• Title/Summary/Keyword: bit-rate

Search Result 3,050, Processing Time 0.024 seconds

Algorithm and experimental verification of underwater acoustic communication based on passive time reversal mirror in multiuser environment (다중송신채널 환경에서 수동형 시역전에 기반한 수중음향통신 알고리즘 및 실험적 검증)

  • Eom, Min-Jeong;Oh, Sehyun;Kim, J.S.;Kim, Sea-Moon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.3
    • /
    • pp.167-174
    • /
    • 2016
  • Underwater communication is difficult to increase the communication capacity because the carrier frequency is lower than that of radio communications on land. This is limited to the bandwidth of the signal under the influence of the characteristics of an ocean medium. As the high transmission speed and large transmission capacity have become necessary in the limited frequency range, the studies on MIMO (Multiple Input Multiple Output) communication have been actively carried out. The performance of the MIMO communication is lower than that of the SIMO (Single Input Multiple Output) communication because cross-talk occurs due to multiusers along with inter symbol interference resulting from the channel characteristics such as delay spread and doppler spread. Although the adaptive equalizer considering multi-channels is used to mitigate the influence of the cross-talk, the algorithm is normally complicated. In this paper, time reversal mirror technique with the characteristic of a self-equalization will be applied to simplify the compensation algorithm and relieve the cross-talk in order to improve the communication performance when the signal transmitted from two channels is received over interference on one channel in the same time. In addition, the performance of the MIMO communication based on the time reversal mirror is verified using data from the SAVEX15(Shallow-water Acoustic Variability Experiment 2015) conducted at the northern area of East China Sea in May 2015.

Quality Verification of Fixed and Mobile Hybrid 3DTV Services via a Subjective Test of Mixed-resolution Stereoscopic Videos (혼합 해상도 양안식 영상에 대한 주관적 화질평가를 통한 고정 및 이동 융합형 3DTV 서비스의 품질 검증)

  • Lee, Jooyoung;Kim, Sung-Hoon;Jeong, Seyoon;Choi, Jin Soo;Kang, Dong-Wook;Jung, Kyeong-Hoon;Kim, Jinwoong
    • Journal of Broadcast Engineering
    • /
    • v.19 no.2
    • /
    • pp.148-157
    • /
    • 2014
  • Various techniques have been developed for efficient compression of stereoscopic 3D videos. Mixed-resolution based approach is one representative bit-rate saving method based on the characteristics of human visual system that the mixed-resolution stereoscopic videos are perceived close to the higher resolution. However, when the difference between the left and right image resolutions is bigger than a certain threshold level, it causes the perceived quality degradation of the 3D images. Subsequently, several researches tried to find the correlation between the difference in resolution and the level of the perceived quality degradation, but they conducted the experiments just considering the difference in resolution without considering the viewing distances, so thereby different results were retrieved from test to test. In this work, we calculated the optimal viewing distance based on the human visual system, and conducted the subjective tests with the calculated viewing distance. With the results, we demonstrate that the fixed and mobile hybrid 3DTV, which is based on mixed-resolution stereoscopic images, can provide the high quality 3D services.

Parallelization Method of Slice-based video CODEC (슬라이스 기반 비디오 코덱 병렬화 기법)

  • Nam, Jung-Hak;Ji, Bong-Il;Jo, Hyun-Ho;Sim, Dong-Gyu;Cho, Dae-Sung
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.6
    • /
    • pp.48-56
    • /
    • 2010
  • Recently, we need to dramatically speed up real-time video encoding and decoding on mobile devices because complexity of video CODEC is significantly increasing along with the demand for multimedia service of high-quality and high-definition videos by users. A variety of research is conducted for parallelism of video processing using newly developed multi-core platforms. In this paper, we propose a method of parallelism based on slice partition of video compression CODEC. We propose a novel concept of a parallel slice for parallelism and propose a new coding order to be adequate to the parallel slice which keeps high coding efficiency. To minimize synchronization time of multiple parallel slices, we also propose a synchronization method to determinate whether the parallel slice could be independently decoded or not. Experimental results shows that we achieved 27.5% (40.7%) speed-up by parallelism with bit-rate increase of 3.4% (2.7%) for CIF sequences (720p sequences) by implementing the proposed algorithm on the H.264/AVC.

Fast Coding Unit Decision Algorithm Based on Region of Interest by Motion Vector in HEVC (움직임 벡터에 의한 관심영역 기반의 HEVC 고속 부호화 유닛 결정 방법)

  • Hwang, In Seo;Sunwoo, Myung Hoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.11
    • /
    • pp.41-47
    • /
    • 2016
  • High efficiency video coding (HEVC) employs a coding tree unit (CTU) to improve the coding efficiency. A CTU consists of coding units (CU), prediction units (PU), and transform units (TU). All possible block partitions should be performed on each depth level to obtain the best combination of CUs, PUs, and TUs. To reduce the complexity of block partitioning process, this paper proposes the PU mode skip algorithm with region of interest (RoI) selection using motion vector. In addition, this paper presents the CU depth level skip algorithm using the co-located block information in the previously encoded frames. First, the RoI selection algorithm distinguishes between dynamic CTUs and static CTUs and then, asymmetric motion partitioning (AMP) blocks are skipped in the static CTUs. Second, the depth level skip algorithm predicts the most probable target depth level from average depth in one CTU. The experimental results show that the proposed fast CU decision algorithm can reduce the total encoding time up to 44.8% compared to the HEVC test model (HM) 14.0 reference software encoder. Moreover, the proposed algorithm shows only 2.5% Bjontegaard delta bit rate (BDBR) loss.

An Efficient data management Scheme for Hierarchical Multi-processing using Double Hash Chain (이중 해쉬체인을 이용한 계층적 다중 처리를 위한 효율적인 데이터 관리 기법)

  • Jeong, Yoon-Su;Kim, Yong-Tae;Park, Gil-Cheol
    • Journal of Digital Convergence
    • /
    • v.13 no.10
    • /
    • pp.271-278
    • /
    • 2015
  • Recently, bit data is difficult to easily collect the desired data because big data is collected via the Internet. Big data is higher than the rate at which the data type and the period of time for which data is collected depending on the size of data increases. In particular, since the data of all different by the intended use and the type of data processing accuracy and computational cost is one of the important items. In this paper, we propose data processing method using a dual-chain in a manner to minimize the computational cost of the data when data is correctly extracted at the same time a multi-layered process through the desired number of the user and different kinds of data on the Internet. The proposed scheme is classified into a hierarchical data in accordance with the intended use and method to extract various kinds of data. At this time, multi-processing and tie the data hash with the double chain to enhance the accuracy of the reading. In addition, the proposed method is to organize the data in the hash chain for easy access to the hierarchically classified data and reduced the cost of processing the data. Experimental results, the proposed method is the accuracy of the data on average 7.8% higher than conventional techniques, processing costs were reduced by 4.9% of the data.

Development of PC-based and portable high speed impedance analyzer for biosensor (바이오센서를 위한 PC 기반의 휴대용 고속 임피던스 분석기 개발)

  • Kim, Gi-Ryon;Kim, Gwang-Nyeon;Heo, Seung-Deok;Lee, Seung-Hoon;Choi, Byeong-Cheol;Kim, Cheol-Han;Jeon, Gye-Rok;Jung, Dong-Keun
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.33-41
    • /
    • 2005
  • For more convenient electrode-electrolyte interface impedance analysis in biosensor, a stand-alone impedance measurement system is required. In our study, we developed a PC-based portable system to analyze impedance of the electrochemical cell using microprocessor. The devised system consists of signal generator, programmable amplifiers, A/D converter, low pass filter, potentiostat, I/V converter, microprocessor, and PC interface. As a microprocessor, PIC16F877 which has the processing speed of 5 MIPS was used. For data acquisition, the sampling rate at 40 k samples/sec, resolution of 12 bit is used. RS-232 with 115.2 kbps speed is used for the PC communication. The square wave was used as stimuli signal for impedance analysis and voltage-controlled current measurement method of three-electrode-method were adopted. Acquired voltage and current data are calculated to multifrequency impedance signal after Fourier transform. To evaluate the implemented system, we set up the dummy cell as equivalent circuit of which was composed of resistor, parallel circuit of capacitor and resistor connected in parallel and measured the impedance of the dummy cell; the result showed that there exist accuracy within 5 % errors and reproduction within 1 % errors compared to output of Hioki LCR tester and HP impedance analyzer as a standard product. These results imply that it is possible to analyze electrode-electrolyte interface impedance quantitatively in biosensor and to implement the more portable high speed impedance analysis system compared to existing systems.

Thermally Stimulated Current Analysis of (Ba, Sr)TiO$_3$ Capacitor ((Ba, Sr)TiO$_3$ 커패시터의 Thermally Stimulated Current분석)

  • Kim, Yong-Ju;Cha, Seon-Yong;Lee, Hui-Cheol;Lee, Gi-Seon;Seo, Gwang-Seok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.5
    • /
    • pp.329-337
    • /
    • 2001
  • It has been known that the leakage current in the low field region consists of the dielectric relaxation current and intrinsic leakage current, which cause the charge loss in dynamic random access memory (DRAM) storage capacitor using (Ba,Sr)TiO$_{3}$ (BST) thin film. Especially, the dielectric relaxation current should be seriously considered since its magnitude is much larger than that of the intrinsic leakage current in giga-bit DRAM operation voltage (~IY). In this study, thermally stimulated current (TSC) measurement was at first applied to investigate the activation energy of traps and relative evaluation of the density of traps according to process change. And, through comparing TSC to early methods of I-V or I-t measurement and analyzing, we identify the origin of the dielectric relaxation current and investigate the reliability of TSC measurement. First, the polarization condition such as electric field, time, temperature and heating rate was investigated for reliable TSC measurement. From the TSC measurement, the energy level of traps in the BST thin film has been investigated and evaluated to be 0.20($\pm$0.01) eV and 0.45($\pm$0.02) eV. Based on the TSC measurement results before and after rapid thermal annealing (RTA) process, oxygen vacancy is concluded to be the origin of the traps. TSC characteristics with thermal annealing in the MIM BST capacitor have shown the same trends with the current-voltage (I-V) and current-time (I-t) characteristics. This means that the TSC measurement is one of the effective methods to characterize the traps in the BST thin film.

  • PDF

Fast Matching Pursuit based on Vector Length Comparison (벡터길이 비교를 이용한 고속 Matching Pursuit)

  • O, Seok-Byeong;Jeon, Byeong-U
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.2
    • /
    • pp.129-137
    • /
    • 2001
  • Matching pursuit algorithm was successfully demonstrated useful in low bit-rate video coding, However, one of the practical concerns related to applying the matching pursuit algorithm to application is its massive computation required for finding bases whose weighted sum best approximates the given input image. The main contribution of this paper is that we provide a new method that can drastically reduce the computational load without any degradation of image quality. Its main idea is based on reducing the number of inner product calculation required for finding best bases because the complexity of matching pursuit algorithm is due to the exhaustive local inner product calculation. As the first step, we compute a matrix which is the 1-D inner product of the given motion-compensated error input image with the 1-D vertical Gabor functions using the separable property of Gabor bases. In the second step, we calculate length of each vector in the matrix that corresponds to 1-D horizontal Gabor function, and compare the length with the current maximum absolute inner product value so far. According to the result of this comparison, one can decide whether or not to calculate the inner product. Since most of them do not need to calculate the inner product value, one can significantly reduce the computational load. Experimental results show that proposed method reduces about 70% of inner product calculation compared to the Neff's fast algorithm without any degradation of image quality.

  • PDF

Adaptive Multi-Tap Equalization for Removing ICI Caused by Transmitter Power Transient in LTE Uplink System (LTE 상향 링크 시스템에서 송신기의 전력 과도 현상에 의해 발생하는 ICI를 제거하기 위한 적응적 멀티 탭 등화 기법)

  • Chae, Hyuk-Jin;Cho, Il-Nam;Kim, Dong-Ku
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.8
    • /
    • pp.701-713
    • /
    • 2009
  • This paper studies a method for reducing performance degradation due to losing sub-carrier orthogonality caused by power transient between physical channels in LTE uplink transmission. The pattern of inter-carrier interference(ICI) caused by power transient is different from what has been studied for doppler shift, in that its pattern occurs at front and rear sides of channels in each period of power transient. The reason of ICI's occurrence results from power difference between channels, power transient duration, multi-path channel delay spread, and numbers of sub-carrier. New criterion is proposed to find out number of taps of multi-tap equalizer enough to improve the ICI. The scheme is to determine the number of taps of multi-tap equalizer when a normalized interference or a normalized ICI is greater than a normalized noise. Simulation results show that the number of taps is flexibly adjusted according to SNR(Signal to Noise Ratio) of a received signal to improve Bit Error Rate(BER), while the complexity of the proposed scheme is reduced down to 88 percentage of the classical method.

Ultrasensitive serum thyroglobulin the usefulness of evaluation (Ultrasensitive serum thyroglobulin의 유용성 평가)

  • Lee, Sun Ho;Cho, Eun Bit;Shin, Young Kyun;Lee, Young Ji;Yoo, Seun Hee;Kim, Nyun Ok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.102-107
    • /
    • 2015
  • Purpose Serum Thyroglobulin measurement is a major tool for the follow-up of differentiated thyroid cancer (DTC) patients. Thyroglobulin is Normal thyroid tissue, or thyroid cancer tissue produced only. Thyroid hormone to a halt without Tg differentiation of thyroid cancer recurrence just by measuring how to decide whether there was increasing expectations if I can do it instead. Therefore, in excellent sensitivity Tg new inspection of the functional sensitivity by measuring the looked to evaluate the usefulness of reagents. Thyroidectomy is measuring the numbers Tg (total thyroidectomy) remaining thyroid ablation and radioactive iodine (radioactive iodine remnant ablation, RRA) DTC in patients being diagnosed with or help predict the remaining early detection of thyroid cancer recurrence. Materials and Methods Agent that I'm currently using Tg of the measurements of low clinical specimen for a second drainage of the three (0.08 0.17, 0.98, ng/mL) within the scope of the dilute magnification (2, 4, 8, 16, 32 times) by dilute Intraassy (n=10) and Interassay (n=10) out in no time. Concentration value according to the coefficient of variation and the mean and standard deviation of each measurement (Coefficient of variation, CV) the absolute value of the measured values that corresponds to 20 percent target a coefficient of variation of CV Find the value of the concentration of the functional sensitivity measurement did. Also, analytical sensitivity with recovery rates, Dilution test inspections, and interrelationship, compared. Results Sensitivity is an excellent analytical sensitivity within the prosecutor kit Tg 0.006 ng/mL, and core analytical sensitivity, conducted by the 0.006 ng/mL to same conclusion. Be rather high to 142 percent recovery rate was 60 to measurement and functional sensitivity, 0.01766 ng/mL(Intraassay n=10) was measured at. CBC is relatively good correlation as ($R^2=0.949$) the correlation. Conclusion Recently ultrasensitive thyroglobulin this clinically important indicators of the previous kit and demands are lower than sensitivity to the measurement results. Therefore, ultrasensitive thyroglobulin test is correlated that there would be useful in value in nuclear medicine the thyroid gland.

  • PDF