• Title/Summary/Keyword: bracket

Search Result 786, Processing Time 0.304 seconds

Safety Evaluate of Brackets for Bare Chassis of a 30-seated Bus

  • Choi, Wan-Mug
    • International journal of advanced smart convergence
    • /
    • v.11 no.3
    • /
    • pp.215-221
    • /
    • 2022
  • In the manufacturing process of the bus treated as the commercial vehicle, after making the bare chassis which is the basic frame of the vehicle body, the part in which passengers ride is connected. In addition, the necessary parts such as the engine and transmission required for the operation of the bus are connected to the bare chassis. The element connecting the parts such as the boarding part of the passengers, the engine, the suspension and the transmission is the bracket. The device required for driving and operating the vehicle is mounted on the bare chassis using the bracket, which should ensure stability during bus operation. In this study, we were performed stress analysis to evaluate the stability of three types of brackets connecting the bare chassis of a new type of 30-seater bus in the development process and components required for driving and operation. The stress analysis should be preceded by the analysis of boundary conditions considering the loads applied to the brackets according to the material of the bracket to be analyzed and the driving type of the bus. The finite element model for structural analysis of brackets according to the driving type of the bus was used by Altair's Hypermesh 2017, and the solver used for structural analysis was Altair's Optistruct. The stress analysis was performed to present the safe and vulnerable parts of the three brackets.

Research on Architectural Technology from Late Goryeo to Early Joseon through the Examination of Bracket Tie Beam Manufacturing Techniques in Sungnyemun Gate (숭례문 장여 제작 기법을 통해 본 여말선초 건축 기술 연구)

  • Kim, Suk-Hyun
    • Journal of architectural history
    • /
    • v.33 no.1
    • /
    • pp.45-60
    • /
    • 2024
  • This study aims to examine the cutting traces remaining on the bracket tie beams of Sungnyemun gate, identifying the tools employed during the late Goryeo to early Joseon periods by specific processes, and deliberating on the timber shaping techniques utilized in advanced architectural construction during the late Goryeo to early Joseon eras. Through the research, it was confirmed that in the production of Sungnyemun Gate's bracket tie beams during the 14th to 15th centuries, both the timber splitting and ripsawing methods were used in conjunction. Moreover, the wood finishing process revealed the use of a plane. It can be inferred that the characteristics of the plane used during that time were not significantly different from those observed in the later period of the Joseon dynasty. The ripsawing and plane finishing techniques were evident in various parts of the bracket tie beams of Sungnyemun gate across the reigns of king Taejo and Sejong, indicating that the techniques involving ripsaw and plane were already prevalent in the late Goryeo period. Consequently, it can be inferred that the ripsawing and plane finishing techniques might have been applied in the construction of prominent government buildings in Hanyang(Seoul), including Gyeongbokgung Palace, and in the residences of royalty and nobility after the establishment of the Joseon dynasty.

A COMPARATIVE STUDY OF THE SHEAR BOND STRENGTH OF DIFERENT CERAMIC BRACKETS AND ADHESIVES (세라믹 브라켓과 교정용 접착제에 따른 전단 결합 강도의 비교 연구)

  • Lee, Joo-Won;Yoo, Dong-Hwan;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.27 no.2
    • /
    • pp.315-326
    • /
    • 1997
  • The purpose of this study was to evaluate the shear bond strength of three kinds of different ceramic brackets with three different bonding adhesives. 5 specimens for each combination were tested for shear bond strength using Instron and for fracture site using SENL And 3 specimens were cross-sectioned for SEM examination of bonding pattern between bracket, resin and enamel surface. The results were as follows 1. The shear bond strength of chemical curing adhesives were higher than that of light curing adhesives. 2. The shear bond strength of Starfire bracket, chemical-bonded type, was lower than that of Transcend bracket, mechanical-bonded type, and Fascination bracket, combined type. 3. Fracture site of each bracket and tooth surface was examined under a light optical stereoscopic microscope, Transcend groups were mainly at the E/R intderface. Fascination groups were mainly at the COMB interface and Starfire groups were mainly at the R/B interface.

  • PDF

The Study of the Techniques of the Xia-ang Structure in China during the Tang and Song Dynasty (중국 당(唐).송(宋) 목조건축의 하앙 결구기법 변천 연구)

  • Chang, Hun-Duck
    • Journal of architectural history
    • /
    • v.20 no.6
    • /
    • pp.115-129
    • /
    • 2011
  • The bracket sets which are supporting the weight of the roof, has to meet both requirements which are structural functions and act as an ornamental element. Therefore the bracket sets differ in many types from time and space and has done an important role in the history of architecture with many studies being presented. The first form of the bracket set has been found in the bronze table relics in zhong shan wang ling (中山王陵). Through the Eastern Han dynasty (A.D. 25-220) it became more specific in the shique (石闕) and huaxiangshi (畵像石) in the Han dynasty (206 B.C.-A.D. 220). Afterwards, as Buddhism was introduced to China, the bracket construction techniques shown in the Mogao Caves, Yungang Grottoes, and Longmen Grottoes has given much help for understanding the building techniques of wooden architecture. Especially the Xia-ang structure seen in the Mogao caves shows a vast development in wooden structure and a typical building would be the main hall of Fo Guang Shan monastery in Mt. Wutaishan from the Tang dynasty (A.D. 618-907). This accumulated techniques is inscribed in the 'Ying Zao Fa Shi (營造法式)' wooden structure designs which was published during the Northern Song dynasty (A.D. 960-1127) and many buildings were constructed following this technique after the publication. During this period, it is assumed that Baek-jae (B.C.18-A.D.660) in the Korean peninsula also used the Xia-ang technique, but there havn't been many studies on this field. In this thesis it is introducing the development of the building techniques and structural features of the Xia-ang wooden architecture during the Tang and Song dynasty.

In vitro evaluation of resistance to sliding in self-ligating and conventional bracket systems during dental alignment

  • Cordasco, Giancarlo;Giudice, Antonino Lo;Militi, Angela;Nucera, Riccardo;Triolo, Giuseppe;Matarese, Giovanni
    • The korean journal of orthodontics
    • /
    • v.42 no.4
    • /
    • pp.218-224
    • /
    • 2012
  • Objective: To investigate the resistance to sliding (RS) in self-ligating and conventional ligation bracket systems at 5 different second-order bracket angulations by using low-stiffness alignment wires in a 3-bracket experimental model and to verify the performance of the main RS components in both systems when these wires are used. Methods: Interactive self-ligating brackets with closed and open slides were used for the self-ligating (SL) and conventional ligation (CL) groups, respectively; elastomeric ligatures (1 mm inner diameter) were used in the latter system. The alignment wire used was 0.014 inch heat-activated NiTi (austenitic finish temperature set at $36^{\circ}C$ by the manufacturer). A custom-made testing machine was used to measure frictional resistance. Tests were repeated 5 times at every angulation simulated. All data were analyzed statistically. Results: The RS increased significantly with increasing angulation in both SL and CL groups (p < 0.0001). However, the RS values were significantly higher at every angulation (p < 0.0001) in the CL group. Conclusions: Despite the relevance of the binding phenomenon, ligation forces predominantly affect the RS when lowstiffness alignment wires are used.

Comparison of the bonding strengths of second- and third-generation light-emitting diode light-curing units

  • Lee, Hee-Min;Kim, Sang-Cheol;Kang, Kyung-Hwa;Chang, Na-Young
    • The korean journal of orthodontics
    • /
    • v.46 no.6
    • /
    • pp.364-371
    • /
    • 2016
  • Objective: With the introduction of third-generation light-emitting diodes (LEDs) in dental practice, it is necessary to compare their bracket-bonding effects, safety, and efficacy with those of the second-generation units. Methods: In this study, 80 extracted human premolars were randomly divided into eight groups of 10 samples each. Metal or polycrystalline ceramic brackets were bonded on the teeth using second- or third-generation LED light-curing units (LCUs), according to the manufacturers' instructions. The shear bond strengths were measured using the universal testing machine, and the adhesive remnant index (ARI) was scored by assessing the residual resin on the surfaces of debonded teeth using a scanning electron microscope. In addition, curing times were also measured. Results: The shear bond strengths in all experimental groups were higher than the acceptable clinical shear bond strengths, regardless of the curing unit used. In both LED LCU groups, all ceramic bracket groups showed significantly higher shear bond strengths than did the metal bracket groups except the plasma emulation group which showed no significant difference. When comparing units within the same bracket type, no differences in shear bond strength were observed between the second- and third-generation unit groups. Additionally, no significant differences were observed among the groups for the ARI. Conclusions: The bracket-bonding effects and ARIs of second- and third-generation LED LCUs showed few differences, and most were without statistical significance; however, the curing time was shorter for the second-generation unit.

COMPARISON OF THE FRICTIONAL RESISTANCE BETWEEN NON-ION PLATED AND TiN ION PLATED TO THE ORTHODONTIC APPLIANCE (TiN피막 처리된 교정 장치물의 마찰 저항력에 관한 비교연구)

  • Jang, Si-Ho;Kwon, Oh-Won;Kim, Kyo-Han
    • The korean journal of orthodontics
    • /
    • v.23 no.4 s.43
    • /
    • pp.671-691
    • /
    • 1993
  • To estimate the possibility in the application of TiN ion-plating to the orthodontic appliance, this study investigated frictional force and frictional coefficient between non-ionplated and TiN ion-plated to the orthodontic appliance. The obtained results were as follows : 1. For each group, the frictional force between metal bracket and arch wire in the wet condition was exhibited lower than that in the dry condition. 2. In the dry condition, the frictional force was lowest with fourth group, and it increased in the order of the 3rd, 1st, and 2nd group. Same situation happened in the wet condition. 3. Experimental results using ceramic & plastic bracket showed that group B was lower than group A, and group D was similar to group C. 4. The surface texture after experiment showed that the scratch due to a friction with bracket was observed in an arch wire of dry contition. Also the surface of bracket was rougher than before. 5. We observed that a specimen surface processed with the TiN ion plating was smoother than that of without the TiN ion plating. 6. The surface texture of a metal bracket and an arch wire in the wet condition was observed smoother than that in the dry condition. 7. In the dry condition, the friction coefficient of each specimen was very similar to each other, but in the wet condition, the friction coefficient of specimen processed with the TiN ion plating showed lower values.

  • PDF

A Study on the Stress Distribution and Stress Concentration of Pipe with Respect to Attached Shape and Method of the Bracket in a Welding Structure (브래킷 결합형식에 따른 용접 구조물의 파이프에서 발생하는 응력분포와 응력집중에 관한 연구)

  • Jeon, Hyung-Yong;Sung, Rak-Won;Han , Geun-Jo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.8
    • /
    • pp.28-37
    • /
    • 1999
  • This investigation is the result of the structural analysis by finite element method and test for considering stress distribution and stress concentration to be generated according to the change of attached shape and method of the bracket to pipe in welding structure. Generally, members that consist structures are subjected to various forces and are jointed each other with a number of bracket. In this case, circular pipe was adapted in order to weld these members easily and to study the optimal design which is used a beam with shape section as main components of the structure, According to attached shape and method, distributed stress on circular pipe is appeared so differently. This may result deeply effects with respect to thickness, material properties. So a study on attaching shape and method of bracket to circular pipe is needed. In this paper, to obtain the maximum equivalent stress or stress concentration was used experimental and F.E.M. analysis. First five parameter was defined with respect to attached a shape and method to circular pipe i.e. the variation of the attached area, the variation of the attached shape, the variation of the attached length, the variation of both directin angles, the variation of the upper angle. Afterward the experimental analysis was practiced as the variation of the both direction angel and the finite element analysis was practiced as each parameters. We can discover stress distribution and stress concentration according to the change of form of bracket. And the result can be referenced for a design of similar structure.

  • PDF

TENSILE STRENGTH OF ORTHODONTIC DIRECT BONING ADHESIVES (교정용 접착제의 인장강도)

  • Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.12 no.1
    • /
    • pp.15-20
    • /
    • 1982
  • The requirement of ideal orthodontic direct bonding adhesive should include longevity of bond, ability to withstand a variety of forces, resistance to the degrading effects of the oral environment, and ability to be easily removed without affecting the integrity of the enamel. The purpose of this study was to evaluate the adhesive properties of recently developed 3 orthodontic directbonding adhesives by testing the tensile strength. 75 premolars extracted for orthodontic treatment were used. The tensile strength was tested by Tensilon/UTM-1-10000C after 24 hours from bonding. Following results were obtained; The mean tensile strength of each product was higher than the maximum force $(29kg/cm^2)$ exerted on a bracket during orthodontic treatment. The tensile strength of Mono-Lok was statistically higher than Concise and Dyna-Bond, although there was no difference between the tensile strength of Concise and Dyna-Bond statistically. Of the filure, the combination type of failure $(68\%)$, where part of the adhesive remained on the tooth and part on the bracket was the most common type. The second type of failure $(22.7\%)$ occurred at the toothadhesive interface and the last type of failure $(9.3\%)$ occurred at the adhesive-bracket interface.

  • PDF

Bracket bonding to polymethylmethacrylate-based materials for computer-aided design/manufacture of temporary restorations: Influence of mechanical treatment and chemical treatment with universal adhesives

  • Goracci, Cecilia;Ozcan, Mutlu;Franchi, Lorenzo;Di Bello, Giuseppe;Louca, Chris;Vichi, Alessandro
    • The korean journal of orthodontics
    • /
    • v.49 no.6
    • /
    • pp.404-412
    • /
    • 2019
  • Objective: To assess shear bond strength and failure mode (Adhesive Remnant Index, ARI) of orthodontic brackets bonded to polymethylmethacrylate (PMMA) blocks for computer-aided design/manufacture (CAD/CAM) fabrication of temporary restorations, following substrate chemical or mechanical treatment. Methods: Two types of PMMA blocks were tested: $CAD-Temp^{(R)}$ (VITA) and $Telio^{(R)}$ CAD (Ivoclar-Vivadent). The substrate was roughened with 320-grit sandpaper, simulating a fine-grit diamond bur. Two universal adhesives, Scotchbond Universal Adhesive (SU) and Assure Plus (AP), and a conventional adhesive, Transbond XT Primer (XTP; control), were used in combination with Transbond XT Paste to bond the brackets. Six experimental groups were formed: (1) $CAD-Temp^{(R)}/SU$; (2) $CAD-Temp^{(R)}/AP$; (3) $CAD-Temp^{(R)}/XTP$; (4) $Telio^{(R)}$ CAD/SU; (5) $Telio^{(R)}$ CAD/AP; (6) $Telio^{(R)}$ CAD/XTP. Shear bond strength and ARI were assessed. On 1 extra block for each PMMA-based material surfaces were roughened with 180-grit sandpaper, simulating a normal/medium-grit ($100{\mu}m$) diamond bur, and brackets were bonded. Shear bond strengths and ARI scores were compared with those of groups 3, 6. Results: On $CAD-Temp^{(R)}$ significantly higher bracket bond strengths than on $Telio^{(R)}$ CAD were recorded. With XTP significantly lower levels of adhesion were reached than using SU or AP. Roughening with a coarser bur resulted in a significant increase in adhesion. Conclusions: Bracket bonding to CAD/CAM PMMA can be promoted by grinding the substrate with a normal/medium-grit bur or by coating the intact surface with universal adhesives. With appropriate pretreatments, bracket adhesion to CAD/CAM PMMA temporary restorations can be enhanced to clinically satisfactory levels.