• Title/Summary/Keyword: bonding surface

Search Result 1,571, Processing Time 0.027 seconds

The study of Design Surface Treatment Obtained Metal Color in Magnesium Alloy

  • Lee, Jung Soon;Lee, Hee Myoung
    • Applied Science and Convergence Technology
    • /
    • v.26 no.2
    • /
    • pp.21-25
    • /
    • 2017
  • The shape of the reflection spectrum is complex and appears to overlap with several signals, because the surface state is uneven due to the natural oxide film, so that the spectrum becomes a complicated signal shape divided into regions 1 and 2 due to diffuse reflection. On the other hand, it is seen that the reflection spectrum after PEO surface treatment is overlapped with several signals. In addition, the reflectance of the energy band varies from 1.32 to 1.46 eV. Usually, the MgO-type oxide film was observed at an energy band of ~4.2 eV. The thickness of the oxide film was increased as the DC voltage was increased by the thin film thickness meter (QuaNix; 7500M) after Plasma Electrolytic Oxidation (; PEO) surface treatment. This is because the higher the DC voltage, the easier the binding of the $OH^-$ ions in the solution solution and the $Mg^+$ ions of the magnesium alloy. An important part of the bonding of ordinary ions is the energy source (plasma) which can promote bonding. However, when a certain threshold voltage or more is applied, the material is adversely affected. The oxide film of the surface may be destroyed without increasing the thickness of the oxide film, that is, whitening of the material may occur.

EFFECTS OF THE DIFFERENT CERAMIC BRACKET BASES ON SHEAR BOND STRENGTH (도재브라켓 접착면의 처리방식이 전단결합강도에 미치는 영향)

  • Kim, Jin-Oh;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.24 no.4 s.47
    • /
    • pp.957-967
    • /
    • 1994
  • The purpose of this study was to evaluate the effects of different bases of ceramic brackets on shear bond strength and to observe failure patterns of bracket bondings. Lower bicuspid brackets whose bases designed for the macromechanical and silane treated chemical bonding those for silane treated chemical bonding, those for micromechanical bonding, and those for macromechanical bonding were tested as experimental groups, and foil mesh-backed metal brackets as a control group. All the brackets were bonded with $Mono-Lok\;2^{(TM)}$ on the labial surface of extracted human lower bicuspids after etching the enamel with $38\%$ phosphoric acid solution for 60 seconds. The shear bond strengths were measured on the universal test machine after 24 hours passed in the $37^{\circ}C$ water bath. The gathered data were evaluated and tested by ANOVA and Duncan's multiple range test, and those results were as follows. The shear bond strengths of brackets for macromechanical and chemical bonding, those for chemical bonding, and those for micromechanical bonding were not different (p>0.05), but showed statistically higher than those of metal bracket and those of ceramic bracket for micromechanical bonding(p<0.05). The shear bond strengths of ceramic bracket for micromechanical bonding showed statistically lower than those of metal bracket(p<0.05). The enamel fractures and/or ceramic bracket fractures were observed in the cases of higher bond strength than that of metal bracket. These results supported that silane treated base of ceramic bracket show higher shear bond strength than that of metal bracket, and suggested that micromechanical form of ceramic bracket bases show higher shear bond strength than that of macromechanical form.

  • PDF

A STUDY ON THE BONDING STRENGTH OF RESILIENT DENTURE LINERS (탄성 의치상 이장재의 접착력에 관한 연구)

  • Lee Sang-Hoon;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.3
    • /
    • pp.411-436
    • /
    • 1992
  • The purpose of this study was to assess the adhesion of resilient denture liners (such as, heat-cured silicone molloplast B,cold- cured silicone Mollosil) to polymethyl metacrylate (K-33) and metal (Megalloy) in the laboratory by peel test. The resilient denture lines were processed according to manufactures instruction, onto prepared specimens(original resin base plate, rough resin base plate, stippled metal plate, mesh metal plate ) 75mm long and 25m wide. And then, the peel test was performed by instron. The results were as follows : 1. The bonding strength of Mollosil was stronger than that of Molloplast B except the specimen of stippled metal plate. 2. The tensile strength of Mollosil was weaker than that of Molloplast Bas tearing of Mollosil was occured in the peel test. 3. Mesh metal plate had the highest bonding strength in the case of Molloplast B and Mollosil. But stippled metal plate have high bonding strength in the case of Molloplast B and have the lowest bonding strength in the case of Mollosil. 4. The bonding strength of rough resin base plate was stronger than that of original resin base plate in the case of Molloplast B and Mollosil. 5. The bonding strength of metal plates was stronger than that of resin base plates in the case of Molloplast B and Mollosil except the case of bonding strength between the stippled metal plate and Mollosil. 6. It seems that the Increase of surface and retention form of metal plate and resin base plate produces higher physical bonding strength.

  • PDF

Chip-to-chip Bonding with Polymeric Insulators (고분자 절연체를 이용한 칩투칩 본딩)

  • Ye Jin Oh;Seongwoo Jeon;Jin Su Shin;Kee-Youn Yoo;Hyunsik Yoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.31 no.3
    • /
    • pp.87-90
    • /
    • 2024
  • Currently, when oxides are used as insulators in hybrid bonding for 3D integration, they are prone to delamination due to their surface characteristics, and the RC delay value due to the resistance of the metal and the capacitance of the insulator increases as the wiring of the semiconductor chip becomes longer. To solve these problems, we studied the optimization of the conditions of the polymer insulator bonding method for hybrid bonding. To check the possibility of the de-wetting method, we coated a polymer film on the existing micro pillar and conducted hot-press bonding to remove the polymer between the metals. Through this study, it is expected that the introduction of polymers as insulators in hybrid bonding and fine-pitch metal bonding will improve signal transmission speed by reducing RC delay. It is also expected to be commercialized in the future to increase the number of I/O terminals by applying it to hybrid bonding.

THE EFFECTS OF SURFACE CONTAMINATION ON THE SHEAR BOND STRENGTH OF COMPOMER

  • Heo, Jeong-Moo;Lee, Su-Jong;Im, Mi-Kyung
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.577-577
    • /
    • 2001
  • The lastest concepts in bonding are "total etch", in which both enamel and dentin are etched with an acid to remove the smear layers, and "wet dentin" in which the dentin is not blown dry but left moist before application of the bonding primer. Ideally, the application of a bonding agent to tooth structure should be insensitive to minor contamination from oral fluids. Clinically contaminations such as saliva, gingival fluid, blood and handpiece lubricant are often encountered by dentists during preparation of a restoration. The aim of this study was to evaluate the effect of contamination by hem-ostatic agents on shear bond strength of compomer restorations. One hundred and ten extracted human maxillary and mandibular molar teeth were collected. The teeth were cleaned from soft tissue remnant and debris and stored in physiologic solution until they were used. Small flat area on dentin of the buccal surface were wet ground serially with 400, 800 and 1200 abrasive paper on automatic polishing machine. The teeth were randomly divided into 11 groups. Each group was conditioned as follows: Group 1 : Dentin surface was not etched and not contaminated by hemostatic agents. Group2 : Dentin surface was not etched but was contaminated by Astringedent (Ultradent product Inc., Utah, U.S.A.). Group3 : Dentin surface was not etched but was contaminated by Bosmin (Jeil Phann, Korea.). Group4 : Dentin surface was not etched but was contaminated by Epri-dent (Epr Industries, NJ, U.S.A.). Group5: Dentin surface was etched and not contaminated by hemostatic agents. Group 6 : Dentin surface was etched and contaminated by Astringedent. Group7 : Dentin surface was etched and contaminated by Bosmin. Group8 : Dentin surface was etched and contaminated by Epri-dent. Group9 : Dentin surface was contaminated by Astringedent. The contaminated surface was rinsed by water and dried by compressed air. Group10 : Dentin surface was contaminated by Bosmin. The contaminated surface was rinsed by water aud dried by compresfed air. Group 11 : Dentin surface was contaminated by Epri-dent. The contaminated surface was rinsed by water and dried by compresfed air. After surface conditioning, F2000 was applicated on the conditoned dentin surface. The teeth were thermocycled in distilled water at $5^{\circ}C\;and\;55^{\circ}C$ for 1000 cycles. The samples were placed on the binder with the bonded compomer-dentin interface parallel to the lmife-edge shearing rod of the Universal testing machine(Zwick 020, Germany) running at a cross head speed of 1.0mmimin. There were no significant differences in shear bond strength between groups 1 and group 3 and 4, but group 2 showed significant decrease in shear bond strength compared with group 1. There were no significant differences in shear bond strength between group 5 and group 7 and 8, but group 6 showed significant decrease in shear bond strength compared with group 5. There were no significant differences in shear bond strength between group 5 and group 9, 10 and 11.

  • PDF

Comparison of bond strength between denture base resin and reline resin (의치상 레진과 이장 레진 간의 결합강도 비교)

  • Geum, Young-Hee;Kim, Busob
    • Journal of Technologic Dentistry
    • /
    • v.39 no.3
    • /
    • pp.161-167
    • /
    • 2017
  • Purpose: We compare the bond strength of heat-cured PMMA of Lucitone 199 and QC-20 and Tokuyama Rebase Resin of self-cured resin, which are widely used and well accepted in clinical practice. In order to test the mechanical bonding and chemical bonding, we will compare the bond strength between EstheShot Bright, Smiletone, Repair and Rebase resins. Methods: The denture base resin used in this study was PMMA heat-cured QC-20 and Lucitone 199, polyamide resin EstheShot Bright, Smiletone. And Two types of self-curing Rapid Repair and Tokuyama Rebase were used as resection resins. To measure the bond strength, the denture specimens were fabricated in the size of $10{\times}64{\times}3.5mm$ as instructed by the manufacturer. A surface treatment agent was applied to the cut surfaces of each denture specimen, and the specimens were placed in a preformed silicone mold, and autoclaved excimer resins were prepared. The bending strength of the fabricated specimens was measured using a universal testing machine (STM-5, United Calibration Co., U.S.A.) to measure the three-point bending strength. Results: In both polycarbonate and polyacetal resin, a special resin surface treatment agent showed higher bonding strength than the resin surface treatment agent(p<0.05). Regardless of the type of surface treatment, polycarbonate showed higher bond strength than polyacetal resin(p<0.05). Conclusion: It is considered desirable to use a special surface treating agent for the thermoplastic denture base resin such as polycarbonate and polyacetal resin.

Selection of all ceramic crown (완전 도재관의 선택)

  • Lee, Seung-Kyu
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.24 no.2
    • /
    • pp.122-133
    • /
    • 2015
  • The requirements for the successful treatment of all-ceramic restorations are not so different from the ones of conventional restorations. "The provisional restoration followed by an adequate tooth reduction" and "the accurately fitting prostheses with corresponding to final impression" can be the examples of them. Nevertheless, the one which all-ceramic restorations are distinguished from conventional restorations is the additional procedure of so called "bonding". In addition to the application of resin cement between "inner surface of restoration and outer surface of abutment", bonding technology can be also applied to the treatment process of "Post and Core" in particular if the abutments are non-vital teeth. Core build-up for all-ceramic crown is conducted with fiber post and tooth colored composite by considering the properties of the restorations transmitting light. We know well that a vital abutment is easier than a non-vital one to get the targeted goals for clinical success in connection with esthetics and structure. The creation of "Post and Core" with bonding technique is a decisive factor for a long-term success if the abutment is non-vital tooth with dentinal collapse. I would like to share my clinical experience about "post & core build-up and all-ceramic restoration bonding" out of several success strategies of all-ceramic crown with this review article.

Effects of DC Substrate Bias Power Sources and Reactant Gas Ratio on Synthesis and Tribological Properties of Ternary B-C-N Coatings (기판 바이어스 DC 전원의 종류와 반응가스 분압비가 3성분계 B-C-N 코팅막의 합성과 마찰 특성에 미치는 영향)

  • Jeong, Da-Woon;Kim, Doo-In;Kim, Kwang-Ho
    • Journal of Surface Science and Engineering
    • /
    • v.44 no.2
    • /
    • pp.60-67
    • /
    • 2011
  • Ternary B-C-N coatings were deposited on Si(100) wafer substrate from $B_4C$ target by RF magnetron sputtering technique in $Ar+N_2+CH_4$ gas mixture. In this work, the effect of reactant gas ratio, $CH_4/(N_2+CH_4)$ on the composition, kinds and amounts of bonding states comprising B-C-N coatings were investigated using two different bias power sources of continuous and unipolar DCs. In addition, the tribological properties of coatings were studied with the composition and bonding state of coating. It was found that the substrate bias power had an effect on chemical composition, and all of the obtained coatings were nearly amorphous. Main bonding states of coatings were revealed from FTIR analyses to be h-BN, C-C, C-N, and B-C. The amount of C-C bonging mainly increased with increase of the reactant gas ratio. From our studies, both C-C and h-BN bonding states improved the tribological properties but B-C one was found to be harmful on those. The best coating from tribological points of view was found to be $BC_{1.9}N_{2.3}$ composition.

Thermal Cycle Reliabilties and Cracking Characteristics of Electroplated Cr/Ni-P Coatings (전해 Cr/Ni-P 도금막의 열 사이클 신뢰성 및 균열거동 분석)

  • Lee, Jina;Son, Kirak;Lee, Kyu Hwan;Park, Young-Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.4
    • /
    • pp.133-140
    • /
    • 2019
  • The effects of thermal cycle conditions on the bonding strength and crack propagation behaviors in electroplated Cr/electroplated Ni-P coatings were systematically evaluated. 1st heat treatment was performed at 500℃ for 3 hours after electroplating Ni-P, and then, 2nd heat treatment was performed at 750℃ for 6 hours after electroplating Cr. The measured bonding strength by ASTM C633 were around 25.6 MPa before thermal cycling, while it increased to 47.6 MPa, after 1,000 cycles. Increasing thermal cycles led to dominant fail mode with cohesive failure inside adhesive, which seemed to be closely related to the increasing bonding strength possibly not only due to higher Cr surface roughness, but also to penetrated channeling crack density. Also, increasing density of penetrated channeling cracks in electroplating Cr layer led to slightly stronger bonding strength due to mechanical interlocking effects of adhesive inside channeling cracks.

Enhancement of Cu Wire Bondability by Increasing the Surface Roughness of Capillary (표면 요철이 발달된 캐필러리 적용에 따른 Cu 와이어의 본딩 특성)

  • Lee, Jong-Hyun;Kim, Ju-Hyung;Kang, Hong-Jeon;Kim, Hak-Bum;Moon, Jung-Tak;Riu, Doh-Hyung
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.12
    • /
    • pp.913-920
    • /
    • 2012
  • In spite of some problems in processability and bondability, Au wires in the microelectronics industry are gradually being replaced by copper wires to reduce the cost of raw material. In this article, the effects of surface roughness enhanced capillaries on thermosonic Cu wire bonding were evaluated. The roughness-enhanced zirconia toughened alumina (ZTA) capillaries were fabricated via a thermal grooving technique. As a result, the shear bond strength of first bonds (ball bonds) bonded using the roughness-enhanced capillary was enhanced by 15% as compared with that of normal bonds due to more effective plastic deformation and flow of a Cu ball. In the pull-out test of second bonds (stitch bonds), processed at two limit conditions on combinations of process parameters, the bond strength of bonds formed using the roughness-enhanced capillary also resulted in values higher by 55.5% than that of normal bonds because of the increase in the bonding area, indicating the expansion of a processing window for Cu wire bonding. These results suggest that the adoption of roughness-enhanced capillaries is a promising approach for enhancing processability and bondability in Cu wire bonding.