• Title/Summary/Keyword: bionics

Search Result 128, Processing Time 0.03 seconds

Percutaneous Thrombin Injection Based on Computational Fluid Dynamics of Femoral Artery Pseudoaneurysms

  • Hyoung-Ho Kim;Kyung-Wuk Kim;Changje Lee;Young Ho Choi;Min Uk Kim;Yasutaka Baba
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1834-1840
    • /
    • 2021
  • Objective: To analyze the computational fluid dynamics (CFD) of femoral artery pseudoaneurysm (FAP), identify a suitable location and timing for percutaneous thrombin injection (PTI) based on this analysis, and report our clinical experience with the procedure. Materials and Methods: CFD can be used to analyze the hemodynamics of the human body. An analysis using CFD recommended that the suitable location of the needle tip for PTI is at the center of the aneurysm sac and the optimal timing for starting PTI is during the early inflow phase of blood into the sac. Since 2011, seven patients (three male and four female; median age, 60 years [range, 43-75 years]) with FAP were treated with PTI based on the devised suitable location and time. Prior to the procedure, color Doppler ultrasonography was performed to determine the location and timing of the thrombin injection. Results: The technical success rate of the PTI was 100%. The amount of thrombin used for the procedure ranged from 200 IU to 1000 IU (median, 500 IU). None of the patients experienced any symptoms or signs of embolic complications during the procedure. Follow-up CT images did not reveal any embolism in the lower extremities and showed complete thrombosis of the pseudoaneurysm. Conclusion: Based on our study of CFD, PTI administered centrally in the FAP during early inflow, as seen on color Doppler, can be an effective technique.

Web-based Measurement of ECU Signals on Vehicle using Embedded Linux

  • Choi, Kwang-Hun;Lee, Lee;Lee, Young-Choon;Kwon, Tae-Kyu;Lee, Seong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.138-142
    • /
    • 2004
  • In this paper, we present a new method for monitoring of ECU's sensor signals of vehicle. In order to measure the ECU's sensor signals, the interfaced circuit is designed to communicate ECU and the Embedded Linux is used to monitor communication result through Web the Embedded Linux system and this system is said "ECU Interface Part". In ECU Interface Part the interface circuit is designed to match voltage level between ECU and SA-1110 micro controller and interface circuit to communicate ECU according to the ISO, SAE communication protocol standard. Because Embedded Linux does not allow to access hardware directly in application level, anyone who wants to modify any low level hardware must develop device driver. To monitor ECU's sensor signals the most important thing is to match serial level between ECU and ECU Interface Part. It means to communicate correctly between two hardware we need to match voltage and signal level, and need to match baudrate. The voltage of SA-1110 is 0 ${\sim}$ +3.3V and ECU is 0 ${\sim}$ +12V and, ECU's communication Line K does multiple operation so, the interface circuit is used to match voltage and signal level. In Addition to ECU's baudrate is 10400bps, it's not standard baudrate in computer environment. So, we need to develop a device driver to control the interface circuit, and change baudrate. To monitor ECU's sensor signals through web there's a network socket program is working in Embedded Linux. It works as server program and manages user's connections and commands. Anyone who wants to monitor ECU's sensor signals he just only connect to Embedded Linux system with web browser then, Embedded Linux webserver will return the ActiveX webbased measurement software. It works in web browser and inits ECU, as a result it returns sensor signals through web. All the programs are developed with GCC(GNU C Compiler) and, webbased measurement software is developed with Borland C++ Builder.

  • PDF

Comparison of Essential Oil Composition of Artemisia iwayomogi and Artemisia capillaris (더위지기와 사철쑥의 정유성분 조성 비교)

  • Hong, Chul-Un
    • Applied Biological Chemistry
    • /
    • v.47 no.1
    • /
    • pp.124-129
    • /
    • 2004
  • The composition of essential oils isolated from the aerial parts of Artemisia iwayomogi Kitamura and Artemisia capillaris Thunberg collected from two diffenent cultivation area, respectively, was analyzed by GC and GC-MS. Sixty components were identified in oils from A. iwayomogi. The major components of A. iwayomogi oil collected from one area (Sample A) were iso-pinocamphone (31.64%), 1,8-cineo1e (21.55%), ${\beta}-pinene$ (4.46%), pinocarvone (3.72%), myrtenal (3.42%) and trans-pinocarve1 (3.14%), and the major components of the oil from the other area (Sample B) were camphor (26.99%), 1,8-cineo1e (21.55%), ${\alpha}-terpineol$ (7.63%), borneol (4.10%), camphene (3.97%) and artemisia ketone (3.84%). Eighty components were identified in oils from A. capillaris. The major components were capillene $(26.01{\sim}30.31%)$, ${\beta}-pinene(8.55{\sim}18.38%)$, ${\beta}-caryophyllene(8.80{\sim}13.70%)$, ${\beta}-himachalene(1.67{\sim}5.57%)$, $cis,trans- {\alpha}-farnesene(2.10{\sim}7.38%)$ and germacrene D $(2.27{\sim}5.46%)$ and there was no difference in oil composition of A. capillaris between two cultivation area.

Enhanced Efficacy of Human Brain-Derived Neural Stem Cells by Transplantation of Cell Aggregates in a Rat Model of Parkinson's Disease

  • Shin, Eun Sil;Hwang, Onyou;Hwang, Yu-Shik;Suh, Jun-Kyo Francis;Chun, Young Il;Jeon, Sang Ryong
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.5
    • /
    • pp.383-389
    • /
    • 2014
  • Objective : Neural tissue transplantation has been a promising strategy for the treatment of Parkinson's disease (PD). However, transplantation has the disadvantages of low-cell survival and/or development of dyskinesia. Transplantation of cell aggregates has the potential to overcome these problems, because the cells can extend their axons into the host brain and establish synaptic connections with host neurons. In this present study, aggregates of human brain-derived neural stem cells (HB-NSC) were transplanted into a PD animal model and compared to previous report on transplantation of single-cell suspensions. Methods : Rats received an injection of 6-OHDA into the right medial forebrain bundle to generate the PD model and followed by injections of PBS only, or HB-NSC aggregates in PBS into the ipsilateral striatum. Behavioral tests, multitracer (2-deoxy-2-[$^{18}F$]-fluoro-D-glucose ([$^{18}F$]-FDG) and [$^{18}F$]-N-(3-fluoropropyl)-2-carbomethoxy-3-(4-iodophenyl)nortropane ([$^{18}F$]-FP-CIT) microPET scans, as well as immunohistochemical (IHC) and immunofluorescent (IF) staining were conducted to evaluate the results. Results : The stepping test showed significant improvement of contralateral forelimb control in the HB-NSC group from 6-10 weeks compared to the control group (p<0.05). [$^{18}F$]-FP-CIT microPET at 10 weeks posttransplantation demonstrated a significant increase in uptake in the HB-NSC group compared to pretransplantation (p<0.05). In IHC and IF staining, tyrosine hydroxylase and human ${\beta}2$ microglobulin (a human cell marker) positive cells were visualized at the transplant site. Conclusion : These results suggest that the HB-NSC aggregates can survive in the striatum and exert therapeutic effects in a PD model by secreting dopamine.

Connectivity Analysis Between EEG and EMG Signals by the Status of Movement Intention (운동 의도에 따른 뇌파-근전도 신호 간 연결성 분석)

  • Kim, Byeong-Nam;Kim, Yun-Hee;Kim, Laehyun;Kwon, Gyu-Hyun;Jang, Won-Seuk;Yoo, Sun-Kook
    • Science of Emotion and Sensibility
    • /
    • v.19 no.1
    • /
    • pp.31-38
    • /
    • 2016
  • The brain and muscles both of which are composed of top-down structure occur the connectivity with the change of Electroencephalogram(EEG) and Electromyogram(EMG). In this paper, we studied the difference of functional connectivity between brain and muscles that by applying coherence method to EEG and EMG signals when users exercised upper limb with and without the movement intention. The changes in the EEG and EMG signals were inspected using coherence method. During the upper limb exercise, the mu (8~14 Hz) and beta (15~30 Hz) rhythms of the EEG signal at the motor cortex area are activated. And then the beta and piper (30~60 Hz) rhythms of the EMG signal are activated as well. The result of coherence analysis between EEG and EMG showed the coefficient of active exercise including movement intention is significantly higher than passive exercise. The coherence relations between cognitive response and muscle movement could interpret that the connectivity between the brain and muscle appear during active exercise with movement intention. The feature of coherence between brain and muscles by the status of movement intention will be useful in designing the rehabilitation system requiring feedback depending on the users' movement intention status.

Rapid Determining for Subtypes and Pandemic Type of Swine Influenza Virus by Diagnostic One-step RT-PCR (진단용 one-step RT-PCR을 통한 돼지 인플루엔자 바이러스의 아형 및 pandemic 유형에 대 한 신속한 결정)

  • Kim, Gwang Il;Kim, Jee In;Kwon, Jin-Hyeap;Min, Yoo Hong;Kang, Joo Il;Lee, Chang-Ho;Kim, Sung-Hee;Lim, Jae-Hwan
    • Journal of Life Science
    • /
    • v.28 no.5
    • /
    • pp.555-562
    • /
    • 2018
  • Swine influenza virus (SIV) causes one of the most common diseases of the pig population, and its subtypes are determined by hemagglutinin (HA) and neuraminidase (NA). Recently, the SIV subtype diagnosis has been developed. The method using antigen-antibody reaction rather than PCR was mainly used because of the large change in the ribonucleotide sequences of SIV. Here, we have developed 10 diagnostic primer sets through multi-nucleotide sequences alignment of spreaded SIV since 2008 in Korea and then optimized the reaction of the one-step RT-PCR for rapid determination of SIV subtype. In addition, specific primers were designed to early determine the pandemic SIV by detecting unique M sequences proven in highly infectious and virulent subtypes of the influenza H1N1 (pH1N1). Here, some of the SIVs spread in Korea from 2008 to 2014 have been tested to determine the subtypes and pandemic potential of SIV. All diagnostic primer sets were found to be able to accurately determine the SIV subtype and to detect the pandemic SIV. In conclusion, it was confirmed that the optimized one-step RT-PCR analysis using these primer sets is useful for rapid diagnosis of SIV subtypes. These results can be used for development of SIV subtype diagnostic kit to early detect before virulent SIV spreads do.

A portable electronic nose (E-Nose) system using PDA device (개인 휴대 단말기 (PDA)를 기반으로 한 휴대용 E-Nose의 개발)

  • Yang, Yoon-Seok;Kim, Yong-Shin;Ha, Seung-Chul;Kim, Yong-Jun;Cho, Seong-Mok;Pyo, Hyeon-Bong;Choi, Chang-Auck
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.69-77
    • /
    • 2005
  • The electronic nose (e-nose) has been used in food industry and quality controls in plastic packaging. Recently it finds its applications in medical diagnosis, specifically on detection of diabetes, pulmonary or gastrointestinal problem, or infections by examining odors in the breath or tissues with its odor characterizing ability. Moreover, the use of portable e-nose enables the on-site measurements and analysis of vapors without extra gas-sampling units. This is expected to widen the application of the e-nose in various fields including point-of-care-test or e-health. In this study, a PDA-based portable e-nose was developed using micro-machined gas sensor array and miniaturized electronic interfaces. The rich capacities of the PDA in its computing power and various interfaces are expected to provide the rapid and application specific development of the diagnostic devices, and easy connection to other facilities through information technology (IT) infra. For performance verification of the developed portable e-nose system, Six different vapors were measured using the system. Seven different carbon-black polymer composites were used for the sensor array. The results showed the reproducibility of the measured data and the distinguishable patterns between the vapor species. Additionally, the application of two typical pattern recognition algorithms verified the possibility of the automatic vapor recognition from the portable measurements. These validated the portable e-nose based on PDA developed in this study.

Pupil Data Measurement and Social Emotion Inference Technology by using Smart Glasses (스마트 글래스를 활용한 동공 데이터 수집과 사회 감성 추정 기술)

  • Lee, Dong Won;Mun, Sungchul;Park, Sangin;Kim, Hwan-jin;Whang, Mincheol
    • Journal of Broadcast Engineering
    • /
    • v.25 no.6
    • /
    • pp.973-979
    • /
    • 2020
  • This study aims to objectively and quantitatively determine the social emotion of empathy by collecting pupillary response. 52 subjects (26 men and 26 women) voluntarily participated in the experiment. After the measurement of the reference of 30 seconds, the experiment was divided into the task of imitation and spontaneously self-expression. The two subjects were interacted through facial expressions, and the pupil images were recorded. The pupil data was processed through binarization and circular edge detection algorithm, and outlier detection and removal technique was used to reject eye-blinking. The pupil size according to the empathy was confirmed for statistical significance with test of normality and independent sample t-test. Statistical analysis results, the pupil size was significantly different between empathy (M ± SD = 0.050 ± 1.817)) and non-empathy (M ± SD = 1.659 ± 1.514) condition (t(92) = -4.629, p = 0.000). The rule of empathy according to the pupil size was defined through discriminant analysis, and the rule was verified (Estimation accuracy: 75%) new 12 subjects (6 men and 6 women, mean age ± SD = 22.84 ± 1.57 years). The method proposed in this study is non-contact camera technology and is expected to be utilized in various virtual reality with smart glasses.