• Title/Summary/Keyword: block Motion

Search Result 902, Processing Time 0.018 seconds

The study of Intercostal Nerve Block and Patient-Controlled Analgesia for Post-Thoracotomy Pain (개흉술 후 동통억제에 대한 신경차단법 및 환자자가 치료법의 비교연구)

  • 김우종;이길노
    • Journal of Chest Surgery
    • /
    • v.30 no.9
    • /
    • pp.920-926
    • /
    • 1997
  • Remarkable effect of pain relief and prevention of the postoperative Complications after thoracotomy has been achieved by continuous intravenous analgesia. This study was carried out with thirty patients who underwent posterolateral thoraco tony. The patients were divided into three groups: Group I(n= 10), the patients with intermittent intramuscular analgesia(piroxicam 20 mg), Group II(n=10), the patients with continuous epidural analgesia(0.5% bupivacaine 30m1 + normal saline 30 ml + morphine 10 mg), and Group III(n= 10) the patients with controlled intravenous infusion of analgesics(fentanyl 2500 mfg +normal saline 10 ml). The results w re as follows; 1) There were no significant changes of vital signs, between groups. 2) Tidal volume and FVC were significantly improved in the group II and III compared with the group I during the first postoperative day. 3) A significant reduction of immediate post-thoracotomy pain was achieved in the group II and III compared with the group I. 4) The limitation of motion in the operative side was less in the group II and III compared with the group I. 5) A signi(icant reduction of the postoperative analgegics consumption was noticed in group II and III. 6) Significant complications were not occured during follow-up period in all groups.

  • PDF

Evaluation of difference in respiratory phase between amplitude- and phase-based four-dimensional computed tomography (위상 기반 사차원전산화단층촬영과 진폭 기반 사차원전산화단층촬영 영상에서의 위상차 평가)

  • Lee, So Hyang;Park, Soo Yeon;Kim, Jong Sik;Choi, Byung Ki;Park, Hee Chul;Jung, Sang Hoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.73-78
    • /
    • 2015
  • Purpose : Under the assumption of change to the amplitude based sorting, the study will use four dimensional computed tomography imaging (4DCT) arrayed using the phase based sorting to analyze the respiratory phase difference. Materials and Methods : The study analyzed the 4DCT (4-dimensional computed tomography) images of 10 liver cancer patients that were treated with respiratory gated radiotherapy from 2015 February to March. Using RPM respiratory gating (RPM 1.7.5, Varian, USA) equipment, imaging according to respiratory cycle of phase based sorting was acquired and using a treatment planning system (Pinnacle 9.2, Philips, USA) the acquired imaging according to respiratory cycle was used to measure the abdominal movement value by respiratory cycle. The measuring point was the point where the center point of the Marker Block and the body surface met in the 50% phase image and here the coordinate values Lateral, Vertical, Longitudinal (X, Y, Z) were set as reference points, and on the X, Z plane identical to the reference point, using the identical method the Y axis coordinate value of each 0%, 30%, 40%, 50%, 60%, 80% phase images were acquired to quantitatively measure the variation of distance to the Y axis. The abdominal movement value according to respiration was applied to the theoretical model that the value decreases linearly from maximum inhalation to maximum exhalation to divide the variation of my value to predict as amplitude value by respiratory cycle and conversely the variation in amplitude was recalculated with the phase variation deviation value to analyze. Results : The deviation value between expected value and actual location was the largest in the 30% phase with 0.24 cm, and standard deviation was also the largest in 30% phase with 0.13 cm. The effective value of the deviation value derived from the average of the deviation squared value of each patient appeared as minimum 0.7 cm, maximum 0.18 cm, average 0.12 cm, and standard deviation 0.4 cm. Also by dividing the actual movement distance value with the peak expiration value then converting it into %Phase, the deviation value with actual phase 16.5% in 30% phase, 10.0% and 40% phase, 10.0% and 60% phase, 15.4% and 80% phase, and overall average about 13%, and arraying based on amplitude, phase shift occurred and further it was from peak expiration the chance of deviation occurrence was increasingly measured. Conclusion : Based on the results of the study there were differences between value acquired based on theoretical model and actual value. Therefore in respiratory gated radiotherapy using external surrogates, there needs to be establishment of respiration gated radiation system that avoids the combination of two Sorting methods considering that there will be occurrence of treatment and corresponding clinical differences due to the phase difference that occur due to the Amplitude based Phase Sorting.

  • PDF