• Title/Summary/Keyword: body-fix

Search Result 52, Processing Time 0.036 seconds

Evaluation on Usefulness of Applying Body-fix to Four Dimensional Radiation Therapy (4차원 방사선 치료시 Body Fix의 유용성 평가)

  • Kim, Young-Jae;Jang, Young-Ill;Ji, Yeon-Sang;Han, Jae-Bok;Choi, Nam-Gil;Jang, Seong-Joo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.10
    • /
    • pp.419-426
    • /
    • 2013
  • This study investigates the usefulness of body fix in 4DRT on Liver cancer trying to find tumor tissue's volume and located variations, absorbed dose on tumor and normal tissues. Test subjects 23 patients were agreed these test. These patient's have a 4 dimensional CT scan. We make an acquisition on patients CT image by two types -put on the body fix or not-. Average tumor volume reduced by 0.17% on GTV and 3.2% on CTV and PTV. Tumor's variation reduces 29.8%(anterior and posterior, AP) and 5.31% (upper and lower, UL). The absorbed tumor doses under put on the body fix was a little higher(1.3%) than other. Normal tissues'(normal liver, stomach, Rt. kidney, spinal cord) absorbed dose could be reduced approximately 5%. Therefore, using body fix on 4DRT for liver cancer patient is considered effectively.

Evaluation on Usefulness of Applying Body-fix to Liver Cancer Patient in Tomotherapy (간암환자의 토모치료시 Body-fix 사용유무에 따른 유용성 평가)

  • Oh, Byeong-Cheon;Choi, Tae-Gu;Kim, Gi-Chul
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.11-18
    • /
    • 2010
  • Purpose: In every time radiation therapy set up errors occur because internal anatomical organs move due to breathing and change of patient's position. These errors may affect the change of dose distribution between target area and normal structure. This study investigates the usefulness of body-fix in clinical treatment. Materials and Methods: Among 55~60 aged male patients who has hepatocellular carcinoma in area of liver's couinaud classification, we chose 10 patients and divided two groups by using body-fix or not. When applying body-fix, we maintained a vacuum of 80 mbar pressure by using vacuum pump (Medical intelligence, Germany). Patients had free breathing with supine position. After working to fuse and consist MV-CT (megavoltage computed tomography) with KV-CT (kilovoltage computed tomography) obtained by 5 times treatments, we compared and analyzed set up errors occurred to (Right to Left, RL) of X axis, (Anterioposterio, AP) of Z axis, (Cranicoudal, CC) of Y axis. Results: Average Set up errors through image fusion showed that group A moved $0.3{\pm}1.1\;mm$ (Cranicoudal, CC), $-1.1{\pm}0.7\;mm$ (Right to Left, RL), $-0.2{\pm}0.7\;mm$ (Anterioposterio, AP) and group B moved $0.62{\pm}1.94\;mm$ (Cranicoudal, CC), $-3.62{\pm}1.5\;mm$ (Right to Left, RL), $-0.22{\pm}1.2\;mm$ (Anterioposterio, AP). Deviations of X, Y and Z axis directions by applying body-fix indicated that maximum X axis was 5.5 mm, Y axis was 19.8 mm and Z axis was 3.2 mm. In relation to analysis of error directions, consistency doesn't exist for every patient but by using body-fix showed that the result of stable aspect in spite of changes of everyday's patient position and breathing. Conclusion: Using body-fix for liver cancer patient is considered effectively for tomotherapy. Because deviations between group A and B exist but they were stable and regular.

  • PDF

Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program in AEC Mode and Fix Mode for the whole spine antero-posterior radiography (전 척추 전.후 방향 검사 시 AEC Mode와 Fix Mode에서 PC-Based Monte Carlo Program을 이용한 장기선량 및 유효선량 평가)

  • Kim, Jeong Jin;Jang, Seong Won;Park, Jang Heum;Lee, Kwan Seob;Ha, Dong Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.23-31
    • /
    • 2012
  • There are AEC mode and fix mode to exposure when the whole spine antero-posterior radiography is done by using DR equipment. This study compared the utility of fix mode to AEC mode, by evaluating organ dose and effective dose and by examining the quality of radiographic image. GE DEFINIUM 8000 and ART-200X Rando Phantom manufactured by Flukebiometical were used for this study. The Rando phantom was set in front of wall detector of X-rays equipment. AEC mode was set at 80kVp and Fix mode was set at 80kVp, 25mAs, 32mAs, 40mAs, and 50mAs. Whole spine AP image were aquired by combining C, T-L and L-S spine images obtained through 3 exposures. When obtaining C, T-L and L-S spine images, were checked for Air kerma (mGy) value calculated by UNFORS Xi meter attached at the phantom surface of center of radiation field. The effective and organ doses were compared by PCXMC program (PC-Based Monte Carlo Program). The quality of obtained radiographic image was evaluated visually by 3 radiologists using resolution chart. When the effective doses was calculated based on tissue weighting factor of ICRP-103, 1.278mSv was measured by AEC mode, and Fix mode measured 0.405mSv at 25mAs, 0.518mSv at 32mAs, 0.649mSv at 40mAs, and 0.810mSv at 50mAS. In addition, the organ dose measured with esposure at 25mAs by Fix mode was almost equivalent to the organ dose by AEC mode, at the esophagus, thyroid, oral mucosa, salivaly glands located at the cervical spine part, while the organ dose by Fix mode was in general lower than the organ dose by AEC mode at the other organs. When Fix mode at 32mAs, 40mAs, and 50mAs was compared to AEC mode for organ dose in 26 organs, AEC mode had higher measurement in 21 organs but not for than brain, trachea, thyroid, oral mucosa, and salivaly glands which are located at the cervical spine part. The image quality evaluated by resolution test chart was much higher with AEC mode than the quality with Fix mode at all exposure conditions. However, while the image quality of cervical spine exposured at 50mAs by Fix mode was lower than the quality of AEC mode, thoraco-lumbar spine and lumbo-sacral spine were calculated and the quality was similar to AEC mode. Scoliosis occurs mainly at thoraco-lumbar and lumbo-sacral spine, not at cervical spine. Compared to AEC mode, Using the appropriate protocol (80kVp, 50mAs) of fix mode for whole spine AP radiography was thought to be useful because the image quality of the thoraco-lumar and lumbo-sacral spine was similar on AEC mode, Also organ and effective doses can be decreased with Fix mode. Therefore, It is considered that fix mode can be used properly with AEC mode for whole spine AP radiography when considering patient's body posture.

  • PDF

Development of Jeggings Pattern Considering Body Fit -Focus on 20-24 Year Old Females- (신체적합성을 고려한 제깅스(Jeggings) 패턴 개발 -20~24세 여성을 중심으로-)

  • Lee, Kyu-Sun;Choi, Jeong-Wook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.38 no.5
    • /
    • pp.675-689
    • /
    • 2014
  • This study developed an ideal jeggings pattern with an improved body fit for 20-24 year old females. The results of the study are as follows. First, samples for wearing test were made using jegging patterns from three manufacturers; subsequently, one pattern with a relatively outstanding body fit was selected from the first test. The selected pattern suggested a tight knee, belly, and crotch, high front waist line, and low back waist line. The side lines were also lean to the front; consequently, the front hip width was extended for 0.5cm for more space around the belly and the extended front knee part for 0.2cm to increase moving suitability to fix the leaning side lines. A 1cm front waist line was extended for 0.5cm to fix it lower; in addition, the back waist line 3.0cm was extended for 0.5cm to heighten it. The crotch width was also extended for 0.5cm to add more space. The second wearing test for the fixed forms were evaluated for their outstanding features in appearance as well as moving functions that were proposed as final jeggings forms. The results of the study suggested a jeggings pattern with a better body fit using manufacturer patterns that can be used as basic data for pant patterns with better fitting using various stretch fabrics.

Technical Development using High Strength Steel of mP Type on Automobile Parts (TRIP형 고장력강판의 부품적용 기술개발)

  • 류성지;이상제;이규현;이문용
    • Journal of Welding and Joining
    • /
    • v.20 no.3
    • /
    • pp.46-53
    • /
    • 2002
  • The expolitation of substitute material and new manufacturing technology of the automobile body panel for next generation cars have been steadily professed by advanced automobile companies. High strength steel of TRIP (Transformation of Induced Plasticity) type is developed in response to demands about crash safety and high strength of automobile. In this study, basic technologies can fix up problems occurring on the mass production and applied to the other forming methods will be prepared through rasping a property of TRIP material.

Aesthetic Characteristics of Grecian Style (그리스 스타일의 미적 특성)

  • Ham, Youn-Ja
    • Fashion & Textile Research Journal
    • /
    • v.9 no.6
    • /
    • pp.595-602
    • /
    • 2007
  • This study examined the aesthetic characteristics of Grecian style which is being considered as the representative classic of Western fashion and the transformations of those Grecian styles on the fashion of the twentieth century. This study used positive research method using literatures on art history and clothing history, fashion related publications, and magazines and websites to understand the trend of fashion designer's collections. The study results are as follows. The aesthetic characteristics of Grecian style was considered to be the ideal beauty combined with symmetry, the functional beauty combined with non-construction, and the sensual beauty combined with natural body. The ideal beauty combined with symmetry appears as a style that shows idealistic proportion of a body emphasizing high-waist based on the golden ratio and the body as a whole rather than details. The functional beauty combined with non-construction appears as perfect recreation a body in its original and natural form. The clothing takes a form that does not have any structural design and has simplified cutting and sewing. It uses pins and strings to fix up the form of clothing which is flexible and naturally draped. The sensual beauty combined with natural body is found in natural silhouette dress alluding naked body in connection with Rousseau' naturalism in neoclassic period. Throughout the twentieth century, the desire for Grecian style was conveyed by a single detail or through an array of allusive effects.

Kinematic Analysis of the Multi-Link Five-Point Suspension System in Point Coordinates

  • Attia, Hazem-Ali
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.8
    • /
    • pp.1133-1139
    • /
    • 2003
  • In this paper, a numerical algorithm for the kinematic analysis of a multi-link five-point suspension system is presented. The kinematic analysis is carried out in terms of the rectangular Cartesian coordinates of some defined points in the links and at the joints. Geometric constraints are introduced to fix the relative positions between the points belonging to the same rigid body. Position, velocity and acceleration analyses are carried out. The presented formulation in terms or this system of coordinates is simple and involves only elementary mathematics. The results of the kinematic analysis are presented and discussed.

Delayed Foreign Body Reaction around the Absorbable Implants in Facial Bone Fracture: A Case Report (안면부 골절에 사용된 흡수성 보형물의 지연성 이물반응: 증례보고)

  • Suh, Yong-Hoon;Kim, Young-Joon
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.875-878
    • /
    • 2011
  • Purpose: Absorbable implants are frequently used to fix facial bone fractures, because they are radiolucent and compatible with magnetic resonance imaging (MRI). Despite their increasing usage, however, there have been few reports about their long-term side-effects. In this paper, a case in which absorbable implants led to a foreign body reaction 17 months after their insertion is presented. Methods: A previously healthy 19-year-old male fell from a flight of stairs and visited the authors' hospital with right periorbital pain. Zygomaticomaxillary fracture involving right orbital floor was detected via a facial bone computed tomography (CT). Internal fixation with absorbable implants was followed by open reduction. 17 months after the surgery, the patient complained of localized periorbital swelling. Removal of the granulomatous lesion including the absorbable implants along with their biopsy and culture was performed. Results: The granulomatous lesion around the implants was firm and extended into the maxillary sinus. The histologic finding showed a microabscess with a foreign body reaction. Methicillin-sensitive Staphylococcus aureus growth was confirmed in the culture. No definite abnormal symptoms ensued after the complete removal. Conclusion: A microabscess-forming granulomatous lesion around the absorbable implant can cause delayed symptomatic foreign body reaction despite its rare occurrence. Complete removal of the lesion including implants is expected to have a successful outcome if it is encountered.

An automatic motorized feeder pipe inspection robot (자율 주행형 급수 배관 검사)

  • Choi, Chang-Hwan;Jeon, Pung-Woo;Choi, Yong-Je;Jeong, Seung-Ho;Kim, Seung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.816-821
    • /
    • 2004
  • The outlet feeder pipe thinning in a PHWR (Pressured Heavy Water Reactor) is caused by high pressure steam flow inside the pipe, which is a well known degradation mechanism called FAC (Flow Assisted Corrosion). In order to monitor the degradation, the thickness of the outlet bends closed to the exit of the pressure tube should be measured and analyzed at every official overhaul. This paper develops an automatic feeder pipe inspection system that can minimize the irradiation dose by automating the measurement process. The robot can move by itself on the feeder pipe by using an inch worm mechanism, which is constructed by two gripper bodies that can fix their body on the pipe and one extendable and retractable body connected the two gripper bodies to move forward and backward.

  • PDF

A Study on Versatile Chair Design Reflecting Users' Behavior

  • Kim, Gwang-Hee;Choi, Kyung-Ran;Sung, Yun-Jung
    • Journal of the Korea Furniture Society
    • /
    • v.22 no.3
    • /
    • pp.151-159
    • /
    • 2011
  • This study is to suggest versatile chair designs that are organically shaped to take individual orientation. This study intends to provide design method to ensure the face of the chair that contacts the body of its user is transformed flexibly to support the body. The movement of human body is not just a behavior but the ways and tools that reflexively express against external stimuli that are sensed and identified by the person. The versatile chair whose users' sitting position is fixed is made by covering the lump form with a piece of cloth ensuring that the content is firmly fixed and by placing the beads-woven wood fabric according to the shape. And then, it is covered with the external cover. The proposed versatile chair designs assume specific forms as follows: First, it is a versatile chair whose user's sitting position can fix. The organically-shaped form that can accept varying postures is made as a mass, which changes into different shapes when human body touches the form so that users can lie down or sit. Due to such transformation, body posture is determined and individual differences in shape changing are all acceptable. Second, it is a versatile chair that reflects the user's position in a fixed chair, where a cloth-wrapper feature is applied to the form a sifit wrapped postures so that a variety of body postures can be accepted. Finally, a versatile chair that reflects the user's position by changing the shape of is covered with forms so that it will be transformed and used in accordance with situations and chair shapes and reflect multiple shapes including round or square ones.

  • PDF