• Title/Summary/Keyword: blade position

Search Result 134, Processing Time 0.02 seconds

Wake Analysis of the HAWT by Windtunnel Test (실험을 통한 풍력발전기의 후류구조 분석)

  • Park, Ji-Woong;Kim, Ho-Geon;Shin, Hyung-Ki;Lee, Soo-Gab
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.273-276
    • /
    • 2006
  • To generate electricity from wind energy, wind turbine generally has a rotor blade. Since this rotor blade is a kind of the rotating machinery, the wake from the rotor is very Important role in the side of the aerodynamic performances. Thus the study about wake is essential to analyze wind turbine aerodynamics. In this study wake characteristics are analyzed by hot-wire probe in the K.A.F.A(Korea Air Force Academy) wind tunnel. It is possible to analyze the wake characteristics by hot-wire probe from acquiring the velocity fluctuations at given positions in the flow. This velocity data are arranged by trigger signal at same azimuth of the blade in periodic manner of the rotor blade. From this various wake characteristics are found : radial and axial position of the tip vortex, vortex core characteristics in the flow etc.

  • PDF

Effects of Impeller Shape of Submersible Nonclogging Pump on its Performance (비 막힘형 수중 펌프 임펠러 형상이 펌프 성능에 미치는 영향)

  • Yun, Jeong-Eui
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.12
    • /
    • pp.1201-1207
    • /
    • 2012
  • This study was performed to develop a high-efficiency submersible nonclogging pump impeller. Toward this end, we simulated the effect of some parameters such as the outlet position of a blade ($h_I$), outlet width of a blade ($b_2$), and hub profile on the pump efficiency by using the commercial codes ANSYS CFX and BladeGen. The results showed that the pump efficiency was proportional up to $h_I$= 38 mm and $b_2$= 55 mm. It remained constant over these values. However, the head and shaft power were proportional to $h_I$ and $b_2$ in the simulated ranges. The effects of hub profile changes on the pump efficiency were relatively small compared to those of the other parameters.

Vibration Analysis of a Rotating Blade Considering Pre-twist Angle, Cross Section Taper and a Concentrated Mass (초기 비틀림 각과 단면 테이퍼 그리고 집중질량을 갖는 회전하는 블레이드의 진동해석)

  • Kim, Hyung Yung;Yoo, Hong Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.4
    • /
    • pp.338-346
    • /
    • 2013
  • Equations of motion of a rotating blade considering pre-twist angle, cross section taper and a concentrated mass are derived using the hybrid deformation variable modeling method. For the modeling of a concentrated mass which is located at an arbitrary position of the blade, a Dirac delta function is employed for the mass density function. The final equations for the vibration analysis are transformed into a dimensionless form using several dimensionless parameters. The effects of the dimensionless parameters on the vibration characteristics of the rotating blade are investigated through numerical analysis.

Vibration Analysis of A Rotating Cantilever Blade with Multiple Concentrated Masses with an Elastically Restrained Root (다중 집중질량효과에 의한 탄성 회전 블레이드의 진동해석)

  • Yun Kyung-Jae
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.7 no.4 s.19
    • /
    • pp.114-124
    • /
    • 2004
  • In this paper, we have proposed a novel method which can analysis a rotating elastically restrained blade with concentrated masses located in an arbitrary position. 1:he equations of motion are derived and transformed into a dimensionless form to investigate general phenomena. For the modeling of the multi-concentrated masses, the Dirac delta function is used for the mass density function. Simulation results show that the vibration characteristics of elastic restrained blade of according to dimensionless variables for example, multiple masses magnitude and mass location ratio. This method can be applied to an practical rotating blade system required to more accurate results.

Optimal Placement of Strain Gauge for Vibration Measurement for Fan Blade (블레이드 진동측정을 위한 스트레인 게이지 설치위치 최적화)

  • Choi ByeongKeun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.9 s.90
    • /
    • pp.819-826
    • /
    • 2004
  • A multi-step optimum strategy for the selection of the locations and directions of strain gauges is proposed in this paper to capture at best the modal response of blade in a series of modes on fan blades. It is consist of three steps including two pass reduction step, genetic algorithm and fine optimization to find the locations-directions of strain gauges. The optimization is based upon the maximum signal-to-noise ratio(SNR) of measured strain values with respect to the inherent system measurement noise, the mispositioning of the gauge in location and gauge failure. Optimal gauge positions for a fan blade is analyzed to prove the effectiveness of the multi-step optimum methodology and to investigate the effects of the considering parameters such as the mispositioning level, the probability of gauge failure, and the number of gauges on the optimal strain gauge position.

The Development of Blade Pitch System Using Super Capacitor Storage (슈퍼 커패시터를 장착한 풍력발전용 피치 시스템 개발)

  • Choi, Hee-young;Ryu, Ji-su;Lee, Sang-ho
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.311-312
    • /
    • 2012
  • Blade pitch control system monitors and adjusts angle of the blades and controls rotation speed of blades. This paper shows 2MW pitch system hardware and electric part. Blade pitch system consists of pitch drive, gear box, motor and energy storage. Fieldbus is base on CANopen protocol. Fail-Safe system moves the blades to a safety position in case of any fault condition. The super capacitor energy storage provides emergency back up to the Pitch servo driver during feathering the blades. This paper studied Blade pitch servo driver and a bi-directional DC-DC converter for fail-safe system.

  • PDF

Power Coefficient and Pressure Distributions on Blade Surfaces of a Wind Turbine with Tiltable Blades by 3D Simulations (날개 틸팅형 풍력발전기의 출력과 날개 표면의 압력분포에 대한 3차원 유동 해석)

  • Jeong, Chang-Do;Bae, Hyunwoo;Sung, Jaeyong
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • In this study, a new shape of wind turbine with horizontal axis has been proposed. The proposed wind turbine has two pairs of 3 tiltable blades which minimizes air resistance during the reverse rotational direction. Under a given wind speed, 3D numerical simulations on tiltable blades were performed for various TSRs(tip-speed-ratios). Four cases of rotational position was considered to analyze the torque and wind power generated on the blade surfaces. The results show that the maximum wind power occurs at the TSR of 0.2. Due to the blade tilting, the wind passes through the blade without air resistance at the reverse rotational direction. The torque is mainly caused by pressure differences between the front and rear surface of the blade, and it becomes maximum when the blade is located at the azimuth angle of 330°.

Effect of Blade Loading on the Structure of Tip Leakage Flow in a Forward-Swept Axial-Flow Fan (블레이드 하중이 축류형 팬에서의 팁 누설 유동구조에 미치는 영향)

  • 이공희;명환주;백제현
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.4
    • /
    • pp.294-304
    • /
    • 2003
  • An experimental analysis using three-dimensional laser Doppler velocimetry(LDV) measurement and computational analysis using the Reynolds stress model in FLUENT are conducted to give a clear understanding of the effect of blade loading on the structure of tip leakage flow in a forward-swept axial-flow fan operating at the maximum efficiency condition ($\Phi$=0.25) and two off-design conditions ($\Phi$=0.21 and 0.30). As the blade loading increases, the onset position of the rolling-up of tip leakage flow moves upstream and the trajectory of tip leakage vortex center is more inclined toward the circumferential direction. Because the casing boundary layer becomes thicker and the mixing between the through-flow and the leakage jet with the different flow direction is enforced, the streamwise vorticity decays more fast with the blade loading increasing. A distinct tip leakage vortex is observed downstream of the blade trailing edge at $\Phi$=0.30, but it is not observed at $\Phi$=0.21 and 0.25.

The Effect of Trailing Wake Asymmetry on a Propeller Blade Forces in Inclined Inflow (비대칭 후류를 고려한 경사축 추진기의 유동해석)

  • Sang-Woo Pyo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.35 no.1
    • /
    • pp.24-31
    • /
    • 1998
  • Unsteady propeller blade forces arising from shaft inclination have been found to be an important contribution tn total blade forces. The position of the wake relative to a blade oscillates with the first blade frequency, thus giving rise to unsteady blade forces which is significant relative to the forces produced directly by flow inclination. In order to find a wake geometry due to shaft inclination, a non-axisymmetric wake model is developed and applied to a specific case, which has experimental values. Predicted cavity shapes and unsteady forces acting on the blades of an inclined shaft propeller are compared to those predicted by other numerical methods, as well as those measured in experiments.

  • PDF

Fault Tolerant Control of Wind Turbine with Sensor and Actuator Faults

  • Kim, Jiyeon;Yang, Inseok;Lee, Dongik
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.28-37
    • /
    • 2013
  • This paper presents a fault-tolerant control technique for wind turbine systems with sensor and actuator faults. The control objective is to maximize power production and minimize turbine loads by calculating a desired pitch angle within their limits. Any fault with a sensor and actuator can cause significant error in the pitch position of the corresponding blade. This problem may result in insufficient torque such that the power reference cannot be achieved. In this paper, a fault-tolerant control technique using a robust dynamic inversion observer and control allocation is employed to achieve successful pitch control despite these faults in the sensor and actuator. The observer based detection method is used to detect and isolate sensor faults by checking whether errors are larger than threshold values. In addition, the control allocation technique is adopted to tolerate actuator fault. Control allocation is one of the most commonly used fault-tolerant control techniques, especially for over-actuated systems. Further, the control allocation method can be used to achieve the power reference even in the event of blade actuator fault by redistributing the lost torque due to erroneous pitch position into non-faulty blade actuators. The effectiveness of the proposed method is demonstrated through simulations with a benchmark model of the wind turbine.