Non-invasive evaluation of cardiac function by nuclear medicine technologies are one of the major contribution of nuclear medicine. Gated cardiac blood pool scan was once a novel and robust technique which enabled evaluation of ventricular function. Concept of EKG gating was one of the major breakthrough in nuclear cardiology. According to the evolution of echocardiographic techniques, and as the evaluation of myocardial perfusion by perfusion SPECT became feasible, number of gated blood pool study dong in nuclear medicine laboratory is declining. And recently, evaluation of ventricular function with gated perfusion SPECT further decreased the use of gated blood pool scan. In this article, assessment of ventricular function using gated blood pool scan is discussed including some insight about the role of gated blood pool SPECT.
Hemangioma is the most common benign tumor of the liver, with a prevalence estimated as high as 7%. Tc-99m red blood cell (RBC) hepatic blood pool scan with single photon omission computed tomography (SPECT) imaging is extremely useful for the confirmation or exclusion of hepatic hemangiomas. The classic finding of absent or decreased perfusion and increased blood pooling ("perfusion/blood pool mismatch") is the key diagnostic element in the diagnosis of hemangiomas. The combination of early arterial flow and delayed blood pooling ("perfusion/blood pool match") is shown uncommonly. In giant hemangioma, filling with radioactivity appears first in the periphery, with progressive central fill-in on sequential RBC blood pool scan. However, the reverse filling pattern, which begins first in the center with progressive peripheral filling, is also rarely seen. Studies with false-positive blood pooling have been reported infrequently in nonhemangiomas, including hemangiosarcoma, hepatocellular carcinoma, hepatic adenoma, and metastatic carcinomas (adenocarcinoma of the colon, small cell carcinoma of the lung, neruroendocrine carcinoma). False-negative results have been also reported rarely except for small hemagniomas that are below the limits of spatial resolution of gamma camera.
반사성교감신경 이영증후군의 조기 진단에서 삼상 골 스캔이 유용하게 이용된다. 이 질환은 전형적으로 일측 사지관절 전반에 혈류, 혈액풀의 증가와 지연 영상에서 관절의 섭취 증가를 한다. 그러나 통증이 있는 국소부위만 혈류와 혈액풀 검사를 실시하고 있다. 이에 half body 혈액 풀 영상을 추가 검사함으로써 그 유용성을 평가하였다. 2007년 10월부터 2009년 9월까지 부산대병원에서 반사성 교감신경 이영증후군이 의심되는 환자 15명(Male: 8, Female: 7, Mean age: 67.2)을 대상으로 삼상골 스캔을 실시하였다. 그리고 삼상 골 스캔 중 혈액풀상을 얻은 후에 half body scan을 실시하였다. 관심영역은 관류상에서 손과 손목을 포함했고, 혈액풀상에서 손과 손목을 포함한 관심 영역과 견관절을 포함한 관심영역 두가지를 설정하고, 지연상에서는 손과 손목을 포함한 관심영역과 견관절을 포함한 관심영역을 설정 하였다. 손의 관심영역은 국소 영상을 이용했으며, 견관절의 관심 영역은 half body 상과 전신상을 이용하였다. 관심영역을 복사하여 반대측 부위에 설정하여 계수치를 구하여, 우측의 계수를 좌측의 계수로 나눈 섭취비를 우/좌 비로 정하여 계산하였다. 혈류상에서 양측 손의 우/좌 비는 $1.09{\pm}0.53$, 혈액풀상에서 양측 손의 우/좌 비는 $1.13{\pm}0.47$, 지연상에서 양측 손의 우/좌 비는 $1.24{\pm}0.75$이었고, 혈액풀상에서 양측 견관절의 우/좌 비는 $1.08{\pm}0.26$, 지연상에서 양측 견관절의 우/좌 비는 $1.11{\pm}0.31$이었다. Half body 혈액풀상에서 견관절 섭취와 혈류상에서 손과 손목 섭취(R=0.859, p<0.001), 혈액풀상에서 손과 손목 섭취(R=0.886, p<0.0001), 지연상에서 손과 손목 섭취(R=0.855, p<0.001)와 견관절 섭취(R=0.754, p=0.002)는 유의한 상관관계가 있었다. Whole body 지연상에서 견관절 섭취는 혈류상에서 손과 손목 섭취(R=0780, p=0.001), 혈액풀상에서 손과 손목 섭취(R=0.771, p=0.001), 지연상에서 손과 손목 섭취(R=0.705, p=0.005)와 유의한 상관관계가 있었다(Spearman's R, SPSS 12.0). 반사성교감신경 이영증후군은 지연상의 견관절 섭취에서 혈류상, 혈액풀상, 지연상의 손과 손목의 섭취와 유의한 상관관계를 보였다. 뿐만 아니라 혈액풀상에서 half body scan과도 혈류상, 혈액풀상, 지연상의 손과 손목의 섭취와 유의한 상관관계를 보였다. 또한 위 음성과 위 양성을 줄일 수 있을 것이라 기대된다.
Purpose: The scan time reduction helps to yield more accurate results and induce the minimization of patient's motion. Also we can expect that satisfaction of examination will increase. Nowdays medical equipment companies have developed various programs to reduce scan time. We used Onco. Flash (Pixon method, SIEMENS) that is an image processing technique gated cardiac blood pool scan and going to evaluate its clinical usefullness. Materials and Method: We analyzed the 50 patients who were examined by gated blood pool scan in nuclear medicine department of Asan Mediacal Center from June $20^{th}$ 2008 to August $14^{th}$ 2008. We acquired the Full-time (6000 Kcounts) and Half-time (3000 Kcounts) LAO image in same position. And we acquired LVEF values ten times from Full-time, Half-time images acquired by the image processing technique and analyzed its mean and standard deviation values. To estimate LVEF in same conditions, we set automatic location of the LV ROI and background ROI based on same X and Y-axis. Also we performed blinding tests to physician. Results: After making a quantitative analysis of the 50 patients EF values, each mean${\pm}$standard deviation is shown at Full-time image $68.12{\pm}7.84%$, Half- time (acquired by imaging processing technique) $68.49{\pm}8.73%$. In the 95% confidence limit, there was no statistically significant difference (p>0.05). After blinding test with a physician for making a qualitative analysis, there was no difference between Full-time image and Half-time image acquired by the image processing technique for observing LV myocardial wall motion. Conclusion: Gated cardiac blood pool scan has been reported its relatively exact EF measured results than ultrasound or CT. But gated cardiac blood pool scan takes relatively longer time than other exams and now it needs to improve time competitive power. If we adapt Half-time technique to gated cardiac blood pool scintigraphy based on this study, we expect to reduce possible artifacts and improve accessibility as well as flexibility to exam. Also we expect patient's satisfaction.
Gated blood pool scan is frequently used for evaluating the change in cardiac function in various cardiac diseases. But resting gated blood pool scan using only LVEF as a cardiac index has been consitently shown to have a low sensitivity, which is about 50%, in detecting coronary artery disease. So it is recommended to compare exercise gated blood pool scan to resting gated blood pool scan. Exercise tests, however, are not always possible, especially in patients with musculoskeletal diseases, recent myocardial infarction and in elderly persons. We studied the usefulness of resting gated blood pool scan using multiple indices in evaluating the patients with coronary artery disease. Studied cases were 185 patients with coronary artery disease (angina pectoris 31, myocardial infarction 154) and 25 normals with low likelihood of coronary artery disease. We used $^{99m}Tc-labeled$ RBC, 740 MBq labeled by in vivo method. The data were evaluated by Micro DELTA computer program. The results were as following: 1) The ejection rates (PER, AER) and filling rates (PFR, AFR) were different in normls and patients with angina pectoris or myocardial infarction. 2) Mean phase angle, ejection rates and filling rates could separate normals from coronary artery disease patients with normal LVEF. 3) Regional ejection fraction was decreased at the site of the infarct in patients with myocardial infarction. 4) Peak filling rate was the the most detectable index in evaluation of cardiac function in patients with coronary artery disease. 5) The threshold at 1.5 standard deviation of normal range was considered as the most reliable cut-off value from ROC analysis. These data suggest that the resting gated blood pool scan has an important role in the evaluation of cardiac functional changes using various cardiac indices in patients with coronary artery disease.
Purpose: The Gated cardiac blood pool scan is non-invasive method that a quantitative evaluation of left ventricular function. Also this scan have shown the value of radionuclide ejection fraction measurements during the course of chemotherapy as a predictor of cardiac toxicity. Therefore a reliable method of monitoring its cardiotoxic effects is necessary. the purpose of this study is to minimize the overestimate of left ventricular ejection fraction (LVEF) by modified body position to reduce the influence of scattered rays from surrounding organs of the heart in the background region of interest. Materials and Methods: Gated cardiac blood pool scan using in vivo $^{99m}Tc$-red blood cell (RBC) was carried out in 20 patients (mean $44.8{\pm}8.6$ yr) with chemotherapy for a breast carcinoma. Data acquisition requires about 600 seconds and 24 frames of one heart cycle by the multigated acquisition mode, Synchronization deteriorates toward the end of the cycle and with the distance from the trigger signal (R-wave) by ECG gating. Gated cardiac blood pool scan was studied with conventional method (supine position and the detector head in $30-45^{\circ}$ left anterior oblique position and caudal $10-20^{\circ}$ tilt) and compared with modified method (left lateral flexion position with 360 mL of drinking water). LVEF analysis was performed by using the automatically computer mode. Results: The ROI counts of modified scan method were lower than LV conventional method ($1429{\pm}251$ versus $1853{\pm}243$, <0.01). And LVEF of modified method was also decrease compared with conventional method ($58.3{\pm}5.6%$ versus $65.3{\pm}6.1%$, <0.01). Imaging analysis indicated that stomach was expanded because of water and spleen position was changed to lateral inferior compared with conventional method. Conclusion: This study shows that the modified method in MUGA reduce the influence of scattered rays from surrounding organs. Because after change the body position to left lateral flexion and drinking water, the location of spleen, left lobe of liver and stomach had changed and they could escaped from background ROI. Therefore, modified method could help to minimize the overestimate LVEF (%).
Most of clinical morbidity in cardiology are associated with abnormalities of the left ventricle. Several methods have been developed to measure the left ventricular function, including cardiac catheterization with cineangiography, echocardiography, and systolic time interval. But these methods have many limitations. ECG gated cardiac blood pool scan provides a safe, noninvasive, repeatable method for determining the left ventricular function. Utilizing the cardiac blood pool scan, we measured the left ventricular function in 165 cardiac patients, and in 26 normal subject. 1. Left ventricular ejection fractions were measured by cardiac blood pool scan, and compared in 20 patients with that measured by x-ray cineangiography. Correlation coefficient was 0.885. 2. Ejection fractions were classified by funtional class made in New York Heart Association. Ejection fractions well represented the functional status. 3. Ejection fractions decreased in cardiomyopathy ($20.1{\pm}4.8%$) and ischemic heart disease ($34.4{\pm}16.7%$). Impaired ejection fractions in myocardial infarction were associated with the extent of infarction. 4. Regional left ventricular wall motion was evaluated from the end-diastolic and end-systolic images. In cardiomyopathy diffuse hypokinesia was noted and in myocardial infarction akinesia was noted on the infarcted areas.
Attenuated end-diastolic and end-systolic left ventricular counts which obtained from cardiac gated blood pool scan were corrected using experimentally calculated attenuation coefficient $(\mu=0.13/cm)$ and depth of center of left ventricle. This method was confirmed to be correct experimentally using phantom balloon. To compare the accuracy of attenuated and attenuation-corrected left ventricular volume measurement, authors studied 10 patients with ischemic heart disease who underwent both gated blood pool scan and X-ray contrast ventriculography within a week. The attenuated and attenuation-corrected left ventricular volume measured by count method correlated with contrast ventriculographic volumes; however, attenuation corrected measurement was correlated more closely.
레이노 현상에 대한 검사 중 $^{201}Tl$을 이용한 검사에서 관류영상을 composite하여 혈액 풀 영상 과 국소 지연 영상 관찰 및 비교 시의 유용성에 대해서 평가하고자 한다. 2008년 2월부터 2009년 8월까지 레이노 현상을 호소로 경희대학교 동서 신의학병원 혈관외과를 찾은 29명을 대상으로 시행하였다. 방사성 동위원소는 $^{201}Tl$ 111 Mbq (3 mCi)를 검사부위 반대편 팔과 다리의 대각선 사지에 정맥 내 주사하였고, 최초 dynamic 관류 영상과 혈액 풀 영상 그리고 국소지연 영상을 저에너지 고해상도 조준기를 장착한 감마카메라를 이용하여 검사하였다. 보고자 하는 손 또는 발에 대한 관심영역(ROI : Region of Interest)은 관류영상을 composite한 영상과 혈액 풀 영상, 국소 지연 영상 순으로 양측을 동시 분석하였고 대응표본 T 검정(SPSS v12.0)을 이용하여 p-value를 측정하여 데이터의 상관관계를 확인하였다. 분석대상 29명의 레이노 환자(positive)에서 분석된 관류 composite 영상, 혈액 풀 영상, 국소 지연 영상에서 나타난 count ratio(Rt./Lt.)의 평균은 $1.25{\pm}0.39$, $1.20{\pm}0.33$, $1.11{\pm}0.17$이었다. 이를 바탕으로 혈액 풀 영상과 국소 지연 영상의 대응표본 T-검정결과 p<0.029를 만족했고, 또한 관류 composite 영상에 대한 혈액 풀 영상(p<0.038)과 국소 지연 영상 (p<0.016)이 각각 차이가 없음을 알 수 있었다. $^{201}Tl$을 이용한 Raynaud scan에서 관류 영상을 composite함으로써 혈액 풀 영상과 국소 지연 영상을 비교 평가하는데 도움을 줄 수 있었다. 또한 육안적 식별도 가능하여 향후 좀 더 깊이있는 연구가 진행된다면 보다 적절하고 유용한 진단적 정보를 얻을 수 있을 것으로 사료된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.