• 제목/요약/키워드: body impedance control

검색결과 41건 처리시간 0.034초

Electrochemical Behaviors of PEO-treated Ti-6Al-4V Alloy in Solution Containing Zn and Si Ions

  • Hwang, In-Jo;Choe, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.160-160
    • /
    • 2017
  • Commercially pure titanium (Cp-Ti) and Ti alloys (typically Ti-6Al-4V) display excellent corrosion resistance and biocompatibility. Although the chemical composition and topography are considered important, the mechanical properties of the material and the loading conditions in the host have, conventionally. Ti and its alloys are not bioactive. Therefore, they do not chemically bond to the bone, whereas they physically bond with bone tissue. The electrochemical deposition process provides an effective surface for biocompatibility because large surface area can be served to cell proliferation. Plasma electrolyte oxidation (PEO) enables control in the chemical composition, porous structure, and thickness of the TiO2 layer on Ti surface. Silicon (Si) in particular has been found to be essential for normal bone and cartilage growth and development. Zinc (Zn) plays very important roles in bone formation and immune system regulation, and is also the most abundant trace element in bone. The objective of this work was to study on electrochemical behaviors of PEO-treated Ti-6Al-4V Alloy in solution containing Zn and Si ions. The morphology, the chemical composition, and the microstructure analysis of the sample were examined using FE-SEM, EDS, and XRD. The potentiodynamic polarization and AC impedance tests for corrosion behaviors were carried out in 0.9% NaCl solution at similar body temperature using a potentiostat. The promising results successfully demonstrated the immense potential of Si/Zn-TiO2 coatings in dental and biomaterials applications.

  • PDF

차량 RKE 리더기용 PIFA형 스파이럴 안테나의 설계 (Design of PIFA type Spiral Antenna for Vehicle RKE Reader)

  • 오동준;윤호진;정봉식
    • 융합신호처리학회논문지
    • /
    • 제9권2호
    • /
    • pp.135-140
    • /
    • 2008
  • 본 논문에서는 자동차에 사용되는 RKE(Remote Keyless Entry) 시스템용인 중심주파수가 315MHz, 433MHz 및 447MHz이 스파이럴 안테나를 PCB(Printed Circuit Board)상에 설계하고자 한다. 안테나는 선로 급전하였으며, 급전부에는 중심주파수 조정과 임피던스 정합이 용이하도록 PIFA(Planar Inverted-F Antenna) 구조를 적용하였다. 안테나는 PCB상에 인쇄되며 PCB 면적의 5% 정도인 $30mm{\times}20mm$ 이내의 크기를 갖도록 설계하였고, PCB상의 회로소자 ECU (Electronic Control Unit) 케이스, ECU가 장착되는 차체의 영향을 고려하여 설계하였다. 또한 스파이럴 선로상에 칩 인덕터를 삽입하여 315MHz와 447MHz에서 이중공진을 일으키는 이중대역 스파이럴 안테나를 설계하였다. 최종 설계된 안테나는 측정을 통해 안테나 사양을 만족함을 확인하였고, 안테나를 ECU에 장착하여 실험한 결과, 전방향에서 20m이상의 수신거리를 가지면서 정상적으로 동작함을 확인하였다.

  • PDF

인체 신경신호 제어시스템 구현에 관한 연구 (A Study on the Control System Implementation of Human Body Nerves Signal)

  • 고덕영;김성곤;최종호
    • 전자공학회논문지 IE
    • /
    • 제43권1호
    • /
    • pp.16-24
    • /
    • 2006
  • 본 논문에서는 생체신호의 발생을 자유롭게 조절 할 수 있는 전정기관으로부터 생성된 전기신호를 추출하여 window discriminator로 필요한 신호를 선택한 후, BCI 시스템을 적용하여 정밀하고 정확한 제어가 가능하고 멀티채널을 이용하여 데이터를 처리할 수 있는 통합 시스템을 구현하였다. 전정신경세포의 흥분신호를 검출하는 전치증폭기는 측정된 이득이 47.6dB, 왜율은 100 Hz에서 측정 시 0.005%이었으며, 입력임피던스 특성은 12M$\Omega$이었다. Window discriminator는 2개의 CPU를 사용하여 역할을 분담함으로써 처리 속도를 증가시켰고, ADC 샘플링 주파수는 87kHz이었으며, 기존 시스템보다 분해능이 2배, 변별 오차는 10배가 향상되었음을 알 수 있었다. 제안된 방법이 뇌파분석법 보다 100ms동안 축적된 데이터양이 약 100배 정도 감소되었음을 입증하였다.

The Hazardous Components and Prevailing Rate of Sarcopenic Obesity in Younger Women : Based on 2008-2011 Korean National Health and Nutrition Examination Surveys

  • Jongseok Hwang;Chang-Ryeol Lee
    • 대한통합의학회지
    • /
    • 제12권2호
    • /
    • pp.1-10
    • /
    • 2024
  • Purpose : Sarcopenic obesity is associated with adverse health consequences in females. Nevertheless, there has been limited research on the hazardous components and prevailing rates of sarcopenic obesity among younger women. This study aimed to identify the hazardous components and prevailing rates of sarcopenic obesity in younger females. Methods : This study utilized data based on 2008~2011 from the Korea National Health and Nutrition Examination Surveys by the centers for disease control and prevention. The analysis was concentrated on a subset of 1,520 women aged between 30 and 39 years of age. The participants answered a questionnaire to gather demographic information. They then underwent a physical examination to measure the human detention variables, which was conducted utilizing bioelectrical impedance analysis. The blood pressure and blood laboratory tests were determined using established laboratory protocols for evaluating blood parameters. Results : This study included 1,520 patients aged 30~39 years old. The mean age of the participants was 34.97 (years)±2.74 and the overall prevailing rate was 1.84 %. The hazard components in human dimensions were the height, weight, body mass index (BMI), waist circumference (WC) and skeletal muscle mass index (SMI). The hazard components in biochemical and blood pressure were high fasting glucose, increased triglyceride, elevated total cholesterol, high systolic blood pressure, and increased diastolic blood pressure with p-values <.05. Conclusion : This study examined the hazardous components and prevailing rates of sarcopenic obesity in younger women living in the community. The results contribute to the current body of knowledge on sarcopenic obesity and shed light on possible hazardous components in a younger female population. Based on these findings, there should be increased health and medical attention towards the prevention, management, and health promotion related to reducing risk factors for sarcopenic obesity in younger women.

Rheogram으로 본 실혈시 신장혈액유통 변화 (Rheographic View of the Change in the Renal Blood Flow in Acute Hemorrhage)

  • 장세구;신동훈
    • The Korean Journal of Physiology
    • /
    • 제5권1호
    • /
    • pp.59-69
    • /
    • 1971
  • Studies were undertaken on the changes in the renal blood flow by relating them with the alterations in the amplitudes in the rheogram of rabbits. The changing pattern of the electrical conductivity was recorded by means of the needle electrodes inserted into the kidney and the surrounding aluminium foil which was grounded. The Impedance Rheograph manufactured by the Narco Company was used. The small artifact which persisted after ligation of the renal vessels was subtracted from the value obtained in each pulsatile wave in the rheogram. The animals were nembutalized intravenously, 30 mg/kg. A plastic canule was inserted into the carotid artery and the arterial blood pressure was monitored continuously with the pressure transducer connected to the physiograph. Stepwise bleedings were performed on the animal. The first bleeding was between 13 to 18 ml in the amount, and it was folowed by consecutive hemorrhages, 5 or 10 ml each time. The total amount of bleeding was summed as much as 1.5-2% of the body weight. Two minutes fter each bleeding th arterial blood pressure, ECG and the rheogram were taken. That was the necessary time to obtain the stabilized picture of each parameter. After closing the bleeding process, the shed blood was retransfused into the animal and the response in the renal blood flow was observed as well as the arterial blood pressure. Particularly the presence or absence of the autoregulatory mechanism in the situation of the hemorrhage was also studied. The results obtained were as follows: 1. In 7 cases out of 22, that was about one third of the total number of experiments, the autoregulatory mechanism of the renal blood flow persisted even in acute hemorrhage, and the decreases in the renal blood flow were less than 10% of the control values even when the arterial blood pressure dropped to 66-87% of the original value obtained before the bleeding. 2. Because of the stepwise bleeding the exact blood pressure at which the renal blood flow reduced as much as one third of the control value could not be obtained. However, the results revealed that the approximate pressure, expressed as percentage of the control value, was 50-60% in 3 cases, 61-70% in 4 cases and 71-80% in 8 cases. In one case the decrease in the renal blood flow exceeded one third of the control value before the pressure dropped to 80% of the control. 3. In 19 cases the decreases in the renal blood flow exceeded one half of the control values by hemorrhage. Then the arterial blood pressure revealed less than 40% of the control value in 6-cases. In 2 cases the pressure was 51-60% of the control pressure. In 5 cases the range of bleed pressure was 61-70%, and in e remaining 6 cases the pressure ranged from 71 to 80% of e control value. 4. Out of 15 cases of retransfusion after definite decreases in the renal blood flow loller·ing the hemorrhage, 9 cases restored their renal blood flow. On the contrary 6 cases showed low values even when the shed blood was retransfused. 5. Theories concerning the mechanism of the autoregulation of the renal blood flow were reviewed for the purpose of explanation of the results obtained. However, there are much to be done before greater satisfaction

  • PDF

국민학교 학동의 혈압에 관련된 요인분석 (Risk Factors in Relation to Blood Pressure in Schoolchildren)

  • 이동수;이경수;강복수
    • Journal of Yeungnam Medical Science
    • /
    • 제10권2호
    • /
    • pp.345-359
    • /
    • 1993
  • 대구시내 1개 국민학교 4학년 284명(남아 144명, 여아 140명)을 대상으로, 1992년 5월에 일반적인 특성을 조사하였고, 체격, 체지방 및 혈압을 측정하였으며, 혈액의 생화학적 검사를 실시하여 혈압과 관련된 요인을 분석하였다. 대상자의 평균 수축기 혈압은 103.5mmHg였으며, 남아가 104.1mmHg, 여아가 102.9mmHg로 남아가 약간 높게 나타났으며, 평균 확장기 혈압은 67.1mmHg이고, 남아가 66.6mmHg, 여아가 67.5mmHg로 여아가 약간 높았다. 수축기 및 확장기 혈압을 종속변수로 총콜레스테롤, 고밀도 지단백 콜레스테롤, 저밀도 지단백 콜레스테롤, 중성지방, 총단백질, 요산, 혈당, R$\ddot{o}$hrer지수, 체지방 비율, 체지방 무게 및 제지방체중을 독립변수로 하여 상관관계와 중회귀분석을 실시하였다. 수축기 및 확장기혈압과 독립변수들과의 상관관계를 성별에 따라 분석한 결과 남아의 수축기혈압은 신장, 체중, R$\ddot{o}$hrer지수, 제지방 체중, 체지방 무게 및 중성지방과 유의한 상관관계가 있었으며(p<0.01). 여아의 수축기혈압은 신장, 체중, 제지방체중 및 요산과 유의한 상관관계가 있었다(p<0.01). 남아의 확장기혈압은 체중, R$\ddot{o}$hrer지수 및 제지방체중과 유의한 상관관계가 있었으며(p<0.01). 여아의 확장기혈압은 체중, 제지방체중(p<0.01), 신장, 체지방무게 및 총단백질(p<0.05)과 유의한 상관관계가 있었다. 수축기 혈압을 종속변수로 한 중회귀분석에서 남아는 R$\ddot{o}$hrer지수와 sodium이 유의한 변수였고, 여아는 요산, R$\ddot{o}$hrer지수 및 체지방 비율이 유의한 변수였다. 확장기 혈압에서 남아는 R$\ddot{o}$hrer지수가 유의한 변수였고, 여아는 총단백질이 유의한 변수였다. 이상의 결과로 보아 소아의 혈압에 영향을 미치는 인자로는 R$\ddot{o}$hrer지수, sodium, 요산, 총단백질 및 체지방 비율 이었고, 그 중 R$\ddot{o}$hrer지수가 가장 중요한 요인으로 인정되었다. 따라서 고혈압 발생을 예방하기 위해서는 비만, 식이 및 이와 관련된 생활양식의 개선과 이에 대한 보건교육이 요망된다.

  • PDF

The Prevalence of Obsersity and Nutritional Status in Adult Women Who Exercise Regularly

  • Hwang, Hye-Sun;Park, In-Seon;Oh, Seung-Ho
    • Preventive Nutrition and Food Science
    • /
    • 제3권2호
    • /
    • pp.186-192
    • /
    • 1998
  • This study was conducted to investigate the relationship among prevalence of obesity, nutritional status and factors related to obesity of women who exercise regularly. The subjects of this study were 100 women who have been exercising regularly for more than 6 months. They were mostly housewives ages 24 to 63 years and had graduated middle or high school. Their average income was form 700 to 1,500 thousand won per month and most of them had 2 r 3 children. They sleep usually 6~8 hours a day. Most of physical indices of obesity were increased progressively with age. Among them , weight (61.5$\pm$1.4kg), subscapular (16.3$\pm$1.4mm) and abdomen(31.4$\pm$1.2mm) skinfold thickness were higher in 50 years than in others. BMI after exericse was decreased compared with BMI before exericise. WHR was 0.82 in 40 years and 0.85$\pm$0.01 in 50- to 60- year-old group. The percentage of body fat increased with advancing years and the highest values were shown in 50 - to 60-year old group (skyndex value : 38.6$\pm$0.6, BIA value : 28.7$\pm$0.8<0.05). The prevalence of obesity was measured by bioelectrical impedance fatness analyzer (BIA), obdy mass index (BMI) and skinfold thickness were 17.0%, 24.0% and 78.0% respectively. Most subjects were in good nutritional status, but in the subjects aged 24~49, energy (89.3%), iron (93.3%) and vit. A (97.4%) intake were slighltyl lower than the RDA. Energy intake was slightly insufficient tot he 50-63year old subjects (88.6%) compared with RDA. It seemed that they restricted calorie intake for the weight control. The energy percentage of carbohydrate, fat and protein was 65 : 20 : 15, the result of which came closed to the recommended calorei composition. There were positive correlations between obesity and other variable such as age. number of childeren and physical indics.

  • PDF

서울 거주 20대 여성의 아침식사 섭취 빈도에 따른 식습관 및 영양소 섭취상태 조사 (Dietary Habits and Nutritional Status of Young Women according to Breakfast Frequency in Seoul)

  • 김다미;김율리;김경희
    • 대한지역사회영양학회지
    • /
    • 제23권2호
    • /
    • pp.102-115
    • /
    • 2018
  • Objectives: Although breakfast is important to nutrition balance, prevention of overeating, and weight control, people in their 20s (males: 55.1%, females: 49.9%) were reported to have the highest rate of skipping breakfast in 2016 Korea Health Statistics. This study aims to examine dietary habits and nutrient intake depending on breakfast frequency among young women in Seoul. Methods: The subjects were 655 young women in Seoul from August to October 2016, and the survey was performed by using a questionnaire that included general characteristics, dietary habits, and eating behavior. Body composition was determined by bioelectric impedance analysis. Nutritional status was examined by the 24-hour recall method. Results: The participants were classified by breakfast intake frequency; '${\geq}5times/week$ (n=160)', '1-4 times/week (n=327)', and 'breakfast skipping (n=168)'. The 'breakfast skipping' group had lower frequency and regularity of meals. In addition, the 'breakfast skipping' group had a higher frequency of eating-out and late-night meals. There was no difference in total calories between the 'breakfast skipping' group and other groups, but the 'breakfast skipping' group had significantly low carbohydrate and fiber intakes. The participants showed lower intakes of calories, fiber, vitamin A, vitamin C, niacin, folic acid, calcium, potassium, and zinc in comparison with recommended intakes. Especially, the 'breakfast skipping' group had significantly lower fiber, vitamin A, vitamin C, calcium, potassium levels compared to the '${\geq}5times/week$' group. For Mean Adequacy Ratio (MAR), the 'breakfast skipping' group recorded a ratio of 0.60, which was lower than those of other groups. Index of Nutritional Quality (INQ) including fiber, vitamin C, calcium and phosphorus were significantly lower in the breakfast skipper group, compared to the breakfast eater group. Conclusions: The 'breakfast skipping' group showed low regularity of meals and a high frequency of eating-out and late-night meals. The breakfast regular eater group showed high intake of micronutrients and quality of meals was high in general. Skipping breakfast could lower nutrient intake and quality of meals, which requires attention.

비만아에서 혈청 호모시스테인, 인슐린, 비타민 B12, 엽산 농도에 대한 연구 (Homocysteine, insulin, vitamin B12 and folic acid levels in obese children)

  • 박지윤;홍영미
    • Clinical and Experimental Pediatrics
    • /
    • 제49권5호
    • /
    • pp.475-481
    • /
    • 2006
  • 목 적 : 소아 비만의 빈도가 점점 증가하면서 비만으로 인한 고혈압, 관상동맥 질환, 고지혈증, 인슐린 저항, 당뇨병 등의 합병증이 문제가 되고 있다. 관상동맥 질환에서 호모시스테인 치의 증가, 비타민 $B_{12}$ 섭취의 감소가 중요한 역할을 하고 있음이 보고되고 있으나, 비만에서는 아직 호모시스테인, 인슐린, 비타민 $B_{12}$에 대한 연구가 많지 않은 실정이다. 저자들은 호모시스테인, 인슐린, 비타민 $B_{12}$, 엽산이 비만아에서 어떤 연관성을 갖고 있는지를 알아보기 위하여 본 연구를 실시하였다. 방 법 : 8세부터 11세 사이에 비만도가 130 이상인 중등도 비만아 27명을 대상군으로 하였고, 같은 연령의 30명의 정상 소아를 대조군으로 하였다. 신장, 체중을 이용하여 비만도와 체질량 지수를 산출하였고, 안정된 상태에서 수축기, 이완기 혈압을 측정하였다. 10시간 이상 금식 후 총 콜레스테롤, 중성지방, 호모시시테인, 인슐린, 비타민 $B_{12}$, 엽산을 측정하였다. 생체전기저항법을 이용하여 세포내액, 세포외액, 단백질, 무기질, 근육량, 체지방량, 체지방률, 복부지방률 등을 분석하였다. 결 과 : 호모시스테인은 비만군에서 $8.1{\pm}2.1{\mu}mol/mL$$4.9{\pm}1.0{\mu}mol/mL$인 정상군보다 유의하게 높았고, 인슐린도 비만군에서 $26.8{\pm}11.2{\mu}IU/mL$$12.5{\pm}5.24{\mu}IU/mL$인 정상군보다 유의하게 높았다. 비타민 $B_{12}$는 비만군에서 $798.6{\pm}174.3pg/mL$$967.8{\pm}405.0pg/mL$인 정상군보다 유의하게 낮았다. 그러나 엽산은 두 군 사이에 유의한 차이가 없었다. 비만군에서 인슐린은 수축기 혈압(r=0.535), 중성 지방(r=0.517), 총 콜레스테롤(r=0.408), 복부지방률(r=0.306)과 양의 상관관계가 있었다. 결 론 : 비만아에서 호모시스테인, 인슐린과 비타민 $B_{12}$가 의미있는 혈중 농도 차이를 보였으나 심혈관 질환 등의 성인병을 예방하는 예측 인자로 사용할 수 있는지 알기 위해 더 많은 연구가 필요하겠다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF