• Title/Summary/Keyword: box

Search Result 6,629, Processing Time 0.032 seconds

The Prediction of Temperature in Composite Box Girder Bridges (합성 박스형 교량의 온도 예측)

  • Chang, Sung Pil;Im, Chang Kyun
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.3 s.32
    • /
    • pp.431-440
    • /
    • 1997
  • The paper describes a theoretical model for the prediction of bridge temperatures from meteorological data measured at bridge site and local meteorological center together with existing finite element heat transfer theory and solar radiation transfer theory to determine the time dependent temperature distribution of bridge. In this analytical model, the most adequate equation for the calculation of solar radiation on the bridge surface, which is dominant in day time is described based on the results of several experimental studies for the solar energy. The validity of this model is tested against field data obtained from long term experimental program on Sadang Viaduct in Seoul. Also, this paper describes the linear correlation between design variables and meteorological data to establish analytical criteria for the prediction of the average temperature, which are responsible for the longitudinal deformation of the bridges and of the vertical differential temperature profiles. which are responsible for the bending deformations from the long term experimental results.

  • PDF

Changes in Skp2 in Helicobacter pylori-Infected Gastric Epithelial Cells (Helicobacter pylori에 감염된 위상피세포에서 Skp2의 변화)

  • Chung, Hae-Yun
    • The Korean Journal of Food And Nutrition
    • /
    • v.25 no.1
    • /
    • pp.64-68
    • /
    • 2012
  • It has been suggested that Helicobacter pylori(H. pylori) infections can promote the development and progression of gastric cancer through the modulation of cell cycle regulators such as $p27^{Kip1}$ and Skp2. $p27^{Kip1}$ is a cyclin-dependent kinase (CDK) inhibitor that blocks the G1/S transition necessary for cell cycle progression. Skp2 is a component of the ubiquitin ligase complex called $SCF^{Skp2}$(SKP1-Cullin-F-box), which specifically binds and promotes the degradation of $p27^{Kip1}$. A low level of $p27^{Kip1}$ and a high level of Skp2 have been reported in many types of cancers, including gastric cancer. In addition, a decrease in $p27^{Kip1}$ has been reported in H. pylori-infected specimens. However, data on Skp2 in H. pylori infections are limited. This study examines the changes in the status of Skp2 in H. pylori-infected gastric epithelial AGS cells. For this, we stimulated AGS cells with H. pylori(NCTC 11637) at the ratio of 300:1(bacterium:cell) for 6 hours. The results of an immunoprecipitation analysis, followed by a western blot, indicate that the interaction between Skp2 and 14-3-3 was elevated 3 hours after the H. pylori treatment. In addition, there was an increase in cytoplasmic Skp2 after 3 hours, whereas there was no change in the nuclear level. Since it has been reported that interaction with 14-3-3 and the subsequent cytoplasmic translocation of Skp2 can increase its protein stability, increases in the interaction with 14-3-3 and the cytoplasmic Skp2 after the H. pylori treatment can increase the level of Skp2 in AGS cells. This phenomenon may explain, at least to some extent, the mechanism underlying the relationship between H. pylori infections and gastric carcinogenesis.

Development of the Near Infrared Camera System for Astronomical Application

  • Moon, Bong-Kon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.39.2-39.2
    • /
    • 2010
  • In this paper, I present the domestic development of near infrared camera systems for the ground telescope and the space satellite. These systems are the first infrared instruments made for astronomical observation in Korea. KASINICS (KASI Near Infrared Camera System) was developed to be installed on the 1.8m telescope of the Bohyunsan Optical Astronomy Observatory (BOAO) in Korea. KASINICS is equipped with a $512{\times}512$ InSb array enable L band observations as well as J, H, and Ks bands. The field-of-view of the array is $3.3'{\times}3.3'$ with a resolution of 0.39"/pixel. It employs an Offner relay optical system providing a cold stop to eliminate thermal background emission from the telescope structures. From the test observation, limiting magnitudes are J=17.6, H=17.5, Ks=16.1 and L(narrow)=10.0 mag at a signal-to-noise ratio of 10 in an integration time of 100 s. MIRIS (Multi-purpose InfraRed Imaging System) is the main payload of the STSAT-3 in Korea. MIRIS Space Observation Camera (SOC) covers the observation wavelength from $0.9{\mu}m$ to $2.0{\mu}m$ with a wide field of view $3.67^{\circ}{\times}3.67^{\circ}$. The PICNIC HgCdTe detector in a cold box is cooled down below 100K by a micro Stirling cooler of which cooling capacity is 220mW at 77K. MIRIS SOC adopts passive cooling technique to chill the telescope below 200K by pointing to the deep space (3K). The cooling mechanism employs a radiator, a Winston cone baffle, a thermal shield, MLI of 30 layers, and GFRP pipe support in the system. Opto-mechanical analysis was made in order to estimate and compensate possible stresses from the thermal contraction of mounting parts at cryogenic temperatures. Finite Element Analysis (FEA) of mechanical structure was also conducted to ensure safety and stability in launching environments and in orbit. MIRIS SOC will mainly perform the Galactic plane survey with narrow band filters (Pa $\alpha$ and Pa $\alpha$ continuum) and CIB (Cosmic Infrared Background) observation with wide band filters (I and H) driven by a cryogenic stepping motor.

  • PDF

Gyro-Mouse for the Disabled: 'Click' and 'Position' Control of the Mouse Cursor

  • Eom, Gwang-Moon;Kim, Kyeong-Seop;Kim, Chul-Seung;Lee, James;Chung, Soon-Cheol;Lee, Bong-Soo;Higa, Hiroki;Furuse, Norio;Futami, Ryoko;Watanabe, Takashi
    • International Journal of Control, Automation, and Systems
    • /
    • v.5 no.2
    • /
    • pp.147-154
    • /
    • 2007
  • This paper describes a 'gyro-mouse', which provides a new human-computer interface (HCI) for persons who are disabled in their upper extremities, for handling the mouse-click and mouse-move function. We adopted the artificial neural network to recognize a quick-nodding pattern of the disabled person as the gyro-mouse click. The performance of our gyro-mouse was evaluated by three indices that include 'click recognition rate', 'error in cursor position control', and 'click rate per minute' on a target box appearing at random positions. Although it turned out that the average error in cursor positioning control was 1.4-1.5 times larger than that of optical mouse control, and the average click rate per minute was 40% of the optical mouse, the overall click recognition rate was 93%. Moreover, the click rate per minute increased from 35.2% to 44% with repetitive trials. Hence, our suggested gyro-mouse system can be used to provide a new user interface tool especially for those persons who do not have full use of their upper extremities.

Design of Broadband Polarization Diversity Antenna for Mobile Base Stations (이동 통신 기지국용 광대역 편파 다이버시티 안테나 설계)

  • Seo, In-Jong;Cho, In-Ho;Lee, Cheon-Hee;Jung, Jin-Woo;Lee, Hyeon-Jin;Lim, Yeong-Seog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.9
    • /
    • pp.1023-1029
    • /
    • 2010
  • In this paper, we proposed the broadband polarization diversity antenna operating in the PCS, WCDMA and WiBro band for mobile base station. We designed the antenna using the dipole antenna of the square loop type and microstrip feeding structure. Additionally, we used the choke box to remove the distortion of radiation patterns by the reflector structure when operating broadband. The simulation was performed using MWS in a commercial tool of CST company and the antenna was fabricated on a teflon substrate with 3.33 of the relative permittivity. The proposed antenna has the bandwidth of 640 MHz(from 1.75 to 2.39 GHz) when VSWR is below 1.5. At the operating bands, the interisolation between the cross-pair radiators is less than -25 dB and the maximum gains for PCS, WCDMA and WiBro band are 8.9, 8.2 and 8.6 dBi, respectively.

A Study on Slot Coupled Capacitor Resonator for Non-Invasive Glucose Monitoring in Earlobe (귓불에서 비침습 혈당관찰을 위한 슬롯결합 커패시터 공진기 연구)

  • Yun, Gi-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.4
    • /
    • pp.279-285
    • /
    • 2017
  • In this paper, the resonator with a parallel plate capacitor is newly proposed around sub-microwave frequency band and applied to earlobe for non-invasive glucose monitoring the human biological tissue. The capacitor including the earlobe as dielectric material is connected to inductive slot in the ground plane of the microstrip line. Based on the simulation, one port resonator circuit is designed and fabricated as a prototype. Three step glucose concentration levels(0, 250, 500 mg/dL) was tested, and its reflection coefficients($S_{11}$) were measured. Owing to high Q resonator more than 100, resonant frequency shift of about 9 MHz per glucose level of 250 mg/dL has been successfully measured. This proves that the proposed sensor is applicable to a blood glucose sensor.

Estimation of Dynamic Interface Friction Properties of Geosynthetics (토목섬유의 동적 경계면 마찰특성 평가)

  • 김동진;서민우;박준범;박인준
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.265-275
    • /
    • 2003
  • In this study, shaking table tests were conducted to estimate dynamic interface properties between geosynthetics such as geomembrane, geotextile and geosynthetic clay liner. Accelerations of both shaking table and upper box, and relative displacements between geosynthetics under dynamic loading were measured. Also, the influence of normal stress, frequency of excitation and dry/wet conditions were investigated through the analyses of test results. from the test results, it was found that there is a limited acceleration below which dynamic farce can be transmitted between geosynthetics without the loss of horizontal acceleration. Dynamic interface friction angle between geosynthetics could be calculated through the limited acceleration. Relative displacements induced along geosynthetic interfaces under dynamic loading were not consistent depending on the type of interface and test conditions. The maximum slip displacements between geosynthetics are normalized and normalized slip equations were developed for each interface. By using the normalized slip equation, maximum slip displacements for the geosynthetic interface could be predicted for the given base acceleration and frequency of excitation.

Analysis of Grounding Resistance for Zero Energy Town Floating PV System Using Underground Wiring (매설지선 방식을 적용한 에너지 자립마을용 수상 태양광 발전 시스템의 접지저항 분석)

  • Ko, Jae-Woo;Lim, Jong-Log;Kim, David K.;Cha, Hae-Lim;Kim, Si-Han;Lee, Chang-Koo;Ahn, Hyung-Keun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.5
    • /
    • pp.303-306
    • /
    • 2016
  • Floating PV system is installed on the water such as artificial lake, reservoir, river for the purposes of zero energy town and/or large scale of PV station. There are electrical gains from cooling effect by water and reflection of water surface. Particularly, floating PV power station with high efficiency solar cell modules receives a lot of attention recently. Floating PV system is installed on the water, which means grounding method to the frame of solar cell and electrical box such as connector band and distribution panelboard should be applied in different way from grounding method of PV system on land. The grounding resistance should be 10[${\Omega}$] in case the voltage is over 400[V] in accordance with Korean Standard. The applicable parameters are the resistivity of water in various circumstances, depth of water, and length of electrode in order to meet 10[${\Omega}$] of grounding resistance. We calculated appropriate length of the electrode on the basis of theoretical equation of grounding resistance and analyzed the relation between each parameters through MATLAB simulation. This paper explains grounding system of floating PV power station and presents considerations on grounding design according to the resistivity of water.

A Study on the Evaluation of Horizontal, Vertical, Asymmetric and Coupling Multipliers of the NIOSH Lifting Equation in Korean Male (한국인 20대 남성의 NIOSH Lifting Equation 계수평가에 관한 연구)

  • Bae, Dong-Chul;Kim, Yong-Jae
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.2
    • /
    • pp.83-88
    • /
    • 2009
  • The objective of this paper was to evaluate the effectiveness of horizontal, vertical, asymmetric and coupling multipliers for manual material handling. Lifting tasks with 5 different horizontal distances ($30{\sim}70cm$) for 6 vertical distances(ankle, knee, waist, elbow, shoulder and head height) were experimented. The muscle activity and muscle exertion level during asymmetric load handling(without trunk flexion) was experimented. Lifting tasks with and without handle tote box for three postures(straight, bending, right angle posture) were experimented. The degrading tendency did not appeared almost in $60{\sim}70cm$ interval's horizontal distance. As a result of ANOVA, MVC paid attention to horizontal and vertical distance but cross effect was insignificant(p<0.01). The change of the MVC according to the horizontal, vertical distance appeared similar from of RWL. The results of normalized MVC measurement were decreased about 16%, 24%, 34% respectively as the asymmetry angle was $30^{\circ}$, $60^{\circ}$, $90^{\circ}$. RMS EMG values of right erector spinae muscles were decreased as the work posture went to $90^{\circ}$ and those of left erector spinae muscles were increased until the asymmetry angle was $40^{\circ}$ but decreased continually over $40^{\circ}$. 7 subjects, activities of left and right latissimus dorsi muscles were maintained constantly, while for remainer, those were irregular. MVC reduced maximum 23% by type of handle. MVC was highest in straight posture, but was lowest in right angle posture. As a result of ANOVA, MVC paid attention to posture, coupling(p<0.01). To all handle types, biceps brachii activity was increased in right angle posture, but reduced in straight posture. Based on the results of this study, it is suggested that the NIOSH guideline should not be directly applied to Korean without reasonable reexamination. In addition, we need to afterward study through an age classification.

The Experimental Evaluation of the Mixed Mode Delamination in Woven CFRP/GFRP Laminates under MMB Test (MMB시험에 의한 평직 CFRP/GFRP 적층판 혼합모드 층간분리의 실험적 평가)

  • Kwak, Jung-Hoon;Kang, Ji-Woong;Kwon, Oh-Heon
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.4
    • /
    • pp.14-18
    • /
    • 2013
  • Blades of horizontal axis are nowadays made of composite materials. Generally, composite materials satisfy design provides lower weight and good stiffness, while laminate composites have often damages as like the delamination and cracks at the interface of laminates. The box spar and tail parts of a blade are composed of the CFRP/GFRP hybrid laminate composites. However, delamination and the interfacial crack often occur in the interface of CFRP/GFRP hybrid laminate composites under the mixed mode fracture condition, especially mode I and mode II. Therefore, there is a need for the evaluation of the mixed mode fracture behavior during the delamination of CFRP/GFRP hybrid laminates. This study shows the experimental results for the delamination fracture toughness in CFRP/GFRP hybrid laminate composites. Fracture toughness experiments and estimation are performed by using DMMB(Dissimilar mixed mode bending) specimen. The materials used in the test are a commercial woven type CFRP(Carbon fiber reinforced plastic) prepreg(CF3327) and UD type GFRP(Glass fiber reinforced plastic) prepreg(HD224A). A CFRP/GFRP hybrid laminate composite is composed by the 10 plies CFRP and GFRP prepreg for DMMB. A thickness of CFRP and GFRP layer is 2.5mm and 3.0mm, respectively. Also the fulcrum location which is a loading parameter is changed from 80 to 100mm on the specimen of length 120mm because it defines the ratio of mode I to mode II. In this study, the effects of the fulcrum location are evaluated in the viewpoint of energy release rate in mode I and mode II contribution. The results show that the delamination crack initiates at higher displacement and lower load according to the increase of the fulcrum location ratio. And the variation of the energy release rate for mode I and II contributions for the mode mixity are shown.