Development of a Pelvic Phantom for Dose Verification in High Dose Rate (HDR) Brachytherapy

  • Jang, Ji-Na;Suh, Tae-Suk;Huh, Soon-Nyung;Kim, Hoi-Nam;Yoon, Sei-Chul;Lee, Hyoung-Koo;Choe, Bo-Young
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.150-153
    • /
    • 2002
  • High dose rate (HDR) brachytherapy in the treatment of cervix carcinoma has become popular, because it eliminated many of the problems with conventional brachytherapy. In order to improve clinical effectiveness with HDR brachytherapy, dose calculation algorithm, optimization procedures, and image registrations should be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom irradiated. Therefore, the humanoid phantom should be designed such that the dose distributions could be quantitatively evaluated by utilizing the dosimeters with high spatial resolution. Therefore, the small size of thermoluminescent dosimeter (TLD) chips with the dimension of 1/8" and film dosimetry with spatial resolution of <1mm used to measure the radiation dosages in the phantom. The humanoid phantom called a pelvic phantom is made of water and tissue-equivalent acrylic plates. In order to firmly hold the HDR applicators in the water phantom, the applicators are inserted into the grooves of the applicator supporters. The dose distributions around the applicators, such as Point A and B, can be measured by placing a series of TLD chips (TLD-to- TLD distance: 5mm) in three TLD holders, and placing three verification films in orthogonal planes.

  • PDF

자체 제작한 근접방사선치료용 다목적 팬텀의 유용성 평가 (Effectiveness of a Custom-made Multi Purpose Brachytherapy Phantom)

  • 장인기;이정진;김완선
    • 대한방사선치료학회지
    • /
    • 제18권2호
    • /
    • pp.119-125
    • /
    • 2006
  • 목 적: 본 연구에서는 근접치료 시 선량기준점에서 선량을 정확히 분석하고자 근접방사선치료용 다목적 팬텀(Multi Purpose Brachytherapy Phantom, MPBP)을 제작하여 그 유용성을 평가하고자 하였다. 대상 및 방법: 자체 제작된 근접방사선치료용 다목적 팬텀(MPBP)에서 다기능삽입구(Multi Function Applicator, MFA)를 이용하여 치료 시와 동일한 조건을 재현한 후 열형광선량계(TLD)를 이용하여 전산화 치료계획 장치에서 계산된 좌표와 동일한 기준점에서 선량을 측정하였다. 측정 대상은 근접방사선 치료환자 중 탄뎀(tandem)과 난형체(ovoid)를 사용한 자궁경부암 환자 4명을 대상으로 환자 당 5회씩 총 20회 A point와 B point 그리고 방광에서 선량을 측정하였다. 결 과: MPBP에서 TLD의 측정 결과는 A Point에서 측정한 환자의 상대오차가 각각 -3.2%, -0.2%, 0%, 3.8%를 보였고, B point에서는 -1.4%, -1.4%, 2.4%, 4.0%를 보였다. 그리고 방광에서는 1.3%, 2%, 5.4%, 7.15%의 상대오차를 나타내었다. 결 론: 자체 제작된 근접치료용 다목적 팬텀(MPBP)은 다기능삽입구(MFA)를 사용하여 치료 시와 동일한 조건에서 선량측정의 재현성을 이룰 수 있었고, A, B point지점과 방광의 선량을 정확히 분석할 수 있었다. 따라서 본 연구에서 제작된 근접방사선치료용 다목적 팬텀은 기준점 선량분석에 매우 유용한 것으로 판단된다.

  • PDF

반려견 팬텀에서 유방암 근접방사선치료 시 흡수선량 평가 (Evaluation Absorbed Dose During the Breast Cancer Brachytherapy in Canine Phantom)

  • 김정훈;이득희
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.523-528
    • /
    • 2020
  • 반려견의 사망원인 1위인 암 중 암컷에게서 가장 높은 발생률을 보이는 유방암을 대상으로 근접방사선치료 수행 시 모의모사를 이용한 흡수선량 측정을 바탕으로 적용성을 평가하고자 하였다. 모의모사를 위해 MCNPX 프로그램을 이용하였으며, 흡수선량 측정을 위해 소형견 크기의 수학적 팬텀을 제작 하였다. 흡수선량 측정결과 종양의 경우 192Ir에서 1.02E-12 Gy/#으로 흡수선량이 가장 높은 것으로 나타났으며, 내·외부 흡수선량에서도 동일한 경향성으로 나타났다. 따라서 반려견 유방암의 근접방사선치료 시 견종과 피폭을 고려한 적절한 선원의 선택이 고려되어야 될 것이다.

유방암의 근접치료 시 수학적 모의피폭체를 이용한 인접장기의 선량평가 (Radiation Dose Calculation using MIRD TYPE PHANTOM in the Surrounding Organs during Brachytherapy of Breast Cancer)

  • 박은태;김정훈;임인철
    • 한국방사선학회논문지
    • /
    • 제10권4호
    • /
    • pp.271-278
    • /
    • 2016
  • 본 연구는 유방암의 근접치료 시 수학적 모의피폭체를 이용하여 유방 및 인접장기의 선량을 평가하고자 하였다. 좌측 유방과 우측 유방을 선원으로 설정하여 $^{192}Ir$$^{103}Pd$ 핵종에 대한 흡수선량을 분석하였다. 그 결과 선원 장기에 대한 선량은 $^{192}Ir$$^{103}Pd$에 비해 높은 흡수선량을 보였으며, 반대측 유방의 선량도 $^{192}Ir$이 높게 나타났다. 또한 유방암의 근접치료 시 특히 유의해야 할 인접장기는 폐, 간, 심장, 반대측 유방으로 평가되었다.

고선량률 근접 방사선 치료에서 기존의 필름 방법과 CT 재구성 방법의 비교 연구 (Comparison Study of Conventional Film-based and CT-reconstruction method in HDR Brachytherapy)

  • 장지나;이형구;윤세철;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제15권2호
    • /
    • pp.63-69
    • /
    • 2004
  • 고선량률 근접치료는 저선량률 근접치료와 비교하여 짧은 시간에 많은 선량이 조사되며, 치료를 위한 최적화가 물리적 요인, 방사선 파라미터, 최적화 알고리즘 같은 여러 복잡한 요인들과 연관되어 있으므로 정확한 선량 전달을 위해서는 정확한 검증 과정을 필요로 한다. 본 연구에서는 앞선 연구에서 제작하였던 선량 검증용 팬톰의 단점을 보완하고 CT나 MRI 시스템에서도 이용할 수 있는 구조를 추가시켜 고선량률 근접 치료의 위치 및 선량 검증을 위한 새로운 자궁경부암용 팬톰을 개발하였다. 또한, 개발된 팬톰을 이용하여 고선량률 근접치료에서의 기존의 필름에 기반한 orthogonal 방법의 위치 확인에 대한 점증을 수행하였다. 위치 확인에 대한 철증은 CT 시스템에서의 좌표를 비교, 분석함으로써 수행되었다. 제작된 팬톰은 자궁경부암 환자를 대상으로 환자의 해부학적 구조를 모사하여 제작하였기 때문에 방광과 직장을 모사한 구와 원기둥의 구조물을 포함하고 있으며, C-arm과 CT 영상을 정확하게 획득하기 위한 localizer를 포함하고 있다. 또한, C-arm 및 CT 좌표 비교 수행을 위하여 알고리즘에 기반한 재구성 프로그램을 직접 IDL 5.5를 이용, window 환경에서 개발하였다. 좌표 비교를 수행한 결과, CT의 좌표가 정확한 좌표라고 가정했을 때 필름에 기반한 방법은 모든 점에서 1.0 mm 이내에서 일치함을 확인할 수 있었다. 본 연구를 바탕으로 우리는 현재 사용하고 있는 Plato (Nucletron, Netherlands) 근접치료 기기의 위치 확인 알고리즘에 대한 검증을 자체적으로 수행할 수 있었다. 이번 연구에서 새롭게 제작된 팬톰과 소프트웨어는 근접치료의 Qual Assurance (OA) 분야에서 효율적이고 강력한 QA 도구로 자리 잡을 수 있을 것으로 기대된다.

  • PDF

Determination of dosimetric dependence for effective atomic number of LDR brachytherapy seed capsule by Monte Carlo simulation

  • Berkay Camgoz;Dilara Tarim
    • Nuclear Engineering and Technology
    • /
    • 제55권8호
    • /
    • pp.2734-2741
    • /
    • 2023
  • Brachytherapy is a special case of radiotherapy. It should be arranged according to some principles in medical radiation applications and radiation physics. The primary principle is to use as low as reasonably achievable dose in all ionizing radiation applications for diagnostic and therapeutic treatments. Dosimetric distributions are dependent on radioactive source properties and radiation-matter interactions in an absorber medium such as phantom or tissue. In this consideration, the geometrical structure and material of the seed capsule, which surrounds a radioactive material, are directly responsible for isodose profiles and dosimetric functions. In this study, the radiometric properties of capsule material were investigated on dose distribution in a water phantom by changing its nuclear properties using the EGSnrc Monte Carlo (MC) simulation code. Effective atomic numbers of hypothetic mixtures were calculated by using different elements with several fractions for capsule material. Model 6711 brachytherapy seed was modeled by EGSnrc/Dosrcnrc Code and dosimetric functions were calculated. As a result, dosimetric parameters of hypothetic sources have been acquired in large-scale atomic number. Dosimetric deviations between the data of hypothetic seeds and the original one were analyzed. Unit dose (Gy/Particle) distributions belonging to different types of material in seed capsule have remarkably differed from the original capsule's data. Capsule type is major variable to manage the expected dose profile and isodose distribution around a seed. This study shows us systematically varied scale of material type (cross section or effective atomic number dependent) offers selective material usage in production of seed capsules for the expected isodose profile of a specific source.

Calibration of $^{192}Ir$ HDR Brachytherapy Source in Air and in a Cylindrical Phantom

  • Djarwani S. Soejoko;I, Arief-Riva'
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.23-27
    • /
    • 2002
  • Two $^{192}$ Ir HDR brachytherapy sources were calibrated with a Farmer ionization chamber in air method and in a PMMA cylindrical phantom. The calibration air method used ionization chamber with buildup cap, and 8 variation distances for center-to-center of the source to chamber. In the optimum distance the measured activity, especially for the high activity source, deviation was 0.3% from the activity provided by manufacturer. Calibration with a PMMA cylindrical phantom was less sensitive, and suitable for quick check method with accuracy less than 10%.

  • PDF

근접방사선치료 시 몬테카를로 전산모사를 이용한 인체전산팬텀의 우측 폐와 주변 장기 선량평가 (Evaluation of Absorbed Dose for the Right Lung and Surrounding Organs of the Computational Human Phantom in Brachytherapy by Monte Carlo Simulation)

  • 이준성;김양수;김민걸;김정수;이선영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권6호
    • /
    • pp.443-451
    • /
    • 2020
  • This study is to evaluate absorbed dose from right lung for brachytherapy and to estimate the effects of tissue heterogeneities on dose distribution for Iridium-192 source using Monte Carlo simulation. The study employed Geant4 code as Monte Carlo simulation to calculate the dosimetry parameters. The dose distribution of Iridium-192 source in solid water equivalent phantom including aluminium plate or steel plate inserted was calculated and compared with the measured dose by the ion chamber at various distances. And the simulation was used to evaluate the dose of gamma radiation absorbed in the lung organ and other organs around it. The dose distribution embedded in right lung was calculated due to the presence of heart, thymus, spine, stomach as well as left lung. The geometry of the human body was made up of adult male MIRD type of the computational human phantom. The dosimetric characteristics obtained for aluminium plate inserted were in good agreement with experimental results within 4%. The simulation results of steel plate inserted agreed well with a maximum difference 2.75%. Target organ considered to receive a dose of 100%, the surrounding organs were left the left lung of 3.93%, heart of 10.04%, thymus of 11.19%, spine of 12.64% and stomach of 0.95%. When the statistical error is performed for the computational human phantom, the statistical error of value is under 1%.

자궁경부암용 팬톰을 이용한 HDR (High dose rate) 근접치료의 선량 평가 (Dose Verification Using Pelvic Phantom in High Dose Rate (HDR) Brachytherapy)

  • 장지나;허순녕;김회남;윤세철;최보영;이형구;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제14권1호
    • /
    • pp.15-19
    • /
    • 2003
  • HDR (High dose rate) 근접 치료는 기존의 LDR (Low dose rate) 근접 치료에서 야기되었던 치료 시간이나 선량 최적화 등의 문제점을 해결하였기 때문에 자궁경부암 치료에 많이 사용되고 있다. 그러나, 단시간에 고선량이 조사되는 HDR 근접치료에서 치료 효과를 극대화시키기 위해서는 선량 계산 알고리즘, 위치 계산 알고리즘, 최적화 알고리즘이 정확하게 검증되어야 한다. 이를 위해서는 인체 등가 팬톰과 치료 계획 컴퓨터의 선량 분포 곡선을 비교함으로써 검증할 수 있다. 본 연구에서는 이러한 검증이 가능하도록 자궁경부암용 팬톰을 설계, 제작하여 HDR 치료 계획 컴퓨터와 팬톰과의 선량을 비교, 평가하는 것이다 이 자궁경부암용 팬톰은 높은 해상도를 가진 선량 측정기를 사용하여 정량적인 평가가 가능하도록 제작되었고, 인체 등가물질인 물과 아크릴을 사용하여 제작하였다 또한, 팬톰 내의 방사선량 측정을 위해서 $\frac{1}{8}$ 인치 TLD (Thermoluminescent dosimeters) 칩과 공간 해상도가 1 mm 이내인 필름을 사용하였다. 이 자궁경부암용 팬톰는 HDR applicator의 고정을 위해 applicator 홀더의 홈 안에 HDR applicator가 삽입되게 제작하였고 세 개의 TLD 홀더에는 TLD 칩(TLD 간의 거리는 5 mm)이 정렬되게 제작하여 A점이나 B점 같은 특정 점의 절대 선량을 측정할 수 있게 제작하였다 필름은 3개의 직교(orthogonal) 평면에 삽입되도록 제작하여 상대 선량 측정이 가능하게 하였다. 사용된 치료 계획 시스템은 Nucletron Plato system이고, Microselectron Ir-192 소스를 사용하였다. 선량 평가 결과, TLD 선량의 경우 A, B point를 포함하여 직장과 방광 선량이 $\pm$4% 이내로 치료계획 컴퓨터(Plato, Nucletron)와 일치하였고, 필름의 경우 선량 분포 곡선이 치료계획 컴퓨터의 선량 분포 곡선 패턴과 거의 일치하는 우수한 결과를 보였다. 제작된 자궁경부암용 팬톰은 HDR 치료 계획 컴퓨터의 선량 계산 알고리즘의 평가 및 검증에 유용하게 사용될 것이고, 이 팬톰은 강남성모병원 치료방사선과 HDR 근접치료 기기의 선량과 위치확인의 QA(quality assurance) 도구로써 사용하려고 추진 중에 있다.

  • PDF

고선량률(HDR) 근접치료의 동위원소 Ir-192에 대한 측정방법에 관한 고찰 (A Study on Calibration Procedures for Ir-192 High Dose Rate Brachytherapy Sources)

  • 백태성;이승욱;나수경
    • 대한방사선치료학회지
    • /
    • 제19권1호
    • /
    • pp.19-26
    • /
    • 2007
  • 목 적: Ir-192 고선량율 근접치료(HDR Brachytherapy)선원에 대한 다양한 측정절차의 효율을 서로 비교할 것이며, 측정 장비의 추가 구입 없이 대안으로 새롭게 만든 PMMA (polymethylmethacrylateplastics: $C_5H_8O_2$) plate phantom에 대한임상에서의 적합성과 유용성을 알아 보았다. 대상 및 방법: 세 가지 형태(Well type chamber, Source calibration jig, PMMA plate phantom)의 측정 시스템을 이용하여 측정값을 비교하였다. Source calibration jig와 PMMA plate phantom을 사용 했을 때에는 Farmer type chamber를 이용하여 측정하였으며, 각각 5회씩 측정하여 제조업체의 측정치와 비교하였다. 또한 새로운 선원을 교환 할 때마다 제조업체로부터 선원과 함께 제공되는 제조업체의 측정치를 본 연구의 측정치와 비교하여 방사능의 정확도를 평가 하였다. 결 과: Well type chamber, Source calibration jig, PMMA plate phantom를 사용한 Ir-192 선원의 측정결과 제조업체 측정치와의 상대오차에 대한 RMS (Root Mean Square)값은 Well type chamber에서 0.6%, Source calibration jig에서 1.57%, PMMA plate phantom에서는 2.1%를 나타내었다. 또한 평균 오차에 대한 편차는 Well type chamber에서 $-0.2{\pm}0.5%$, Source calibration jig에서 $0.97{\pm}1.23%$, PMMA plate phantom에서는 $-0.89{\pm}1.87%$를 나타내었다. 결 론: 본 연구를 통해 실험한 세 가지 형태(Well type chamber, Source calibration jig, PMMA plate phantom)의 측정 시스템의 결과에서 나타난 것처럼, Well type chamber를 이용한 측정결과가 가장 우수하게 나타났다. 또한 측정 장비를 구입하지 않고 대안으로 새롭게 만든 PMMA plate phantom의 결과 권고안 ${\pm}5%$를 초과하지 않으므로 임상에서 유용하게 사용 할 수 있을 것이라 생각되어진다.

  • PDF