• Title/Summary/Keyword: blood contamination

검색결과 126건 처리시간 0.025초

The effectiveness of a pre-procedural mouthrinse in reducing bacteria on radiographic phosphor plates

  • Hunter, Allison;Kalathingal, Sajitha;Shrout, Michael;Plummer, Kevin;Looney, Stephen
    • Imaging Science in Dentistry
    • /
    • 제44권2호
    • /
    • pp.149-154
    • /
    • 2014
  • Purpose: This study assessed the effectiveness of three antimicrobial mouthrinses in reducing microbial growth on photostimulable phosphor (PSP) plates. Materials and Methods: Prior to performing a full-mouth radiographic survey (FMX), subjects were asked to rinse with one of the three test rinses ($Listerine^{(R)}$, $Decapinol^{(R)}$, or chlorhexidine oral rinse 0.12%) or to refrain from rinsing. Four PSP plates were sampled from each FMX through collection into sterile containers upon exiting the scanner. Flame-sterilized forceps were used to transfer the PSP plates onto blood agar plates (5% sheep blood agar). The blood agar plates were incubated at $37^{\circ}C$ for up to 72 h. An environmental control blood agar plate was incubated with each batch. Additionally, for control, 25 gas-sterilized PSP plates were plated onto blood agar and analyzed. Results: The mean number of bacterial colonies per plate was the lowest in the chlorhexidine group, followed by the Decapinol, Listerine, and the no rinse negative control groups. Only the chlorhexidine and Listerine groups were significantly different (p=0.005). No growth was observed for the 25 gas-sterilized control plates or the environmental control blood agar plates. Conclusion: The mean number of bacterial colonies was the lowest in the chlorhexidine group, followed by the Decapinol, Listerine, and the no rinse groups. Nonetheless, a statistically significant difference was found only in the case of Listerine. Additional research is needed to test whether a higher concentration (0.2%) or longer exposure period (two consecutive 30 s rinse periods) would be helpful in reducing PSP plate contamination further with chlorhexidine.

Rapid and Sensitive Detection of Hepatitis C Virus in Clinical Blood Samples Using Reverse Transcriptase Polymerase Spiral Reaction

  • Sun, Wenying;Du, Ying;Li, Xingku;Du, Bo
    • Journal of Microbiology and Biotechnology
    • /
    • 제30권3호
    • /
    • pp.459-468
    • /
    • 2020
  • This study established a new polymerase spiral reaction (PSR) that combines with reverse transcription reactions for HCV detection targeting 5'UTR gene. To avoid cross-contamination of aerosols, an isothermal amplification tube (IAT), as a separate containment control, was used to judge the result. After optimizing the RT-PSR reaction system, its effectiveness and specificity were tested against 15 different virus strains which included 8 that were HCV positive and 7 as non-HCV controls. The results showed that the RT-PSR assay effectively detected all 8 HCV strains, and no false positives were found among the 7 non-HCV strains. The detection limit of our RT-PSR assay is comparable to the real-time RT-PCR, but is more sensitive than the RT-LAMP. The established RT-PSR assay was further evaluated for detection of HCV in clinical blood samples, and the resulting 80.25% detection rate demonstrated better or similar effectiveness compared to the RT-LAMP (79.63%) and real-time RT-PCR (80.25%). Overall, the results showed that the RT-PSR assay offers high specificity and sensitivity for HCV detection with great potential for screening HCV in clinical blood samples.

한국 여대생의 혈청과 두발중 아연 함량에 관한 연구 (A Study on the Zinc Concentration in Serum and Hair of Korean Female Collegians)

  • 승정자
    • Journal of Nutrition and Health
    • /
    • 제17권2호
    • /
    • pp.137-144
    • /
    • 1984
  • Due to the fact that blood gathering is not readily accepted by people, it has been difficult to make a full-scale study on zinc through blood analysis. For that reason, in this paper, a correlation of zinc contents in serum and hair was studied to find out whether only hair, which is relatively easy to collect, can be used for a measurement of zinc content. The subjects were 47 healthy female collegians selected at random whose average age was 22, mean height 159.1cm and average weight 49.7kg. The mean zinc value in serum of subjects was ${107.1}\pm{29.0}{\mu}g{/100ml}$, while the mean value in hair was ${150.2}\pm{42.7}ppm$. Correlation analysis shows that there was a significant correlation in zinc contents of serum and hair ( p<0.01). The results shows that measuring zinc level by using only hair samples would be satisfactory. But the use of hair sample for a measurement of zinc level has one demerit. That is, the method is more likely to be subjected to contamination because it makes more complicated procedures in sample preparation than the method of using blood sample.

  • PDF

Effect of Human or Mouse IL-7 on the Homeostasis of Porcine T Lymphocytes

  • Ji Hwa Hong;Sang Hoon Kim;Hyun Gyung Kim;Jun Ho Jang;Ryeo Gang Son;Seung Pil Pack;Young-Ho Park;Philyong Kang;Kang-Jin Jeong;Ji-Su Kim;Hanbyeul Choi;Sun-Uk Kim;Yong Woo Jung
    • IMMUNE NETWORK
    • /
    • 제21권3호
    • /
    • pp.24.1-24.13
    • /
    • 2021
  • Due to the inconsistent fluctuation of blood supply for transfusion, much attention has been paid to the development of artificial blood using other animals. Although mini-pigs are candidate animals, contamination of mini-pig T cells in artificial blood may cause a major safety concern. Therefore, it is important to analyze the cross-reactivity of IL-7, the major survival factor for T lymphocytes, between human, mouse, and mini-pig. Thus, we compared the protein sequences of IL-7 and found that porcine IL-7 was evolutionarily different from human IL-7. We also observed that when porcine T cells were cultured with either human or mouse IL-7, these cells did not increase the survival or proliferation compared to negative controls. These results suggest that porcine T cells do not recognize human or mouse IL-7 as their survival factor.

일부 간호대학생의 혈액매개질환 예방 지침에 대한 지식과 실천 정도 (Knowledge and Performance of Universal Precautions by Nursing Students)

  • 김경미;김민아;정여숙;김남초
    • 대한간호학회지
    • /
    • 제29권4호
    • /
    • pp.929-939
    • /
    • 1999
  • The purpose of this study was to identify knowledge of universal precautions and its performance in practice. The research was conducted from November 2 to 30, 1998. A total 515 student nurses ; 249 from a baccalaureate nursing college and 266 from second and third year of a 3-year community nursing college were surveyed. The results are as following : 1. The average score for universal precautions knowledge was 270.41$\pm$19.43/300(range 150-300). The results showed that 99.2% of students avoid injury from used needles, 98.6% answered that they always wash their hands if they had contact with the patient's blood and they always dispose of used needles in special collectors (97.7%) for needles. But, 39.2% responsed that they dispose of used needles after recapping them. 2. The average score for universal precautions knowledge of the senior students in the 4-year college was the highest (277.65$\pm$13.99). 3. The average score for the performance of universal precautions knowledge was 53.18 $\pm$5.91(range 14-70). The items : ‘I cautiously avoid injury from the used needles’(4.92$\pm$0.33), ‘I always wash my hands if there has been contact with the patient's blood’(4.91$\pm$0.34), and ‘I always disposed of used needles in the appropriate collector’(4.89$\pm$0.42) showed the highest performance. However ‘I always dispose of used needles after recapping them’(2.19$\pm$1.39) and ‘I always use protection goggles when in danger of contamination’(2.19$\pm$1.20) showed low performance level. 4. The highest average score for universal precautions performance was shown among the second year students in 3-year nursing college (54.19$\pm$6.92) between the groups. It showed that the level of the universal precautions performance was higher for those who had education on university precautions prior to performance of the universal precautions than for those without any prior education. 5. The percentage of students who reported the experience of direct contact with patients' blood and/or body fluids was 42.30%. The experience of direct contact with blood and/or body fluids of the educational group was significantly higher than those were not educated. 6. The most frequent cause of the direct contact was ‘needle pricking and/or skin cut’(63.04%). The most frequent substance with which the students contact was ‘blood’(59.85%). The majority of the sample had answered that the mode of contamination was ‘unknown’(63.54%). The majority of the sample answered that strategies used after contamination included ‘washing with soap’(33.61%). Reviewing the chart of patients or asking other health professionals(28.85%). 7. The number of students who had the experience of a needle stick and/or skin cut was 145(28.16%). The clinical practice places where the incidents occurred were mainly in the internal medicine unit (45.07%) and the surgical unit (31.92%) followed by the intensive care unit and the emergency unit in order. The experience of a needle stick and/or skin cut happened during on intra-muscular injection 47.34% and intravenous injection 21.81%. The causes of the needle stick and/or skin cut were ‘putting the needle cap back on 77(35.81%)’. The number of students who took an appropriate post management blood test and/or vaccination was 27(18.62%). 8. The Pearson Correlation Coefficient between the knowledge of universal precautions and performance of universal precautions in practice showed a positive correlation.

  • PDF

연잎 모사 구조로의 초소수성 표면 처리와 의료분야의 적용에 관한 연구 (Fabrication and Medical Applications of Lotus-leaf-like Structured Superhydrophobic Surfaces)

  • 임진익;김승일;정영미;김수현
    • 폴리머
    • /
    • 제37권4호
    • /
    • pp.411-419
    • /
    • 2013
  • 다양한 생체재료들이 이식용 인공장기나 의료용 장비로 폭넓게 사용되고 있으나 혈액과 접촉하는 경우가 많아짐으로써 발생되는 혈전의 문제로 인해 이식재와 혈액간의 혈액 친화성의 향상이 연구자들에게 관심의 대상이 되고 있다. 연잎의 표면구조는 항 오염 특성이라는 측면에서 많은 연구가 진행되어 왔으며, 산업적인 용도로 적용하고자 하는 주된 시도들이 있어 왔다. 대부분 주형법이나 졸-젤 방법, 층 쌓기 방법 등을 포함한 다양한 기법으로 표면처리를 함으로써 인위적인 모사가 가능해 왔다. 최근에 들어 이러한 표면의 초소수성 성질이 의료용 재료의 표면처리 기법으로써 혈관 이식재에서부터 항 박테리아용 표면에까지 널리 적용하려는 시도가 진행되고 있다. 본 리뷰논문에서는 최근 많이 사용되는 연잎 구조로의 표면처리 기법들을 중심으로 요약하였으며, 이들을 이용한 의료분야로의 적용 시도들을 정리하고자 하였다.

소아 대상 혈액배양검사 현황 파악을 위한 국내 다기관 설문조사 (A Multicenter Survey on the Current Status of Pediatric Blood Cultures in Korea)

  • 이영준;이지영;공섬김;연규민;홍유라;오지은
    • Pediatric Infection and Vaccine
    • /
    • 제25권1호
    • /
    • pp.17-25
    • /
    • 2018
  • 목적: 국내에서 소아를 대상으로 시행하는 혈액배양의 적응증과 방법, 정도 관리 현황을 파악하고자 하였다. 방법: 종합병원에 근무하는 소아감염분과 전문의(소아감염)와 신생아집중치료센터를 운영하는 병원에 근무하는 신생아분과 전문의(신생아)를 대상으로 온라인 설문조사를 하였다. 결과: 소아감염의 81.1% (30/37)와 신생아의 72.2% (52/72)가 설문에 응하였다. 적응증과 무관하게 정규 검사로 혈액배양을 실시하는 경우는 소아감염의 33.3%, 신생아의 59.6%였다. 소아감염의 40%와 신생아의 65.4%가 균혈증 의심 환자에서 혈액배양을 1회 시행한다고 했다. 가장 많이 사용되는 피부 소독제는 포비돈-아이오딘이었고, 여러 피부 소독제를 사용하는 경우 그 순서는 기관마다 다양하였다. 배양 양성률 및 오염률을 모니터링하는 기관은 전체의 2/3 정도였으나 결과를 채혈자에게 피드백하는 곳은 적었다. 채혈 담당자에게 정기적인 교육을 하는 곳은 전체의 1/2 이하였다. 결론: 기관별로 혈액배양의 적응증과 방법이 다양하였으며 정도 관리를 적극적으로 시행하는 병원은 적었다. 소아에서 실시되는 혈액배양의 질 향상을 위해 표준 지침의 정립이 필요하며 정도 관리를 위한 기관들의 노력이 요구된다.

Identification of Bacterial Flora on Cellular Phones of Dentists

  • Kwon, Ye Won;Lee, Si Young
    • International Journal of Oral Biology
    • /
    • 제39권3호
    • /
    • pp.137-143
    • /
    • 2014
  • Dental professionals are repeatedly exposed to many microorganisms present in both blood and saliva. Thus, dental professionals are at a greater risk of acquiring and spreading infections, and the implementation of infections control guidelines is necessary. Cellular phones have become a necessary device for communicating in hospitals. Cellular phones contaminated with bacteria may serve as a fomite in the transmission of pathogens by the hands of medical personnel. Nevertheless, studies about rate and levels of bacterial contamination of cellular phones have been extremely limited with regards to dental personnel. The purpose of this study was to identify bacterial flora on the cellular phones of dentists by a molecular biological method using the 16S rRNA cloning and sequencing method. We acquired total 200 clones from dentists' cell phones and identified the bacterial species. Pseudomonas (34.6%), Lactobacillus (18.5%), Azomonas (11.5%), and Janthinobacterium (6%) were the dominant genera on dentists' cell phones. The oral bacteria identified were Anaerococcus lactolyticus, Gibbsiella dentisursi, Lactobacills leiae, Streptococcus mitis, Streptococcus oligofermentans, and Streptococcus sanguinis. Pathogenic bacteria and opportunistic pathogens such as Carnobacterium funditum, Raoultella planticola, Shigella flexneri, Lactobacillus iners, Staphylococcus aureus, and Staphylococcus epidermidis were also identified.

이월오염에 대한 연구 (A Study of Carry Over Contamination in Chematology)

  • 장상우;김남용;류재기;정동진;김기유;박용원;추경복
    • 대한임상검사과학회지
    • /
    • 제37권3호
    • /
    • pp.178-184
    • /
    • 2005
  • Carry over contamination has been reduced in some systems by flushing the internal and external surfaces of the sample probe with copious amount of diluent. It between specimens should be kept as small as possible. A built-in, continuous-flow wash reservoir, which allows the simultaneous washing of the interior and exterior of the syringe needles, addresses this issue. In addition, residual contamination can further be prevented through the use of efficient needle rinsing procedures. In discrete systems with disposable reaction vessels and measuring cuvets, any carry over is entirely caused by the pipetting system. In analyzers with reuseable cuvets or flow cells, carry over may arise at every point through which high samples pass sequentially. Therefore, disposable sample probe tips can eliminate both the contamination of one sample by another inside the probe and the carry over of in specimen into the specimen in the cup. The results of the applicative carry over experiment studied on 21 items for total protein (TP), albumin (ALB), total bilirubin (TB), alkaline phosphatase (ALP), aspratate aminotranferase (AST), alanine aminotranferase (ALT), gamma glutamyl transferase (GGT), creatinine kinase (CK), lactic dehydrogenase (LD), creatnine (CRE), blood urea nitrogen (BUN), uric acid (UA), total cholesterol (TC), triglyceride (TG), glucose (GLU), amylase (AMY), calcium (CA), inorganic phosphorus (IP), sodium (Na), potassium (K), chloride (CL) tests in chematology were as follows. Evaluation of process performance less than 1% in all tests was very good, but a percentage of ALB, TP, TB, ALP, CRE, UA, TC, GLU, AMY, IP, K, Na, and CL was 0%, implying no carry over. Other tests were ALT(-0.08%), GGT(-0.09%), CK(0.08%), LD(0.06%), BUN(0.12%), TG (-0.06%), and CA(0.89%).

  • PDF

착용자 환경 및 시간에 대한 마스크 미생물 오염 연구 (A Study on the Mask Microbial Contamination by Working Environment and Wearing Time)

  • 서혜경;권영일;이성연;강병갑;명준표;장호영;김희주;심수아;박성욱
    • 한국산업보건학회지
    • /
    • 제31권4호
    • /
    • pp.427-439
    • /
    • 2021
  • Objectives: This study aims to investigate differences in microbial contamination according to the duration and environment of mask wearing. Methods: Forty-five participants were recruited from workers in an offices, multi-purpose facilities, and a schools. After wearing of KF94 mask for two. four, and six hours, the microorganisms adsorbed on the outer and inner layers of the mask were inoculated on BAP(Blood Agar Plate), Chocolate agar, and SDA plates. The bacterial count (CFUs: colony-forming units) cultured in each plate was measured and analyzed for changes in filtration efficiency. Results: The microbial contamination of masks worn in classrooms, offices, and multi-purpose facilities showed a significant difference depending on the environment (p<0.000). The measured CFUs increased significantly according to the time wearing the mask. The difference between the inner and outer layers of the mask was also significant (p<0.05). However, there was no statistical difference in the filtration efficiency of the masks by duration time (p=0.515). Conclusions: Masks worn by workers in the offices, multi-purpose facilities, and schools showed an increase of microbial contamination with the amount of time wearing the mask. The results indicate that the masks used in daily life may have adverse health effects if they are worn for a long time or reused over several days without the realizing that the masks can be contaminated with biological hazards. Guidelines on the safe threshold time for mask use should be established through further research.