• Title/Summary/Keyword: biomedical

Search Result 13,264, Processing Time 0.04 seconds

Finite element analysis for acoustic and temperature characteristics of a piezoelectric HIFU transducer at 10 MHz (10 MHz용 압전 HIFU 트랜스듀서의 음향 및 온도 특성에 대한 유한요소해석)

  • Jong-Ho Kim;Il-Gok Hong;Ho-Yong Shin;Hyo-Jun Ahn;Jong-In Im
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.33 no.3
    • /
    • pp.116-123
    • /
    • 2023
  • A high intensity focuses ultrasound (HIFU) is one of the emerging technologies in the biomedical field. The piezoelectric HIFU transducer is a device that utilizes the thermal energy generated by high ultrasound energy. Recently an operating frequency of the HIFU transducer is to expand above a 7 MHz. In this study, the acoustic pressures and temperature distributions in the tissue that generated by the HIFU transducer at 10 MHz were calculated with the finite element method. In addition, the pressure focusing characteristics of the device were analyzed. The geometrical variables are the piezomaterial thickness, lens shape, water height, and film thickness. The results shown that the acoustic pressure increased and saturated gradually when the height/radius (HL/RL) ratio of the lens increased. Moreover, the focal area was gradually decreases with HL/RL ratio of the lens. In case of the optimized HIFU transducer, the maximum pressure and temperature were analyzed about 19 MPa and 65℃ respectively. And the -3 dB focused distances in the axial and lateral direction are around 2.3 mm and 0.23 mm respectively.

Artesunate inhibits collagen-induced human platelets aggregation through regulation of PI3K/Akt and MAPK pathway (PI3K/Akt 및 MAPK 기전 조절을 통한 Artesunate의 콜라겐 유도의 사람 혈소판 응집 억제효과)

  • Lee, Dong-Ha
    • Journal of Applied Biological Chemistry
    • /
    • v.65 no.1
    • /
    • pp.57-62
    • /
    • 2022
  • Excessive activation and aggregation of platelets is a major cause of cardiovascular disease. Therefore, inhibition of platelet activation and aggregation is considered an attractive therapeutic target in preventing and treating cardiovascular diseases. In particular, strong platelet activation and aggregation by collagen secreted from the vascular endothelium are characteristic of vascular diseases. Artesunate is a compound extracted from the plant roots of Artemisia or Scopolia species, and has been reported to be effective in anticancer and Alzheimer's disease fields. However, the effect and mechanism of artesunate on collagen-induced platelet activation and aggregation have not been elucidated. In this study, the effect of artesunate on collagen-induced human platelet aggregation was confirmed and the mechanism of action of artesunate was clarified. Artesunate inhibited the phosphorylation of PI3K/Akt and Mitogen-activated protein kinases, which are phosphoproteins that are known to act in the signal transduction process when platelets are activated. In addition, artesunate decreased TXA2 production and decreased granule secretion in platelets such as ATP and serotonin release. As a result, artesunate strongly inhibited platelet aggregation induced by collagen, a strong aggregation inducer secreted from vascular endothelial cells, with an IC50 of 106.41 µM. These results suggest that artesunate has value as an effective antithrombotic agent for inhibiting the activation and aggregation of human platelets through vascular injury.

Added Value of Contrast Leakage Information over the CBV Value of DSC Perfusion MRI to Differentiate between Pseudoprogression and True Progression after Concurrent Chemoradiotherapy in Glioblastoma Patients

  • Pak, Elena;Choi, Seung Hong;Park, Chul-Kee;Kim, Tae Min;Park, Sung-Hye;Won, Jae-Kyung;Lee, Joo Ho;Lee, Soon-Tae;Hwang, Inpyeong;Yoo, Roh-Eul;Kang, Koung Mi;Yun, Tae Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.26 no.1
    • /
    • pp.10-19
    • /
    • 2022
  • Purpose: To evaluate whether the added value of contrast leakage information from dynamic susceptibility contrast magnetic resonance imaging (DSC MRI) is a better prognostic imaging biomarker than the cerebral blood volume (CBV) value in distinguishing true progression from pseudoprogression in glioblastoma patients. Materials and Methods: Forty-nine glioblastoma patients who had undergone MRI after concurrent chemoradiotherapy with temozolomide were enrolled in this retrospective study. Twenty features were extracted from the normalized relative CBV (nCBV) and extraction fraction (EF) map of the contrast-enhancing region in each patient. After univariable analysis, we used multivariable stepwise logistic regression analysis to identify significant predictors for differentiating between pseudoprogression and true progression. Receiver operating characteristic (ROC) analysis was employed to determine the best cutoff values for the nCBV and EF features. Finally, leave-one-out cross-validation was used to validate the best predictor in differentiating between true progression and pseudoprogression. Results: Multivariable stepwise logistic regression analysis showed that MGMT (O6-methylguanine-DNA methyltransferase) and EF max were independent differentiating variables (P = 0.004 and P = 0.02, respectively). ROC analysis yielded the best cutoff value of 95.75 for the EF max value for differentiating the two groups (sensitivity, 61%; specificity, 84.6%; AUC, 0.681 ± 0.08; 95% CI, 0.524-0.837; P = 0.03). In the leave-one-out cross-validation of the EF max value, the cross-validated values for predicting true progression and pseudoprogression accuracies were 69.4% and 71.4%, respectively. Conclusion: We demonstrated that contrast leakage information parameter from DSC MRI showed significance in differentiating true progression from pseudoprogression in glioblastoma patients.

A Study on the Measurement of Respiratory Rate Using Image Alignment and Statistical Pattern Classification (영상 정합 및 통계학적 패턴 분류를 이용한 호흡률 측정에 관한 연구)

  • Moon, Sujin;Lee, Eui Chul
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.10
    • /
    • pp.63-70
    • /
    • 2018
  • Biomedical signal measurement technology using images has been developed, and researches on respiration signal measurement technology for maintaining life have been continuously carried out. The existing technology measured respiratory signals through a thermal imaging camera that measures heat emitted from a person's body. In addition, research was conducted to measure respiration rate by analyzing human chest movement in real time. However, the image processing using the infrared thermal image may be difficult to detect the respiratory organ due to the external environmental factors (temperature change, noise, etc.), and thus the accuracy of the measurement of the respiration rate is low.In this study, the images were acquired using visible light and infrared thermal camera to enhance the area of the respiratory tract. Then, based on the two images, features of the respiratory tract region are extracted through processes such as face recognition and image matching. The pattern of the respiratory signal is classified through the k-nearest neighbor classifier, which is one of the statistical classification methods. The respiration rate was calculated according to the characteristics of the classified patterns and the possibility of breathing rate measurement was verified by analyzing the measured respiration rate with the actual respiration rate.

Taxonomic Review of Pristiophorus japonicus Complex (Pristiophoridae, Chondrichthyes) in the Northwest Pacific (북서태평양 톱상어(톱상어과, 연골어강)의 분류학적 재검토)

  • Myoung, Se Hun;Kim, Jin-Koo;Song, Choon Bok;Kai, Yoshiaki
    • Journal of Marine Life Science
    • /
    • v.1 no.1
    • /
    • pp.8-17
    • /
    • 2016
  • The family Pristiophoridae belonging to the order Pristiophoriformes consists of about 8 species and 2 genera in the world. Among them, only one species (Pristiophorus japonicus) is distributed in northwestern Pacific. The family is characterized by having an elongated and flattened rostrum with laterally projecting a low of sharp teeth. In order to clarify variability of local populations of P. japonicus, we investigated 16 individuals collected from four locations (Korea, n=6; Miyagi, n=1; Kochi Pref., n=1; Okinawa, n=8) for morphological and molecular analyses. Morphological analysis showed that there may exist three morphotypes, of which A morphotype (Korea, Miyagi, Kochi Pref.) has a short snout (26.8% of TL), being most similar to syntypes of P. japonicus. On the other hand, B morphotype (Okinawa) has a long (31.7% of TL) and wider snout (snout width at nostrils 5.2 times pre-oral length) and, C morphotype (Okinawa) has a long (31.7% of TL) and narrower snout (6.3 times). Molecular analysis using mitochondrial DNA cytochrome b DNA sequences (386 base pairs) showed that the K2P distance between A and C morphotypes were 2.1~2.7%, but those within A morphotype were 0.0~0.5%. We identified A morphotype as P. japonicus, and designated B and C morphotypes as Pristiophorus sp. 1 and Pristiophorus sp. 2, respectively. Further studies are required to elucidate the taxonomic status of two morphotypes of the sawshark in Okinawa.

Tube phonation in water for patients with hyperfunctional voice disorders: The effect of tube diameter and water immersion depth on bubble height and maximum phonation time (과기능적 음성장애 환자의 물저항발성: 튜브 직경과 물 깊이가 물거품 높이 및 최대발성지속시간에 미치는 영향)

  • Min Gyeong Kim;Seong Hee Choi;Jong-In Youn
    • Phonetics and Speech Sciences
    • /
    • v.15 no.2
    • /
    • pp.31-40
    • /
    • 2023
  • Tube phonation in water has been widely used for voice training among semi-occluded vocal tract (SOVT) exercises in which the patient bubbles with phonation keeping the tube submerged in water. This study aims to investigate the effect of tube diameter and water depth on bubble height and maximum phonation time (MPT) for patients with hyperfunctional voice disorders. Seventeen patients with hyperfunctional voice disorders were asked to bubble with sustained /u/ at the different inner diameters of tube (5, 7, and 10 mm), water depth (4, 7, and 10 cm). A water resistance phonation biofeedback system using a water height sensor was used for recording bubble height and MPT. The bubble height was significantly changed by the tube diameter while MPT was significantly changed with the tube diameter and water depth. Although the wider tube presented significantly lower bubble height for a given depth, relatively consistent bubble height was maintained. Depending on the water depth, the bubble height did not significantly differ for a given tube diameter. In addtion, MPT significantly decreased with water depth and a wider tube led significantly shorter MPT. A water level-driven water resistance biofeedback system provided useful information on bubble characteristics and vocal fold vibration depending on tube diameter and water depth. It can be useful to monitor the breath support during water resistance phonation for patients with hyperfunctional voice disorders.

Proposals on Basic Data Based on Comparison of Changes in Clinical Laboratory Technologists' National Examination and Job Definition: Focused on Korea, Japan, and Taiwan (임상병리사국가시험 및 직무의 변천 비교를 중심으로 한 기초자료 제안: 한국, 일본, 대만을 중심으로)

  • Bon-Kyeong KOO;Myung Soo KIM;Yoon Sik KIM;Jun Ho LEE
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.55 no.2
    • /
    • pp.71-81
    • /
    • 2023
  • This study examined the transition process of clinical laboratory technologists' national examination and job definition in Korea and compared the differences in the national examination between Korea and neighboring countries, such as Japan and Taiwan. In Korea, the number of questions made for it was 200 (1965), 200 (1977), 300 (1982), 250 (1992), 330 (2006), and 280 (2015). The practice of clinical physiology is important for real-time monitoring, given the characteristics of physiological testing. On the other hand, there are conflicts between other occupations in the working area. Clinical molecular biology needs to be established as a new major subject considering the diagnostic importance of molecular biological tests and the speed of science and technology development. Clinical laboratory operations provide policy and guidance recommendations to technologist staff. The proposed clinical laboratory technologists' national examination comprises major subjects: clinical biochemistry, clinical hematology, clinical transfusionology, clinical immunology, clinical microbiology, clinical molecular biology, clinical histology, clinical cytology, clinical physiology, and clinical laboratory operations. In addition, this study proposes the job definition of clinical laboratory technologists, revising various chemical or physiological testing to biomedical or physiological testing required for medical practice.

Comparison of WBCs and RBCs Concordance between the Cobas u 701 Analyzer and Three Manual Microscopy Methods in Urine Sediment (소변 침전물에서 Cobas u 701 Analyzer와 세 가지 수동 현미경검사법의 백혈구와 적혈구의 일치도 비교)

  • Hyeok-Jae LEE;Min-Hyeok LEE
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.55 no.2
    • /
    • pp.82-92
    • /
    • 2023
  • Urine sediments are performed by a microscopic examination of centrifuged urine by medical technologists. This study examined different urine sediment preparation procedures. The 107 fresh urine specimens that tested positive from white blood cells (WBCs) and red blood cells (RBCs) in the urine dipstick test and the cobas u 701 analyzer, respectively, were selected for manual microscopy. This study evaluated an automated urine sediment analyzer and three manual microscopy methods for WBCs and RBCs. The methods were performed according to the test guidelines. The coefficients of determination between the cobas u 701 analyzer and the Korean Association of Quality Assurance for Clinical Laboratory (KAQACL) for WBCs and RBCs were r2=0.977 and r2=0.970, respectively. The concordance rates between the cobas u 701 analyzer and KAQACL for WBCs and RBCs were 74.8% and 77.6%, respectively. A good correlation and concordance with the automatic analyzer were shown when the specimens were prepared and examined using the KAQACL method. Consequently, the differences in the urine sediment preparation procedures affected the sediment concentrations, influencing the cell number per high power field (HPF).

A parallel plate viscometer for blood viscosity measurement (혈액점도 측정용 평행판 점도계)

  • Donggil Seo;Kyung Hyun Ahn;Jihoon Kang;Sangsoo Park
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.331-335
    • /
    • 2023
  • As the viscosity of the blood increases, the blood becomes more sticky and difficult to flow, so the possibility of thrombosis increases and the probability of ischemic cerebral infarction increases. The importance of measuring blood viscosity has recently been emphasized for the prevention of circulatory system diseases, and the need for a viscometer capable of easily and accurately measuring blood viscosity has emerged. In this study, the measured values of a viscosity standard solution and an artificial blood by a parallel-plate viscometer ARS-Medi were compared with the those by Ares-G2 of TA instrument, which is internationally recognized for its accuracy and reliability. The viscosity of N44 standard solution, which is a Newtonian solution, was almost perfectly matched between the two instruments at all shear rates. In the case of an artificial blood, which is a non-Newtonian solution, the measured values between the two instruments showed a difference of about 10% at the lowest shear rate 1 rad/s; however, at a clinically significant shear rate of 10 rad/s or higher, the measured values between them were consistent within the error range. We expect that ARS-Medi, a newly developed parallel-plate viscometer for blood, using disposable plates, will be very useful in clinical practice as it improves the convenience and hygiene of blood viscosity measurement.

Monte Carlo Algorithm-Based Dosimetric Comparison between Commissioning Beam Data across Two Elekta Linear Accelerators with AgilityTM MLC System

  • Geum Bong Yu;Chang Heon Choi;Jung-in Kim;Jin Dong Cho;Euntaek Yoon;Hyung Jin Choun;Jihye Choi;Soyeon Kim;Yongsik Kim;Do Hoon Oh;Hwajung Lee;Lee Yoo;Minsoo Chun
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.150-157
    • /
    • 2022
  • Purpose: Elekta synergy® was commissioned in the Seoul National University Veterinary Medical Teaching Hospital. Recently, Chung-Ang University Gwang Myeong Hospital commissioned Elekta Versa HDTM. The beam characteristics of both machines are similar because of the same AgilityTM MLC Model. We compared measured beam data calculated using the Elekta treatment planning system, Monaco®, for each institute. Methods: Beam of the commissioning Elekta linear accelerator were measured in two independent institutes. After installing the beam model based on the measured beam data into the Monaco®, Monte Carlo (MC) simulation data were generated, mimicking the beam data in a virtual water phantom. Measured beam data were compared with the calculated data, and their similarity was quantitatively evaluated by the gamma analysis. Results: We compared the percent depth dose (PDD) and off-axis profiles of 6 MV photon and 6 MeV electron beams with MC calculation. With a 3%/3 mm gamma criterion, the photon PDD and profiles showed 100% gamma passing rates except for one inplane profile at 10 cm depth from VMTH. Gamma analysis of the measured photon beam off-axis profiles between the two institutes showed 100% agreement. The electron beams also indicated 100% agreement in PDD distributions. However, the gamma passing rates of the off-axis profiles were 91%-100% with a 3%/3 mm gamma criterion. Conclusions: The beam and their comparison with MC calculation for each institute showed good performance. Although the measuring tools were orthogonal, no significant difference was found.