A Study on the Flow and Cooling Characteristics with the Inlet Blockage of a Fan-Sink (홴싱크의 입구 봉쇄에 따른 유동 및 냉각 특성에 관한 연구)

  • Lee, Kyoung-Yong;Choi, Young-Seok;Yun, Jae-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.83-88
    • /
    • 2004
  • In this study, the flow and thermal performance of the heat sink and fan-sink were experimentally studied to predict the operating condition of the fan-sink. The experiments of the flow and thermal resistance of the heat sink with various inlet blockage, which were occurred by the shapes of the axial fans, were conducted for the proof of the effects of the inlet blockages. The greater the inlet blockage of the heat sink, the higher the pressure drop and lower the thermal resistance of the heat sink will be. The operating point of the fan-sink was predicted by the pressure drop curve with the inlet blockage, which was corresponded to the selected fan and the fan performance curve, and verified by the performance test of the fan-sink. The predicted operating point of the fan-sink had good agreement with the result of the performance test of the fan-sink within $0.7\%$ of the volume flow rates. Measured thermal resistance of the fan-sink was equivalent to that of the heat sink with the same inlet blockage of the fan-sink. It was shown that the heat transfer characteristics of the heat sink were influenced by the flow interaction between the selected fan and the heat sink. To improve the thermal resistance of the heat sink, it is necessary to consider appropriate flow patterns of the fan outlet entering into the heat sink.

  • PDF

Steady Flow Characteristics of Flow-Intensifying Valve Configurations (유동 강화형 밸브의 형상에 따른 정상 유동 특성)

  • Choi, Su-Jin;Ryoo, Ki-Hyun;Jeon, Chung-Hwan;Chang, Young-June
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.2
    • /
    • pp.166-174
    • /
    • 1999
  • The flow characteristics of 2-valve and 4-valve cylinder heads with various blocked-valve were experimentally investigated in a steady flow rig. Effects of the blocked-valve configurations on flow coefficient, swirl and tumble intensity are studied. Compared to the conventional valve, the blocked valve in both cylinder heads have the much lower flow coefficient and the much higher intensity of swirl and tumble. Under the same size of blockage, the value of flow coefficient and swirl(or tumble) intensity were varied according to the position of blockage. Throughout these steady flow test the optimized positions of blockage in both cylinder heads were determined.

Numerical and Experimental Studies for the Design of High Efficiency Sedimentation Bed (고효율 침전조 설계를 위한 실험 및 수치해석)

  • Kim, Hong-Min;Choi, Sang-Cheol;Kim, Kwang-Yong;Kim, Byung-Hee;Lim, Young-Taek
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.2 s.19
    • /
    • pp.54-61
    • /
    • 2003
  • Both numerical and experimental studies on the sedimentation efficiency of a sedimentation bed were carried out. Three different structures of sedimentation bed and five different combinations of blockage ratio of center feed wall and angle of distributor are implemented to find the optimal values of geometric parameters. The effect of rotation of the distributor on sedimentation efficiency is also investigated. It reveals that the effects of blockage ratio and angle of distributor on sedimentation efficiency are considerable, while rotation effect can be neglected, and that calculated efficiencies show good agreements with those of experiment, qualitatively.

A Study on the Performance Characteristics of the Sirocco Fan in a Range Hood (레인지 후드용 시로코 홴 성능 특성에 관한 연구)

  • Park, Sang-Tae;Choi, Young-Seok;Park, Moon-Soo;Kim, Cheol-Ho;Kwon, Oh-Myoung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.2 s.29
    • /
    • pp.9-15
    • /
    • 2005
  • This paper presents an experimental and numerical study on the overall performance and local flow characteristics of sirocco fan in a range hood. Measurement of overall performance for sirocco fans were conducted based on AMCA standard 210. The effects of flow blockages due to the motor inside the fan on the fan performance were investigated by experimentally and numerically and the results were compared with each other. The numerical and experimental results show the inlet flow blockage reduces the performance (ie. fan static pressure, design flow rate, maximum efficiency and free delivery flow rate) of fan. It is found that the blockage makes the flow field highly non-uniform through the blade and cause the efficiency decrement.

An Experimental Study on the Effects of Design Factors for the Performance of Fin-Tube Heat Exchanger Under Frosting Conditions (착상시 설계인자에 따른 핀-관 열교환기의 성능변화에 관한 실험적 연구)

  • 이관수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.10
    • /
    • pp.2657-2666
    • /
    • 1995
  • In this study, the effects of design factors of finned-tube heat exchanger, such as fin spacing and fin array on the frost growth and heat exchanger performance are investigated under a frosting condition. The results show that the amount of frost, frost density and blockage ratio of air flow passage increase with decreasing fin spacing. Heat transfer rate increases momentarily at the initial stage of frosting and then decreases. After that heat transfer rate continues to increase again to reach a maximum value and then decreases dramatically. It is shown that the time required for heat transfer rate to reach a maximum value becomes shorter with decreasing fin spacing, and after a maximum value, heat transfer rate decreases very fast. The maximum allowable blockage ratio is introduced to determine the operation limit of a finned-tube heat exchanger operating under frosting condition and is obtained as a function of fin spacing. It is also shown that heat transfer rate of heat exchanger with staggered fin array increases about 17% and the amount of pressure drop of air increases about 1~2 mmH$_{2}$O, compared with those of in-line type heat exchanger under frosting condition.

Study of the Resistance Test and Wall Blockage Correction Method for the Submerged Body in LCT (대형 캐비테이션터널에서 몰수체 저항시험 및 위벽효과 수정 기법 연구)

  • Ahn, Jong-Woo;Seol, Han-Shin;Park, Young-Ha;Kim, Ki-Sup
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.57 no.3
    • /
    • pp.133-139
    • /
    • 2020
  • In order to study the resistance test technique for the submerged body in Large Cavitation Tunnel (LCT), DARPA Suboff, submarine model publicly available was manufactured. DTRC released the resistance test data of DARPA Suboff conducted at ship speeds up to 18.0 knots in high-speed towing tank in 1990. As LCT is considered restricted waterways with walls, the resistance test results must be corrected with three wall blockage effects called buoyancy effect, solid blockage effect and wake blockage effect. Before correction, the resistance of LCT was 16~20 % higher than that of DTRC. After correction, the resistance and the resistance coefficients were compared with those of DTRC. The corrected resistance of LCT shows good agreement with that of DTRC. The residual resistance coefficient shows the difference according to the calculation method of buoyancy and frictional resistance coefficient. This paper suggests the best way for the calculation of residual resistance coefficient, On the basis of the present study, it is thought that the operating conditions for the propeller cavitation and noise tests can be drawn through LCT tests.

Nucleate Pool Boiling Heat Transfer in Vertical Annuli (수직 환상 공간 내부의 풀핵비등 열전달)

  • Gang, Myeong-Gi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.8
    • /
    • pp.1113-1121
    • /
    • 2001
  • Effects of gap sizes(3.9 and 15mm) of vertical annuli and the bottom blockage on the nucleate pool boiling heat transfer at atmospheric pressure condition have been examined experimentally, and the results were compared to those with a single tube without confinement. The annular geometry resulted in significant increase in heat transfer coefficient. The effect is much enhanced with the bottom blockage. The heat transfer coefficient for the closed bottom condition is three times greater than the unconfined tube at 30kW/㎡ when the gap size is 3.9mm. However, with further increase of the heat flux much more than 70kW/㎡, all these effects were diminished.

An experimental investigation of artificial supercavitation generated by air injection behind disk-shaped cavitators

  • Ahn, Byoung-Kwon;Jeong, So-Won;Kim, Ji-Hye;Shao, Siyao;Hong, Jiarong;Arndt, Roger E.A.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.9 no.2
    • /
    • pp.227-237
    • /
    • 2017
  • In this paper, we investigated physical characteristics of an artificial supercavity generated behind an axisymmetric cavitator. Experiments for the same model were carried out at two different cavitation tunnels of the Chungnam National University and the University of Minnesota, and the results were compared and verified with each other. We measured pressures inside the cavity and observed the cavity formation by using a high-speed camera. Cavitation parameters were evaluated in considering blockage effects of the tunnel, and gravitational effects on supercavity dimensions were examined. Cavity dimensions corresponding to the unbounded cavitation number were compared. In addition, we investigated how artificial supercavitation develops according to the combination of injection positions and direction.

Multiple Residues in the P-Region and M2 of Murine Kir 2.1 Regulate Blockage by External $Ba^{2+}$

  • Lee, Young-Mee;Thompson, Gareth A.;Ashmole, Ian;Leyland, Mark;So, In-Suk;Stanfield, Peter R.
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.13 no.1
    • /
    • pp.61-70
    • /
    • 2009
  • We have examined the effects of certain mutations of the selectivity filter and of the membrane helix M2 on $Ba^{2+}$ blockage of the inward rectifier potassium channel, Kir 2.1. We expressed mutant and wild type murine Kir 2.1 in Chinese hamster ovary(CHO) cells and used the whole cell patch-clamp technique to record $K^+$ currents in the absence and presence of externally applied $Ba^{2+}$. Wild type Kir2.1 was blocked by externally applied $Ba^{2+}$ in a voltage and concentration dependent manner. Mutants of Y145 in the selectivity filter showed little change in the kinetics of $Ba^{2+}$ blockage. The estimated $K_d(0)$ was 108 ${\mu}M$ for Kir2.1 wild type, 124 ${\mu}M$ for a concatameric WT-Y145V dimer, 109 ${\mu}M$ for a WT-Y145L dimer, and 267 ${\mu}M$ for Y145F. Mutant channels T141A and S165L exhibit a reduced affinity together with a large reduction in the rate of blockage. In S165L, blockage proceeds with a double exponential time course, suggestive of more than one blocking site. The double mutation T141A/S165L dramatically reduced affinity for $Ba^{2+}$, also showing two components with very different time courses. Mutants D172K and D172R(lining the central, aqueous cavity of the channel) showed both a decreased affinity to $Ba^{2+}$ and a decrease in the on transition rate constant(${\kappa}_{on}$). These results imply that residues stabilising the cytoplasmic end of the selectivity filter(T141, S165) and in the central cavity(D172) are major determinants of high affinity $Ba^{2+}$ blockage in Kir 2.1.