• Title/Summary/Keyword: blockage ratio

Search Result 119, Processing Time 0.026 seconds

Effect of Blockage Ratio on Wind Tunnel Testing of Small Vertical-Axis Wind Turbines (소형 수직축 풍력발전기 풍동실험시 폐쇄율의 영향)

  • Jeong, Houi-Gab;Lee, Seung-Ho;Kwon, Soon-Duck
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.98-106
    • /
    • 2014
  • The effect of blockage ratio on wind tunnel testing of small vertical-axis wind turbine has been investigated in this study. Height and rotor diameter of the three blades Darrieus vertical axis wind turbine used in present test were 0.4m and 0.35m respectively. We measured the wind speeds and power coefficient at three different wind tunnels where blockage ratio were 3.5%, 13.4% and 24.7% respectively. The test results show that the measured powers have been strongly influenced by blockage ratio, generally increased as the blockage ratio increases. The maximum power at higher blockage ratio has been obtained at relatively high tip speed ratio compared with that at low blockage ratio. The measured power coefficients under high blockage ratio can be improved from proper correction using the simple correction equation based on blockage factor. In present study, the correction error for power coefficient can be less than 5%, however correction effectiveness reveals relatively poor at high blockage ratio and low wind speed.

An Analysis of the Visual Preference on Parallax Space by Blockage Pattern and Ratio (차폐유형과 차폐도를 달리한 패럴랙스(Parallax) 공간의 시각 선호도)

  • Rho, Jae-Hyun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.35 no.2 s.121
    • /
    • pp.55-63
    • /
    • 2007
  • The purpose of this study is to create a planting design for progressive realization. For this, visual preferences as measured via questionnaire were evaluated by the Scenic Beauty Estimation(SBE) and paired comparison methods. The results can be summarized as follows. Through photo observation, the average visual blockage ratio was 38% and the range of degree of the visual blockage ratio was $30{\sim}50%$. The sketch simulation and filtered pattern received the highest preference score and fumed out to be the most practical pattern out of all the patterns evaluated. Also, in the sketch simulation, the high preference values were observed for a distance of 9 to 12m from the view point to the blockage tree with a D/H ratio of 2. The preference score significantly decreased with the increase of the visual blockage ratio having a turning point at $30{\sim}35%$ of the visual blockage ratio, even though the distance parameters were more important than the visual blockage ratio in the scores. An outstanding view must be handled properly to be preserved or accentuated. Framed, open, enclosed, screened or filtered pattern views should be completely revealed only from their best vantage point, not given away at first glimpse. It this sense, parallax spatial beauty with trees could be improved through the visual aspects of plan arrangements and seems to be an effective design technique for landscape planning and planting design.

Shape Design and Prediction of Efficiency of Sedimentation Bed using Three-Dimensional Flow Analysis (삼차원 유동해석을 통한 침전조의 침전효율 예측 및 형상설계)

  • Cui Xiang-Zhe;Kim Hong-Min;Kim Kwang-Yong
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.95-98
    • /
    • 2002
  • Three-dimensional flow analyses for two different ratios of radius to height of sedimentation bed are implemented to evaluate the effect of blockage ratio of center feed wall and angle of distributor on sedimentation efficiency, and to find the optimal value of those parameters. Sedimentation efficiencies for three different shapes are compared with and without rotation speed. And then, five different combinations of blockage ratio of center feed wall and angle of distributor are compared It reveals that the effect of blockage ratio of center fled wall and angle of distributor is considerable to sedimentation efficiency while rotation effect can be neglected and $0.55 and 33^{\circ}$for blockage ratio of center food wall and angle of distributor, respectively, ive the best sedimentation efficiency.

  • PDF

Wind tunnel blockage effects on aerodynamic behavior of bluff body

  • Choi, Chang-Koon;Kwon, Dae-Kun
    • Wind and Structures
    • /
    • v.1 no.4
    • /
    • pp.351-364
    • /
    • 1998
  • In wind tunnel experiments, the blockage effect is a very important factor which affects the test results significantly. A number of investigations into this problem, especially on the blockage correction of drag coefficient, have been carried out in the past. However, only a limited number of works have been reported on the wind tunnel blockage effect on wind-induced vibration although it is considered to be fairly important. This paper discusses the aerodynamic characteristics of the square model and square model with corner cut based on a series of the wind tunnel tests with various blockage ratios and angles of attack. From the test results, the aerodynamic behavior of square models with up to 10% blockage ratio are almost the same and square models with up to 10% blockage ratio can be tested as a group which behaves similarly.

A Study on the Analysis of the Elevation Blockage Ratio in the Conservation of the Coastal Landscape of Jeju (제주시 해안일주도로의 경관보전을 위한 건축물의 입면차폐도 분석에 관한 연구)

  • Park, Chul-Min;Kim, Sung-Hoon
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.6 no.2
    • /
    • pp.31-42
    • /
    • 2004
  • Although the coastal area of Jeju has already been developed, it has high pressure and demands for development continually increasing due to the increase of tourism and leisure activities. Therefore, the purpose of this study is to present objective guidance for the planning of the buildings on the seaside road with a view which have the largest impact on coastal landscape in order to enhance its visual quality. The results of this study are as follows : 1) It is chief element to make guidance for the use and planning of buildings in the conservation of the coastal landscape. 2) The D/H ratios which immediately influence an angle of elevation are different one another for the whole street. To ensure a sense of openness for the landscape, it is needed to maintain under $27^{\circ}$ angle of elevation, which demands 1~3 D/H ratio. 3) It is important to make 2.4 visual blockage ratio for whole street, but the actual condition is 4.48 ratio on average. To bring down the visual blockage ratio, the W/D ratio needs to be regulated. 4) Various techniques are also needed for lively building styles going with coastal landscape.

  • PDF

Effects of the Blockage Ratio of a Valve Disk on Loss Coefficient in a Butterfly Valve (밸브 디스크 차단비 변화가 버터플라이밸브의 손실계수에 미치는 영향에 관한 실험적 연구)

  • Rho, Byung-Joon;Choi, Hee-Joo;Lee, Jee-Keun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.1
    • /
    • pp.39-46
    • /
    • 2008
  • The loss coefficient of the butterfly valve which allows partial opening of the valve at closed position and is applicable to the small-sized pipe system with the diameter of 1 inch was measured for the variation of the valve disk blockage ratio. Two different types of the valve disk configuration to adjust the blockage ratio were considered. One was the solid type valve disk of which the diameter was changed into the smaller size rather than the pipe diameter, and the other was the perforate type valve disk on which some holes were perforated. The results from two types of valve disk were compared to identify their characteristics in the loss coefficient distributions. The loss coefficient and the controllable angle of the valve disk were decreased exponentially with the decrease of the blockage ratio. In addition, the perforate valve disk had the effect on the higher loss coefficient rather than the solid type valve disk.

Large eddy simulation of blockage effects in the assessment of wind effects on tall buildings

  • Gao, Yang;Gu, Ming;Quan, Yong;Feng, Chengdong
    • Wind and Structures
    • /
    • v.30 no.6
    • /
    • pp.597-616
    • /
    • 2020
  • The blockage effect on the aerodynamic characteristics of tall buildings is a fundamental issue in wind tunnel test but has rarely been addressed. To evaluate the blockage effects on the aerodynamic forces on a square tall building and flow field peripherally, large eddy simulations (LES) were performed on a 3D square cylinder with an aspect ratio of 6:1 under the uniform smooth inflow and turbulent atmospheric boundary layer (ABL) inflow generated by the narrowband synthesis random flow generator (NSRFG). First, a basic case at a blockage ratio (BR) of 0.8% was conducted to validate the adopted numerical methodology. Subsequently, simulations were systematically performed at 6 different BRs. The simulation results were compared in detail to illustrate the differences induced by the blockage, and the mechanism of the blockage effects under turbulent inflow was emphatically analysed. The results reveal that the pressure coefficients, the aerodynamic forces, and the Strouhal number increase monotonically with BRs. Additionally, the increase of BR leads to more coherence of the turbulent structures and the higher intensity of the vortices in the vicinity of the building. Moreover, the blockage effects on the aerodynamic forces and flow field are more significant under smooth inflow than those under turbulent inflow.

Study on the influence of flow blockage in severe accident scenario of CAP1400 reactor

  • Pengcheng Gao;Bin Zhang ;Jishen Li ;Fan Miao ;Shaowei Tang ;Sheng Cao;Hao Yang ;Jianqiang Shan
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.999-1008
    • /
    • 2023
  • Deformed fuel rods can cause a partial blockage of the flow area in a subchannel. Such flow blockage will influence the core coolant flow and further the core heat transfer during the reflooding phase and subsequent severe accidents. Nevertheless, most of the system analysis codes simulate the accident process based on the assumed flow blockage ratio, resulting in inconsistencies between simulated results and actual conditions. This paper aims to study the influence of flow blockage in severe accident scenario of the CAP1400 reactor. First, the flow blockage model of ISAA code is improved based on the FRTMB module. Then, the ISAA-FRTMB coupling system is adopted to model and calculate the QUENCH-LOCA-0 experiment. The correctness and validity of the flow blockage model are verified by comparing the peak cladding temperature. Finally, the DVI Line-SBLOCA accident is induced to analyze the influence of flow blockage on subsequent CAP1400 reactor core heat transfer and core degradation. From the results of the DVI Line-SBLOCA accident analysis, it can be concluded that the blockage ratio is in the range of 40%-60%, and the position of severe blockage is the same as that of cladding rupture. The blockage reduces the circulation area of the core coolant, which in turn impacts the heat exchange between the core and the coolant, leading to the early failure and collapse of some core assemblies and accelerating the core degradation process.

Interactions Between a Propagating Flame and Rectangular Wall Obstacles in a Rectangular Confinement (직사각형 폭발 챔버에서 화염전파와 직사각형 장애물의 상관관계)

  • Park, Dal-Jae;Lee, Tae-Sung;Lee, Young-Soon
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.2
    • /
    • pp.81-86
    • /
    • 2008
  • Experimental studies have been performed to examine the influences of wall obstructions in a rectangular confinement. Three wall obstacles with blockage ratios ranging from 10 to 30% were used. Temporally resolved flame front images were recorded by a high-speed video camera to investigate the interaction between a propagating flame and the obstacle. The local flame displacement speed and its probability density functions(PDFs) were obtained for the wall obstructions. During the interaction with the sharp-edges of the wall obstacles, the local propagation speed increased. The increase of local speed became larger as the obstruction ratio increased. However, the averaged flame displacement speeds with different blockage ratios were not significantly different within the chamber as shown in the paper of Park et al. The flame front interaction investigated in this work was less dependent of the obstacle obstructions compared to that published in the literature for large L/D.

CFD analysis of the flow blockage in a rectangular fuel assembly of the IAEA 10 MW MTR research reactor

  • Xia, Shuang;Zhou, Xuhua;Hu, Gaojie;Cao, Xiaxin
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.2847-2858
    • /
    • 2021
  • When a nuclear reactor with rectangular fuel assemblies runs for a long time, impurities and debris may be taken into coolant channels, which may cause flow blockage, and the blocked fuel assemblies might be destroyed. Therefore, the purpose of this study is to perform a thermal-hydraulic analysis of a rectangular fuel assembly by STAR-CCM+, under the condition of one subchannel with 80% blockage ratio. A rectangular fuel assembly of the International Atomic Energy Agency (IAEA) 10 MW material test reactor (MTR) is chosen. In view of the gasket material taken into the coolant channel is close to the single side of the coolant channel, in the flow blockage accident of the Oak Ridge Research Reactor (ORRR), a new blockage category called single side blockage is attempted. The blockage positions include inlet, middle and outlet, and the blockage is set as a cuboid. It is found by simulations that the blockage redistributes the mass flow rate, and large vortices appear locally. The peak temperature of the cladding is maximum, when the blockage is located at the single side of the coolant channel inlet, and no boiling occurs in all blockage cases. Moreover, as the height of the blockage increases, the damage caused by the blockage increases slightly.