• 제목/요약/키워드: bonded joint

검색결과 271건 처리시간 0.021초

전단보강근이 배근된 외부 보기둥 접합부에 정착된 헤드 철근의 스트럿-타이 모델 (Strut-And-Tie Model for Headed Bar Anchored in Exterior Beam-Column Joint with Transverse Reinforcement)

  • 천성철;홍성걸;오보환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.454-457
    • /
    • 2006
  • This study presents a strut-and-tie model for the development of headed bars in an exterior beam-column joint with transverse reinforcements. The tensile force of a headed bar is considered to be developed by head bearing together with bond along a bonded length as a partial embedment length. The model requires construction of struts with biaxially compressed nodal zones for head bearing and fan-shaped stress fields against neighboring nodal zones for bond stresses along the bonded length. Due to the existence of transverse reinforcements, the fan-shaped stress fields are divided into direct and indirect fan-shaped stress fields. A required development length and head size of a headed bar can be optimally designed by adjusting a proportion between a bond contribution and bearing contribution.

  • PDF

접착 및 기계적 프레스 접합부에서의 인장-박리 피로강도 평가 (Fatigue Strength Evaluation of Tensile-Peel Loaded Adhesively Bonded and Mechanical Pressed Joints)

  • 정강;김호경
    • 한국안전학회지
    • /
    • 제24권3호
    • /
    • pp.7-12
    • /
    • 2009
  • The tensile and fatigue experiments were conducted with tensile-peel specimens for investigating on strength of adhesively bonded and mechanical press joints of aluminum sheet used in the field of the automobile industry. The combining epoxy adhesive bonding and mechanical press joining exhibits an increase in joining force as a result of interaction between static forces of the two joining methods. The fatigue strength of pure adhesive joint was measured as 91% of that of the combination of adhesive bond and mechanical press joint, suggesting that the interaction between the bonding and mechanical joining was about 9%.

단일겹침 접착제 접합부의 응력분포와 강도평가 (Stress Distribution and Strength Evaluation of Adhesive Bonded Single-lap Joints)

  • 이중삼;임재규;김연직
    • Journal of Welding and Joining
    • /
    • 제19권3호
    • /
    • pp.342-347
    • /
    • 2001
  • Recently, adhesive-bonding technique is wifely used in manufacturing structures. Stress and strain analysis of joints are essential to design adhesive-bonded joints structure. The single-lap adhesive joint is the design dominating the range of adhesive joints. In this study, single-lap specimens with different joint dimensions were used for the tensile-shear test and finite element calculation in of order to investigate the effect of overlap length and adhesive-bonding thickness on adhesive strength and stress distribution of the joints. Consequently, it was found that overlap lap size and thickness can be important parameters of structure joints using adhesive bonding, which is effected on adhesive strength.

  • PDF

홍합 추출 접착액을 이용한 바이오 티슈의 접합능력 향상에 관한 연구 (Improvement of Bonding Performance for Biotissue using Marine Mussel Extract Adhesive)

  • 조병관
    • Journal of Biosystems Engineering
    • /
    • 제32권2호
    • /
    • pp.115-120
    • /
    • 2007
  • The adhesive performance of marine mussel extract was compared with that of the commercial medical adhesives for fastening biotissue (SIS) bandages. Joints bonded with mussel extract showed stronger strength than those bonded with other commercial adhesives. The bonding strength was much improved when the moisture in the Joint was reduced using superporous hydrogel regardless of curing time under humid condition ($37^{\circ}C$ and 91% relative humidity). Water inflow into the SIS joint seemed to degrade the performance of mussel extracts adhesive especially for the joints of short period of curing time. The strength of SIS joints coated with surgical sealant was well maintained after being exposed to water inflow.

펄스-에코법을 이용한 접착접합 시험편의 정량적 비파괴 평가 (Quantitative Nondestructive Evaluation of Bonded Joints utilizing Pulse-Echo Ultrasonic Test)

  • 오승규;황영택;이원
    • 한국정밀공학회지
    • /
    • 제20권3호
    • /
    • pp.157-164
    • /
    • 2003
  • The pulse-echo method is one of the most widely used ultrasonic techniques for application of nondestructive evaluation. Particularly, quantitative nondestructive evaluation of defects has been considered more important to assure the reliability and the safety of structure. Frequency energy in adhesive joints is based on the ultrasonic wave analysis. The attenuation coefficient upon wave amplitude and the frequency energy that is expressed in the term of wave pressure amplitude were utilized for the primary wave experiment. By means of a control experiment, it was confirmed that the variation of the frequency energy in adhesive joints depends on transition by stress variation. In this paper, the ultrasonic characteristics were measured for single lap joint and Double Cantilever Beam specimen with different fracture modes that was subjected to stress. Consequently, the data that was obtained from the adhesive specimen was analytically compared to the fracture mechanics parameter

Relaxation of Singular Stress in Adhesively Bonded Joint at High Temperature

  • Lee, Sang Soon
    • 반도체디스플레이기술학회지
    • /
    • 제17권1호
    • /
    • pp.35-39
    • /
    • 2018
  • This paper deals with the relaxation of singular stresses developed in an epoxy adhesive at high temperature. The interface stresses are analyzed using BEM. The adhesive employed in this study is an epoxy which can be cured at room temperature. The adhesive is assumed to be linearly viscoelastic. First, the distribution of the interface stresses developed in the adhesive layer under the uniform tensile stress has been calculated. The singular stress has been observed near the interface corner. Such singular stresses near the interface corner may cause epoxy layer separated from adherent. Second, the interfacial thermal stress has been investigated. The uniform temperature rise can relieve the stress level developed in the adhesive layer under the external loading, which can be viewed as an advantage of thermal loading. It is also obvious that temperature rise reduces the bonding strength of the adhesive layer. Experimental evaluation is required to assess a trade-off between the advantageous and deleterious effects of temperature.

복합재-알루미늄 이종재료 하이브리드 체결부 강도 특성에 관한 연구 (Strength of Composite-to-Aluminum Bonding and Bolting Hybrid Joints)

  • 정재우;김태환;권진희;최진호
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 추계학술발표대회 논문집
    • /
    • pp.57-60
    • /
    • 2005
  • Composite-to-aluminum joins were tested to get failure loads and modes for three types of joins; adhesive bonding, bolt fastening, and adhesive-bolt hybrid joining. Film type adhesive FM73 and paste type adhesive Cytec EA9394S were used for aluminum and composite bonding to make a double-lap joint. A digital microscope camcorder was used to monitor the failure initiation and propagation. It was found that the hybrid joining is an effective method to strengthen the joint when the mechanical fastening is stronger than the bonding as in the case of using the paste type adhesive. On the contrary, when the strength of the bolted joint is lower than the strength of the bonded joint as in the joint with the film type adhesive, the bolt joining contribute little to the hybrid joint strength.

  • PDF

단일겹치기이음시험을 이용한 합금화용융아연코팅강판의 코팅층 접합강도 평가 (Estimations of the Adhesion Strength of Galvannealed Coatings on Coated Sheet Using Single Lap-Shear Test)

  • 이정민;이찬주;고대철;이선봉;김병민
    • 대한기계학회논문집A
    • /
    • 제33권6호
    • /
    • pp.560-567
    • /
    • 2009
  • This paper was designed to estimate the adhesion strength of galvannealed coatings on steel sheets. The adhesion strength were evaluated using single lap - shear tests where the lap joint was bonded by structural adhesive. Tests were performed for overlap length of 5mm, 10mm and 15 mm and three directions (0, 45, 90) of steel sheets used as the adherend of the overlap joint. After the tests, FE simulations of the single lap-shear test were also carried out to observe the stress distribution in the interface between the adhesive and the coated sheet. The results showed that the joint failure loads obtained from the tensile tests of bonded single lap-joints were the same, regardless of overlap lengths and directions of steel sheets. Also, the failure of galvannealed coatings greatly depended on shear stress distribution in the interface and the value was about 30MPa.