• 제목/요약/키워드: biomedical

검색결과 13,264건 처리시간 0.042초

14C-아세트아미노펜 비임상시험을 통한 생체시료 분석용 가속질량분석기의 검증 (Non-clinical Trials using 14C-Acetaminophen to Validate Biomedical Accelerator Mass Spectrometry System)

  • 송진호;심재훈;박정배;여창수;배수현;최민선;권미혜;김경민
    • 방사선산업학회지
    • /
    • 제17권2호
    • /
    • pp.127-134
    • /
    • 2023
  • Pharmacokinetic (PK) data provide pivotal information in drug development, and they are usually first studied in the preclinical stage using various animals. However, quite often, animal PK data may not match with human PK, especially in metabolites. Thus, most regulatory agencies in the world make it mandatory to obtain metabolite information using 14C radiolabeled drug in human for small molecule drug candidates. However, such studies are expensive and time consuming and they are usually done at the end of Phase II trials using ~3.7 MBq of 14C labeled drug in a limited number of human subjects. Introduction of accelerator mass spectrometry (AMS) in this kind of study has revolutionized it. Since AMS can measure 14C level as close as natural abundance, it can quantify the amounts of 14C labeled drugs and their metabolites produced in human body that consumes less than the amount of 0.0037 MBq of 14C labeled drug, a very safe level of radioactive dose in human. Therefore, it is now possible to conduct human 14C studies safely in early clinical trials without spending hefty amount of money and time. Korea Radioisotope Center for Pharmaceuticals(KRICP) at Korea Institute of Biological and Medical Sciences(KIRAMS) has established an AMS facility in 2018, housing a 0.5MV AMS manufactured at the US National Electrostatics Corps (NEC). The AMS instrument has been validated using various standard samples that have been prepared at Lawrence Livermore National Laboratory in the US, a worldly reputable provider of AMS standards. In this paper, we present a mass balance study for acetaminophen in rats using AMS and prove that the study results are equivalent with those of literature, which shows the AMS facilities at KRICP has successfully installed and be ready to be used in the various PK studies using 14C labelled compounds for new drug development.

Prevalence of Inflammatory Bowel Disease Unclassified, as Estimated Using the Revised Porto Criteria, among Korean Pediatric Patients with Inflammatory Bowel Disease

  • Sung Hee Lee;Minsoo Shin;Seo Hee Kim;Seong Pyo Kim;Hyung-Jin Yoon;Yangsoon Park;Jaemoon Koh;Seak Hee Oh;Jae Sung Ko;Jin Soo Moon;Kyung Mo Kim
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제27권4호
    • /
    • pp.206-214
    • /
    • 2024
  • Purpose: Few studies have reported the prevalence of inflammatory bowel disease unclassified (IBDU) among Korean pediatric IBD (PIBD) population. To address this gap, we used two tertiary centers and nationwide population-based healthcare administrative data to estimate the prevalence of Korean pediatric IBDU at the time of diagnosis. Methods: We identified 136 patients aged 2-17 years with newly diagnosed IBD (94 Crohn's disease [CD] and 42 ulcerative colitis [UC]) from two tertiary centers in Korea between 2005 and 2017. We reclassified these 136 patients using the revised Porto criteria. To estimate the population-based prevalence, we analyzed Korean administrative healthcare data between 2005 and 2016, which revealed 3,650 IBD patients, including 2,538 CD and 1,112 UC. By extrapolating the reclassified results to a population-based dataset, we estimated the prevalence of PIBD subtypes. Results: Among the 94 CD, the original diagnosis remained unchanged in 93 (98.9%), while the diagnosis of one (1.1%) patient was changed to IBDU. Among the 42 UC, the original diagnosis remained unchanged in 13 (31.0%), while the diagnoses in 11 (26.2%), 17 (40.5%), and one (2.4%) patient changed to atypical UC, IBDU, and CD, respectively. The estimated prevalences of CD, UC, atypical UC, and IBDU in the Korean population were 69.5%, 9.4%, 8.0%, and 13.1%, respectively. Conclusion: This study is the first in Korea to estimate the prevalence of pediatric IBDU. This prevalence (13.1%) aligns with findings from Western studies. Large-scale prospective multicenter studies on PIBDU are required to examine the clinical features and outcomes of this condition.

Functional Aspects of the Obesity Paradox in Patients with Severe Coronavirus Disease-2019: A Retrospective, Multicenter Study

  • Jeongsu Kim;Jin Ho Jang;Kipoong Kim;Sunghoon Park;Su Hwan Lee;Onyu Park;Tae Hwa Kim;Hye Ju Yeo;Woo Hyun Cho
    • Tuberculosis and Respiratory Diseases
    • /
    • 제87권2호
    • /
    • pp.176-184
    • /
    • 2024
  • Background: Results of studies investigating the association between body mass index (BMI) and mortality in patients with coronavirus disease-2019 (COVID-19) have been conflicting. Methods: This multicenter, retrospective observational study, conducted between January 2020 and August 2021, evaluated the impact of obesity on outcomes in patients with severe COVID-19 in a Korean national cohort. A total of 1,114 patients were enrolled from 22 tertiary referral hospitals or university-affiliated hospitals, of whom 1,099 were included in the analysis, excluding 15 with unavailable height and weight information. The effect(s) of BMI on patients with severe COVID-19 were analyzed. Results: According to the World Health Organization BMI classification, 59 patients were underweight, 541 were normal, 389 were overweight, and 110 were obese. The overall 28-day mortality rate was 15.3%, and there was no significant difference according to BMI. Univariate Cox analysis revealed that BMI was associated with 28-day mortality (hazard ratio, 0.96; p=0.045), but not in the multivariate analysis. Additionally, patients were divided into two groups based on BMI ≥25 kg/m2 and underwent propensity score matching analysis, in which the two groups exhibited no significant difference in mortality at 28 days. The median (interquartile range) clinical frailty scale score at discharge was higher in nonobese patients (3 [3 to 5] vs. 4 [3 to 6], p<0.001). The proportion of frail patients at discharge was significantly higher in the nonobese group (28.1% vs. 46.8%, p<0.001). Conclusion: The obesity paradox was not evident in this cohort of patients with severe COVID-19. However, functional outcomes at discharge were better in the obese group.

Usefulness of Impulse Oscillometry in Predicting the Severity of Bronchiectasis

  • Ji Soo Choi;Se Hyun Kwak;Min Chul Kim;Chang Hwan Seol;Seok-Jae Heo;Sung Ryeol Kim;Eun Hye Lee
    • Tuberculosis and Respiratory Diseases
    • /
    • 제87권3호
    • /
    • pp.368-377
    • /
    • 2024
  • Background: Bronchiectasis is a chronic respiratory disease that leads to airway inflammation, destruction, and airflow limitation, which reflects its severity. Impulse oscillometry (IOS) is a non-invasive method that uses sound waves to estimate lung function and airway resistance. The aim of this study was to assess the usefulness of IOS in predicting the severity of bronchiectasis. Methods: We retrospectively reviewed the IOS parameters and clinical characteristics in 145 patients diagnosed with bronchiectasis between March 2020 and May 2021. Disease severity was evaluated using the FACED score, and patients were divided into mild and moderate/severe groups. Results: Forty-four patients (30.3%) were in the moderate/severe group, and 101 (69.7%) were in the mild group. Patients with moderate/severe bronchiectasis had a higher airway resistance at 5 Hz (R5), a higher difference between the resistance at 5 and 20 Hz (R5-R20), a higher resonant frequency (Fres), and a higher area of reactance (AX) than patients with mild bronchiectasis. R5 ≥0.43, resistance at 20 Hz (R20) ≥0.234, R5-R20 ≥28.3, AX ≥1.02, reactance at 5 Hz (X5) ≤-0.238, and Fres ≥20.88 revealed significant univariable relationships with bronchiectasis severity (p<0.05). Among these, only X5 ≤-0.238 exhibited a significant multivariable relationship with bronchiectasis severity (p=0.039). The receiver operating characteristic curve for predicting moderate-to-severe bronchiectasis of FACED score based on IOS parameters exhibited an area under the curve of 0.809. Conclusion: The IOS assessed by the disease severity of FACED score can effectively reflect airway resistance and elasticity in bronchiectasis patients and serve as valuable tools for predicting bronchiectasis severity.

Beneficial effects of oral antioxidant supplementation on semen quality parameters, reproductive hormones, and sperm DNA integrity in men with idiopathic oligoasthenoteratozoospermia

  • Chaymae Rochdi;Meriem Ouadrhiri;Larbi Allai;Ibtissam Bellajdel;Samira Mamri;Hafsa Taheri;Hanane Saadi;Ahmed Mimouni;Mohammed Choukri
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제51권2호
    • /
    • pp.135-141
    • /
    • 2024
  • Objective: Recently, oral antioxidants in combined forms have been used to treat men with idiopathic infertility. This study aimed to evaluate the effects of treatment with vitamin C, vitamin E, selenium, zinc, arginine, L-carnitine, and coenzyme Q10 on sperm quality parameters, DNA integrity, reproductive hormones, and pregnancy rates in men with infertility and idiopathic oligoasthenoteratozoospermia (OAT). Methods: A prospective study was conducted on 420 men with infertility and idiopathic OAT who took an oral supplement of antioxidant SP-Power tablets twice daily for 6 months. Semen quality, reproductive hormones, and the DNA fragmentation index (DFI) were evaluated at baseline and at 3 and 6 months after supplementation, using the World Health Organization 2021 guidelines. Results: No significant difference was observed in volume or the percentage of typical morphology during treatment. A significant improvement in sperm concentration was observed after supplementation (8.67±1.41, 12.17±1.91, and 19.01±0.86 at baseline, 3, and 6 months respectively, p<0.01). The total motility, progressive motility, and total motile sperm count also increased significantly (p<0.01), whereas the DFI decreased after 6 months. There was an increase in normal FSH levels and testosterone levels after 6 months of supplementation of antioxidant SP-Power but these differences were not statistically significant (p=not significant and p=0.06, respectively). Conclusion: Supplementation with SP-Power tablets improved sperm quality parameters, sperm DFI, some reproductive hormones, and pregnancy rates in men with infertility and idiopathic OAT, which could be attributed to the supplement's synergistic antioxidant action. Further studies are needed to determine the effects of supplementation on oxidative stress markers.

성인여성에게 필라테스 호흡을 동반한 운동이 몸통의 근활성도 및 균형에 미치는 영향 (The Effects of Pilates Breathing on Trunk Muscle Activity and Balance in Adult Females)

  • 이문정;이수경;김병조;안수홍
    • PNF and Movement
    • /
    • 제22권2호
    • /
    • pp.275-288
    • /
    • 2024
  • Purpose: The purpose of this study was to assess the effects of breathing techniques on trunk muscle activity and balance during Pilates reformer footwork exercises, comparing results both within and between groups before and after the intervention. Methods: Thirty-one adult women over the age of 20 were selected as subjects for this study. They were divided into a Pilates breathing group (n = 15) and a general breathing group (n = 16) using a randomized control group study design. A surface electromyogram was used to measure muscle activity within and between the groups before and after the reformer footwork exercise. Static balance measurements were taken while standing on two legs, and dynamic balance measurements were taken while standing on one leg. All measurements were taken three times, and the average values were used for analysis. Results: The results of the study showed that muscle activity increased with significant differences in the external oblique and transverse abdominal muscles after exercise in the pre-post comparison within the Pilates breathing group (p < 0.05). In the between-group comparison, there was a significant difference in the increase in muscle activity of the external oblique and transverse abdominal muscles in the Pilates breathing group (p < 0.05). In the pre-post comparison of static and dynamic balance within the Pilates breathing group, there was a significant increase (p < 0.05) after exercise. The Pilates breathing group also showed a significant increase even in the between-group comparison (p < 0.05). Conclusion: This study confirmed that reformer footwork exercise accompanied by Pilates breathing has positive effects on muscle activity and static balance ability of trunk muscles in adult women. Therefore, reformer footwork exercise accompanied by Pilates breathing can be presented as an effective exercise method to increase trunk stability and balance ability through the simultaneous activity of the trunk muscles.

The Effects of Radiofrequency Catheter Ablation for Atrial Fibrillation on Right Ventricular Function

  • Minkwan Kim;Jae-Sun Uhm;Je-Wook Park;SungA Bae;In Hyun Jung;Seok-Jae Heo;Daehoon Kim;Hee Tae Yu;Tae-Hoon Kim;Boyoung Joung;Moon-Hyoung Lee
    • Korean Circulation Journal
    • /
    • 제54권4호
    • /
    • pp.203-217
    • /
    • 2024
  • Background and Objective: The effects of radiofrequency catheter ablation (RFCA) for atrial fibrillation (AF) on right ventricular (RV) function are not well known. Methods: Patients who underwent RFCA for AF and underwent pre- and post-procedural echocardiography were enrolled consecutively. Fractional area change (FAC), RV free-wall longitudinal strain (RVFWSL), and RV 4-chamber strain including the ventricular septum (RV4CSL) were measured. Changes in FAC, RVFWSL, and RV4CSL before and after RFCA were compared among paroxysmal AF (PAF), persistent AF (PeAF), and long-standing persistent AF (LSPeAF) groups. Results: A total of 164 participants (74 PAF, 47 PeAF, and 43 LSPeAF; age, 60.8 ± 9.8 years; men, 74.4%) was enrolled. The patients with PeAF and LSPeAF had worse RV4CSL (p<0.001) and RVFWSL (p<0.001) than those with PAF and reference values. Improvements in RVFWSL and RV4CSL after RFCA were significant in the PeAF group compared with the PAF and LSPeAF groups (ΔRV4CSL, 8.4% [5.1, 11.6] in PeAF vs. 1.0% [-1.0, 4.1] in PAF, 1.9% [-0.2, 4.4] in LSPeAF, p<0.001; ΔRVFWSL, 9.0% [6.9, 11.5] in PeAF vs. 0.9% [-1.4, 4.9] in PAF, 1.0% [-1.0, 3.6] in LSPeAF, p<0.001). In patients without recurrence, improvements in RVFWSL and RV4CSL after RFCA were significant in the PeAF group compared to the LSPeAF group. Conclusions: RV systolic function is more impaired in patients with PeAF and LSPeAF than in those with PAF. RV systolic function is more improved after RFCA in patients with PeAF than in those with PAF or LSPeAF.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

경추부 자기공명영상의 움직임 인공물 개선을 위한 구강내 삽입 유도 기구의 적용 (Application of the Orally Inserted Guiding Device for the Improved Motion Artifacts of the Cervical Spine MRI)

  • 이재흔;유윤식;이재승;임인철
    • 한국방사선학회논문지
    • /
    • 제8권6호
    • /
    • pp.317-323
    • /
    • 2014
  • 본 연구는 임상적으로 정형화된 경추부 MR 검사에서 틀니 제거 환자들의 불수의적 구강운동, 침 삼킴 등의 불수의적 구강 운동에 의한 움직임 인공물을 개선하기 위해 구강내 삽입 유도 기구를 이용한 검사방법을 제안하고 인공물을 최소화하여 질환의 경계가 불분명했던 부분을 명확하게 하여 최적의 영상을 만들고자 하였다. 2014년 1월 1일부터 2014년 6월 31일까지 경추부 질환으로 내원한 환자 중 틀니를 착용한 30명을 대상으로 경추 자기공명검사를 시행하였다. 방법으로는 틀니를 제거한 후 바로 누운(supine position)자세로 $T_1$-TSE-Sagittal, $T_2$-TSE-Sagittal, $T_1$-TSE-Axial, $T_2$-TSE-Axial을 획득하고 환자의 입에 구강내 삽입 유도 기구를 삽입한 후 $T_1$-and $T_2$-TSE-Axial을 검사하였다. 결과로는 정량적 분석 SNR은 구강 삽입 유도 기구 사용 전 $T_1$-TSE-Axial이 $22.33{\pm}8.59$, 사용 후 $25.21{\pm}7.93$, $T_2$-TSE-Axial은 사용 전 $14.49{\pm}5.74$, 사용 후 $16.61{\pm}6.72$이었다. CNR은 $T_1$-TSE-Axial이 $0.23{\pm}0.01$, $T_2$-TSE-Axial이 $0.21{\pm}0.01$로 측정되었다. 정성적 분석으로는 $T_1$-TSE-Axial에서 구강내 삽입 유도기구 사용 전 $3.49{\pm}0.11$, 사용 후 $3.95{\pm}0.14$로 나타났으며 $T_2$-TSE-Axial에서는 구강내 삽입 유도기구 사용 전 $3.25{\pm}0.18$, 삽입 후 $3.68{\pm}0.09$로 나타났다. 결론적으로 구강내 삽입 유도 기구의 사용으로 움직임 인공물이 해소되어 영상의 대조도와 분해능이 향상되었고 영상 판독에 있어 질환의 식별능력이 우수하여 영상의 질이 향상됨을 알 수 있었다.

폐암 SBRT에서 호흡동조 VMAT의 정확성 분석을 위한 새로운 4D 팬텀 모델 개발 (Development of New 4D Phantom Model in Respiratory Gated Volumetric Modulated Arc Therapy for Lung SBRT)

  • 윤경준;곽정원;조병철;송시열;이상욱;안승도;남상희
    • 한국의학물리학회지:의학물리
    • /
    • 제25권2호
    • /
    • pp.100-109
    • /
    • 2014
  • 정위신체방사선치료(SBRT)에서 환자의 호흡에 대한 정확한 치료위치의 확보는 필수적으로 고려되어야 하며 그 정확성에 관련하여 많은 연구들이 진행되어왔다. 본 연구에서는 실제 호흡에 의한 움직임과 실제 환자 폐의 형태를 고려한 팬텀실험으로 실제 치료에서 일어나는 임상적 상황을 모사함으로 호흡 동조 부피적조절회전 방사선치료(Volumeric Modulated Arc Therapy, VMAT) 기법을 이용한 폐부 SBRT의 정확성을 분석하는 방법을 제시하고자 하였다. SBRT을 받은 폐암 환자의 CT 영상을 기반으로 3D 프린터를 이용하여 치료부위와 유사하게 폐 팬텀을 제작하였고 환자 호흡과 동일하게 움직임을 재현할 수 있도록 $QUASAR^{TM}$ 호흡 동조 구동 팬텀(Modus Medical Devices, London, Canada)에 장착하여 호흡동조 VMAT에서의 2차원 선량 분포를 평가할 수 있는 시스템을 구축하였다. 폐 팬텀은 종양부위를 중심으로 2등분하여 EBT3 필름을 삽입하고 선량분포를 측정할 수 있도록 제작되었다. 비균질 조건에서의 선량계산의 정확성을 확인하기 위하여 균질한 플라스틱 팬텀과 제작된 비균질 폐 팬텀에서 Analytical Anisotropic Algorithm (AAA)와 AcurosXB (AXB) 두가지 알고리즘으로 선량계산을 하여 비교, 분석하였다. 움직임에 대한 치료의 정확성을 평가하기 위하여 호흡동조와 비 호흡동조의 경우, 그리고 움직임이 없는 조건에서 선량분포를 취득하여 치료계획 선량에 대한 감마지표를 분석하였다. 치료부위 GTV에서의 CT number는 실제 환자의 경우 78 HU를 나타내었고 모사된 폐 팬텀의 경우 92 HU를 나타내었다. 팬텀 내 폐 조직부분은 3D프린터로 적층하는 과정에서 격자구조의 형태를 이용하여 구현하였다. 측정된 필름선량은 AAA 알고리즘을 이용한 치료계획 선량에 대하여 움직이는 팬텀에서 호흡동조의 유무에 따라 3%/3 mm 감마지표 조건하에서 각각 88%와 78%의 감마합격률을 나타내었으며, 움직임이 없는 경우 95% 이상의 감마합격률을 보였다. AXB 알고리즘을 적용하였을 경우에는 모든 경우에서 98% 이상의 합격률을 나타내었다. 균질한 플라스틱 팬텀에 대하여 측정하였을 때 두가지 선량계산 알고리즘을 포함한 모든 조건에서 99% 이상의 감마합격률을 나타내었다. 선택된 환자의 호흡 진폭이 비교적 작고 inhale보다는 exhale에 더 오래 머무르는 호흡패턴 때문에 3%/3 mm 감마 기준에서는 호흡에 따른 차이가 거의 나타나지 않은 것으로 이해되었다. 선량계산의 정확성에서는 AAA 알고리즘을 적용하였을 때보다 AXB 알고리즘을 적용하였을 때가 균질과 비균질 환경에서의 선량 분포에 따른 감마 합격률의 차이가 적게 나타남을 확인 할 수 있었다. 본 논문에서는 환자와 유사하게 제작된 폐 팬텀에 실제 환자 호흡 패턴을 연동함으로 새로운 4D 치료선량 분포 검증 방법을 제시하였고 보다 사실적인 선량분포를 반영한 개별 환자 치료의 정확성 검증이 가능할 것으로 평가되었다.