• Title/Summary/Keyword: boiler system

Search Result 581, Processing Time 0.022 seconds

A development of multi-step neural network predictive controller (다단 신경회로망 예측제어기 개발)

  • 이권순
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.8
    • /
    • pp.68-74
    • /
    • 1998
  • The neural network predictiv econtroller (NNPC) is proposed for the attempt to mimic the function of brain that forecasts the future. It consists of two loops, one is for the prediction of output (NNP:neural network predictor) and the other one is for control the plant(NNC: neural network controller). The output of NNC makes the control input of plant, which is followed by the variation of both plant error and predictin error. The NNP forecasts the future output based upon the current control input and the estimated control output. The input and the output data of a system and a new method using evolution strategy are used to train the NNP. A two-step NNPC is applied to control the temeprature in boiler systems. It was compared with PI controller and auto-tuning PID controller. The computer simulaton and experimental results show that the proposed method has better performances than the other method.

  • PDF

A study on the Thermal Design of the Compact Type Small Fresh Water Generator (콤팩트형 소형 담수화장치의 열설계에 관한 연구)

  • 김성규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.3
    • /
    • pp.311-319
    • /
    • 1999
  • In Korea accelerated industry development and urbanization during the last three decades have led serious water pollution problems in many parts of the nation. Especially in the regions of west and south coast have low fresh water in the dry season of spring and summer. In the place isolated from land it is important to secure the fresh water for drinking and general service. This study is concerned on the thermal system design to develop low-pressure evaporation type fresh water gen-erator of capacity 1 ton/day using the heat source of non-operating boiler in the season of spring and summer. The results obtained from this study are as follows. the water quantitieds generated from experi-mental evaporator showed good coincidence with the calculated values. The maximum production quantity was 1.38ton/day at pressure 40mmHg abs. and temperature $80^{\circ}C$.

  • PDF

Particulate Two-Phase Flow Analysis for Fouling Prediction(I)-Design of Hot Wind Tunnel and Its Performance Experiment- (파울링 예측을 위한 가스-입자 이상 유동 해석(1)-고온 풍동 설계 및 성능실험-)

  • Ha, Man-Yeong;Lee, Dae-Rae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.11
    • /
    • pp.3695-3705
    • /
    • 1996
  • We designed the hot wind tunnel to reproduce the conditions of utility boiler and carried out its performance test, in order to investigate the particulate two-phase flow behaviour, the fouling and heat transfer characteristics to the heat exchanger. The hot wind tunnel introduces the control system to control the temperature in the test section. The particle is injected into the hot gas stream. The fouling probe (cylindrical tube) is positioned normal to the particulate gas-particle two-phase flow and cooled by the air. The temperature of gas and cooling air, and temperature in the fouling probe are measured as a function of time, giving the local and averaged heat transfer and fouling factor. The shape of particulate deposition adhered to the fouling probe is also observed.

A Study on the Selection of Maxium Plant Efficiency through the Performance Test in Snper-Critical Power Plant (초임계압형 화력발전소의 성능시험을 통한 최고효율점 선정에 관한 연구)

  • Kwon, Y.S.;Suh, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.402-407
    • /
    • 2003
  • The main reason to select the maxium plant efficiency through the performance test in fossil power plant is to increase the efficiency of power plant as well as saving energy collated with the policy of government. This study is aimed at unerstanding the variantion trend of efficiency and analyzing the efficiency of boiler and turbine through each of the performance test. Ultimately, the maxium efficiency of power plant will be presented in super-critical pressure type power plant.

  • PDF

A Study on the High-Frequency Resonant Inverter System for Indirect Induction Heating (간접유도가열용 고주파 공진형 인버터 시스템에 관한 연구)

  • Kwon H. M.;Shin D. C.;Kim K. H.;Kim Y. J.
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.322-325
    • /
    • 2002
  • In this paper are described the indirect induction heated boiler and induction heated hot air producer using the voltage-fed series resonant high-frequency inverter which can operate in the frequency range from 20kHz to 50kHz. A specially designed induction heater, which is composed of laminated stainless assembly with many tiny holes and interconnected spot welding points between stainless plates, is inserted Into the ceramic type vessel with external working coil. This working coil is connected to the inverter and turbulence fluid through this induction heater to moving fluid generates in the vessel. The operating performances of this unique appliance in next generation and its effectiveness are evaluated and discussed from a practical point of view.

  • PDF

Application of Impinging Jet Injectors to Boiler Spray System : Possibility and Effects (보일러용 연료분사 시스템의 충돌분무 시스템화의 가능성 진단 및 파급효과 분석)

  • Park, Jong-Hoon;Jung, Ki-Hoon;Yoon, Young-Bin;Hwang, Sang-Seun
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.460-465
    • /
    • 1999
  • 액체 로켓용 충돌분사형 인젝터는 구조가 매우 간단하면서 고유량의 연료를 분사시킬 수 있기 때문에 여러 엔진에 응용된 바 있다. 본 연구에서는 이러한 인젝터의 특성을 산업용 보일러에 적용하기 위한 기초 실험 및 수치 계산을 수행하였다. 충돌분사 노즐로부터 형성되는 분무의 분포 특성을 실험적으로 측정하였고 이를 실제 조건에 모사하기 위해 수치 계산을 하여, 두 결과를 비교하여보았다. 이로부터 보일러의 효율과 공해물질 저감에 영향을 가져오는 액적의 미립화 특성을 향상시킬수 있는 연료 분사 조건을 제시하였다.

  • PDF

Multi-Optimization Study of a Boiler System Using Immune Algorithms (면역 알고리즘을 이용한 보일러 시스템의 다목적 성능 최적화 연구)

  • 김동화;박진일
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.05a
    • /
    • pp.177-181
    • /
    • 2003
  • PID(Proportional-Integral-Derivative)제어기는 제어악고리즘의 단순성과 실 현장에서의 강인성 등으로 산업용 보일러의 제어시스템서 주로 이용되어 왔다. 그러나 다중 루프를 가진 보일러 시스템에서는 루프간의 상호 간섭 영향 등으로 부하 변화에 따라 요구되는 증기(steam)압력, 증기 유량(steam flow)변화 등을 동시에 만족하도록 급수 유량, 연교 유량, 공기 유량 등을 PlH제어기만으로 제어하는 것은 어렵다. 본 연구에서는 보일러 시스템의 다목적 성능 최적화에 각각의 적합도 함수 $f_{a}$ , $f_{b}$, $f_{c}$를 정의하고 면역 알고리즘을 이용해 최적화를 구하고 그 결과에 대한 특성과 유효성을 검토하였다.다.다.

  • PDF

Development of Preheating Module for Domestic Heating Facility, Using PCM(Phase Change Material) Thermal Storage Equipment (상변화물질(PCM)을 이용한 가정용 보일러의 잠열축열식 예열모듈 개발)

  • Son, Chul-Min;Kim, Tae-Wook;Na, Kyu-Dong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.12 no.3
    • /
    • pp.163-169
    • /
    • 2009
  • A preheating module for domestic heating facility will increase a energy efficiency. That collects the wasted heat of exhaust gas and saves the energy. So a heating load is decreased because of a preheating that has a heating energy. Using of a preheating module, a boiler can reduce frequent operation of a burner. So it is increased persistence, decreased discharging noxious gases. Therefore we will intend to develop a heating facility that is a convenient system for the saving energy.

  • PDF

Phenomenological model based failure detection of the boiler drum level control system of a power plant (현상적 모델에 기초한 보일러 플랜트 드럼 수위제어기의 고장감지)

  • Kim, J.K.;Chang, T.G.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.84-86
    • /
    • 2001
  • 본 연구에서는 플랜트의 계측신호로 부터 특징 패턴 파형들을 감지하고 패턴감지 정보로부터 플랜트의 운전상황 및 고장을 알아내도록 하는 새로운 기법을 제시하고, 이러한 기법의 실현에 필요한 신호처리 기초 연구를 수행하였다. 또한 보령화력 1.2호기 500MW급 드럼형 보일러및 제어 시스템을 대상으로 보일러 플랜트의 dynamics 모델링과 운전 시뮬레이션을 통하여 여러 운전 패턴및 고장 상황을 발생시켜 고장감지 앨고리즘들의 개발 및 시험과정에 적용하였다. 본 연구에서 수행한 보일러 및 보일러 제어계통에 대한 모델링 및 시뮬레이션은 실제 수행한 발전소 시험 데이터와 비교할 때 높은 일치도를 보이는 결과를 보였다.

  • PDF

Analysis of energy consumption of office building by thermal resistance-capacitance method (열저항-열용량법에 의한 사무실용 건물의 소비에너지 해석)

  • Lee, C.S.;Choi, Y.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.1
    • /
    • pp.1-13
    • /
    • 1997
  • This paper reports the dynamic analysis of energy consumption for an office building by heat resistance-capacitance method. If a building is divided into several wall components and the wall components is replaced by one thermal capacitance and several thermal resistances, the building becomes an electric circuit. By solving the simultaneous equations of the circuit, the dynamic heat transfer characteristics and the energy consumption rate of the building were predicted. Accuracy of modified BIN method was evaluated by the present resistance-capacitance method. The result shows that modified BIN method overpredicts the heating load of the office building 15%. Annual energy consumptions of equipments(fan, boiler, chiller) for various ventilating control system(CAV, VAV, FCU+VAV, FCU+CAV) were compared. FCU+CAV shows the minimum annual energy consumption.

  • PDF