• Title/Summary/Keyword: body positioning

Search Result 129, Processing Time 0.028 seconds

Changes in Posterior Cerebral Artery Blood flow Velocity Following Head rotation and body Positioning (머리회전과 측정자세에 따른 뒤대뇌동맥의 혈류속도 변화)

  • Park, Min-Chull;Kim, Jong-Soon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.1
    • /
    • pp.115-120
    • /
    • 2015
  • PURPOSE: Vertebrobasilar insufficiency (VBI) should be carefully assessed in patient for whom manipulation of the cervical spine is to be undertaken. The purpose of this study was to investigate the changes in posterior cerebral artery blood flow velocity following head and body positioning by transcranial doppler ultrasonography (TCD) in healthy subjects. METHODS: Twenty two healthy female (mean age $20.77{\pm}1.30yrs.$) participants volunteered to participate in the study. None of the participants had a history of neck pain or headache within the last 6 months. To evaluate the cerebral blood flow, we measured the mean flow velocity of the posterior cerebral artery unilaterally (right side). The blood flow velocity was measured under 3 different head positions (in a neutral head position, ipsilateral head rotation and contralateral head rotation position) and 2 different body conditions (supine position and sitting position). RESULTS: The mean blood flow velocity of posterior cerebral artery was decreased in body positioning from supine to sitting (p<.05), but the decreased rate of blood flow velocity in posterior cerebral artery did not change significantly between ipsilateral head rotation and contralateral head rotation (p>.05). CONCLUSION: These result of our study show that body positioning (sitting and supine) affect the blood flow velocity in posterior cerebral artery.

Evaluation of Real-time Target Positioning Accuracy in Spinal Radiosurgery (척추방사선수술시 실시간 추적검사에 의한 병소목표점 위치변이 평가)

  • Lee, Dong Joon
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.290-294
    • /
    • 2013
  • Stereotactic Radiosurgery require high accuracy and precision of patient positioning and target localization. We evaluate the real time positioning accuracy of isocenter using optic guided patient positioning system, ExacTrac (BrainLab, Germany), during spinal radiosurgery procedure. The system is based on real time detect multiple body markers attached on the selected patient skin landmarks. And a custom designed patient positioning verification tool (PPVT) was used to check the patient alignment and correct the patient repositioning before radiosurgery. In this study, We investigate the selected 8 metastatic spinal tumor cases. All type of tumors commonly closed to thoracic spinal code. To evaluate the isocenter positioning, real time patient alignment and positioning monitoring was carried out for comparing the current 3-dimensional position of markers with those of an initial reference positions. For a selected patient case, we have check the isocenter positioning per every 20 millisecond for 45 seconds during spinal radiosurgery. In this study, real time average isocenter positioning translation were $0.07{\pm}0.17$ mm, $0.11{\pm}0.18$ mm, $0.13{\pm}0.26$ mm, and $0.20{\pm}0.37$ mm in the x (lateral), y (longitudinal), z (vertical) directions and mean spatial error, respectively. And body rotations were $0.14{\pm}0.07^{\circ}$, $0.11{\pm}0.07^{\circ}$, $0.03{\pm}0.04^{\circ}$ in longitudinal, lateral, table directions and mean body rotation $0.20{\pm}0.11^{\circ}$, respectively. In this study, the maximum mean deviation of real time isocenter positioning translation during spinal radiosurgery was acceptable accuracy clinically.

Motion Control of Two Welding Mobile Robot with Seam Tracking Sensor

  • Byuong-Oh;Jeon, Yang-Bae;Suh, Jin-Ho;Oh, Myung-Suk;Kim, Sang-bong
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.4 no.2
    • /
    • pp.30-38
    • /
    • 2003
  • This paper proposed PID controller for torch slider and PD controller for motor right wheel. to control the motion of two-wheeled welding mobile robot with seam tracking sensor touched on welding line. The motion control is realized in the view of keeping constant welding velocity and precise seam tracking even though the target welding line is on straight line or curved line. The position and direction of the body of the mottle robot are controlled by using signal errors between seam tracking sensor and body positioning sensor attached on the end of torch slider and body side of the mobile robot, respectively. In turning motion, the body and the torch slider are controlled by using the kinematic model related with two motions of body turning and torch sliding. The straight locomotion is controlled according to eleven control patterns obtained from displacements between two sensors of the seam tracking sensor and the body positioning sensor. The effectiveness is proven through the experimental results fur lattice type welding line. Through the experimental results, we can see that the position value of the electrode end point and the welding velocity are controlled almost constantly both in straight and turning locomotion.

The Importance of Positioning in Left Lateral Chest X-Ray Examination (흉부 왼쪽 엑스선검사 시 위치 잡기의 중요성)

  • Pyong-Kon Cho
    • Journal of radiological science and technology
    • /
    • v.46 no.4
    • /
    • pp.287-294
    • /
    • 2023
  • This study was conducted to ultimately reduce unnecessary radiation exposure by emphasizing the need and importance of correct positioning by examining the positioning relationship of anatomical structures in the human body and changes in X-ray images according to changes in patient positioning during the left lateral chest X-ray examination. This study investigated and analyzed previously published papers and books on the left lateral chest X-ray examination to find out the importance of positioning in the left lateral chest X-ray examination. To find out the importance of correct positioning in the left lateral chest X-ray, we compared three images of incorrectly positioned right thorax and left thorax rotated forward and the lower median surface of the body leaning against the image receptor. In the left lateral chest examination, a distorted image was obtained in which the shape of the anatomical structure observed in the image was changed according to the presence or absence of rotation of the patient and the inclination of the median visual surface. X-ray images with the most accurate and large amount of information were obtained from X-ray images with the correct positioning performed during left lateral chest X-ray examination. Therefore, It is believed that the left lateral chest X-ray examination will have beneficial effects such as providing accurate medical information, preventing misdiagnosis, reducing social costs, and ultimately reducing radiation exposure.

Error Assessment of Attitude Determination Using Wireless Internet-Based DGPS (무선인터넷기반의 DGPS를 이용한 동체의 자세결정 성능평가)

  • Lee Hong Shik;Lim Sam Sung;Park Jun Ku
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.23 no.2
    • /
    • pp.101-108
    • /
    • 2005
  • Inertial Navigation System has been used extensively to determine the position, velocity and attitude of the body. An INS is very expensive, however, heavy, power intensive, requires long setting times and the accuracy of the system is degraded as time passed due to the accumulated error. Global Positioning System(GPS) receivers can compensate for the Inertial Navigation System with the ability to provide both absolute position and attitude. This study describes a method to improve both the accuracy of a body positioning and the precision of an attitude determination using GPS antenna array. Existing attitude determination methods using low-cost GPS receivers focused on the relative vectors between the master and the slave antennas. Then the positioning of the master antenna is determined in meter-level because the single point positioning with pseudorange measurements is used. To obtain a better positioning accuracy of the body in this research, a wireless internet is used as an alternative data link for the real-time differential corrections and dual-frequency GPS receivers which is expected to be inexpensive was used. The numerical results show that this system has the centimeter level accuracy in positioning and the degree level accuracy in attitude.

The effect of the improperly scanned scan body images on the accuracy of virtual implant positioning in computer-aided design software

  • Park, Se-Won;Choi, Yong-Do;Lee, Du-Hyeong
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.3
    • /
    • pp.107-113
    • /
    • 2020
  • PURPOSE. The aim of this study was to examine the importance of the defect-free scanning of a scan body by assessing the accuracy of virtual implant positioning in computer-aided design (CAD) software when the scan body image is improperly scanned. MATERIALS AND METHODS. A scan body was digitized in a dentiform model using an intraoral scanner, and scanned images with differing levels of image deficiency were generated: 5%, 10%, and 15% deficiency in the flat or rounded area. Using a best-fit image matching algorithm on each of the deficient scan body images, corresponding virtual implants were created. The accuracy of the implant position was evaluated by comparing the linear and angular discrepancies between the actual and virtual positions of the implant. Kruskal-Wallis tests and Mann-Whitney U tests with Bonferroni correction were used to determine the statistical differences among the seven scanned image deficiency groups (α=.05). RESULTS. In general, the linear and angular discrepancies of the implant position in the software increased as the deficiency of the scan body images increased. A 15% scan body image deficiency generated larger discrepancies than deficiency of 5% and 10%. The difference of scan defect position, flat or rounded area, did not affect the accuracy of virtual implant orientation at 5% and 10% deficiency level, but did affect the accuracy at 15% deficiency level. CONCLUSION. Deficiencies in the scanned images of a scan body can decrease the accuracy of the implant positioning in CAD software when the defect is large, thus leading to the incorrect fabrication of implant prostheses.

Assessment of the Optic-guided Patient Positioning for Spinal Stereotactic Radiosurgery Using Novalis ExacTrac System (노발리스 ExacTrac system을 이용한 척추 정위 방사선수술 방법 평가)

  • 이동준;손문준;최광영;이기택;최찬영;황금철;황충진
    • Progress in Medical Physics
    • /
    • v.13 no.4
    • /
    • pp.218-223
    • /
    • 2002
  • Stereotactic radiosurgery for intracranial lesion is well established since the Lars Leksell first introduced radiosurgery concept in 1951 Its use in the treatment of spinal lesion has been limited by the availability of effective immobilization devices. The first clinical experience of the spinal stereotactic radiosurgery technique was reported by Hamilton AJ. in 1995. Recently, Optic-guided patient positioning technique for extracranial stereotactic radiosurgery was developed and reported. This study is for assess the target positioning accuracy of the optic guided patient positioning system Exactrac (BrainLab., Inc, Germany). We have designed phantom for assess the accuracy of spinal stereotactic radiosurgery The infrared reflective body markers attached to the relatively immobile part of the body and a series of 2 mm CT images was taken. The image sets were transferred to the planning computer. During the radiosurgery treatment, we measure the real-time display showing the positioning values from Exactrac computer. And we compare the isocenter deviation from irradiated center point of the film which was mounted on the lesion site of the phantom and pin hole site of that film. The accuracy of the ExacTrac system in positioning a target point shows enough for the clinical applications.

  • PDF

Three-Dimensional Location Tracking System for Automatic Landing of an Unmanned Helicopter (무인 헬기 자동 착륙을 위한 3차원 위치 추적 시스템)

  • Choo, Young-Yeol;Kang, Seong-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.6
    • /
    • pp.608-614
    • /
    • 2008
  • This paper describes a location tracking system to guide landing process of an Unmanned Helicopter(UMH) exploiting MIT Cricket nodes. For automatic landing of a UMH, a precise positioning system is indispensable. However, GPS(Global Positioning System) is inadequate for tracking the three dimensional position of a UMH because of large positioning errors. The Cricket systems use Time-Difference-of-Arrival(TDoA) method with ultrasonic and RF(Radio Frequency) signals to measure distances. They operate in passive mode in that a listener attached to a moving device receives distance signals from several beacons located at fixed points on ground. Inevitably, this passive type of implementation causes large disturbances in measuring distances between beacons and the listener due to wind blow from propeller and turbulence of UMH body. To cope with this problem, we proposed active type of implementation for positioning a UMH. In this implementation, a beacon is set up at UMH body and four listeners are located at ground area at least where the UMH will land. A pair of Ultrasonic and RF signals from the beacon arrives at several listeners to calculate the position of the UMH. The distance signals among listeners are synchronized with a counter value appended to each distance signals from the beacon.

Digital Positioning Control of Pneumatic Cylinder System with Elastic and Viscous Load (탄성 및 점성 부하시 공기압 실린더 시스템의 디지털 위치 제어)

  • 박명관;문영진;편창관
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.1
    • /
    • pp.137-144
    • /
    • 1998
  • For a model system consisted of four pneumatic cylinders with strokes of 10, 20, 40 and 80 mm, investigation was carried out experimentally and numerically about the reliability of system with elastic and viscous load. The elastic load affects the performance of each cylinder in cylinder series, and changes the time lag and the velocity of the piston which makes the positioning control rather difficult. Taking the effects of the elastic load into consideration, positioning can be carried out comparatively smoothly by only adjusting the driving timing. The effect of a viscous load reduces the vibration of each moving body in the cylinder series and also reduces the over-travelled distance which happens when several cylinders move at the same time. For reasons, a positioning with a viscous load can be relatively smoothly carried out even without the timing control.

  • PDF

Common positioning errors in panoramic radiography: A review

  • Rondon, Rafael Henrique Nunes;Pereira, Yamba Carla Lara;do Nascimento, Glauce Crivelaro
    • Imaging Science in Dentistry
    • /
    • v.44 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Professionals performing radiographic examinations are responsible for maintaining optimal image quality for accurate diagnoses. These professionals must competently execute techniques such as film manipulation and processing to minimize patient exposure to radiation. Improper performance by the professional and/or patient may result in a radiographic image of unsatisfactory quality that can also lead to a misdiagnosis and the development of an inadequate treatment plan. Currently, the most commonly performed extraoral examination is panoramic radiography. The invention of panoramic radiography has resulted in improvements in image quality with decreased exposure to radiation and at a low cost. However, this technique requires careful, accurate positioning of the patient's teeth and surrounding maxillofacial bone structure within the focal trough. Therefore, we reviewed the literature for the most common types of positioning errors in panoramic radiography to suggest the correct techniques. We would also discuss how to determine if the most common positioning errors occurred in panoramic radiography, such as in the positioning of the patient's head, tongue, chin, or body.