• Title/Summary/Keyword: bone plate and screw

Search Result 77, Processing Time 0.03 seconds

IMMEDIATE RECONSTRUCTION WITH A.C.P AND ILIAC BONE GRAFT AFTER PARTIAL MANDIBULECTOMY ON RECURRENT AMELOBLASTOMA. (재발된 법랑아세포종 환자에서 하악골 부분절제술후 금속판과 자가장골을 이용한 즉시재건술에 대한 증례보고)

  • Moon, Haeng-Gyu;Yeo, Hwan-Ho;Kill, Beug-Dong;Kim, Woon-Gyu
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.11 no.2
    • /
    • pp.53-59
    • /
    • 1989
  • The ameloblastoma is the most common form of the odontogenic tumors exhibiting minimal inductive change in connective tissue, it comprising 1% of all tumor and cysts of the jaws. It is a true neoplasm, generally considered to be a benign but persistent or, locally malignant lesion. The tumor occurs most commonly in persons between the age of 20 and 50 years. 80% and 90% of all lesions are in the mandible. The presenting clinical signs and symptoms of the ameloblastoma very from patient to patient, but most common symptom was swelling, followed by pain, draining sinuses, and superficial ulcerations. It is slow-growing lesion, and the radiographic features of the ameloblastoma depend large one the nature and the local bone reaction to the particular tumor. Recurrence rate is about 33%, but this is probably due to incommplete initial removal of lesion. We had operated a patient ; 29-year-old female immediate reconstruction combined with autocompression plate and iliac bone graft and screw fixation after hemimandibulaectomy with recurred ameloblastoma involving from premolar to ascending ramus at right side mandible. We obtained favorable results of good function, short intermaxillary fixation periods and easy operation precedure than the other reconstruction methods.

  • PDF

Posterior Cervical Fixation with Nitinol Shape Memory Loop in the Anterior-Posterior Combined Approach for the Patients with Three Column Injury of the Cervical Spine: Preliminary Report

  • Yu, Dong-Kun;Heo, Dong-Hwa;Cho, Sung-Min;Choi, Jong-Hun;Sheen, Seung-Hun;Cho, Yong-Jun
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.5
    • /
    • pp.303-307
    • /
    • 2008
  • Objective: The authors reviewed clinical and radiological outcomes in patients with three column injury of the cervical spine who had undergone posterior cervical fixation using Nitinol shape memory alloy loop in the anterior-posterior combined approach. Materials: Nine patients were surgically treated with anterior cervical fusion using an iliac bone graft and dynamic plate-screw system, and the posterior cervical fixation using Nitinol shape memory loop ($Davydov^{TM}$) at the same time. A retrospective review was performed. Clinical outcomes were assessed using the Frankel grading method. We reviewed the radiological parameters such as bony fusion rate, height of iliac bone graft strut, graft subsidence, cervical lordotic angle, and instrument related complication. Results: Single-level fusion was performed in five patients, and two-level fusion in four. Solid bone fusion was presented in all cases after surgery. The mean height of graft strut was significantly decreased from $20.46{\pm}9.97mm$ at immediate postoperative state to $18.87{\pm}8.60mm$ at the final follow-up period (p<0.05). The mean cervical lordotic angle decreased from $13.83{\pm}11.84^{\circ}$ to $11.37{\pm}6.03^{\circ}$ at the immediate postoperative state but then, increased to $24.39{\pm}9.83^{\circ}$ at the final follow-up period (p<0.05). There were no instrument related complications. Conclusion: We suggest that the posterior cervical fixation using Nitinol shape memory alloy loop may be a simple and useful method, and be one of treatment options in anterior-posterior combined approach for the patients with the three column injury of the cervical spine.

CLINICAL STUDY ON USE OF BIODEGRADABLE PLATE AND SCREW IN ORTHOGNATHIC SURGERY (턱교정 수술에 있어 흡수성 고정판 및 나사 사용에 대한 임상적 연구)

  • Park, Sung-Soo;Choi, Jin-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.2
    • /
    • pp.127-135
    • /
    • 2009
  • Objectives : The titanium fixation system has been used in orthognathic surgery for fixation of bone segments usually, but the biodegradable fixation system was developed and also being used. The strongest point in the biodegradable system is that no extra operation should be needed to remove fixation materials. In spite of this merit, oral & maxillofacial surgeons hesitate to use this system in fracture or orthognathic surgery. In this study, as we got some clinical experiences, we'd like to report the result of clinical study using the biodegradable fixation system in orthognathic surgery. Patients and Methods : A total of 35 patients composed of 17 males and 18 females with 25 osteotomies in maxilla and 34 osteotomies in mandible were fixated with the biodegradable fixation system(Inion $CPS^{(R)}$). We investigated methods of stabilization, fixation time, and complications on the basis of the method as above. Results : Four 2mm thick L shaped plates with 7 holes of which 1 hole was removed were fixed in maxilla with six $2.0{\times}7mm$ screws. Three $2.5{\times}16{\sim}18mm$ screws were used to fix superior ramus area and one mandibular angle area in mandible. It took about 27.4 minutes in maxilla, 25.3 minutes in mandible to perform the fixation which took longer time than the titanium system(9.5 minutes in maxilla, 8 minutes in mandible). Generally, there was no problem except 9 cases in which there were some complications. Conclusions : In most cases, the biodegradable fixation system can be used without problem in usual orthognathic surgery. But, this system is inferior to the titanium fixation one in some respects such as fixation time, size, and physical property. Some supplementations for such weak points as aforementioned should be needed for the universal use of biodegradable materials.

Intracorporeal reduction of condylar fracture using both pedicled condylar and seperated ramal fragments after vertical ramal osteotomy

  • Kim, Il-Kyu;Jang, Jun-Min;Cho, Hyun-Young;Seo, Ji-Hoon;Lee, Dong-Hwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.43 no.5
    • /
    • pp.343-350
    • /
    • 2017
  • The aim of this study is to introduce a surgical technique that can maintain blood supply to prevent condylar resorption in the extracorporeal reduction of condylar fracture. Neither the medial pterygoid muscle on the ramal bone nor the lateral pterygoid muscle on the condylar fragment was detached after vertical ramal osteotomy. Thus, reduction was performed in the intracorporeal state. Therefore, blood supply was expected to be maintained to the fragments of both the condylar and ramal bones. On postoperative radiographs, the anatomical outline of the fractured condyle was well restored, and the occlusion was stable. In the unilateral case, there were no signs of mandibular condylar resorption until postoperative 3 weeks. In the 2 bilateral cases, condylar displacements with plate fractures and screw loosening were observed at postoperative 1 month or 5 months, but radiodensity at the displaced fracture site increased during the follow-up period. Finally, complete remodeling of the condylar fragments with restored anatomic appearance was observed on 8-month or 2-year follow-up radiographs. All cases exhibited good healing aspects with no signs or symptoms of mandibular condylar dysfunction during the postoperative remodeling period after intracorporeal reduction of condylar fracture.

A CLINICAL STUDY OF BIODEGRADABLE PLATES AND SCREWS IN ORAL AND MAXILLOFACIAL SURGERY (구강 악안면 영역의 생체 흡수성 고정판 사용에 관한 임상 연구)

  • Kim, Il-Kyu;Park, Seung-Hoon;Jang, Keum-Soo;Yang, Jung-Eun;Jang, Jae-Won;Sasikala, Balaraman
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.6
    • /
    • pp.451-458
    • /
    • 2009
  • Metallic bone plates and screws have been commonly used in oral and maxillofacial surgery for internal fixation. However, there are several disadvantages such as atrophy of cortical bone inherent to excessive rigid fixation systems, growth disturbance in growing individual, allergy reaction, interference with radiographic imaging, palpability, thermal sensitibity and the need for subsequent removal. To overcome these disadvantages and avoid additional surgery of removal of plates and screws, there have been many studies of biodegradable plates and screws. But, It also has complication such as foreign body reactions. We have undertaken a clinical and retrospective study on 140 patients in Dept. of Oral and Maxillofacial Surgery, Inha University Hospital from February 2006 to March 2009. The purpose of this study is to report the clinical cases and review of the literatures with biodegradable plates and screws. And we concluded following results. 1. 6 cases(3.4%) of the 177 operation sites(140 patients) experienced complications. 1 case(0.6%) was a failure of initial fixation, 1 case(0.6%) was a postoperative infection, 4 cases(2.3%) were inflammations or foreign body reaction. 2. Postoperative infections, inflammations and foreign body reactions were completely recovered with incision and drainage, supporative care with antibiotic coverage and removal of biodegradable plates. 3. Biodegradable plates and screws provide acceptable rigidity and stability clinically. But, long-term observation is required for the tissue reactions around the biodegradable plates and screws because of long resorption periods of the biodegradable materials.

Internal Fixation of Proximal Humerus Fracture with Polyaxial Angular Stable Locking Compression Plate in Patients Older Than 65 Years (65세 이상의 상완골 근위부 골절 환자에서 다축 각안정 잠김 압박 금속판을 이용한 내고정술)

  • Lee, Ki-Won;Choi, Young-Joon;Ahn, Hyung-Sun;Kim, Chung-Hwan;Hwang, Jae-Kwang;Kang, Jeong-Ho;Choo, Han-Ho;Park, Jun-Seok;Kim, Tae-Kyung
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.25-31
    • /
    • 2012
  • Purpose: The clinical and radiographic outcomes of the internal fixation, which were executed on patients over the age of 65 with proximal humerus fracture by using a polyaxial angular stable locking compression plate (Non-Contact-Bridging proximal humerus plate, Zimmer, Switzerland, NCB), were evaluated. Materials and Methods: Thirty two patients over the age of 65 among the proximal humerus fracture treated with NCB plate, between August 2007 and January 2011, were chosen as the subjects. The average age of patients was 71 years, and the average postoperative follow-up period was 11.5 months. The fractures included 14 two-part and 18 three-part fractures. The clinical results were evaluated, using the visual analog scale (VAS) score and the Constant score. The radiological results were evaluated by time to union and Paavolainen method, which measures the neck shaft angle. Results: At the last follow-up examination, the mean VAS score was 3 points and the mean Constant score was 64.5 points, with bone union achieved after the average of 16.2 weeks following the surgery in all the cases. The mean neck shaft angle was 125.9 and 24 cases had good results, while 8 cases had fair results by Paavolainen method, at the last follow-up. There were 1 case of delayed union and cerclage wire failure, and 3 cases of subacromial impingement. There were no complications, such as loss of reduction, nonunion, screw loosening, or avascular necrosis of the humeral head. Conclusion: Internal fixation, using a NCB plate, was considered to be an effective surgical method in treating proximal humerus fracture in the elderly patients, on whom the fixation of the fracture and maintenance of reduction are difficult.

Simultaneous Reduction of Contralateral Malar Complex in Cases of Unilateral Zygoma Bone Fracture (편측 관골 골절에서 동시 반대측 관골 축소술)

  • Kim, Peter Chan-Woo;Lee, Byung-Kwon;Bae, Ji-Suk
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.851-860
    • /
    • 2011
  • Purpose: Reduction by simply assembling bones is recognized as treatment for a zygoma fracture. However, in patients who originally had a protruding zygoma, the fractured parts look like malarplasty after the edema subsides, giving a soft impression which patients notice. Thus, we created symmetry through simultaneous contralateral malar reduction in a unilateral zygoma fracture. Methods: In this study, the patients who had surgery between July, 2008 and December, 2009 with admission were object. In 76 patients with a zygoma fracture, the patients with bilateral zygoma fractures were excluded. Among 48 patients who had a reduction only after a unilateral zygoma fracture, the patients hoping for a reduction of their rough protruding zygoma were analyzed with front cephalometry. The study progressed on 22 patients who had simultaneous contralateral malar reduction in a unilateral zygoma fracture with consent. After fixing the fracture, we did a straight zygoma osteotomy through a 1.5 cm intraoral incision. After that, we created symmetry with a special ruler and fixed the broken zygomatic arch with a screw and plate. We evaluated the facial index and satisfaction with a statistical analysis before and after the surgery. Results: In 22 patients, there was no reoperation except for 1 patient who had a zygoma fracture. None of the patients were treated for infection or hematoma. Two patients complained of paresthesia after the malar reduction operation, but this subsided in 4 months. Most of them were satisfied with the malar reduction, especially the women, and we obtained a better mid facial contour with decreased facial width ($p$ <0.05). Conclusion: Existing zygoma fracture surgery focuses on anatomical reduction. However, we need to have a cosmetic viewpoint in fractures as interests of face contour arise. Thus, contralateral malar reduction got a 4.7 (range 0~5) from patients who had malar reduction surgery in our hospital. Although adjusting to all zygoma fractures has limitations, it can be a new method in zygoma fractures when there are limited indications of protruding zygoma and careful attention is given to patients' high demands.