• Title/Summary/Keyword: blended fuel

Search Result 246, Processing Time 0.017 seconds

A Study on Chloride Threshold Level of Blended Cement Mortar Using Polarization Resistance Method (분극저항 측정기법을 이용한 혼합 시멘트 모르타르의 임계 염화물 농도에 대한 연구)

  • Song, Ha-Won;Lee, Chang-Hong;Lee, Kewn-Chu;Ann, Ki-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.3
    • /
    • pp.245-253
    • /
    • 2009
  • The importance of chloride ions in the corrosion of steel in concrete has led to the concept for chloride threshold level (CTL). The CTL can be defined as the content of chlorides at the steel depth that is necessary to sustain local passive film breakdown and hence initiate the corrosion process. Despite the importance of the CTL, due to the uncertainty determining the actual limits in various environments for chloride-induced corrosion, conservative values such as 0.4% by weight of cement or 1.2 kg in 1 $m^3$ concrete have been used in predicting the corrosion-free service life of reinforced concrete structures. The paper studies the CTL for blended cement concrete by comparing the resistance of cementitious binder to the onset of chloride-induced corrosion of steel. Mortar specimens were cast with centrally located steel rebar of 10 mm in diameter using cementitious mortars with ordinary Portland cement (OPC) and mixed mortars replaced with 30% pulverized fuel ash (PFA), 60% ground granulated blast furnace slag (GGBS) and 10% silica fume (SF), respectively, at 0.4 of a free W/B ratio. Chlorides were admixed in mixing water ranging 0.0, 0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0, 2.5 and 3.0% by weight of binder(Based on $C1^-$). Specimens were curd 28 days at the room temperature, wrapped in polyethylene film to avoid leaching out of chloride and hydroxyl ions. Then the corrosion rate was measured using the polarization resistance method and the order of CTL for binder was determined. Thus, CTL of OPC, 60%GGBS, 30%PFA and 10%SF were determined by 1.6%, 0.45%, 0.8% and 2.15%, respectively.

A Study on the Characteristics of Condensable Fine Particles in Flue Gas (배출가스 중 응축성미세먼지 특성 연구)

  • Gong, Buju;Kim, Jonghyeon;Kim, Hyeri;Lee, Sangbo;Kim, Hyungchun;Jo, Jeonghwa;Kim, Jeonghun;Gang, Daeil;Park, Jeong Min;Hong, Jihyung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.5
    • /
    • pp.501-512
    • /
    • 2016
  • The study evaluated methods to measure condensable fine particles in flue gases and measured particulate matter by fuel and material to get precise concentrations and quantities. As a result of the method evaluation, it is required to improve test methods for measuring Condensable Particulate Matter (CPM) emitted after the conventional Filterable Particulate Matter (FPM) measurement process. Relative Standard Deviation (RSD) based on the evaluated analysis process showed that RSD percentages of FPM and CPM were around 27.0~139.5%. As errors in the process of CPM measurement and analysis can be caused while separating and dehydrating organic and inorganic materials from condensed liquid samples, transporting samples, and titrating ammonium hydroxide in the sample, it is required to comply with the exact test procedures. As for characteristics of FPM and CPM concentrations, CPM had about 1.6~63 times higher concentrations than FPM, and CPM caused huge increase in PM mass concentrations. Also, emission concentrations and quantities varied according to the characteristics of each fuel, the size of emitting facilities, operational conditions of emitters, etc. PM in the flue gases mostly consisted of CPM (61~99%), and the result of organic/inorganic component analysis revealed that organic dusts accounted for 30~88%. High-efficiency prevention facilities also had high concentrations of CPM due to large amounts of $NO_x$, and the more fuels, the more inorganic dusts. As a result of comparison between emission coefficients by fuel and the EPA AP-42, FPM had lower result values compared to that in the US materials, and CPM had higher values than FPM. For the emission coefficients of the total PM (FPM+CPM) by industry, that of thermal power stations (bituminous coal) was 71.64 g/ton, and cement manufacturing facility (blended fuels) 18.90 g/ton. In order to estimate emission quantities and coefficients proper to the circumstances of air pollutant-emitting facilities in Korea, measurement data need to be calculated in stages by facility condition according to the CPM measurement method in the study. About 80% of PM in flue gases are CPM, and a half of which are organic dusts that are mostly unknown yet. For effective management and control of PM in flue gases, it is necessary to identify the current conditions through quantitative and qualitative analysis of harmful organic substances, and have more interest in and conduct studies on unknown materials' measurements and behaviors.

Rheological behavior study of Marine Lubricating oil on the amount of MGO (Marine Gas Oil) dilution (해상용 경유의 희석량에 따른 선박용 윤활유의 유변학적 거동연구)

  • Song, In Chul;Lee, Young Ho;Yeo, Young Hwa;Ahn, Su Hyun;Kim, Dae il
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.2
    • /
    • pp.240-245
    • /
    • 2016
  • This paper describes the rheological behavior study such as viscosity and change of shear stress regarding marine lubricating oil according to the amount of Marine Gas Oil (MGO) dilution. The viscosity reduction due to fuel dilution is crucially important characteristic to decreasing engine durability because of the abrasion of piston ring or liner. The lubricating oil used in this paper was blended with magnetic stirrer diluted High Sulfur Diesel (HSD, 0.05 wt%) ratio of 3 %, 6 %, 10 %, 15 % and 20 %. The viscosity and shear stress of diluted lubricating oil were measured with the temperature range from $-10^{\circ}C$ to $80^{\circ}C$ using a rotary viscometer (Brookfield Viscometer). As the amount of MGO dilution increasing in lubricating oil, the viscosity and stress of those decreased, because the lubricating oil diluted MGO with low viscosity show the trends to decreased viscosity and shear stress. Especially, the viscosity and shear stress of lubricating oil radically decreased at low temperature ($0{\sim}-10^{\circ}C$) and doesn't effect in MGO dilution at over $40^{\circ}C$. As temperature risen, the reduction of the viscosity and shear stress in lubricating oil shows the Newtonian behavior. The lubricating oil was required to check up periodically to improve engine durability since the viscosity reduction by MGO dilution accelerating the engine abrasion.

The SIMDIST (Simulated Distillation) Analysis of Distributing Engine Oil (국내 유통 엔진오일 고온모사증류시험 분석)

  • Lim, Young-Kwan;Kim, Jiyeon;Kim, Jong-Ryeol;Ha, Jong-Han
    • Applied Chemistry for Engineering
    • /
    • v.28 no.6
    • /
    • pp.632-637
    • /
    • 2017
  • The vehicle lubricant occupies upto 35% in a total lubricant market and engine oil occupies upto 77% in the vehicle lubricant market in Korea. A suitable quality management of the circulating engine oil is necessary for driver and engine protection. But, KS and synthetic engine oil products (involved over 30% synthetic oil) are exempt to any quality management under Petroleum and Alternative Fuel Business Act. It is also known that synthetic oils such as PAO (poly alpha olefin) have excellent properties and performance like anti-wear, varnish control and oxidation stability than those of mineral oils. For this reason, PAO has been used for an engine oil, rotary screw and reciprocating compressor in addition to heavy duty and other extreme service applications. In this study, our research group analyzed the chromatogram pattern for the mineral oil, PAO and mineral oil involved a typical ratio of PAO using SIMDIST (simulated distillation). In the SIMDIST chromatogram, the mineral oil showed a broad peak, while PAO showed a sharp typical peak. Also the oil with a large viscosity grade exhibited a long retention time due to the heavy molecular weight and high boiling point. In particular, the blended mineral oil with 20% PAO sample showed a distinctly different pattern compared to that of using the conventional mineral oil. For monitoring PAO contents in distributing engine oils, we analyzed the SIMDIST for 27 kinds of engine oils which were popularly sold in Korea. The analytic results indicate that all kinds of engine oils showed that PAO contents were below 20% in engine oil products. Moreover, the PAO titled product was found to have a small amount of PAO. Thus, we conclude that the related laws for the proper quality management of synthetic oils are needed to be established.

Chloride Threshold Value for Steel Corrosion considering Chemical Properties of Concrete (콘크리트의 화학적 특성을 고려한 철근 부식 임계 염소이온 농도)

  • Song, Ha-Won;Jung, Min-Sun;Ann, Ki Yong;Lee, Chang-Hong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.1A
    • /
    • pp.75-84
    • /
    • 2009
  • The present study assesses the chloride threshold level for corrosion of steel in concrete by examining the properties of four different binders used for blended concrete in terms of chloride binding, buffering of cement matrix to a pH fall and the corrosion behaviour. As binders, ordinary Portland cement (OPC), 30% pulverised fuel ash (PFA), 60% ground granulated blast furnace slag (GGBS) and 10% silica fume (SF) were used in a concrete mix. Testing for chloride binding was carried out using the water extraction method, the buffering of cement matrix was assessed by measuring the resistance to an artificial acidification of nitric acid, and the corrosion rate of steel in mortar with chlorides in cast was measured at 28 days using an anodic polarisation technique. Results show that the chloride binding capacity was much affected by $C_{3}A$ content and physical adsorption, and its order was 60% GGBS>30% PFA>OPC>10% SF. The buffering of cement matrix to a pH fall was varied with binder type and given values of the pH. From the result of corrosion test, it was found that the chloride threshold ranged 1.03, 0.65, 0.45 and 0.98% by weight of cement for OPC, 30% PFA, 60% GGBS and 10% SF respectively, assuming that corrosion starts at the corrosion rate of $0.1-0.2{\mu}A/cm^{2}$. The mole ratio of [$Cl^{-}$]:[$H^{+}$], as a new presentation of the chloride threshold, indicated the value of 0.008-0.009, irrespective of binder, which would be indicative of the inhibitive characteristic of binder.

Development of Convergence Education (STEAM) Program for High School Credit System (고교학점제를 위한 융합교육(STEAM) 프로그램 개발)

  • Kwon, Hyuksoo;Kim, Eojin;Kim, Jaewoon;Min, JaeSik;Bae, SangIl;Son, MiHyun;Lee, Hyonyong;Choi, JinYoung;Han, MiYoung;Ham, HyungIn
    • Journal of Science Education
    • /
    • v.46 no.1
    • /
    • pp.93-108
    • /
    • 2022
  • The purpose of this study is to develop a STEAM program that can be used in the high school credit system to be fully implemented in 2025, and to examine its validity and effectiveness. The STEAM program analyzed the 2015 revised curriculum centering on science, technology, and engineering through the 2015 revised curriculum analysis, and then selected the five latest issues: hydrogen fuel, climate crisis, data science, appropriate technology, and barista. In accordance with this self-developed program development format (frame), it was developed for seven months through a process of group deliberation. The draft of the STEAM program for 29 sessions of five types, developed to indirectly experience the career path and occupation of high school students, was verified through consultation with 2 STEAM education experts. It was applied at five different high schools for a pilot implementation. As a result of the pilot application, it was confirmed that the students' STEAM attitude significantly improved in the post-test than the pre-test, and the students' high satisfaction with the program was confirmed. In addition, through an interview with the pilot application teacher, it was positively evaluated that 'the content and level of the program are suitable and through experience solving real-life problems, you can apply the content knowledge of related subjects and have an opportunity to experience careers.' Based on the results of the pilot application, the high school credit system STEAM program for students and teachers was finally completed in 29 lessons of five types. Through this study, the development and operation of the next-generation STEAM program that can be applied in the high school credit system should be actively developed, and a plan to improve teachers' professionalism so that the high school credit system can be established and operated properly for blended classes triggered by COVID-19. The necessity of design was suggested. This study is expected to be used as basic data for the development and operation of STEAM programs in the high school credit system, which will be fully implemented in 2025.