• 제목/요약/키워드: blood vessel pressure

검색결과 132건 처리시간 0.032초

탄성혈관 내 기계식 인공심장판막(MHV)의 거동 및 혈액 유동 특성에 관한 수치해석적 연구 (A Numerical Analysis on the Motion of Mechanical Heart Valve(MHV) and Characteristics of Blood Flow in an Elastic Blood Vessel)

  • 방진석;최청렬;김창병
    • 한국정밀공학회지
    • /
    • 제22권3호
    • /
    • pp.154-161
    • /
    • 2005
  • In this study, the leaflet motion of a mechanical heart valve and the characteristics of two-dimensional transient blood flow in an elastic blood vessel have been numerically investigated by using fluid-structure interaction method. Here, blood has been assumed as a Newtonian, incompressible fluid. Pressure profiles have been used as boundary conditions at the ventricle and the aorta. As a result, closing motion of the leaflet is faster than opening one. While opening angles of leaflet grow up, vortex is detected at the sinus and backward of the leaflets. When the leaflet is fully closed, vortex is detected at the ventricle and at that moment maximum displacement of the elastic blood vessel is observed in the vicinity of the sinus region. Maximum displacement is caused in association with the blood flow that is oriented toward the elastic blood vessel.

내부직경 변화를 고려한 혈관의 유체-구조 상호작용 해석 (Fluid-Structure Interaction Analysis of Blood Vessel Considering Internal Diameter Variation)

  • 레사 옥타비안티;김동현;김수현;보이케 나바반;변준호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.959-963
    • /
    • 2006
  • A three-dimensional elastic blood vessel model with internal diameter variation is considered to investigate internal flow characteristics and effects of structural deformation. Also, computational analyses for both the rigid model and the fully-coupled FSI model have been conducted in order to compare the shear stress, pressure distribution, and flow velocity in detail. A 70% narrowing area of asymmetric blood vessel model was especially investigated to show the versatility of fluid-structure interaction phenomenon. The results reveal that effect of fluid-structure interaction is very important to accurately investigate the flow characteristics of the blood vessel.

  • PDF

폴리머/ 금속 다층 공정 기술을 이용한 실시간 혈압 모니터링을 위한 유연한 생체 삽입형 센서 (Implantable Flexible Sensor for Telemetrical Real-Time Blood Pressure Monitoring using Polymer/Metal Multilayer Processing Technique)

  • 임창현;김용준;윤영로;윤형로;신태민
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권6호
    • /
    • pp.599-604
    • /
    • 2004
  • 본 논문에서는 폴리머/ 금속 다층 공정 기술 (polymer/metal multi layer processing techniques)을 이용한 실시간 혈압 감지를 위한 유연한 생체 삽입형 센서를 새로이 제안한다. 제안되는 방식의 센서는 기계적으로 유연하기 때문에 혈관의 외벽에 대한 침습성을 감소시켜 부착할 수 있다. 즉, 혈압 측정을 위해 센서를 혈관 내에 설치하던 기존의 방법들에 비해서 혈관 자체에 상처를 주지 않고 혈압의 상대적인 변화를 지속적으로 감지할 수 있다. 성인에게 발생하는 급사의 주된 원인은 협심증, 심근 경색과 같은 혈관 관련 질환이다. 플라크 (plaque)의 생성 등과 관계된 순환계 관련 질환들은 지속적인 혈압 감지를 통해서 예방할 수 있으며 발병 초기에 치료할 수 있다. 본 연구에서 제안하는 혈압감지 방법의 과정은 다음과 같다. 우선, 집적된 센서를 혈관 외벽에 부착한다. 둘째, 실장된 센서가 혈관의 기계적인 수축과 확장을 인식한다. 마지막으로, 센서에 의해 인식된 혈압의 변화를 원격 감지 방법을 통해서 외부 안테나에서 감지하게 된다. 센서 시스템에는 어떠한 능동 소자도 존재하지 않기 때문에 에너지와 혈압 변화 정보는 LC 공진기와 외부 안테나 사이에 발생하는 상호 인덕턴스 원리에 의해서 전달되게 된다. 이러한 측정 원리의 가능성을 확인하기 위해서 실리콘 고무관과 혈액을 이용하여 시험관 실험 (In vitro test)을 진행하였다. 우선, 혈액으로 채운 실리콘 고무관에 센서를 감은 후 피스톤으로 압력을 가하였다. 그리고 이를 통해 가해진 압력 변화에 따른 공진 주파수의 변화를 측정하였다. 가해진 압력이 0부터 213.3 KPa까지 변화하는 동안 2.4 MHz의 공진 주파수가 변했다. 그러므로 생체 삽입형 혈압 센서의 감도는 11.25 KHz/KPa이다.

A Numerical Analysis on the Curved Bileaflet Mechanical Heart Valve (MHV): Leaflet Motion and Blood Flow in an Elastic Blood Vessel

  • Bang, Jin-Seok;Choi, Choeng-Ryul;Kim, Chang-Nyung
    • Journal of Mechanical Science and Technology
    • /
    • 제19권9호
    • /
    • pp.1761-1772
    • /
    • 2005
  • In blood flow passing through the mechanical heart valve (MHV) and elastic blood vessel, hemolysis and platelet activation causing thrombus formation can be seen owing to the shear stress in the blood. Also, fracture and deformation of leaflets can be observed depending on the shape and material properties of the leaflets which is opened and closed in a cycle. Hence, comprehensive study is needed on the hemodynamics which is associated with the motion of leaflet and elastic blood vessel in terms of fluid-structure interaction. In this paper, a numerical analysis has been performed for a three-dimensional pulsatile blood flow associated with the elastic blood vessel and curved bileaflet for multiple cycles in light of fluid-structure interaction. From this analysis fluttering phenomenon and rebound of the leaflet have been observed and recirculation and regurgitation have been found in the flow fields of the blood. Also, the pressure distribution and the radial displacement of the elastic blood vessel have been obtained. The motion of the leaflet and flow fields of the blood have shown similar tendency compared with the previous experiments carried out in other studies. The present study can contribute to the design methodology for the curved bileaflet mechanical heart valve. Furthermore, the proposed fluid-structure interaction method will be effectively used in various fields where the interaction between fluid flow and structure are involved.

Numerical study on Comparison of Self-Pressurization Behavior of Liquid Nitrogen Cryostat for Umbilical Cord Blood Storage System Design

  • Mahfud, M.I.;Phil, K.E.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.409-414
    • /
    • 2009
  • Since cryogens are stored at very low temperatures, the cryogenic storage systems are quite sensitive to heat leaks. Even though the vessel operated under sealed condition with vacuum insulation and reflective coatings are used, the heat leakage into the vessel is still unavoidable. Therefore, this paper concerns with numerical study of self-pressurization used to analysis the optimum design with the variation volume fraction, effect of heat flux and storage pressure of liquid nitrogen. The result shows that as the volume fraction increases, the pressure rise reduces and the relatively at atmosphere pressure is better than the higher one. In addition, higher heat flux leads the pressure rise increases faster than low one. The additional of heat pipe system to reduce the pressure rise rate also has been done. By this comparison, the optimum design for storage umbilical cord blood can be selected.

  • PDF

전자혈압강하기의 전기적 특성 분석 (An Electrical Characteristics Analysis of Electronic Blood Pressure Depressor)

  • 이권순;서진호;이진우
    • 동력기계공학회지
    • /
    • 제10권1호
    • /
    • pp.83-89
    • /
    • 2006
  • Recently, the seriousness of high blood pressure was appeared as the most frequent disease of a the whole sickness in the world. However, the treatment of this disease is uncertain and produces an adverse reaction of a medicine therapy. Also, the patients are burdened with a fee for medical treatment. Therefore, in this paper, we studied effectively and financially to execute the treatment of high blood pressure using the Chinese medicine theorem that is recently arousing the great interest of the people. The main theories in this paper are blood vessel theory and acupuncture, respectively. Especially, the composed circuit systems are classified the blood pressure depressor part and the meridian points discrimination part, respectively. The blood pressure depressor part is composed generally of low-frequency generation circuit, charging-discharging circuit, and micro-computer circuit. Finally, this research have the advantage of discrimination parts such as regular voltage generating circuit, stimulus circuit, amplifying circuit, and alarm circuit.

  • PDF

협착 동맥혈관의 혈류유동 모델링 (Modeling of Hemodynamics in Stenosed Artery)

  • 김성종;박영란;김상진;강형섭;김진상;오성훈;강성준;김기범
    • 한국산학기술학회논문지
    • /
    • 제13권5호
    • /
    • pp.2285-2290
    • /
    • 2012
  • 동맥경화는 혈관 안에서 콜레스테롤의 침착 때문에 혈관이 좁아지거나, 딱딱해 지거나, 두꺼워 지게 되는데, 이런 현상이 심해지게 되면 동맥은 단단해져서 혈액이 원활히 통과하지 못하게 되고 심하면 사망 까지 이르게 되는 것이다. 본 연구에서는 복대동맥에서의 동맥경화가 진행되는 것을 탄성 혈관 일 때와 강성 혈관 일 때 각각 협착률이 혈관 직경의 20과 45%로 설정하고 속도와 압력 변화를 살펴보기 위하여 유한 요소 해석을 이용하여 모델링을 하였다. 혈관이 탄성 혈관일 때 속도와 압력 값은 협착률이 혈관 직경의 20%일 때 보다 45%일 때 더 높게 나타났으며, 강성 혈관에서 속도와 압력 값은 협착률이 혈관 직경의 20%일 때보다 45%에서 더 높았다. 협착률이 혈관 직경의 20과 45%인 탄성 혈관에서 재순환영역이 나타났다. 본 연구결과 혈관 협착에 따른 혈류역학적 특징을 이해하는데 도움이 될 것으로 판단된다.

고전적 및 삼각조각 기법을 이용한 단-측면 미세동맥 접합술의 실험적 연구 (The Experimental Study of the End-to-side Microarterial Anastomosis with the Longitudinal Slit and the Triangular Flap)

  • 이준모;이강욱;이동근
    • Archives of Reconstructive Microsurgery
    • /
    • 제1권1호
    • /
    • pp.51-55
    • /
    • 1992
  • Problems of composite tissue transfer commonly arise when a single indispensable recipient vessel receives the graft vssel, and the graft vessel must be sutured in end-to-side fashion so as not todisturb the vascularity of the recipient vessel. The triangular flap in the recipient vessel wall gives an intact endothelial surface when the flow of blood stream is presented and may reduce the chance of anastomosis. We selected mature Wistar rats weighing over 450 grams to compare the conventional longitudinal slit from the triangular flap in the recipient carotid artery over bloood pressure and blood flow when the donor carotid artery was anastomosed in end-to-side fashion. In 30 minutes after anastomosis, maximum blood pressure measured in the donor carotid arterial side when the recipient arterial wall was fasioned with the longitudinal slit was recorded 114 mmHg and with the triangular flap 100mmHg. Minimum blood pressure with the longitudinal slit was 98mmHg and with the triangular flap 88mmHg. The amount of blood collected for 30 seconds in the conventional longitudinal slit was 1.18mg and in the triangular flap 0.78mg. Histology study in 30 minutes, the conventional longitudinal slit demonstrated the more hemorrhagic features around the suture material compared to that of the triangular. flap and, in the 7th day, the conventional longitudinal slit demonstrated the more prominent granulomatous reactions and vascular proliferations around the suture material compared to that of the triangular flap.

  • PDF

鼻出血에 應用되는 艾柏飮의 效能에 關한 實驗的 硏究 (An Experimental Study on the Effects of Aebaegeum Applicable to the Treatment of Epistaxis)

  • 홍익표;채병윤
    • 한방안이비인후피부과학회지
    • /
    • 제3권1호
    • /
    • pp.1-15
    • /
    • 1990
  • Aebaegeum has been widely used in the treatment of epistaxis, as based on Oriental Medical 1iteratures. In order to investigate experimentally the clinical effects of Aebaegeum, hemostatic time, plasma recalcification time and prothrombin time of hypoprothrombinemia induced by warfarin injection, action on isolated ileum, action on blood vessel, action on blood pressure and respiration and action on heart were observed. The result of the studies were obtained as follows: 1. Hemostatic time of vein ruptured mice was significantly shortened. 2. Plasma recalification time and prothrombin time of hypoprothrombinemic rats induced by warfarin injection were significantly shortened. 3. Spontaneous mobilities in the isolated ileum of mice were significantly suppressed, and contraction by acetylcholine chloride and barium chloride were inhibited. 4. Dilatation of blood vessel and downing of blood pressure of rabbit were noted. 5. Contraction of heart in the original position and isolated heart of frog were significantly shortened. According to the above result, it is expected that Aebaegeum can be widely applicable to the treatment of epistaxis.

  • PDF

Transcranial Doppler를 이용(利用)한 태음인 중풍환자의 혈류속도(血流速度)와 혈관(血管) 반응성(反應性)에 대한 임상적(臨床的) 고찰(考察) (Clinical study of blood flow and vascular reaction in Taeumin CVA patients using Transcranial Doppler)

  • 임종필;배나영;한경수;안택원
    • 혜화의학회지
    • /
    • 제15권2호
    • /
    • pp.263-272
    • /
    • 2006
  • Purpose Brain vessles have autoregulation function, so even when perfusion pressure drops, cerebral blood flow remain stable by vasodilation. Latest research on this reserve of cerebral vessels is being done using TCD, which measures the reserve of the vessels. We did a research comparing cerebral vessel and peripheral vessel reserve between Taeumin, who are more likely to suffer CVA, and the normal. We observed blood flow of Internal carotid artery siphon and radial indicis artery of the two group with TCD. Method We picked 20 people out of patients diagnosed as cerebral infarction at Cheon-An Oriental hospital of Daejeon University. They were diagnosed as Taeumin with QSCCII questionnaire and constitutional differentiation. Using TCD, we measured highest blood flow rate, mean blood flow and asymmetric counting blood flow of Internal carotid artery siphon and radial indicis artery at rest. And then we measured again after stimulating cerebral vessels, by triggering hypercapnia by self apnea and peripheral vessels by palm heating. Result At rest, mean blood flow rate of Internal carotid artery siphon showed significant decrease compared to control group. Blood flow rate of Internal carotid artery siphon after hypercapnia showed significant decline in highest blood flow rate and mean blood flow compared to control group. Cerebral vessel reaction after the hypercapnia induction showed great change in experiment group than the control group. Peripheral vessel reaction after palm heating showed significant decline in experiment group compared to control group. Conclusion In conclusion, measuring the alteration of blood flow used in diagnosing cerebral infarction, is more sensitive when vessel stimulation is done. Non-invasive TCD is effective especially in case of Taeumin who are more likely to suffer vascular disorder than others.

  • PDF