A Study on the Left Ventricular Wall Motion with EKG Gated Cardiac Blood Pool Scan (방사성동위원소(放射性同位元素) gated cardiac blood pool scan을 이용(利用)한 좌심실벽(左心室壁) 운동(運動)에 관(關)한 연구(硏究))

  • Ahn, Yong-Tae;Kim, Byung-Tae;Park, Young-Bae;Lee, Myung-Chul;Cho, Bo-Youn;Seo, Jung-Don;Lee, Young-Woo;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.17 no.2
    • /
    • pp.25-33
    • /
    • 1983
  • Left ventricular wall motion was observed with EKG gated cardiac blood pool scan in 71 various cardiac diseases and 10 normal controls to evaluate its diagnostic and clinical significance in them. 1) In the presence of left ventricular dysfunction, visual evaluation of the left ventricular wall motion was useful to determine whether it was due to localized or diffuse abnormalities. In cardiomyopathy, marked left ventricular dilatation and severe hypokinesia were noted. 2) In myocardial infarction, regional wall motion abnormalities well represented the location of infarcted areas in majority of cases. Patients with inferior wall infarction had smaller decrease of the left ventricular ejection fraction and wall motion grade than anterior or combined groups. In whom persistent left ventricular failure was present, wall motion analysis with gated cardiac scan provided valuable information for the detection of ventricular aneurysms. 3) Evaluation of the left ventricular wall motion and its grading provided a reliable estimate of the left ventricular function. In conclusion, visual evaluation of left ventricular wall motion and its grading provided valuable information for analyzing the characteristics of regional and global left ventricular dysfunction.

  • PDF

Analysis of Left Ventricular Diastolic Function in Coronary Artery Disease with Gated Blood Pool Scan (관상동맥질환에서 Gated Blood Pool Scan을 이용한 좌심실 확장기능의 분석)

  • Choi, Chang-Woon;Lim, Sang-Moo;Chung, June-Key;Lee, Myung-Chul;Park, Young-Bae;Seo, Joung-Don;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.20 no.2
    • /
    • pp.39-45
    • /
    • 1986
  • Resting gated blood pool scan was used to derive left ventricular functional changes in normals (N=13, mean age=43) and in patients with coronary artery disease (N=50, mean age=53). Peak filling rates, average filling rates, and ejection fractions were significantly depressed in coronary artery disease. (p<0.0005, each other). And in coronary artery disease with normal ejection fraction (N=21), peak filling rates and average filling rates were depressed also, and peak filling rates of coronary artery disease with normal ejection fraction were abnormal in 61.2% and average fillin rates were abnormal in 71.4%. It appears that (1) resting peak filling rates and average filling rates were sensitive and easily obtainable parameters of the diastolic dysfunction assosiated with coronary artery disease, (2) a significant proportion of coronary artery disease patients without any evidence of abnormal systolic function have depressed resting peak filling rates and average filling rates of the left ventricle.

  • PDF

The Evaluation of Lateral Scatter Ray of Gamma Camera (Gamma Camera에 있어 측면 선란선의 영향에 대한 평가)

  • Kim, Jae-Il;Lee, Eun-Byeol;Cho, Seong-Wook;Noh, Kyeong-Woon;Kang, Keon-Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.46-50
    • /
    • 2018
  • Purpose Generally, a collimator that installed in front of detector set a direction of gamma ray and remove a scatter ray. By the way, a lateral or oblique scatter ray is detected into crystal through collimator. At this study, we will evaluate a mount of count and spectrums of lateral scatter ray. Materials and Methods We used the SKY LITE (philips, netherlands) as a gamma camera, and $^{99m}Tc$, 1.11 GBq point source as a phantom. we put this point source at backside 50 cm of detector. After acquiring this for 1 min, we turned a detector next 10 degrees. Likely this, we acquired images at every 10 degrees from $0^{\circ}$ to $360^{\circ}$, analyzed images and spectrums. In case of patient study, we choose a 3 phase bone scan patient who had a hand disease, because scatter rays from body would detect on crystal. After acquiring blood flow and blood pool images, we analyzed images and spectrums. Additional, we put a lead gown on patient's hand, body. And then we compared and evaluated 3 type blood pool images (non lead gown, lead gown on a hand and on body). Results In case of phantom study, scatter ray counts at backside ($270^{\circ}-90^{\circ}$) are same with a background count. By the way, counts of scatter ray of oblique side ($0^{\circ}-50^{\circ}$, $220^{\circ}-270^{\circ}$) are 100-600 cps, furthermore, counts at frontside are over 4 Mcps. In case of patient study, a counts of hand blood pool scan are 1510 cps. But counts of hand with lead gown on hands and on body are each 1554 cps, 1299 cps. Conclusion Therefore, even though there is a collimator in front of detector, lateral scatter rays detect on crystal and affect to images and spectrums. Especially, if there is a high activity source at outside of detector when we examine low activity organs like hands or foot, we have to shield and remove the source at outside for a good image.

Measurement of the left ventricular regurgitation by gated cardiac blood pool scan: Before and after valvular replacement surgery (대동맥 및 승모판 판막폐쇄부전증에서 방사성동위원소 심혈관촬영술을 이용한 혈역류량 측정에 관한 연구)

  • Shin, Seong-Hae;Chung, June-Key;Lee, Myung-Chul;Cho, Bo-Youn;Seo, Jung-Don;Lee, Young-Woo;Koh, Chang-Soon;Suh, Kyung-Phill;Lee, Yung-Kyoon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.16 no.2
    • /
    • pp.29-36
    • /
    • 1982
  • Quantification of the regurgitation amount is important before and after valvular replacement surgery. Until now cardiac catheterization with cineventriculography, echocardiography have been used to measure the regurgitation amount, but also have many limitations. EKG gated cardiac blood pool scan provides a simple, non-invasive -method for quantify the regurgitation amount. By calculating the ratio of left ventricular to right ventricular stroke counts (stroke volume ratio) in gated bood pool scan, we measured the left ventricular regurgitation amount in 28 cases of valvular regurgitation and 25 cases of normal group. 1. Stroke volume ratio was higher in cases of valvular regurgitation $(2.11{\pm}0.58)$ than in cases of normal control $(1.15{\pm}0.31)$. (p<0.01). 2. Stroke volume ratio was classified by regurgitation grade using X-ray cineventriculography. In grades of mild regurgitation $(Grade\;I{\sim}II)$, stroke volume ratio was $2.02{\pm}0.29$, and in grades of severe regurgitation $(Grade\;III{\sim}IV)$, stroke volume ratio was $2.55{\pm}0.34$, so stroke volume ratio was well correlated with the grade of X-ray cineventriculography. 3. Stroke volume ratio was classfied by functional class made in New York Heart Association. In classes of mild regurgitation $(class\;I{\sim}II)$, stroke volume ratio was $2.08{\pm}0.26$, and in classes of severe regurgitation $(class\;III{\sim}IV)$, stroke volume ratio was $2.55{\pm}0.38$, Stroke volume ratio well represented the functional class. 4. After aortic and mitral valve replacement in 28 patients, the stroke volume ratio, decreased from $2.11{\pm}0.58\;to\;1.06{\pm}0.26$. Gated blood pool scan provides a noninvasive method of qnantifying valvular regurgitation and assessing the result of surgical interventions.

  • PDF

Usefulness of $^{99m}Tc$-labeled RBC Scan and SPECT in the Diagnosis of Head and Neck Hemangiomas (두경부 혈관종 진단시 $^{99m}Tc$-RBC Scan and SPECT 검사의 유용성)

  • Oh, Shin-Hyun;Roh, Dong-Wook;Ahn, Sha-Ron;Park, Hoon-Hee;Lee, Seung-Jae;Kang, Chun-Goo;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.39-43
    • /
    • 2008
  • Purpose: There are various methods to diagnose hemangioma, such as ultrasonography (US), computed tomography (CT), magnetic resonance imaging (MRI) and nuclear medicine. However, by development of SPECT imaging, the blood-pool scan using $^{99m}Tc$-labeled red blood cell has been used, because it was non-invasive and the most economical method. Therefore, in this study, we proposed that the usefulness of $^{99m}Tc$-RBC scan and SPECT of the head and neck to diagnose unlocated hemangiomas. Materials and Methods: $^{99m}Tc$-RBC scan and SPECT was performed on 6 patients with doubtful hemangioma (4 person, head; 1 person, neck; 1 person, another). We labeled radiopharmaceutical using modified in vivo method and then, centrifuged it to remove plasma. After a bolus injection of tracer, dynamic perfusion flow images were acquired. Then, anterior, posterior, both lateral static blood-pool images were obtained as early and 4 hours delayed. SPECT was progressed 64 projections per 30 seconds. Each image was interpreted by physicians, Nuclear medicine specialist, and technologist blinded to patient's data. Results: In 5 patients of all the radioactivity of doubtful site didn't change in flow images, but, in blood-pool, delayed and SPECT images, it was increased. So, it was a typical hemangioma finding. The size of lesion was over 2 cm, and it could discriminate as comparing to the delayed and SPECT imaging. On the other hand, in 1 patient, the radioactivity was increased in blood-pool images, but, not in delayed and SPECT images, so, it was proved no hemangioma. Conclusion: Using $^{99m}Tc$-RBC Scan and SPECT, we could diagnose the hemangiomas in head and neck, as well as, liver, more non-invasive, economical, and easy. Therefore, it considered that $^{99m}Tc$-RBC scan and SPECT would offer more useful information for diagnosis of hemangioma, rather than otherimaging such as US, CT, MRI.

  • PDF

Incidental Detection of a Pseudoaneurysm at an Amputation Stump in a Tc-99m HMPAO labeled Leukocyte Scan (Tc-99m HMPAO 표지 백혈구스캔상 대퇴 절주에서 우연히 발견된 가성동맥류)

  • Sohn, Myung-Hee;Jeong, Hwan-Jeong;Lim, Seok-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.337-338
    • /
    • 2007
  • A 20-year-old man underwent a Tc-99m HMPAO labeled leukocyte scan for the evaluation of an infection at the stump of an AK amputation, which was conducted due to an open communicated fracture of the left lower leg. Blood-flow and blood-pool images demonstrated a pseudoaneurysm with a focus of intense activity medial to the stump, and centered within a large photopenic defect by surrounding hematoma. Delayed image obtained at 3 hours post-injection showed persistent intense and slight increased activity, Contrast angiography confirmed the presence of a pseudoaneurysm arising from a branch of the left superficial femoral artery.