• 제목/요약/키워드: blood vessel pressure

Search Result 132, Processing Time 0.025 seconds

Analysis of Correlativity with Blood Pressure and Measurement of Brain Blood Pressure(BBP) (뇌혈압 측정과 상완 혈압의 상관성 분석)

  • Ko, Su-Bok;Lee, Yong-Heum;Kim, Sung-Gon;Jeong, Dong-Myong
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.180-183
    • /
    • 2001
  • In modem city life, the citizen get insufficient exercise and has high levels of stress. Increased Stress causes such minor things as tiredness, disease and mental fatigue, and increase brain blood pressure too. In this paper trying to design the multi-functional blood pressure monitor with airo-dynamic brain hemokinesis improvement function. So this system have developed for the improvement of flows in the capillary blood vessel of head and limbs. Also This system is able to measure brain blood pressure(BBP) which need diagnosis circulation state of brain blood. So, we extracted correlativity of blood pressure(BP) and BBP through clinical experiment. We confirmed that compare factor of BP with BBP is more useful factors for diagnosis state of brain hemokinesis.

  • PDF

Flexible wireless pressure sensor module

  • Shin Kyu-Ho;Moon Chang-Ryoul;Lee Tae-Hee;Lim Chang-Hyun;Kim Young-Jun
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2004.11a
    • /
    • pp.3-4
    • /
    • 2004
  • A flexible Packaging scheme, which embedded chip packaging, has been developed using a thinned silicon chip. Mechanical characteristics of thinned silicon chips are examined by bending test and finite element analysis. Thinned silicon chips ($t<50{\mu}m$) are fabricated by chemical etching process to avoid possible surface damages on them. These technologies can be use for a real-time monitoring of blood pressure. Our research targets are implantable blood pressure sensor and its telemetric measurement. By winding round the coronary arteries, we can measure the blood pressure by capacitance variation of blood vessel.

  • PDF

A Study on the Shear Stress Distribution of the Steady and Physiological Blood Flows (정상 및 박동성 혈류의 전단응력분포에 관한 연구)

  • Suh, S.H.;Yoo, S.S.;Roh, H.W.;Shim, J.W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.113-116
    • /
    • 1995
  • Steady and physiological flows of a Newtonian fluid and blood in the bifurcated arterial vessel are numerically simulated. Distributions of velocity, pressure and wall shear stress in the bifurcated arterial vessel are calculated to investigate the differences between steady and physiological flows. For the given Reynolds number physiological flow characteristics of a Newtonian fluid and blood in the bifurcated arterial vessel are quite different from those of steady flows. No flow separation or flow reversal in the bifurcated region in the downstream after stenosis appears during the acceleration phase. Also, no recirculation region is seen for steady flows. However, during the deceleration phase the flow began to exhibit flow reversal, which is eventually extended to the entire wall region.

  • PDF

A Numerical Analysis on the Motion of a Curved Bileaflet in Mechanical Heart Valve(MHV) and the Characteristics of Blood Flow in an Elastic Blood Vessel (탄성혈관 내 곡면형 이엽 기계식 인공심장판막의 거동 및 혈액 유동 특성에 관한 수치해석적 연구)

  • Bang J. S.;Choi C. R.;Kim C. N.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.203-206
    • /
    • 2004
  • In this study, a numerical analysis has been performed for a three-dimensional pulsatile blood flow associated with the elastic blood vessel and curved bileaflet for multiple cycles in terms of fluid-structure interaction. Here, blood has been assumed as a Newtonian, incompressible fluid. Pressure profiles have been used as boundary conditions at the ventricle and the aorta. From this analysis, the motion of the leaflet has been observed with fluttering phenomenon and rebound, and the flow fields of blood have been obtained with recirculation and regurgitation. The results can contribute to the development of design methodology for the curved bileaflet mechanical heart valve.

  • PDF

Characteristic Study of the Pulse Position on CHON, KWAN and CHUCK Using the Ultrasonic Waves (초음파 분석을 이용한 촌관척 위치별 혈관의 특성연구)

  • Lee, Yu-Jung;Lee, Jeon;Lee, Hae-Jung;Ryu, Hyun-Hee;Choi, Eun-Ji;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.3
    • /
    • pp.111-117
    • /
    • 2007
  • The study aims to measure and analyze the thickness and depth of blood vessel on the pulse diagnosis locations and the blood velocity through the use of ultrasonic waves (LOGIQ5PRO, GE Medical, U.S.) in order to understand the structural difference of pulse diagnosis locations. The subjects included 44 healthy men and women(22.28${\pm}$2.62 age) considered normal in terms of Body Mass Index(BMI). The thickness and depth of the blood vessel and the blood velocity were measured three times on CHON, KWAN and CHUCK to obtain the average value. Results showed there is a statistically significant difference among the variables measured on CHON, KWAN and CHUCK. A difference according to gender was also observed. This explains why an oriental medical doctor can tell the difference in pulses depending on the location of CHON, KWAN and CHUCK. In addition, the difference in pressure between CHON and KWAN was higher than that in pressure between KWAN and CHUCK. The findings explain why oriental medical doctors take pulses by dividing CHON, KWAN and CHUCK in the short length of the three fingers. It can be used to develop a pulse diagnosis device enabling accurate measurement according to the characteristics of blood vessel structure based on where the pulse is taken. Furthermore, the results can be used as basic data for the development of a pulse diagnosis simulator.

  • PDF

Effect of the Pulsatile Flow on the Morphological Changes of the Endothelial Cells in Blood Vessel (맥동유동이 혈관내 내피세포의 형태변화에 미치는 영향)

  • Suh, Sang-Ho;Yoo, Sang-Sin;Cho, Min-Tae;Park, Chan-Young;Chang, Jun-Keun
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.531-534
    • /
    • 2000
  • The objective of this investigation is to find effects of the pulsatile flow on the morphological changes of the endothelial cell(E.C.) in blood vessel. The shear flow experiment system is used to get the morphological changes of the E.C. The shapes of E.C. are simulated by the cosine curves and computer simulation is used to calculate the pressure and shear stress fields on the E.C. The inlet boundary condition is given from the measured velocity data of femoral artery. The endothelial cells reduce their heights in the flow field so as to reduce the pressure and wall shear stress on the surface. As the exposed time increases, the shear stress and pressure on the E.C. are reduced under the pulsatile flow. The shear stresses on the cell surface show the minimum values during the deceleration phase.

  • PDF

Time-synchronized measurement and cyclic analysis of ultrasound imaging from blood with blood pressure in the mock pulsatile blood circulation system (박동 혈액 순환 모의 시스템에서 시간 동기화된 혈압 및 혈액의 초음파 영상 측정 및 주기적 분석)

  • Min, Soohong;Jin, Changzhu;Paeng, Dong-Guk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.5
    • /
    • pp.361-369
    • /
    • 2017
  • Hemodynamic information in the carotid artery bifurcation is very important for understanding the development and progression mechanisms of cerebrovascular disease and for its early diagnosis and prediction of the progress. In this paper, we constructed a mock pulsatile blood circulation system using an anthropomorphic elastic vessel of the carotid artery bifurcation and ex vivo pig blood to acquire ultrasound images from blood and vessels synchronized with internal pressure while controlling the blood flow. Echogenicity, blood flow velocity, and blood vessel wall motion from the ultrasound images, and internal blood pressure were extracted over a cycle averaged from five cycles when the pulsatile pump rates are 20 r/min, 40 r/min, and 60 r/min. As a result, respectively, the peak systolic blood flow velocities were 20 cm/s, 25 cm/s, and 40 cm/s, the blood pressure differences were 30 mmHg, 70 mmHg, and 85 mmHg, the arterial walls were expanded to 0.05 mm, 0.15 mm, and 0.25 mm. Time-delayed cyclic variation of echogenicity compared to blood flow and pressure was observed, but the variation was minimal at 20 r/min. Time-synchronized cyclic variations of these parameters are important information for accurate input parameters and validation of the computational hemodynamic experiments which will provide useful information for the development and progress mechanisms of carotid artery stenosis.

Analysis of Blood pressure influence factor Correction for Photoplethysmography Fusion Algorithm Calibration (광전용적맥파 융합 알고리즘 보정을 위한 혈압 영향인자 상관관계 분석)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.2
    • /
    • pp.67-73
    • /
    • 2019
  • The blood pressure measurement is calculated as a value corresponding to the pressure of the blood vessel using the pressure from the outside for a long time. Due to the recent miniaturization of measurement equipment and the ICT combination of personal healthcare systems, a system that enables continuous and real-time measurement of blood pressure with a sensor is required. In this study, blood pressure was measured using pulse transit time using Photoplethysmography. In this study, blood pressure was estimated by using systolic blood pressure. And it is possible to make measurement only with PPG itself, which can contribute to making a micro blood pressure measuring device. As a result, systolic blood pressure and PPG's S1-P and P-S2 were used to analyze the possibility of blood pressure estimation.

Compensation of Error in Noninvasive Blood Pressure Measurement System Using Optical Sensor (광학 센서를 이용한 비관혈적 혈압 측정의 오차 보정)

  • Ko, J.I.;Jeong, I.C.;Lee, D.H.;Park, S.W.;Hwang, S.O.;Park, S.M.;Kim, G.Y.;Joo, H.S.;Yoon, H.R.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.178-186
    • /
    • 2007
  • This study is attempted to correct an error of electronic blood pressure meter with an optical sensor. In general, for a hospitalized patient, ECG, blood pressure, oxygen saturation, and respiration are basically measured to monitor the patient's condition. Opening of a blood vessel after it is occluded by pressurizing the cuff influences the blood flow of peripheral blood vessels as well as oscillation changes in the cuff. Blood vessels are occluded and peripheral blood flow disappears at cuff pressure above the examinee's blood pressure, while blood vessels are opened and peripheral blood flow appears again at cuff pressure under the examinee's blood pressure. Then Disappear-Appear Point Length(DAPL) of peripheral blood flow can be judged with the signal of peripheral blood flow, thus is available as a factor of error correction for electronic blood pressure meter. Also, systolic or diastolic blood pressure can be corrected with Appear-Point-Pressure(APP) of cuff pressure at a point where blood flow occurs and Appear-Maximum Pressure(AMP) of cuff pressure at the maximum amplitude point of peripheral blood flow after peripheral blood flow appears again. For verification, 27 examinees were selected, and their blood value was obtained through experimental procedure of 4 stages including induction of blood pressure change. The examinees were divided into two groups of experimental group and control group, regression analysis was conducted for experimental group, and correction of a blood pressure error was verified with optical signal by applying the regression equation calculated in experimental group to control group. As an experimental result, mean of the whole measurement errors was 5mmHg or more, which did not meet the standard fur blood pressure meter. As a result of correcting blood pressure measurements with data of DAPL, APP, and AMP as drawn out of PPG signal, systolic blood pressure, mean blood pressure, and diastolic blood pressure were $-0.6{\pm}4.4mmHg,\;-1.0{\pm}3.9mmHg$ and $-1.3{\pm}5.4mmHg$, respectively, indicating that mean of the whole measurement errors was greatly improved, and standard deviation was decreased.

Spectral Element Modeling for the Blood Flow through Artery (동맥 유동해석을 위한 스펙트럴 요소의 개발)

  • Jang, In-Joon;Seo, Bo-Sung;Lee, U-Sik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.383-386
    • /
    • 2007
  • As the blood flow characteristics have been recognized to be closely related to various cardiovascular diseases, it is very important to predict them accurate enough in an efficient way. Thus, this paper proposes a one-dimensional spectral finite element model for the human blood vessels. The spectral finite element model is formulated in the frequency-domain by using the exact frequency dependent shape functions and applied to an ascending aorta.

  • PDF