• 제목/요약/키워드: boundary artifact

검색결과 52건 처리시간 0.025초

Moire artifact 제거 후 그리드 주파수에 따른 미세병변의 영상분석 (Image Analysis of Micro Lesions According to Grid Frequency After Removal of Moire Artifact)

  • 이상호;김규형;양오남
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권5호
    • /
    • pp.463-469
    • /
    • 2018
  • Morphological information such as shape and margin of micro lesion is important information for diagnosis of disease in clinical imaging. In this study, we investigated the morphological changes of the micro lesions by comparing the contrast and area in grid suppressed DR images according to grid frequency. In the profile analysis of the image, the mass showed an average intensity variation of 8.6 ~ 72.4 after suppression, The higher the grid frequency, the more the contrast was increased. However, in the images obtained using 103 lp / inch, which is a grid frequency less than the sampling frequency, the contrast of the mass in the vertical direction decreased after suppression. In the binary image, the area change of the mass was also large. As a result, the shape, size, and margin of the mass changed. In the case of very small calcification, the higher the grid frequency is the larger the change in contrast, so that a clear image can be obtained in the post-suppression image. However, we could confirm that the margin of the lesion was blurred and the lesion was lost in some of the images using the 103 lp / inch grid. The higher the frequency of the grid, The change of the contrast of fiber occurred largely and clear boundary was confirmed. The decrease of the number of pixels was small and morphological change was small. In conclusion, when using a grid frequency that is not suitable for the sample frequency, morphological changes or lesion loss of micro lesions in the post- suppression image may give the possibility of misdiagnosis in diagnosis and differentiation of the image.

위상차 현미경 영상 내 푸리에 묘사자를 이용한 암세포 형태별 분류 (Classification of Tumor cells in Phase-contrast Microscopy Image using Fourier Descriptor)

  • 강미선;이정엄;김혜련;김명희
    • 대한의용생체공학회:의공학회지
    • /
    • 제33권4호
    • /
    • pp.169-176
    • /
    • 2012
  • Tumor cell morphology is closely related to its migratory behaviors. An active tumor cell has a highly irregular shape, whereas a spherical cell is inactive. Thus, quantitative analysis of cell features is crucial to determine tumor malignancy or to test the efficacy of anticancer treatment. We use 3D time-lapse phase-contrast microscopy to analyze single cell morphology because it enables to observe long-term activity of living cells without photobleaching and phototoxicity, which is common in other fluorescence-labeled microscopy. Despite this advantage, there are image-level drawbacks to phase-contrast microscopy, such as local light effect and contrast interference ring. Therefore, we first corrected for non-uniform illumination artifacts and then we use intensity distribution information to detect cell boundary. In phase contrast microscopy image, cell is normally appeared as dark region surrounded by bright halo ring. Due to halo artifact is minimal around the cell body and has non-symmetric diffusion pattern, we calculate cross sectional plane which intersects center of each cell and orthogonal to first principal axis. Then, we extract dark cell region by analyzing intensity profile curve considering local bright peak as halo area. Finally, we calculated the Fourier descriptor that morphological characteristics of cell to classify tumor cells into active and inactive groups. We validated classification accuracy by comparing our findings with manually obtained results.

HDR 영상 복원을 위해 대비와 텍스쳐 영역 정보를 고려한 혼합 톤 매핑 기법 (Hybrid Tone Mapping Technique Considering Contrast and Texture Area Information for HDR Image Restoration)

  • 강주미;박대준;정제창
    • 방송공학회논문지
    • /
    • 제22권4호
    • /
    • pp.496-508
    • /
    • 2017
  • 본 논문은 전역적 대비를 보존하는 동시에 경계 정보를 정확히 보존할 수 있는 혼합 톤 매핑 기법 (Tone Mapping Operator: TMO)을 제안한다. 우선, 넓은 동적 영역 (High Dynamic Rangae: HDR) 영상을 낮은 동적 영역 (Low Dynamic Range: LDR) 디스플레이에 적합하게 압축하기 위해 인간의 시각 시스템 (Human Visual System: HVS)에 기반한 임계 값 대 밝기 값 (Threshold vs. Intensity: TVI) 함수와 영상의 대비를 사용하였으며 이에 따라 영상의 전역적인 대비를 보존할 수 있었다. 또한, 가이디드 영상 필터링 (Guided Image Filtering: GIF)을 이용하여 검출된 경계 정보와 변화감지역 (Just Noticeable Difference: JND) 모델의 공간적 마스킹을 이용하여 검출된 경계 정보를 결합함으로써 영상의 경계를 보존하고 출력 영상의 인지적 화질을 향상시켰다. 기존에 TMO들은 크게 전역적 톤 매핑 (Global Tone Mapping: GTM)과 지역적 톤 매핑 (Local Tone Mapping: LTM)으로 분류되었다. GTM은 전역적인 대비를 보존하며 구현이 단순해 실행시간이 빠르다는 장점이 있지만 영상의 경계 정보가 손실되며 지역적 대비를 보존하지 못하는 단점이 있었다. 반면 LTM은 영상의 지역적 대비와 경계 정보를 잘 보존하였지만 경계 영역에서의 헤일로 열화 현상의 발생과 같이 일부 영역이 부자연스럽게 표현되는 경우가 발생하였으며 GTM과 비교하여 높은 계산 복잡도를 가졌다. 따라서 본 논문에서는 GTM과 LTM의 장점을 결합하여 전역적인 대비를 보존하는 동시에 영상의 경계 정보를 보존하는 TMO를 제안하였으며 실험결과를 통해 제안하는 톤 매핑 기법이 인지적 화질 측면에서 성능이 우수한 것으로 확인되었다.

컬러 결점을 줄이기 위한 수정된 segment maxima 기반의 색역 추정 (Estimation of Gamut Boundary based on Modified Segment Maxima to Reduce Color Artifacts)

  • 하호건;장인수;이태형;하영호
    • 대한전자공학회논문지SP
    • /
    • 제48권3호
    • /
    • pp.99-105
    • /
    • 2011
  • 본 논문에서는 수정된 segment maxima을 기반으로 한 색역 추정 방법을 제안한다. Segment maxima은 CIELab 공간을 일정한 간격으로 분할하고, 각 분할된 영역의 최외각 측정 데이터를 계산하여 색역을 추정하는 기법이다. 그러나 이 방법은 색공간의 분할 개수에 따라서 지역적인 색역 왜곡이 나타나 색역 사상시에 컬러 결점(color artifact)을 발생시킨다. 색공간 분할 개수가 적으면 높은 채도 부근에서 추정된 색역 정보가 분실되어 컬러 컨투어(color contour) 현상이 발생한다. 이와 반대로 색공간 분할 개수가 많으면 CIELab 밝기 축 부근에서 색역이 오목하게 되는 왜곡이 발생한다. 이러한 지역적인 색역 왜곡은 색역 사상시 결과 영상에 컬러 결점이 유발한다. 제안한 논문에서는 실험을 통하여 측정한 데이터 수에 따른 적절한 색공간 분할개수를 설정하여 높은 채도 부근에 색역 축소를 줄이며, 오목하게 나타나는 지역적인 색역 왜곡을 다양한 색역 분할에 따른 색역 경계 서술자(gamut boundary descriptor) 비교를 통해 이를 수정하는 방법을 제안하였다. 실험을 통해 제안한 방법이 기존의 segment maxima보다 정확한 장치의 색역을 추정할 수가 있었고, 결과 영상에서도 컬러 컨투어나 반점과 같은 컬러 결점이 줄어듬을 확인 할 수 있었다.

초음속 제트소음의 전산유체 모사 시 반사파 아티팩트 제거 기법 (A method for removal of reflection artifact in computational fluid dynamic simulation of supersonic jet noise)

  • 박태영;주현식;장인만;강승훈;엄원석;신상준;박정원
    • 한국음향학회지
    • /
    • 제39권4호
    • /
    • pp.364-370
    • /
    • 2020
  • 우주 발사체의 초음속 플룸으로부터 발생하는 고강도 소음은 발사체에 음향하중으로 작용하여 전장품이나 탑재 위성의 오작동 및 고장을 유발한다. 음향하중을 발생시키는 로켓/제트소음의 예측은 초음속 난류 유동(소음원) 예측을 위한 전산유체해석과 음향(소음 전파) 해석이 결합된 모델이 주로 사용된다. 이때, 유동해석 시 계산영역 경계면에서 발생하는 반사파 아티팩트를 제거하기 위해 경계조건 외에 추가적으로 흡수층(sponge layer)과 같은 모델링이 적용된다. 하지만, 해석 대상에 따라 흡수층의 파라미터 최적화 연구가 선행되어야 하고 더 큰 계산 영역을 필요로 하기 때문에, 이는 해석시간 증가의 주요 요인이 된다. 이에 본 논문에서는 계산효율을 증대시키기 위해 흡수층 대신 유동해석 결과에 존재하는 반사파 아티팩트를 두 개의 마이크로폰 기법을 기반으로 하여 제거하는 방법을 처음으로 제안하고, 이를 실제 소형 초음속 제트소음 해석 결과에 적용하였다.

Automatic Electronic Cleansing in Computed Tomography Colonography Images using Domain Knowledge

  • Manjunath, KN;Siddalingaswamy, PC;Prabhu, GK
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권18호
    • /
    • pp.8351-8358
    • /
    • 2016
  • Electronic cleansing is an image post processing technique in which the tagged colonic content is subtracted from colon using CTC images. There are post processing artefacts, like: 1) soft tissue degradation; 2) incomplete cleansing; 3) misclassification of polyp due to pseudo enhanced voxels; and 4) pseudo soft tissue structures. The objective of the study was to subtract the tagged colonic content without losing the soft tissue structures. This paper proposes a novel adaptive method to solve the first three problems using a multi-step algorithm. It uses a new edge model-based method which involves colon segmentation, priori information of Hounsfield units (HU) of different colonic contents at specific tube voltages, subtracting the tagging materials, restoring the soft tissue structures based on selective HU, removing boundary between air-contrast, and applying a filter to clean minute particles due to improperly tagged endoluminal fluids which appear as noise. The main finding of the study was submerged soft tissue structures were absolutely preserved and the pseudo enhanced intensities were corrected without any artifact. The method was implemented with multithreading for parallel processing in a high performance computer. The technique was applied on a fecal tagged dataset (30 patients) where the tagging agent was not completely removed from colon. The results were then qualitatively validated by radiologists for any image processing artifacts.

Reliability-Based Deblocking Filter for Wyner-Ziv Video Coding

  • Dinh, Khanh Quoc;Shim, Hiuk Jae;Jeon, Byeungwoo
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제5권2호
    • /
    • pp.129-142
    • /
    • 2016
  • In Wyner-Ziv coding, video signals are reconstructed by correcting side information generated by block-based motion estimation/compensation at the decoder. The correction is not always accurate due to the limited number of parity bits and early stopping of low-density parity check accumulate (LDPCA) decoding in distributed video coding, or due to the limited number of measurements in distributed compressive video sensing. The blocking artifacts caused by block-based processing are usually conspicuous in smooth areas and degrade the perceptual quality of the reconstructed video. Conventional deblocking filters try to remove the artifacts by treating both sides of the block boundary equally; however, coding errors generated by block-based processing are not necessarily the same on both sides of the block boundaries. Such a block-wise difference is exploited in this paper to improve deblocking for Wyner-Ziv frameworks by designing a filter where the deblocking strength at each block can be non-identical, depending on the reliability of the reconstructed pixels. Test results show that the proposed filter not only improves subjective quality by reducing the coding artifacts considerably, but also gains rate distortion performance.

비디오 통신 시스템의 실시간 비디오 품질 측정 방법 (Real-Time Video Quality Assessment of Video Communication Systems)

  • 김병용;이선오;정광수;심동규;이수연
    • 대한전자공학회논문지SP
    • /
    • 제46권3호
    • /
    • pp.75-88
    • /
    • 2009
  • 본 논문에서는 실시간 멀티미디어 스트림 서비스에서 발생하는 비디오 품질 저하 요인에 따른 비디오 품질 측정 방법을 제안한다. 비디오 품질 저하에는 대표적으로 비디오 압축과 네트워크의 상태에 의해 발생한다. 본 논문에서는 비디오 압축에 의하여 생기는 화질 저하를 측정하기 위하여 공간 도메인에서 블록킹 왜곡에 대한 정도를 측정하는 방법을 제안한다. 제안하는 블록 경계 강도는 $8{\times}8$ 블록 경계에서 픽셀간의 변화와 경계를 제외한 주변영역에서 픽셀 사이의 변화에 대한 비율로 나타내었다. 반면, 움직임이 부자연스러운 동영상은 지터 및 지연 요소와 같은 네트워크 전송능력의 악화로 인해 비디오 품질 저하가 나타난다. 본 논문에서 제안하는 시간적 저키니스는 연속된 프레임의 대응되는 픽셀간의 밝기 값 차이에 대한 평균과 현재 프레임과 이전 프레임의 재생시간 간격의 평균 및 분산을 이용하는 방법을 제안하였다. 또한, 본 논문에서는 비디오 압축에 의한 품질 측정 방법인 블록 경계 강도와 네트워크에 의한 품질 측정 방법인 시간적 저키니스를 통합하여 비디오의 종합적 품질을 평가하는 Perceptual Video Quality Metric (PVQM)을 제안한다. 제안한 알고리즘의 성능을 평가하기 위하여, 사람이 직접 비디오 품질을 평가하는 Difference of Mean Opinion Score (DMOS)와 제안한 알고리즘을 비교 평가하였다. 그 결과 제안한 PVQM의 결과와 인간 시각에 의하여 평가된 DMOS가 근사함을 확인하였다.

Generating Motion- and Distortion-Free Local Field Map Using 3D Ultrashort TE MRI: Comparison with T2* Mapping

  • Jeong, Kyle;Thapa, Bijaya;Han, Bong-Soo;Kim, Daehong;Jeong, Eun-Kee
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권4호
    • /
    • pp.328-340
    • /
    • 2019
  • Purpose: To generate phase images with free of motion-induced artifact and susceptibility-induced distortion using 3D radial ultrashort TE (UTE) MRI. Materials and Methods: The field map was theoretically derived by solving Laplace's equation with appropriate boundary conditions, and used to simulate the image distortion in conventional spin-warp MRI. Manufacturer's 3D radial imaging sequence was modified to acquire maximum number of radial spokes in a given time, by removing the spoiler gradient and sampling during both rampup and rampdown gradient. Spoke direction randomly jumps so that a readout gradient acts as a spoiling gradient for the previous spoke. The custom raw data was reconstructed using a homemade image reconstruction software, which is programmed using Python language. The method was applied to a phantom and in-vivo human brain and abdomen. The performance of UTE was compared with 3D GRE for phase mapping. Local phase mapping was compared with T2* mapping using UTE. Results: The phase map using UTE mimics true field-map, which was theoretically calculated, while that using 3D GRE revealed both motion-induced artifact and geometric distortion. Motion-free imaging is particularly crucial for application of phase mapping for abdomen MRI, which typically requires multiple breathold acquisitions. The air pockets, which are caught within the digestive pathway, induce spatially varying and large background field. T2* map, that was calculated using UTE data, suffers from non-uniform T2* value due to this background field, while does not appear in the local phase map of UTE data. Conclusion: Phase map generated using UTE mimicked the true field map even when non-zero susceptibility objects were present. Phase map generated by 3D GRE did not accurately mimic the true field map when non-zero susceptibility objects were present due to the significant field distortion as theoretically calculated. Nonetheless, UTE allows for phase maps to be free of susceptibility-induced distortion without the use of any post-processing protocols.

히스토그램 정보와 dark channel prior를 이용한 다해상도 기반 단일 영상 안개 제거 알고리즘 (A Single Image Defogging Algorithm Based on Multi-Resolution Method Using Histogram Information and Dark Channel Prior)

  • 양승용;양정은;홍석근;조석제
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권6호
    • /
    • pp.649-655
    • /
    • 2015
  • 본 논문에서는 효과적인 단일 영상 안개 제거 알고리즘을 제안한다. 잘 알려진 안개 제거 알고리즘인 dark channel prior(DCP)는 경계선 영역에서의 후광 현상(halo artifact) 및 결과 영상의 저대비를 초래하고 전달량 정제(refinement) 과정에서 긴 계산 시간을 필요로 한다. 이러한 문제들을 해결하기 위해 제안한 방법은 전달량을 추정할 때 DCP와 히스토그램 정보로 구성된 비용함수를 이용하고, 빠른 처리를 위해 다해상도 기법을 이용한다. 히스토그램 정보는 안개 제거 결과의 저대비 현상을 방지해주고, 에지 정보를 참고하는 다해상도 기법은 계산 시간을 감소시키고 후광 현상을 방지할 수 있다. 다수의 안개 영상에 대한 실험을 통해 제안한 방법이 기존의 방법들보다 효율적이고 우수함을 확인하였다.