropy Value of Diffusion Tensor Image in Brain White Matter Region (알코올 선별 검사법(Alcohol Use Disorders Identification Test)과 뇌 백질 영역의 확산텐서 비등방도 계측 값의 관련성)

  • Lee, Chi Hyung;Kim, Gyeong Rip;Kwak, Jong Hyeok
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.575-583
    • /
    • 2022
  • Magnetic resonance diffusion tensor imaging (DTI) has revealed the disruption of brain white matter microstructure in normal aging and alcoholism undetectable with conventional structural MR imaging. we plan to analyze the FA measurements of the ROI of dangerous drinkers selected from Alcohol Use Disorders Identification Test (AUDIT) and Tract-Based Spatial Statics (TBSS) tool was used to extract FA values in the ROI from the image acquired through the pre-processing process. TBSS has a higher sensitivity of the FA value and MD value in the white matter than the brain gray matter, and has the advantage of quantitatively deriving the unlimited degree of brain nerve fibers, and more specialized in the brain white matter. We plan to analyze the fractional anisotropy (FA) measurement value for damage by selecting the center of the anatomical structure of the white matter region of the brain with high anisotropy among the brain neural networks that are particularly vulnerable to alcohol as the region of interest (ROI). In this study, we expected that alcohol causes damage to the brain white matter microstructure from FA value in various areas including both Choroid plexus. Especially, In the case of the moderate drunker, the mean value of FA in Lt, Rt. Choroid plexus was 0.2831 and 0.2872, whereas, in the case of the severe drunker, the mean value of FA was 0.1972 and 0.1936. We found that the higher the score on the AUDIT scale, the lower the FA value in ROI region of the brain white matter. Using the AUDIT scale, the guideline for the FA value of DTI can be presented, and it is possible to select a significant number of potentially severe drinkers. In other words, AUDIT was proved as useful tool in screening and discrimination of severe drunker through DTI.

A Tapered Slot Antenna with Asymmetric Corrugations for a Microwave Brain Imaging System (전자파 두뇌 영상장치용 비대칭형 Corrugated 테이퍼드 슬롯 안테나)

  • Lee, Juneseok;Park, Joongki;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.3
    • /
    • pp.348-351
    • /
    • 2013
  • Recently, a brain imaging system with microwave devices has been proposed. The brain imaging system requires a small antenna which has ultra wide band(UWB) operating frequency bandwidth(0.5~2 GHz) and non-varying boresight of antenna over the frequency band. This paper proposes asymmetric corrugations on a tapered slot antenna (TSA) so that the size of the TSA is reduced by 14 % while 10 dB return loss bandwidth is satisfied over the operating frequency band from 0.5 GHz to 2 GHz. A miniaturized TSA with symmetric corrugations shows tilted boresight whilst frequency is getting lower; however, the proposed TSA with asymmetric corrugations maintains direction of boresight for different frequencies. This enhancements make an asymmetric corrugated TSA meet the requirement of the brain imaing system.

Moleculay Cloning of the cDNA Encoding the 16 kDa Subunit of V-ATPase in Rat Brain (흰쥐 뇌에서 발현되는 16 kDa Vacuolar (H$^{+}$)-ATPase의 유전자 클로닝)

  • Shin, Song-Woo;Yoo, Min
    • Biomedical Science Letters
    • /
    • v.6 no.3
    • /
    • pp.165-170
    • /
    • 2000
  • Vacuolar (H$^{+}$)-ATPase (V-ATPase) is an intracellular protein which consists of multiple subunits. It carries out acidification by pumping protons in the cell. This enzyme has also been found in the synaptic vesicles and may play an important role in the neurotransmission. We cloned cDNA fragments encoding the 16 kDa subunit of V-ATPase from the rat brain by RT-PCR and PCR using total RNA or recombinant phage DNA as templates. They contained the full coding sequences (468 bp) and one nucleotide at 3' region turned out to be different (A to C) when compared to the liver counterpart. However, this polymorphic difference did not cause any significant change in the primary structure of the protein because both GCA and GCC code for alanine. Our study would contribute to the understanding of the function of 16 M)a V-ATPase in the brain and of the mechanisms of neurotransmission.

  • PDF

A Study on the Shielding of Orbit by 3D Printed Filament in Brain CT (Brain CT검사 시 3D프린터 필라멘트에 따른 수정체 차폐 연구)

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.101-108
    • /
    • 2021
  • The CT can accurately present the anatomical structure of an organ in the human body, and the resolution of the image is excellent. On Brain CT examination, the radiation sensitivity of the orbit is high and it is subject to many exposure effects. To reduce exposure dose of lens, this study compares change of exposure dose and shielding rate about non-shielding and shielding in a way of using two shielding materials, bismuth and tungsten. In this study, we used bismuth and tungsten filament as shielding materials made by 3D printing to measure the exposure dose according to the materials thickness and each of slices. To compare each shielding rate, 1 mm to 5 mm of two materials was measured with the head phantom fixed and the Magicmax universal dosimeter placed on the eye when the shielding material is not placed, and the shielding material is placed on it. In the 1 mm thick filament, the bismuth filament showed 26.8% and the tungsten filament showed 43.1% shielding rate. Therefore, tungsten presents much greater shielding effect than bismuth.

Identification and confirmation of 14-3-3 ζ as a novel target of ginsenosides in brain tissues

  • Chen, Feiyan;Chen, Lin;Liang, Weifeng;Zhang, Zhengguang;Li, Jiao;Zheng, Wan;Zhu, Zhu;Zhu, Jiapeng;Zhao, Yunan
    • Journal of Ginseng Research
    • /
    • v.45 no.4
    • /
    • pp.465-472
    • /
    • 2021
  • Background: Ginseng can help regulate brain excitability, promote learning and memory, and resist cerebral ischemia in the central nervous system. Ginsenosides are the major effective compounds of Ginseng, but their protein targets in the brain have not been determined. Methods: We screened proteins that interact with the main components of ginseng (ginsenosides) by affinity chromatography and identified the 14-3-3 ζ protein as a potential target of ginsenosides in brain tissues. Results: Biolayer interferometry (BLI) analysis showed that 20(S)-protopanaxadiol (PPD), a ginseng saponin metabolite, exhibited the highest direct interaction to the 14-3-3 ζ protein. Subsequently, BLI kinetics analysis and isothermal titration calorimetry (ITC) assay showed that PPD specifically bound to the 14-3-3 ζ protein. The cocrystal structure of the 14-3-3 ζ protein-PPD complex showed that the main interactions occurred between the residues R56, R127, and Y128 of the 14-3-3 ζ protein and a portion of PPD. Moreover, mutating any of the above residues resulted in a significant decrease of affinity between PPD and the 14-3-3 ζ protein. Conclusion: Our results indicate the 14-3-3 ζ protein is the target of PPD, a ginsenoside metabolite. Crystallographic and mutagenesis studies suggest a direct interaction between PPD and the 14-3-3 ζ protein. This finding can help in the development of small-molecular compounds that bind to the 14-3-3 ζ protein on the basis of the structure of dammarane-type triterpenoid.