• Title/Summary/Keyword: blood vessel pressure

Search Result 134, Processing Time 0.027 seconds

A Case Report of Prolonged Hemorrhage Following Traditional Phlebotomy (Fasd)

  • Sajjad Sadeghi
    • Journal of Pharmacopuncture
    • /
    • v.27 no.1
    • /
    • pp.47-52
    • /
    • 2024
  • Phlebotomy, a therapeutic method of bloodletting typically performed using a needle, has a traditional technique known as "Fasd." In this method, blood is extracted by creating a longitudinal incision on a vein (3-5 mm) with a surgical scalpel blade, usually blade No. 11. Due to the incision in the vessel wall, establishing hemostasis is more challenging compared to conventional methods. Hemostasis is usually achieved within minutes after Fasd. We present a case highlighting an uncommon yet significant complication of traditional phlebotomy. A 55-year-old man with no prior medical conditions underwent traditional phlebotomy at an academic traditional medicine clinic. Senior MD-PhD students in Iranian Traditional Medicine, under professor supervision, performed Fasd. A sterile scalpel blade No. 11 was used to create a longitudinal incision of approximately 4 mm on the patient's median basilic vein in the right hand. After removing 400 cc of blood, a pressure dressing was applied to the incision site. Despite attempts such as hand elevation, ice pack application, prolonged direct pressure, and tight elastic bandaging, bleeding from the incision persisted. After an hour of supportive therapy, hemostasis was eventually achieved within a few minutes using burnt cotton dressing (a traditional method for blood hemostasis). Following intravenous hydration, the patient was discharged in stable condition and reported no issues during the one-month follow-up. The traditional phlebotomy (Fasd) carries the risk of serious complications, including uncontrolled and prolonged bleeding. Further research on the efficacy and safety of burnt cotton dressing for controlling hemostasis is recommended.

NUMERICAL ANALYSIS FOR THE EFFECT OF BLOOD FLOW RATE AND BIFURCATION ANGLE ON THE LOCATION OF ANTERIOR CIRCULATION ANEURYSM AND THE CHANGE OF BLOOD FLOW CHARACTERISTICS AFTER ANEURYSM FORMATION (전방순환동맥류 발생 위치에 대한 혈류량 및 분지각의 영향 및 동맥류 발생 전후의 유동 변화에 관한 수치해석 연구)

  • Kim, S.Y.;Ro, K.C.;Ryou, H.S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.161-168
    • /
    • 2011
  • Cerebral aneurysm mostly occurs at a bifurcation of the circle of Willis. When the cerebral aneurysm is ruptured a disease like subarachnoid hemorrhage and stroke is caused and this can be even deadly for patients. Generally it is known that causes of the intracranial aneurysm are a congenital deformity of the artery and pressure or shear stress from the blood flow. A blood flow pattern and the geometry of the blood vessel are important factors for the aneurysm formation. Research for several hemodynamic indices has been performed and these indices can be used for the prediction of aneurysm initiation and rupture. Therefore, the numerical analysis was performed for hemodynamic characteristics of the blood flow through the cerebral artery applying the various bifurcation angle and flow rate ratio. We analyze the flow characteristics using indices from the results of the numerical simulation. In addition, to investigate the flow pattern in the aneurysm according to the bifurcation angle and the flow rate ratio, we performed the numerical simulation on the supposition that the aneurysm occurs.

  • PDF

In-vivo Measurements of Blood Flow Characteristics in the Arterial Bifurcation Cascade Networks of Chicken Embryo (유정란 태아외부혈관의 단계적으로 분기되는 동맥 분지관 내부 혈액 유동특성의 in-vivo 계측)

  • Lee, Jung-Yeop;Lee, Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2006.12a
    • /
    • pp.121-124
    • /
    • 2006
  • The arteries are very important in cardiovascular system and easily adapt to varying flow and pressure conditions by enlarging or shrinking to meet the given hemodynamic demands. The blood flow in arteries is dominated by unsteady flow phenomena due to heart beating. In certain circumstances, however, unusual hemodynamic conditions cause an abnormal biological response and often induce circulatory diseases such as atherosclerosis, thrombosis and inflammation. Therefore quantitative analysis of the unsteady pulsatile flow characteristics in the arterial blood vessels plays important roles in diagnosing these circulatory diseases. In order to verify the hemodynamic characteristics, in-vivo measurements of blood flow inside the extraembryonic arterial bifurcation cascade of chicken embryo were carried out using a micro-PIV technique. To analyze the unsteady pulsatile flow temporally, the (low images of RBCs were obtained using a high-speed CMOS camera at 250fps with a spatial resolution of $30{\mu}m\times30{\mu}m$ in the whole blood vessels. In this study, the unusual flow conditions such as flow separation or secondary flow were not observed in the arterial bifurcations. However, the vorticity has large values in the inner side of curvature of vessels. In addition, the mean velocity in the arterial blood vessel was decreased and pulsating frequency obtained by FFT analysis of velocity data extracted in front of the each bifurcation was also decreased as the bifurcation cascaded.

  • PDF

A Design and Implementation Digital Vessel Bio Emotion Recognition LED Control System (디지털 선박 생체 감성 인식 LED 조명 제어 시스템 설계 및 구현)

  • Song, Byoung-Ho;Oh, Il-Whan;Lee, Seong-Ro
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.2
    • /
    • pp.102-108
    • /
    • 2011
  • The existing vessels lighting control system has several problems, which are complexity of construction and high cost of establishment and maintenance. In this paper, We designed low cost and high performance lighting control system at digital vessel environment. We proposed a system which recognize the user's emotions after obtaining the biological informations about user's bio information(pulse sensor, blood pressure sensor, blood sugar sensor etc) through wireless sensors controls the LED Lights. This system classified emotions using backpropagation algorithm. We chose 3,000 data sets to train the backpropagation algorithm. As a result, obtained about 88.7% accuracy. And the classified emotions find the most appropriate point in the method of controlling the waves or frequencies to the red, green, blue LED Lamp comparing with the 20-color-emotion models in the HP's 'The meaning of color' and control the brightness or contrast of the LED Lamp. In this method, the system saved about 20% of the electricity consumed.

Blood Vessel Aging Diagnosis System using Blood Pressure and Photoplethysmography (사지혈압과 용적맥파를 이용한 혈관 노화도 진단 시스템)

  • Kim, Pan-Ki;Cho, Sang-Heum;Kim, Byung-Sun;Kang, Mahn-Hee;Ahn, Chang-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1979-1980
    • /
    • 2008
  • 본 논문은 심혈관질환을 예방하기 위한 심박변이도 검사(HRV), 압맥파 검사(PTG), 용적맥파 검사(SDPTG), 사지혈압 검사(BPD), 맥파전달속도 검사(PWV)를 통해 심혈관의 상태를 분석하고 질병을 예방하는데 도움이 될 수 있도록 측정하고 진단 할 수 있는 심혈관 질환에 대한 통합 진단 시스템을 개발하였다. 본 논문에서 개발된 진단 시스템을 통해서 나오는 결과에 대한 소개하였다.

  • PDF

The Effect of Gamigehyuldeung-tang on Hypertension (가미계혈등탕(加味鷄血藤湯)이 고혈압(高血壓)에 미치는 영향(影響))

  • Oh, Young-Seon;Kim, Yoon-Sik;Seol, In-Chan;Yu, Byeong-Chan
    • The Journal of Internal Korean Medicine
    • /
    • v.25 no.4
    • /
    • pp.52-64
    • /
    • 2004
  • Objectives : This study was done to investigate the effect of Gamigehyuldeung-tang on hypertension. Methods : After administering Gamigehyuldeung-tang extract to SHR(Spontaneous Hypertensive Rats) for 5 weeks, changes in blood pressure, pulse rate, aldosterone and catecholamine levels in plasma were examined, and immunohistochemical changes and scanning electron microscopic changes were observed. Results : The following results were obtained; blood presure decreased significantly as well as levels of aldosterone, dopamine and epinephrine in SHR. But levels of norepinephrine were unaffected. No capillary vessel dilation was observed. A decrease in cell damage was seen in microscope investigation. Conclusions : These results support a role for Gamigehyuldeung-tang might be usefully applied in treatment of hypertension.

  • PDF

Effect of Ganyangsanghang-bang on Hypertension (간양상항방(肝陽上亢方)이 고혈압(高血壓)에 미치는 영향)

  • Han, Deok-Hee;Oh, Young-Seon;Seol, In-Chan;Kim, Yoon-Sik
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.20 no.3
    • /
    • pp.663-669
    • /
    • 2006
  • This study was done to investigate the effect of Ganyangsanghang-bang(GYSHB) on hypertension. After administering GYSHB extract to SHR for 5 weeks, changes in blood pressure, pulse rate, aldosterone and catecholamine levels in plasma were examined, and immunohistochemical changes were observed, and liver function test was done. The following results were obtained; blood presure decreased significantly as well as levels of aldosterone and norepinephrine in SHR. But levels of dopamine were unaffected. No capillary vessel dilation in adrenal cortex was observed. Safety against hepatic toxicity was showed. These results support a role for GYSHB might be usefully applied in treatment of hypertension.

Effect of Gamisamool-tang(GMSMT) on Hypertension (가미사물탕(加味四物湯)이 고혈압에 미치는 영향)

  • Cho Bong-Hyun;Kim Yoon-Sik;Seol In-Chan
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.20 no.1
    • /
    • pp.131-137
    • /
    • 2006
  • This study was done to investigate the effect of Gamisamool-tang(GMSMT) on hypertension. After administering GMSMT extract to SHR for 5 weeks, changes in blood pressure, pulse rate, aldosterone and catecholamine levels in plasma were examined, and immunohistochemical changes were observed, and liver function test was done. The following results were obtained; blood presure decreased significantly as well as levels of aldosterone, norepinephrine and epinephrine in SHR, But levels of dopamine were unaffected. No capillary vessel dilation in adrenal cortex was observed. Safety against hepatic toxicity was showed. These results support a role for GMSMT might be usefully applied in treatment of hypertension.

Effects of stenotic severity on the flow structure in a circular channel under a pulsatile flow

  • Kim, Kyung-Won;Cheema, Taqi-Ahmad;Park, Cheol-Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.2
    • /
    • pp.140-146
    • /
    • 2014
  • Stenosis is the drastic reduction in the cross-sectional area of blood vessel caused by accumulations of cholesterol. It affects the blood flow property and structure from the fluid dynamic point of view. To understand the flow phenomenon more clearly, a particle image velocimetry method is used and the fluid dynamic characteristics in a circular channel containing stenosis structure is investigated experimentally in this study. Different stenotic-structured models made of acrylic material are subjected to a pulsatile flow generated by an in-house designed pulsatile pump. The inner diameter of the tube inlet is 20 mm and the length of reduced area for stenosis ranges between 35mm and 40mm. It is circulated continuously through a circular channel by the pump system. Pressure is measured at four different sections during systolic and diastolic phase changes. The phase-averaged velocity field distribution shows a recirculation regime after the stenotic structure. The effects of the stenotic obstructions are found to be more severe when the aspect ratio is varied.

On Study of Pulse Wave Signal According to Postural Change Using Finger Plethysmography (손가락 끝 용적맥파를 이용한 자세변화에 따른 맥파 신호에 관한 연구)

  • Choi, B.C.;Kim, C.H.;Jung, D.K.;Suh, D.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.125-126
    • /
    • 1998
  • Pulse conduction velocity is determined by areterial compliance, which is changed by lateral pressure of arterial wall. Hydrostatic pressure of the limb vessel is changed by body position, especially in elevated arm. The arterial pulse in the finger causes the blood volume to change, changing the optical density of the blood. Photoplethysmograph of index finger was obtained by LED and phototransistor. Pulse transmission time(PTT) was measured by the interval between the peak of ECG R wave and the peak of the finger plethysmogram. PTT was increased by upward position of arm, and decreased by downward position of the arm compared to horizontal position. This result suggests that relationship between finger plethysmography and postural change could be applied to evaluate clinical cardiovascular status.

  • PDF